Sheng Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sheng Dong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Lingjie Meng
School of Chemistry, Xi'an Jiaotong University, Xi'an 710049, China
2 shared publications Da Xi
The Third Affiliated Hospital, Second Military Medical University, Shanghai 200438, P.R. China
1 shared publicationHongdan Peng
School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
1 shared publicationJian-Ding Ye
Department of Radiology, Shanghai Chest Hospital Affiliated to Shanghai Jiaotong University, Shanghai 200030, P.R. China
1 shared publicationJin Ye
JBridge LLC, 9009 Great Hills Trl, Austin, TX 78759, USA
1 shared publication- Paul Joseph Dyson
Institute of Chemical Sciences and Engineering Ecole Polytechnique Fédérale de Lausanne (EPFL) Lausanne Switzerland
1 shared publication
Latest Publications
- 20 September 2012
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 2 (33) , 12515-12524
Gold nanoparticles as computerized tomography (CT) contrast agents
Gold nanoparticles (GNPs) are emerging as one of the most promising contrast agents for computerized tomography (CT) due to their remarkable properties including high X-ray absorption coefficient, low cytotoxicity, tailored surface chemistry, excellent biocompatibility, and unique surface plasmon resonance. Moreover, GNPs with tumor cell targeting molecules can specifically show the tumor tissues, leading to an intriguing feature of molecular imaging. In this article we provide a historical perspective on the GNPs used as CT contrast agents. We summarize the CT imaging principles of GNPs, review the current status of available methodologies for their preparation and surface modification, and highlight the recent achievements in their contrast effect and toxicity. Finally, the future opportunities and challenges of GNPs used as CT contrast agents are addressed for our understanding.
- 20 September 2012
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 2 (33) , 12515-12524
Gold nanoparticles as computerized tomography (CT) contrast agents
Gold nanoparticles (GNPs) are emerging as one of the most promising contrast agents for computerized tomography (CT) due to their remarkable properties including high X-ray absorption coefficient, low cytotoxicity, tailored surface chemistry, excellent biocompatibility, and unique surface plasmon resonance. Moreover, GNPs with tumor cell targeting molecules can specifically show the tumor tissues, leading to an intriguing feature of molecular imaging. In this article we provide a historical perspective on the GNPs used as CT contrast agents. We summarize the CT imaging principles of GNPs, review the current status of available methodologies for their preparation and surface modification, and highlight the recent achievements in their contrast effect and toxicity. Finally, the future opportunities and challenges of GNPs used as CT contrast agents are addressed for our understanding.
- 17 May 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 22 (30) , 14868-14873
Fabrication of reduced graphene oxide hybrid materials that exhibit strong fluorescence
Fluorescent graphene-based materials have been prepared by a facile ion exchange route comprising the reaction of carboxylated, reduced graphene oxide (c-RGO) with fluorescent anthracene-modified imidazolium salts in water–ethanol solution. The resulting reduced graphene oxide hybrid materials emit strong blue light at 392, 414 and 438 nm and maintain a relatively high quantum yield (QY, 0.29), as electron and energy transfer between the anthracene moieties and the graphene plane is blocked by the imidazolium moiety. In contrast, physical mixing of the imidazolium salt with non-carboxylated reduced graphene oxide (n-RGO) affords a material that exhibits negligible fluorescence due to direct π–π stacking interactions between the n-RGO plane and the anthracene moieties.
- 17 May 2012
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 22 (30) , 14868-14873
Fabrication of reduced graphene oxide hybrid materials that exhibit strong fluorescence
Fluorescent graphene-based materials have been prepared by a facile ion exchange route comprising the reaction of carboxylated, reduced graphene oxide (c-RGO) with fluorescent anthracene-modified imidazolium salts in water–ethanol solution. The resulting reduced graphene oxide hybrid materials emit strong blue light at 392, 414 and 438 nm and maintain a relatively high quantum yield (QY, 0.29), as electron and energy transfer between the anthracene moieties and the graphene plane is blocked by the imidazolium moiety. In contrast, physical mixing of the imidazolium salt with non-carboxylated reduced graphene oxide (n-RGO) affords a material that exhibits negligible fluorescence due to direct π–π stacking interactions between the n-RGO plane and the anthracene moieties.
- 12 December 2011
- Published by Spandidos Publications in Oncology Letters
- Vol. 3 (3) , 672-676
Characterization of solitary pulmonary nodules: Use of washout characteristics at contrast-enhanced computed tomography
The purpose of this study was to determine whether computed tomographic scans and attenuation measurements on contrast material‑enhanced and non-enhanced computed tomographic scans could be used to characterize solitary pulmonary nodules and, in particular, to characterize these lesions using washout characteristics on contrast-enhanced computed tomography. A total of 63 patients (38 males, 25 females; age range, 21-80 years; mean age, 58±13.2 years) with pulmonary nodules revealed on contrast-enhanced computed tomography underwent 20-min delayed enhanced scans. The mean diameter of the pulmonary nodules was 1.8±0.6 cm (range, 0.8‑2.9). Region-of-interest measurements were obtained at non‑enhanced, dynamic enhanced and delayed enhanced computed tomography and were used to calculate a relative percentage washout as follows: 1 ‑ (Hounsfield unit measurement on delayed image/Hounsfield unit measurement on dynamic image) x 100%. There was a mean relative washout of 33% on the delayed computed tomographic scans (range, 12‑46) in benign solitary pulmonary nodules; and a mean relative washout of 7% (range, -36‑51) in malignant solitary pulmonary nodules (Mann-Whitney U test, p<0.001). Results of the receiver operating curve analysis revealed that a threshold relative washout of 14.5% had 74.3% sensitivity and 92.9% specificity for identifying malignant nodules. Calculation of the relative percentage washout on dynamic and delayed enhanced computed tomographic scans may lead to a highly specific test for solitary pulmonary nodule characterization and reduce the need for, and possibly obviate, follow-up imaging or biopsy.
- 12 December 2011
- Published by Spandidos Publications in Oncology Letters
- Vol. 3 (3) , 672-676
Characterization of solitary pulmonary nodules: Use of washout characteristics at contrast-enhanced computed tomography
The purpose of this study was to determine whether computed tomographic scans and attenuation measurements on contrast material‑enhanced and non-enhanced computed tomographic scans could be used to characterize solitary pulmonary nodules and, in particular, to characterize these lesions using washout characteristics on contrast-enhanced computed tomography. A total of 63 patients (38 males, 25 females; age range, 21-80 years; mean age, 58±13.2 years) with pulmonary nodules revealed on contrast-enhanced computed tomography underwent 20-min delayed enhanced scans. The mean diameter of the pulmonary nodules was 1.8±0.6 cm (range, 0.8‑2.9). Region-of-interest measurements were obtained at non‑enhanced, dynamic enhanced and delayed enhanced computed tomography and were used to calculate a relative percentage washout as follows: 1 ‑ (Hounsfield unit measurement on delayed image/Hounsfield unit measurement on dynamic image) x 100%. There was a mean relative washout of 33% on the delayed computed tomographic scans (range, 12‑46) in benign solitary pulmonary nodules; and a mean relative washout of 7% (range, -36‑51) in malignant solitary pulmonary nodules (Mann-Whitney U test, p<0.001). Results of the receiver operating curve analysis revealed that a threshold relative washout of 14.5% had 74.3% sensitivity and 92.9% specificity for identifying malignant nodules. Calculation of the relative percentage washout on dynamic and delayed enhanced computed tomographic scans may lead to a highly specific test for solitary pulmonary nodule characterization and reduce the need for, and possibly obviate, follow-up imaging or biopsy.