Veit Babak Hamun Akbari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Veit Babak Hamun Akbari has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ben-Yi Liau
Department of Automatic Control Engineering Feng Chia University Taichung Taiwan
3 shared publications - Chi-Wen Lung
Rehabilitation Engineering Lab, Department of Health and Kinesiology University of Illinois at Urbana‐Champaign Urbana Illinois USA
3 shared publications - Yih-Kuen Jan
Department of Health and Kinesiology University of Illinois at Urbana‐Champaign Urbana Illinois USA
3 shared publications - Chih-Yang Lin
Department of Mechanical Engineering, National Central University, Taoyuan, Taiwan
2 shared publications - Fahni Haris
School of Nursing, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia
1 shared publication - Hsing-Chung Chen
Asia University
1 shared publication
Latest Publications
- Open Access
A Deep Learning Method for Foot Progression Angle Detection in Plantar Pressure Images
Foot progression angle (FPA) analysis is one of the core methods to detect gait pathologies as basic information to prevent foot injury from excessive in-toeing and out-toeing. Deep learning-based object detection can assist in measuring the FPA through plantar pressure images. This study aims to establish a precision model for determining the FPA. The precision detection of FPA can provide information with in-toeing, out-toeing, and rearfoot kinematics to evaluate the effect of physical therapy programs on knee pain and knee osteoarthritis. We analyzed a total of 1424 plantar images with three different You Only Look Once (YOLO) networks: YOLO v3, v4, and v5x, to obtain a suitable model for FPA detection. YOLOv4 showed higher performance of the profile-box, with average precision in the left foot of 100.00% and the right foot of 99.78%, respectively. Besides, in detecting the foot angle-box, the ground-truth has similar results with YOLOv4 (5.58 ± 0.10° vs. 5.86 ± 0.09°, p = 0.013). In contrast, there was a significant difference in FPA between ground-truth vs. YOLOv3 (5.58 ± 0.10° vs. 6.07 ± 0.06°, p < 0.001), and ground-truth vs. YOLOv5x (5.58 ± 0.10° vs. 6.75 ± 0.06°, p < 0.001). This result implies that deep learning with YOLOv4 can enhance the detection of FPA.
Open AccessA Deep Learning Method for Foot Progression Angle Detection in Plantar Pressure Images
Foot progression angle (FPA) analysis is one of the core methods to detect gait pathologies as basic information to prevent foot injury from excessive in-toeing and out-toeing. Deep learning-based object detection can assist in measuring the FPA through plantar pressure images. This study aims to establish a precision model for determining the FPA. The precision detection of FPA can provide information with in-toeing, out-toeing, and rearfoot kinematics to evaluate the effect of physical therapy programs on knee pain and knee osteoarthritis. We analyzed a total of 1424 plantar images with three different You Only Look Once (YOLO) networks: YOLO v3, v4, and v5x, to obtain a suitable model for FPA detection. YOLOv4 showed higher performance of the profile-box, with average precision in the left foot of 100.00% and the right foot of 99.78%, respectively. Besides, in detecting the foot angle-box, the ground-truth has similar results with YOLOv4 (5.58 ± 0.10° vs. 5.86 ± 0.09°, p = 0.013). In contrast, there was a significant difference in FPA between ground-truth vs. YOLOv3 (5.58 ± 0.10° vs. 6.07 ± 0.06°, p < 0.001), and ground-truth vs. YOLOv5x (5.58 ± 0.10° vs. 6.75 ± 0.06°, p < 0.001). This result implies that deep learning with YOLOv4 can enhance the detection of FPA.
- Open Access
- 13 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11851
A Review of the Plantar Pressure Distribution Effects from Insole Materials and at Different Walking Speeds
Among people with diabetes mellitus (DM), the two common strategies for decreasing peak plantar pressure (PPP) to reduce diabetic foot ulcers (DFUs) risks are to modify walking speeds and to change insole materials. This study reviewed the PPP reduction based on various walking speeds and insole materials. The articles were retrieved from four major scientific databases and manual search. We identified 1585 articles, of which 27 articles were selected for full-text analysis. We found that in faster walking speeds, the forefoot PPP was higher (308 kPa) than midfoot (150 kPa) and rearfoot (251 kPa) PPP. The appropriate walking speed for reducing the forefoot PPP was about 6 km/h for non-DM and 4 km/h for DM people. The forefoot PPP in DM people was 185% higher than that of non-DM people. Ethylene–vinyl acetate (EVA) insole material was the most popular material used by experts (26%) in the forefoot and reduced 37% of PPP. In conclusion, the suitable walking speed for DM was slower than for non-DM people, and EVA was the most common insole material used to decrease the PPP under the forefoot. The clinicians might recommend DM people to walk at 4 km/h and wear EVA insole material to minimize the DFUs.
