Baykal Yilmaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Baykal Yilmaz has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gül Dinç Ata
Bursa Uludag Universitesi
2 shared publications - Duygu Kürklü Arpaçay
Department of Prosthetic Dentistry, Faculty of Dentistry, Izmir Tınaztepe University, Izmir, Türkiye
1 shared publication - Esma Balin
DDS; Private Practice, Izmir, Turkey
1 shared publication - Esra Talay Çevlik
Department of Prosthodontics, Faculty of Dentistry, Aydın Adnan Menderes University, 09100 Aydın, Türkiye
1 shared publication - Özgür Irmak
Department of Restorative Dentistry, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir, Turkey
1 shared publication
Latest Publications
- Open Access
- 20 August 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-9
The impact of aging and thickness on flexural strength of various zirconia ceramics
Background: Effects of the aging process on the flexural strength of Y-TZP and different Y-PSZ ceramics of different thicknesses were investigated. Methods: 300 disc-shaped samples (12 mm diameter, 0.8 and 1.5 mm thicknesses) were made from 5 different zirconia materials 3Y-TZP LA, 4Y-PSZ, 5Y-PSZ, 3 + 5Y-PSZ and 4 + 5Y-PSZ. Experimental groups were artificially aged in an autoclave at 134 °C, 2 bar pressure for 1 and 5 h; control groups were not subjected to any treatment. Microstructural analysis was conducted using Scanning Electron Microscopy, and X-Ray Diffraction analysis determined the crystalline phase content. The impact of aging on flexural strength was investigated with the use of the biaxial flexural strength test. Data were analyzed using three-way ANOVA tests with a significance level of p < 0.05, applying Bonferroni correction for multiple comparisons. Results: Statistically significant differences in flexural strength were observed among the materials and the material thicknesses (p < 0.05), while there were no significant differences among the aging times (p > 0.05). The highest mean flexural strength values were recorded in the case of the 3 Y-TZP-1.5 mm–5 h group (744.1 ± 61.2 MPa), which was attributed to phase-transformation toughening. The lowest values were observed in the case of the 5 Y-PSZ-1.5 mm–5 h (338.3 ± 34.8 MPa) group. Conclusions: Both material type and thickness significantly affect the flexural strength of zirconia ceramics, whereas aging time does not; thus, material selection and thickness are crucial considerations for clinicians.
- 20 August 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-9
Open AccessThe impact of aging and thickness on flexural strength of various zirconia ceramics
Background: Effects of the aging process on the flexural strength of Y-TZP and different Y-PSZ ceramics of different thicknesses were investigated. Methods: 300 disc-shaped samples (12 mm diameter, 0.8 and 1.5 mm thicknesses) were made from 5 different zirconia materials 3Y-TZP LA, 4Y-PSZ, 5Y-PSZ, 3 + 5Y-PSZ and 4 + 5Y-PSZ. Experimental groups were artificially aged in an autoclave at 134 °C, 2 bar pressure for 1 and 5 h; control groups were not subjected to any treatment. Microstructural analysis was conducted using Scanning Electron Microscopy, and X-Ray Diffraction analysis determined the crystalline phase content. The impact of aging on flexural strength was investigated with the use of the biaxial flexural strength test. Data were analyzed using three-way ANOVA tests with a significance level of p < 0.05, applying Bonferroni correction for multiple comparisons. Results: Statistically significant differences in flexural strength were observed among the materials and the material thicknesses (p < 0.05), while there were no significant differences among the aging times (p > 0.05). The highest mean flexural strength values were recorded in the case of the 3 Y-TZP-1.5 mm–5 h group (744.1 ± 61.2 MPa), which was attributed to phase-transformation toughening. The lowest values were observed in the case of the 5 Y-PSZ-1.5 mm–5 h (338.3 ± 34.8 MPa) group. Conclusions: Both material type and thickness significantly affect the flexural strength of zirconia ceramics, whereas aging time does not; thus, material selection and thickness are crucial considerations for clinicians.
- Open Access
- 31 August 2022
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 49 (2) , 69-75
Evaluation of Repairability of Different Resin Composites After ph and Thermal Cycling
Purpose: The aim of this study was to investigate the effect of different aging methods on repair bond strength of different types of composite resins. Materials and Methods: Thirty resin composite blocks (5mm×5mm×4mm) were built up with a nanohybrid universal resin composite and a bulk-fill resin composite according to the manufacturer’s instructions, using a silicone matrix. Indirect resin composite blocks were obtained with similar dimensions from prefabricated blocks by microtome. All the samples were air abraded with 50µm aluminum oxide particles. Specimens were then repaired with a nanohybrid resin composite using two step adhesive system. All these specimens were then randomly divided into three groups for aging process (pH cycle, thermal cycle and control group) and tested for shear bond strength. Results were recorded in MPa. Additionally fractured specimens were examined under stereomicroscope to determine the mode of failure. The data was statistically analyzed using two-way ANOVA and Bonferroni correction test (p<0,05). Results: Statistically significant effect was found on the bond strength values of the aging method and the restorative material (p<0,05). Thermal cycle applied samples showed statistically significantly lower bond strength values than both pH cycle and control group samples (p<0,05). Regardless of the aging method, the overall bond strength of Tetric N-Ceram Bulk Fill is statistically significantly higher than bond strength of Tetric CAD (p<0,05). Conclusions: Thermal cycle application is an effective aging method and air abrasion has different effects on repair bond strength of the restorative materials according to the content of the materials.
