Maria Frentiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maria Frentiu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Michaela Ponta
Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania
20 shared publications - Tiberiu Frentiu
Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania
19 shared publications - Eugen Darvasi
Babes-Bolyai University
17 shared publications - Dorin Petreus
Applied Electronics Department, Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania
11 shared publications - Marin Senila
Research Institute for Analytical Instrumentation subsidiary, National Institute for Research and Development of Optoelectronics Bucharest INOE 2000, 67 Donath Street, 400293 Cluj-Napoca, Romania
10 shared publications - Eniko Covaci
Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, Arany Janos 11, 400028 Cluj-Napoca, Romania
6 shared publications
Latest Publications
- Open Access
- 24 September 2025
- Published by Babes-Bolyai University Cluj-Napoca in Studia Universitatis Babeș-Bolyai Chemia
- p. 21-33
MOLYBDENUM FLAT COIL FILAMENT FOR SAMPLE INTRODUCTION AND MULTIELEMENTAL DETERMINATION BY SMALL-SIZED ELECTROTHERMAL VAPORIZATION CAPACITIVELY COUPLED MICROPLASMA OPTICAL EMISSION SPECTROMETRY
A novel small-sized electrothermal vaporization device including a molybdenum flat coil filament was studied for sample introduction into a capacitively coupled microplasma (SSETV-µCCP-OES) for the simultaneous multielemental determination of Cu, Zn, Pb, Cd, Hg, Se, Te, Sb and Bi by optical emission spectrometry. The limits of detection, obtained by this experimental setup were 2–25 times lower than those previously obtained using a Rh coil filament, ranging from 0.16 µg L–1 for Cd to 10.7 µg L–¹ for Se. This improvement was primarily attributed to the more efficient heating of the Mo flat coil filament compared to the Rh coil filament, considering that Rh has a lower melting point and therefore must be heated more gradually. Consequently, in the transient spectra recorded using the Mo flat coil filament the maximum signal intensities were observed earlier, ranging from 1.5 s for Hg to 3.3 s for Zn, compared to those obtained with the Rh coil filament, which ranged from 2.4 s for Hg to 5.3 s for Cu. The results demonstrate the strong analytical potential of the SSETV device with the Mo flat coil filament, for the simultaneous multielemental trace metal analysis.
- 24 September 2025
- Published by Babes-Bolyai University Cluj-Napoca in Studia Universitatis Babeș-Bolyai Chemia
- p. 21-33
Open AccessMOLYBDENUM FLAT COIL FILAMENT FOR SAMPLE INTRODUCTION AND MULTIELEMENTAL DETERMINATION BY SMALL-SIZED ELECTROTHERMAL VAPORIZATION CAPACITIVELY COUPLED MICROPLASMA OPTICAL EMISSION SPECTROMETRY
A novel small-sized electrothermal vaporization device including a molybdenum flat coil filament was studied for sample introduction into a capacitively coupled microplasma (SSETV-µCCP-OES) for the simultaneous multielemental determination of Cu, Zn, Pb, Cd, Hg, Se, Te, Sb and Bi by optical emission spectrometry. The limits of detection, obtained by this experimental setup were 2–25 times lower than those previously obtained using a Rh coil filament, ranging from 0.16 µg L–1 for Cd to 10.7 µg L–¹ for Se. This improvement was primarily attributed to the more efficient heating of the Mo flat coil filament compared to the Rh coil filament, considering that Rh has a lower melting point and therefore must be heated more gradually. Consequently, in the transient spectra recorded using the Mo flat coil filament the maximum signal intensities were observed earlier, ranging from 1.5 s for Hg to 3.3 s for Zn, compared to those obtained with the Rh coil filament, which ranged from 2.4 s for Hg to 5.3 s for Cu. The results demonstrate the strong analytical potential of the SSETV device with the Mo flat coil filament, for the simultaneous multielemental trace metal analysis.
