Jongyoon Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jongyoon Han has a total of 460 co-authors. Here are the top co-authors by number of shared publications:
- Chwee Teck Lim
Department of Biomedical Engineering, National University of Singapore
17 shared publications - Yong-Ak Song
New York University Abu Dhabi
13 shared publications - Han Wei Hou
Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore
12 shared publications - Ali Asgar Saleem Bhagat
Institute for Health Innovation & Technology (iHealthtech), National University of Singapore (NUS), MD6, 14 Medical Drive, #14-01, Singapore 117599, Singapore
11 shared publications - Bee Luan Khoo
Department of Biomedical Engineering College of Biomedicine City University of Hong Kong Hong Kong China
10 shared publications - Hyungkook Jeon
Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
10 shared publications
Latest Publications
- Open Access
- 5 August 2026
- Published by Wiley in Biotechnology Progress
- p. e88550
Regenerative perfusion bioreactor for biologics production with lower COGs
Perfusion bioreactor systems enable intensified bioprocessing with high cell densities and volumetric productivities in monoclonal antibody (mAb) manufacturing. However, their widespread adoption remains constrained by the high consumption of chemically defined cell culture media. In this study, we introduce a multi‐stage electrokinetic waste separation process that regenerates spent media, recovering up to 87.5% of the spent‐medium volume for reuse. Using a mock‐perfusion model, the regeneration‐recycle processes were shown to sustain high‐density Chinese hamster ovary cell growth, compared with spent media recycling without regeneration. Integration into a self‐recycling perfusion bioreactor (350 mL working volume) operating with 75% regenerated media sustained the target viable cell density and antibody titer, with limited reductions to cell‐specific growth rate (~31%) and cell‐specific productivity (~9%), supporting the feasibility of high‐ratio media recycling. Techno‐economic modeling of large‐scale scenarios revealed that media regeneration could offer a path to $15/g COGs, thereby increasing the accessibility of mAbs. Techno‐economic modeling of hypothetical large‐scale manufacturing scenarios indicated that the experimentally demonstrated process could reduce cost of goods (COG) by approximately 9%, and identified a theoretical pathway toward ~$15/g COG contingent upon multi‐cycle regeneration processes that could be developed in the future. These results support regenerative perfusion as a promising process‐intensification strategy that, with further development, may be adaptable to other mammalian cell culture platforms where media cost and sustainability are critical bottlenecks.
- 5 August 2026
- Published by Wiley in Biotechnology Progress
- p. e88550
Open AccessRegenerative perfusion bioreactor for biologics production with lower COGs
Perfusion bioreactor systems enable intensified bioprocessing with high cell densities and volumetric productivities in monoclonal antibody (mAb) manufacturing. However, their widespread adoption remains constrained by the high consumption of chemically defined cell culture media. In this study, we introduce a multi‐stage electrokinetic waste separation process that regenerates spent media, recovering up to 87.5% of the spent‐medium volume for reuse. Using a mock‐perfusion model, the regeneration‐recycle processes were shown to sustain high‐density Chinese hamster ovary cell growth, compared with spent media recycling without regeneration. Integration into a self‐recycling perfusion bioreactor (350 mL working volume) operating with 75% regenerated media sustained the target viable cell density and antibody titer, with limited reductions to cell‐specific growth rate (~31%) and cell‐specific productivity (~9%), supporting the feasibility of high‐ratio media recycling. Techno‐economic modeling of large‐scale scenarios revealed that media regeneration could offer a path to $15/g COGs, thereby increasing the accessibility of mAbs. Techno‐economic modeling of hypothetical large‐scale manufacturing scenarios indicated that the experimentally demonstrated process could reduce cost of goods (COG) by approximately 9%, and identified a theoretical pathway toward ~$15/g COG contingent upon multi‐cycle regeneration processes that could be developed in the future. These results support regenerative perfusion as a promising process‐intensification strategy that, with further development, may be adaptable to other mammalian cell culture platforms where media cost and sustainability are critical bottlenecks.
- Open Access
- 7 June 2026
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 123 (9) , 2342-2352
Fouling‐Free Inertial Microfluidic Cell Clarification for Lentivirus Manufacturing
Lentiviral vectors (LVVs) are widely used as gene‐delivery vehicles in cell and gene therapy, enabling stable integration of transgenes into target cells. However, efficient clarification of LVV harvest remains a major bottleneck in large‐scale manufacturing, as conventional depth filtration often results in significant product loss. Here, we introduce a fouling‐free microfluidic cell clarification (MCC) system that enables high‐efficiency LVV recovery. By precisely controlling the harvest flow rate and adjusting the recirculated cell density by adding buffer, we established a quantitative relationship between clarification efficiency and throughput. Under optimized conditions, the MCC achieved > 95% product recovery while maintaining > 95% cell removal efficiency. The MCC process closely followed the theoretical recovery model assuming negligible product loss within the device. Across three independent batch operations, apparent average LVV recovery remained substantially higher than that of a benchmark process employing a cellulose depth filter‐based process. Scalability tests demonstrated consistent performance at flow rates up to 1.5 L/h without loss of clarification efficiency, demonstrating its potential for large‐scale biomanufacturing. Beyond LVVs, the MCC platform is broadly applicable to cell‐based modalities that secrete therapeutic products, offering a continuous, low‐shear, and fouling‐free alternative to conventional filtration processes.