- 13 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11851
Open AccessA Review of the Plantar Pressure Distribution Effects from Insole Materials and at Different Walking Speeds
Among people with diabetes mellitus (DM), the two common strategies for decreasing peak plantar pressure (PPP) to reduce diabetic foot ulcers (DFUs) risks are to modify walking speeds and to change insole materials. This study reviewed the PPP reduction based on various walking speeds and insole materials. The articles were retrieved from four major scientific databases and manual search. We identified 1585 articles, of which 27 articles were selected for full-text analysis. We found that in faster walking speeds, the forefoot PPP was higher (308 kPa) than midfoot (150 kPa) and rearfoot (251 kPa) PPP. The appropriate walking speed for reducing the forefoot PPP was about 6 km/h for non-DM and 4 km/h for DM people. The forefoot PPP in DM people was 185% higher than that of non-DM people. Ethylene–vinyl acetate (EVA) insole material was the most popular material used by experts (26%) in the forefoot and reduced 37% of PPP. In conclusion, the suitable walking speed for DM was slower than for non-DM people, and EVA was the most common insole material used to decrease the PPP under the forefoot. The clinicians might recommend DM people to walk at 4 km/h and wear EVA insole material to minimize the DFUs.
- Open Access
Estimation of Various Walking Intensities Based on Wearable Plantar Pressure Sensors Using Artificial Neural Networks
Walking has been demonstrated to improve health in people with diabetes and peripheral arterial disease. However, continuous walking can produce repeated stress on the plantar foot and cause a high risk of foot ulcers. In addition, a higher walking intensity (i.e., including different speeds and durations) will increase the risk. Therefore, quantifying the walking intensity is essential for rehabilitation interventions to indicate suitable walking exercise. This study proposed a machine learning model to classify the walking speed and duration using plantar region pressure images. A wearable plantar pressure measurement system was used to measure plantar pressures during walking. An Artificial Neural Network (ANN) was adopted to develop a model for walking intensity classification using different plantar region pressure images, including the first toe (T1), the first metatarsal head (M1), the second metatarsal head (M2), and the heel (HL). The classification consisted of three walking speeds (i.e., slow at 0.8 m/s, moderate at 1.6 m/s, and fast at 2.4 m/s) and two walking durations (i.e., 10 min and 20 min). Of the 12 participants, 10 participants (720 images) were randomly selected to train the classification model, and 2 participants (144 images) were utilized to evaluate the model performance. Experimental evaluation indicated that the ANN model effectively classified different walking speeds and durations based on the plantar region pressure images. Each plantar region pressure image (i.e., T1, M1, M2, and HL) generates different accuracies of the classification model. Higher performance was achieved when classifying walking speeds (0.8 m/s, 1.6 m/s, and 2.4 m/s) and 10 min walking duration in the T1 region, evidenced by an F1-score of 0.94. The dataset T1 could be an essential variable in machine learning to classify the walking intensity at different speeds and durations.
Open AccessEstimation of Various Walking Intensities Based on Wearable Plantar Pressure Sensors Using Artificial Neural Networks
Walking has been demonstrated to improve health in people with diabetes and peripheral arterial disease. However, continuous walking can produce repeated stress on the plantar foot and cause a high risk of foot ulcers. In addition, a higher walking intensity (i.e., including different speeds and durations) will increase the risk. Therefore, quantifying the walking intensity is essential for rehabilitation interventions to indicate suitable walking exercise. This study proposed a machine learning model to classify the walking speed and duration using plantar region pressure images. A wearable plantar pressure measurement system was used to measure plantar pressures during walking. An Artificial Neural Network (ANN) was adopted to develop a model for walking intensity classification using different plantar region pressure images, including the first toe (T1), the first metatarsal head (M1), the second metatarsal head (M2), and the heel (HL). The classification consisted of three walking speeds (i.e., slow at 0.8 m/s, moderate at 1.6 m/s, and fast at 2.4 m/s) and two walking durations (i.e., 10 min and 20 min). Of the 12 participants, 10 participants (720 images) were randomly selected to train the classification model, and 2 participants (144 images) were utilized to evaluate the model performance. Experimental evaluation indicated that the ANN model effectively classified different walking speeds and durations based on the plantar region pressure images. Each plantar region pressure image (i.e., T1, M1, M2, and HL) generates different accuracies of the classification model. Higher performance was achieved when classifying walking speeds (0.8 m/s, 1.6 m/s, and 2.4 m/s) and 10 min walking duration in the T1 region, evidenced by an F1-score of 0.94. The dataset T1 could be an essential variable in machine learning to classify the walking intensity at different speeds and durations.