- 3 April 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (5) , 799-808
A highly sensitive eco-scale method for mercury determination in water and food using photochemical vapor generation and miniaturized instrumentation for capacitively coupled plasma microtorch optical emission spectrometry
A highly sensitive method based on UV photochemical vapor generation capacitively coupled plasma microtorch optical emission using a low resolution microspectrometer was developed for total mercury determination in food and water. The method fulfils most of the eco-scale criteria in terms of derivatization and cost-effective miniaturized instrumentation, which are major benefits compared to cold vapor atomic fluorescence spectrometry and inductively coupled plasma optical emission spectrometry. Formic acid was the single reagent used for the extraction of Hg species from solid samples and as a reaction medium for the UV photo-induced cold vapor generation. A 200 mg lyophilized sample was subjected to ultrasonic assisted extraction in 10 mL of HCOOH 98–100% at 50 °C for 3 h, and then on-line derivatization to cold vapor was performed in 0.6 mol L−1 HCOOH. Water and food with low Hg content adjusted in HCOOH 0.6 mol L−1 underwent on-line preconcentration of Hg vapor on a gold filament microcollector. Total Hg was quantified against external standards containing Hg2+ by recording emission at 253.652 nm in a low power/Ar consumption (15 W/100 mL min−1) plasma source with a Maya2000 Pro (Ocean Optics) microspectrometer. The proposed method was compared with common laboratory approaches based on derivatization with SnCl2 and detection by inductively coupled plasma optical emission spectrometry/atomic fluorescence spectrometry, and thermal decomposition atomic absorption spectrometry. The limits of detection obtained without/with preconcentration were 3.5/0.1 ng L−1 in solution and 9/0.25 μg kg−1 in the solid, much better than those in the reference methods. The proposed method was found to be free from interference coming from multimineral matrices and organic matter, and suitable for sample analysis with various matrices as it provided a recovery of Hg without/with preconcentration of 101 ± 7%/101 ± 12% in food and 97 ± 12% in water.
- 3 April 2018
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 33 (5) , 799-808
A highly sensitive eco-scale method for mercury determination in water and food using photochemical vapor generation and miniaturized instrumentation for capacitively coupled plasma microtorch optical emission spectrometry
A highly sensitive method based on UV photochemical vapor generation capacitively coupled plasma microtorch optical emission using a low resolution microspectrometer was developed for total mercury determination in food and water. The method fulfils most of the eco-scale criteria in terms of derivatization and cost-effective miniaturized instrumentation, which are major benefits compared to cold vapor atomic fluorescence spectrometry and inductively coupled plasma optical emission spectrometry. Formic acid was the single reagent used for the extraction of Hg species from solid samples and as a reaction medium for the UV photo-induced cold vapor generation. A 200 mg lyophilized sample was subjected to ultrasonic assisted extraction in 10 mL of HCOOH 98–100% at 50 °C for 3 h, and then on-line derivatization to cold vapor was performed in 0.6 mol L−1 HCOOH. Water and food with low Hg content adjusted in HCOOH 0.6 mol L−1 underwent on-line preconcentration of Hg vapor on a gold filament microcollector. Total Hg was quantified against external standards containing Hg2+ by recording emission at 253.652 nm in a low power/Ar consumption (15 W/100 mL min−1) plasma source with a Maya2000 Pro (Ocean Optics) microspectrometer. The proposed method was compared with common laboratory approaches based on derivatization with SnCl2 and detection by inductively coupled plasma optical emission spectrometry/atomic fluorescence spectrometry, and thermal decomposition atomic absorption spectrometry. The limits of detection obtained without/with preconcentration were 3.5/0.1 ng L−1 in solution and 9/0.25 μg kg−1 in the solid, much better than those in the reference methods. The proposed method was found to be free from interference coming from multimineral matrices and organic matter, and suitable for sample analysis with various matrices as it provided a recovery of Hg without/with preconcentration of 101 ± 7%/101 ± 12% in food and 97 ± 12% in water.