- 31 August 2022
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 49 (2) , 69-75
Open AccessEvaluation of Repairability of Different Resin Composites After ph and Thermal Cycling
Purpose: The aim of this study was to investigate the effect of different aging methods on repair bond strength of different types of composite resins. Materials and Methods: Thirty resin composite blocks (5mm×5mm×4mm) were built up with a nanohybrid universal resin composite and a bulk-fill resin composite according to the manufacturer’s instructions, using a silicone matrix. Indirect resin composite blocks were obtained with similar dimensions from prefabricated blocks by microtome. All the samples were air abraded with 50µm aluminum oxide particles. Specimens were then repaired with a nanohybrid resin composite using two step adhesive system. All these specimens were then randomly divided into three groups for aging process (pH cycle, thermal cycle and control group) and tested for shear bond strength. Results were recorded in MPa. Additionally fractured specimens were examined under stereomicroscope to determine the mode of failure. The data was statistically analyzed using two-way ANOVA and Bonferroni correction test (p<0,05). Results: Statistically significant effect was found on the bond strength values of the aging method and the restorative material (p<0,05). Thermal cycle applied samples showed statistically significantly lower bond strength values than both pH cycle and control group samples (p<0,05). Regardless of the aging method, the overall bond strength of Tetric N-Ceram Bulk Fill is statistically significantly higher than bond strength of Tetric CAD (p<0,05). Conclusions: Thermal cycle application is an effective aging method and air abrasion has different effects on repair bond strength of the restorative materials according to the content of the materials.
- 30 April 2018
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 32 (20) , 2204-2219
Laser type effects on repair bond strength of ormocers and nanoceramic based composites
The aim of this study was to evaluate the effects of different surface treatments and different restoration materials on repair bond strength of ormocer and nanoceramic based composites. 24 (12 Admira, Voco, 12 Ceram X duo, Dentsply) thermally aged blocks (6 × 6 × 5 mm) were roughened with either bur, Er:YAG or Nd:YAG laser. In each group half of the roughened samples were repaired with composite of their respective brand; other half was repaired with composite of the other brand. All samples were subjected to microtensile bond strength test. Data were analyzed with Kruskal-Wallis and Bonferroni correction, Mann-Whitney U test (p = 0.05). For roughening methods no significant difference was found between Bur-Er:YAG (p = 0.536), however between the other groups (Bur-Nd:YAG and Er:YAG-Nd:YAG) significant difference were found (p < 0.001). For Admira as a filler material, no significant differences were found for bur, Er:YAG, Nd:YAG groups based on repair materials. For Ceram X duo as a filler material, while no significant differences were found for bur and Er:YAG groups; a significant difference was found for Nd:YAG group based on repair materials. A weak significant difference was found between the repair composite groups undergone thermocycling or not (p = 0.04). Surface roughening with Er:YAG laser can be used clinically for the repair of aged composite restorations.
- 30 April 2018
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 32 (20) , 2204-2219
Laser type effects on repair bond strength of ormocers and nanoceramic based composites
The aim of this study was to evaluate the effects of different surface treatments and different restoration materials on repair bond strength of ormocer and nanoceramic based composites. 24 (12 Admira, Voco, 12 Ceram X duo, Dentsply) thermally aged blocks (6 × 6 × 5 mm) were roughened with either bur, Er:YAG or Nd:YAG laser. In each group half of the roughened samples were repaired with composite of their respective brand; other half was repaired with composite of the other brand. All samples were subjected to microtensile bond strength test. Data were analyzed with Kruskal-Wallis and Bonferroni correction, Mann-Whitney U test (p = 0.05). For roughening methods no significant difference was found between Bur-Er:YAG (p = 0.536), however between the other groups (Bur-Nd:YAG and Er:YAG-Nd:YAG) significant difference were found (p < 0.001). For Admira as a filler material, no significant differences were found for bur, Er:YAG, Nd:YAG groups based on repair materials. For Ceram X duo as a filler material, while no significant differences were found for bur and Er:YAG groups; a significant difference was found for Nd:YAG group based on repair materials. A weak significant difference was found between the repair composite groups undergone thermocycling or not (p = 0.04). Surface roughening with Er:YAG laser can be used clinically for the repair of aged composite restorations.