Vincent Floré
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vincent Floré has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Adam J. Brown
Department of Interventional Cardiology, Papworth Hospital, Cambridge, UK
1 shared publication- Benny Drieghe
Heart Center, University Hospital Gent Gent Belgium
1 shared publication - Bert Vandeloo
Department of Cardiology, University Hospital Brussels , Brussels
1 shared publication - Chadi Ghafari
UMONS and CHU Ambroise Pare, Mons, Belgium
1 shared publication - Claudiu Ungureanu
Cardiovascular Jolimont Hospital La Louvière Belgium
1 shared publication Clive Lewis
Department of Transplantation, Papworth Hospital, Cambridge, UK
1 shared publication
Latest Publications
- 1 May 2023
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 35 (5) , E234-E247
iFR/FFR/IVUS Discordance and Clinical Implications: Results From the Prospective Left Main Physiology Registry
This study aimed to assess discordance between results of iFR, FFR, and intravascular ultrasound in intermediate left main coronary lesions.
- 1 May 2023
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 35 (5) , E234-E247
iFR/FFR/IVUS Discordance and Clinical Implications: Results From the Prospective Left Main Physiology Registry
This study aimed to assess discordance between results of iFR, FFR, and intravascular ultrasound in intermediate left main coronary lesions.
- 30 November 2017
- Published by Wiley in Clinical Transplantation
- Vol. 32 (2) , e13167
Intravascular ultrasound of the proximal left anterior descending artery is sufficient to detect early cardiac allograft vasculopathy
Objective: Cardiac allograft vasculopathy (CAV) can be detected early with intravascular ultrasound (IVUS), but there is limited information on the most efficient imaging protocol.Methods: Coronary angiography and IVUS of the three coronary arteries were performed. Volumetric IVUS analysis was performed, and a Stanford grade determined for each vessel.Results: Eighteen patients were included 18 (range 12‐24) months after transplantation. Angiographic CAV severity ranged from none (CAV0) to mild (CAV1), whereas IVUS CAV severity ranged from none (Stanford grade I) to severe (grade IV). Maximal intimal thickness measured with IVUS was significantly greater in the LAD (0.84 ± 0.48 mm) than in the LCX (0.46 ± 0.32 mm) or the RCA (0.53 ± 0.41 mm, P = .005). Diagnostic accuracy of IVUS in the left anterior descending artery was 100% (18 of 18 Stanford grades matched the patient's highest overall Stanford grade), 66% in the right coronary artery (12 of 18), and 56% in the left circumflex artery (11 of 18). The minimal required length of left anterior descending artery pullbacks to attain 100% accuracy was 36 mm (range 3‐36 mm) distal from the guide catheter ostium.Conclusions: These data suggest that focal IVUS imaging of the proximal LAD followed by volumetric analysis may suffice when screening for transplant vasculopathy.
- 30 November 2017
- Published by Wiley in Clinical Transplantation
- Vol. 32 (2) , e13167
Intravascular ultrasound of the proximal left anterior descending artery is sufficient to detect early cardiac allograft vasculopathy
Objective: Cardiac allograft vasculopathy (CAV) can be detected early with intravascular ultrasound (IVUS), but there is limited information on the most efficient imaging protocol.Methods: Coronary angiography and IVUS of the three coronary arteries were performed. Volumetric IVUS analysis was performed, and a Stanford grade determined for each vessel.Results: Eighteen patients were included 18 (range 12‐24) months after transplantation. Angiographic CAV severity ranged from none (CAV0) to mild (CAV1), whereas IVUS CAV severity ranged from none (Stanford grade I) to severe (grade IV). Maximal intimal thickness measured with IVUS was significantly greater in the LAD (0.84 ± 0.48 mm) than in the LCX (0.46 ± 0.32 mm) or the RCA (0.53 ± 0.41 mm, P = .005). Diagnostic accuracy of IVUS in the left anterior descending artery was 100% (18 of 18 Stanford grades matched the patient's highest overall Stanford grade), 66% in the right coronary artery (12 of 18), and 56% in the left circumflex artery (11 of 18). The minimal required length of left anterior descending artery pullbacks to attain 100% accuracy was 36 mm (range 3‐36 mm) distal from the guide catheter ostium.Conclusions: These data suggest that focal IVUS imaging of the proximal LAD followed by volumetric analysis may suffice when screening for transplant vasculopathy.