- 7 June 2026
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 123 (9) , 2342-2352
Open AccessFouling‐Free Inertial Microfluidic Cell Clarification for Lentivirus Manufacturing
Lentiviral vectors (LVVs) are widely used as gene‐delivery vehicles in cell and gene therapy, enabling stable integration of transgenes into target cells. However, efficient clarification of LVV harvest remains a major bottleneck in large‐scale manufacturing, as conventional depth filtration often results in significant product loss. Here, we introduce a fouling‐free microfluidic cell clarification (MCC) system that enables high‐efficiency LVV recovery. By precisely controlling the harvest flow rate and adjusting the recirculated cell density by adding buffer, we established a quantitative relationship between clarification efficiency and throughput. Under optimized conditions, the MCC achieved > 95% product recovery while maintaining > 95% cell removal efficiency. The MCC process closely followed the theoretical recovery model assuming negligible product loss within the device. Across three independent batch operations, apparent average LVV recovery remained substantially higher than that of a benchmark process employing a cellulose depth filter‐based process. Scalability tests demonstrated consistent performance at flow rates up to 1.5 L/h without loss of clarification efficiency, demonstrating its potential for large‐scale biomanufacturing. Beyond LVVs, the MCC platform is broadly applicable to cell‐based modalities that secrete therapeutic products, offering a continuous, low‐shear, and fouling‐free alternative to conventional filtration processes.
- Open Access
- 8 May 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (12) , 3810-3824
High-recovery AAV clarification using a multiplexed spiral inertial microfluidic platform
A 25-layer spiral microfluidic device significantly reduces cell biomass from high-turbidity feedstock using inertial focusing to perform primary clarification and harvest adeno-associated virus (AAV) vectors at 20 mL min −1 with 85% vector recovery.
- 8 May 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (12) , 3810-3824
Open AccessHigh-recovery AAV clarification using a multiplexed spiral inertial microfluidic platform
A 25-layer spiral microfluidic device significantly reduces cell biomass from high-turbidity feedstock using inertial focusing to perform primary clarification and harvest adeno-associated virus (AAV) vectors at 20 mL min −1 with 85% vector recovery.
- 15 April 2026
- Published by Elsevier in Bioresource Technology
- Vol. 453, 134633
Microalgae concentration system for early harmful algae bloom detection using inertial microfluidic focusing
- 15 April 2026
- Published by Elsevier in Bioresource Technology
- Vol. 453, 134633
Microalgae concentration system for early harmful algae bloom detection using inertial microfluidic focusing
- Open Access
- 14 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (16) , 24851-24857
Rapid Parallel Magnetic Resonance Relaxometry on Multiwell Plates with a Benchtop Scanner
Nuclear magnetic resonance relaxometry measurements have a diverse array of applications in medicine, biology, and chemistry, and they are valuable for monitoring cell cultures, diagnosing diseases, and detecting defects in pharmaceutical products. However, relaxometry workflows typically require laborious procedures and large sample volumes, which are both slow and destructive. This makes it difficult to use relaxometry in applications such as drug screening and cell culture development, where it has significant potential to be useful. In this work, we describe and demonstrate a low-cost benchtop system that can perform relaxometry measurements on 16 wells of a 96-well culture plate in one shot, enabling rapid, nondestructive scanning of multiple groups without any sample preparation. We demonstrate the application of this multiwell scanner for iron measurement and parallel measurements.
- 14 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (16) , 24851-24857
Open AccessRapid Parallel Magnetic Resonance Relaxometry on Multiwell Plates with a Benchtop Scanner
Nuclear magnetic resonance relaxometry measurements have a diverse array of applications in medicine, biology, and chemistry, and they are valuable for monitoring cell cultures, diagnosing diseases, and detecting defects in pharmaceutical products. However, relaxometry workflows typically require laborious procedures and large sample volumes, which are both slow and destructive. This makes it difficult to use relaxometry in applications such as drug screening and cell culture development, where it has significant potential to be useful. In this work, we describe and demonstrate a low-cost benchtop system that can perform relaxometry measurements on 16 wells of a 96-well culture plate in one shot, enabling rapid, nondestructive scanning of multiple groups without any sample preparation. We demonstrate the application of this multiwell scanner for iron measurement and parallel measurements.