- 16 September 2017
- Published by Springer Nature in Chemical Papers
- Vol. 72 (2) , 441-448
Mercury speciation in fish tissue by eco-scale thermal decomposition atomic absorption spectrometry: method validation and risk exposure to methylmercury
- 16 September 2017
- Published by Springer Nature in Chemical Papers
- Vol. 72 (2) , 441-448
Mercury speciation in fish tissue by eco-scale thermal decomposition atomic absorption spectrometry: method validation and risk exposure to methylmercury
- 9 December 2016
- Published by Springer Nature in Chemical Papers
- Vol. 71 (1) , 91-102
A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
- 9 December 2016
- Published by Springer Nature in Chemical Papers
- Vol. 71 (1) , 91-102
A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
- 1 March 2016
- Published by Elsevier in Food Control
- Vol. 61, 227-234
Determination of Cd in food using an electrothermal vaporization capacitively coupled plasma microtorch optical emission microspectrometer: Compliance with European legislation and comparison with graphite furnace atomic absorption spectrometry
- 1 March 2016
- Published by Elsevier in Food Control
- Vol. 61, 227-234
Determination of Cd in food using an electrothermal vaporization capacitively coupled plasma microtorch optical emission microspectrometer: Compliance with European legislation and comparison with graphite furnace atomic absorption spectrometry
- 2 March 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (5) , 1161-1168
Sono-induced cold vapour generation interfaced with capacitively coupled plasma microtorch optical emission spectrometry: analytical characterization and comparison with atomic fluorescence spectrometry
Sono-induced cold vapour generation in 0.2 mol L−1 formic acid has been interfaced for the first time with a low power (10 W) and low argon consumption (100 mL min−1) capacitively coupled plasma microtorch for mercury determination by optical emission using a low resolution microspectrometer. The method meets the requirements of green analytical chemistry in terms of the derivatisation method, cost-effective conditions for plasma generation and miniaturized instrumentation. The method is based on sample ultrasonication in a batch reactor, purging of mercury vapour, moisture removal from vapour in a Nafion tubing, Hg preconcentration on a gold filament microcollector, thermal desorption and introduction of mercury vapour into plasma via an Ar stream. Emission episode spectra of Hg were recorded at 253.652 nm. Under the optimized conditions, a detection limit of 5.0 ± 0.3 ng L−1 was found, which was better than the 12 ng L−1 obtained by atomic fluorescence spectrometry after chemical cold vapour generation with SnCl2. The analytical capability of the new method was demonstrated by analysing the certified reference materials and real samples of fish tissue, soil and sediment mineralized in an acidic mixture. The method is highly sensitive and the matrix effects associated with cold vapour generation were avoided by sample dilution. Mercury was determined using external calibration with recovery and precision in the range of 96.3–104.5% and 0.8–7%, respectively. No systematic error against atomic fluorescence with chemical cold vapour generation using SnCl2 was observed.
- 2 March 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (5) , 1161-1168
Sono-induced cold vapour generation interfaced with capacitively coupled plasma microtorch optical emission spectrometry: analytical characterization and comparison with atomic fluorescence spectrometry
Sono-induced cold vapour generation in 0.2 mol L−1 formic acid has been interfaced for the first time with a low power (10 W) and low argon consumption (100 mL min−1) capacitively coupled plasma microtorch for mercury determination by optical emission using a low resolution microspectrometer. The method meets the requirements of green analytical chemistry in terms of the derivatisation method, cost-effective conditions for plasma generation and miniaturized instrumentation. The method is based on sample ultrasonication in a batch reactor, purging of mercury vapour, moisture removal from vapour in a Nafion tubing, Hg preconcentration on a gold filament microcollector, thermal desorption and introduction of mercury vapour into plasma via an Ar stream. Emission episode spectra of Hg were recorded at 253.652 nm. Under the optimized conditions, a detection limit of 5.0 ± 0.3 ng L−1 was found, which was better than the 12 ng L−1 obtained by atomic fluorescence spectrometry after chemical cold vapour generation with SnCl2. The analytical capability of the new method was demonstrated by analysing the certified reference materials and real samples of fish tissue, soil and sediment mineralized in an acidic mixture. The method is highly sensitive and the matrix effects associated with cold vapour generation were avoided by sample dilution. Mercury was determined using external calibration with recovery and precision in the range of 96.3–104.5% and 0.8–7%, respectively. No systematic error against atomic fluorescence with chemical cold vapour generation using SnCl2 was observed.