- Open Access
- 11 March 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (7) , 2368-2379
Intensified lentiviral vector perfusion bioprocessing with a spiral inertial microfluidic cell retention device
A spiral inertial microfluidic cell retention device enables high-density HEK293 perfusion bioprocessing for intensified lentiviral vector production, yielding functional titers up to 10 8 TU mL −1 through the device's harvest stream.
- 11 March 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (7) , 2368-2379
Open AccessIntensified lentiviral vector perfusion bioprocessing with a spiral inertial microfluidic cell retention device
A spiral inertial microfluidic cell retention device enables high-density HEK293 perfusion bioprocessing for intensified lentiviral vector production, yielding functional titers up to 10 8 TU mL −1 through the device's harvest stream.
- Open Access
- 31 January 2026
- Published by Elsevier in Bioresource Technology
- Vol. 446, 134139
More efficient iron enrichment in heterotrophic Auxenochlorella protothecoides by nitrogen source manipulation
- 31 January 2026
- Published by Elsevier in Bioresource Technology
- Vol. 446, 134139
Open AccessMore efficient iron enrichment in heterotrophic Auxenochlorella protothecoides by nitrogen source manipulation
- Open Access
- 26 January 2026
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 15 (2)
Cellular iron flux measurement by micromagnetic resonance relaxometry as a critical quality attribute of mesenchymal stromal cells
Background: Clinical application of mesenchymal stromal cells (MSCs) for cartilage regeneration has been hampered by their poor retention of chondrogenic potential during in vitro culture, which has led to highly variable cartilage repair outcomes. Consequently, there is an urgent need for a reliable assay to predict MSC chondrogenic potential during cell manufacturing. Methods: In this study, we developed a nondestructive MSCs iron flux monitoring methodology using spent culture media, utilizing micromagnetic resonance relaxometry (µMRR). We demonstrated that the dynamics of iron uptake and release by MSCs in culture can be reliably inferred from iron concentration changes in culture medium, with an unprecedented temporal resolution (<1 hour). Results: Analysis of 3 MSC donors across 6 independent culture batches revealed a significant correlation between iron homeostasis (iron flux during culture) and chondrogenic differentiation outcomes, while a departure from iron homeostasis (significant iron uptake and accumulation) was correlated with impaired chondrogenesis. By contrast, cell proliferation, although essential for manufacturing to achieve sufficient cell numbers, did not reliably correlate with chondrogenic capacity. Furthermore, ascorbic acid supplementation during culture, which is known to promote MSCs proliferation and chondrogenic quality, regulated iron homeostasis by limiting iron flux. Conclusion: Our findings identify iron homeostasis as a potential chondrogenic-associated critical quality attribute of MSCs. This rapid, nondestructive monitoring strategy offers a promising approach to improve manufacturing efficiency and consistency by providing real-time insight into cellular iron flux. In addition, the methodology here impacts broader iron biology by providing a time-resolved iron flux measurement that is not currently available.
- 26 January 2026
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 15 (2)
Open AccessCellular iron flux measurement by micromagnetic resonance relaxometry as a critical quality attribute of mesenchymal stromal cells
Background: Clinical application of mesenchymal stromal cells (MSCs) for cartilage regeneration has been hampered by their poor retention of chondrogenic potential during in vitro culture, which has led to highly variable cartilage repair outcomes. Consequently, there is an urgent need for a reliable assay to predict MSC chondrogenic potential during cell manufacturing. Methods: In this study, we developed a nondestructive MSCs iron flux monitoring methodology using spent culture media, utilizing micromagnetic resonance relaxometry (µMRR). We demonstrated that the dynamics of iron uptake and release by MSCs in culture can be reliably inferred from iron concentration changes in culture medium, with an unprecedented temporal resolution (<1 hour). Results: Analysis of 3 MSC donors across 6 independent culture batches revealed a significant correlation between iron homeostasis (iron flux during culture) and chondrogenic differentiation outcomes, while a departure from iron homeostasis (significant iron uptake and accumulation) was correlated with impaired chondrogenesis. By contrast, cell proliferation, although essential for manufacturing to achieve sufficient cell numbers, did not reliably correlate with chondrogenic capacity. Furthermore, ascorbic acid supplementation during culture, which is known to promote MSCs proliferation and chondrogenic quality, regulated iron homeostasis by limiting iron flux. Conclusion: Our findings identify iron homeostasis as a potential chondrogenic-associated critical quality attribute of MSCs. This rapid, nondestructive monitoring strategy offers a promising approach to improve manufacturing efficiency and consistency by providing real-time insight into cellular iron flux. In addition, the methodology here impacts broader iron biology by providing a time-resolved iron flux measurement that is not currently available.
- Open Access
- 7 July 2025
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 10 (6) , e70043
Ex vivo single‐cell profiling of acute myocardial infarction patients reveals disproportionate CD66b + cell secretion response
Acute myocardial infarction (AMI), a leading cause of death globally, triggers complex inflammatory responses critical to patient outcomes. However, rapid tools for profiling immune responses at the single‐cell level are lacking. The integrated Single‐cell Enzyme and Antigen Quantification (iSEAQ) system addresses this gap by enabling high‐throughput, single‐cell analysis of immune cell activity using just 20 μL of blood. This novel tool processes live CD66b and CD3 cells to quantify the secretion of Granzyme B, Neutrophil Elastase, and CD31 within minutes. Longitudinal studies on nine AMI patients revealed that CD66b + cells are major contributors (up to 95%) to key inflammatory enzymes, including the unexpected secretion of Granzyme B. iSEAQ achieves unparalleled sensitivity (0.4 fg/cell) and predictive accuracy (>90%) for patient profiling across AMI onset, treatment, and discharge. This innovation provides clinicians with a rapid, precise method to monitor immune responses, unveiling new insights into AMI inflammation and therapy.
- 7 July 2025
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 10 (6) , e70043
Open AccessEx vivo single‐cell profiling of acute myocardial infarction patients reveals disproportionate CD66b + cell secretion response
Acute myocardial infarction (AMI), a leading cause of death globally, triggers complex inflammatory responses critical to patient outcomes. However, rapid tools for profiling immune responses at the single‐cell level are lacking. The integrated Single‐cell Enzyme and Antigen Quantification (iSEAQ) system addresses this gap by enabling high‐throughput, single‐cell analysis of immune cell activity using just 20 μL of blood. This novel tool processes live CD66b and CD3 cells to quantify the secretion of Granzyme B, Neutrophil Elastase, and CD31 within minutes. Longitudinal studies on nine AMI patients revealed that CD66b + cells are major contributors (up to 95%) to key inflammatory enzymes, including the unexpected secretion of Granzyme B. iSEAQ achieves unparalleled sensitivity (0.4 fg/cell) and predictive accuracy (>90%) for patient profiling across AMI onset, treatment, and discharge. This innovation provides clinicians with a rapid, precise method to monitor immune responses, unveiling new insights into AMI inflammation and therapy.
- 2 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (27) , 14142-14149
Rapid Determination of Iron in Serum and Plasma Using Micromagnetic Resonance Relaxometry (μMRR)
Conventional iron determination methods, such as colorimetric assays, often lack sensitivity at low iron levels and are susceptible to interference from complex compositions in serum and plasma. In this study, we developed a rapid, sensitive, and accurate method for iron determination in 1 min utilizing an inexpensive benchtop 0.5-T micromagnetic resonance relaxometry (μMRR) system with acidification treatment of samples (pH < 1). The method yielded a highly linear calibration curve (R2 > 0.999) between the transverse relaxation rate R2 and iron concentration from 0.5 to 1000 μM, with a limit of detection (LOD) of 0.25 μM and a minimal assay volume of 5 μL. The accuracy of this method was validated by inductively coupled plasma mass spectrometry (ICP-MS) across a diverse range of biological samples. This μMRR-based approach offers a rapid and convenient alternative for serum and plasma iron measurements, which can substantially reduce clinical diagnostic time and support real-time iron monitoring for patients.
- 2 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (27) , 14142-14149
Rapid Determination of Iron in Serum and Plasma Using Micromagnetic Resonance Relaxometry (μMRR)
Conventional iron determination methods, such as colorimetric assays, often lack sensitivity at low iron levels and are susceptible to interference from complex compositions in serum and plasma. In this study, we developed a rapid, sensitive, and accurate method for iron determination in 1 min utilizing an inexpensive benchtop 0.5-T micromagnetic resonance relaxometry (μMRR) system with acidification treatment of samples (pH < 1). The method yielded a highly linear calibration curve (R2 > 0.999) between the transverse relaxation rate R2 and iron concentration from 0.5 to 1000 μM, with a limit of detection (LOD) of 0.25 μM and a minimal assay volume of 5 μL. The accuracy of this method was validated by inductively coupled plasma mass spectrometry (ICP-MS) across a diverse range of biological samples. This μMRR-based approach offers a rapid and convenient alternative for serum and plasma iron measurements, which can substantially reduce clinical diagnostic time and support real-time iron monitoring for patients.