Periklis Papadopoulos
Research Subjects
Research Interests
Periklis Papadopoulos has a total of 167 co-authors. Here are the top co-authors by number of shared publications:
- Hans-Jürgen Butt
Max Planck Institute for Polymer Research Mainz Germany
30 shared publications - Doris Vollmer
Physics at Interfaces, Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany
29 shared publications Friedrich Kremer
Institute of Experimental Physics I, Linnéstr. 5, University of Leipzig, 04103 Leipzig, Germany
14 shared publications- Xu Deng
Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu 610054, China
11 shared publications G. Floudas
Dept. of Physics and Biomedical Research Institute BRI-FORTH
9 shared publicationsLena Mammen
Max Planck Institute for Polymer Research, Ackermannweg 10, D-55128, Mainz, Germany.
9 shared publications
Latest Publications
- Open Access
- 14 May 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (20) , 18902-18928
Drop Friction and Failure on Superhydrophobic and Slippery Surfaces
The mobility of drops on a surface influences how much water and energy is required to clean the surface. By controlling drop mobility, it is possible to promote or reduce fogging, icing, and fouling. Superhydrophobic and slippery liquid-infused surfaces both display high drop mobility despite being 'lubricated' by fluids having very different viscosities. Superhydrophobic surfaces rely on micro- and/or nanoscale textures to trap air pockets beneath drops, minimizing solid-liquid contact. In contrast, on liquid-infused surfaces, these solid textures are filled with an immiscible liquid lubricant. Over the past few years, innovations in experimental and computational methods have provided detailed new insights into the static and dynamic wetting properties of drops on these surfaces. In this review, we describe the criteria needed to obtain stable wetting states with low drop friction and high mobility on both surfaces, and discuss the mechanisms that have been proposed to explain the origins of friction on each surface. Drops can collapse from the low-friction Cassie state to the high-friction Wenzel state on both surfaces, but the transition follows different pathways: on liquid-infused surfaces, the wetting ridge near the drop edge plays a central role in triggering collapse, a phenomenon not observed on superhydrophobic surfaces. This review emphasizes that a liquid-infused surface cannot be simply viewed as a superhydrophobic surface with the air pockets replaced by lubricant. The wetting ridge surrounding drops on liquid-infused surfaces significantly alters most of the drop's properties, including macroscopic shape, friction mechanisms, and the mechanism of collapse to a Wenzel state.
- 14 May 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (20) , 18902-18928
Open AccessDrop Friction and Failure on Superhydrophobic and Slippery Surfaces
The mobility of drops on a surface influences how much water and energy is required to clean the surface. By controlling drop mobility, it is possible to promote or reduce fogging, icing, and fouling. Superhydrophobic and slippery liquid-infused surfaces both display high drop mobility despite being 'lubricated' by fluids having very different viscosities. Superhydrophobic surfaces rely on micro- and/or nanoscale textures to trap air pockets beneath drops, minimizing solid-liquid contact. In contrast, on liquid-infused surfaces, these solid textures are filled with an immiscible liquid lubricant. Over the past few years, innovations in experimental and computational methods have provided detailed new insights into the static and dynamic wetting properties of drops on these surfaces. In this review, we describe the criteria needed to obtain stable wetting states with low drop friction and high mobility on both surfaces, and discuss the mechanisms that have been proposed to explain the origins of friction on each surface. Drops can collapse from the low-friction Cassie state to the high-friction Wenzel state on both surfaces, but the transition follows different pathways: on liquid-infused surfaces, the wetting ridge near the drop edge plays a central role in triggering collapse, a phenomenon not observed on superhydrophobic surfaces. This review emphasizes that a liquid-infused surface cannot be simply viewed as a superhydrophobic surface with the air pockets replaced by lubricant. The wetting ridge surrounding drops on liquid-infused surfaces significantly alters most of the drop's properties, including macroscopic shape, friction mechanisms, and the mechanism of collapse to a Wenzel state.
- 3 June 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (26) , 13422-13427
Transition of Liquid Drops on Microstructured Hygrophobic Surfaces from the Impaled Wenzel State to the “Fakir” Cassie–Baxter State
Low adhesion of liquids on solid surfaces can be achieved with protrusions that minimize the contact area between the liquid and the solid. The wetting state where an air cushion forms under the drop is known as the Cassie-Baxter state. Surfaces where liquids form macroscopic contact angles above 150° are called superhydrophobic and superhygrophobic, if we refer to water or any liquid, respectively. The Cassie state is desirable for applications, but it is usually unstable compared to the Wenzel state, where the drop is in direct contact with the rough surface. The Cassie-to-Wenzel transition can be triggered by an increase in pressure and vibrations, but the inverse Wenzel-to-Cassie is much more difficult to observe. Here, we examine under what conditions the Wenzel-to-Cassie transition is triggered when the microscopic contact angle changes abruptly. For this, we applied a lubricant of low surface tension around drops that were in the Wenzel state on microstructured surfaces. The increase of the microscopic contact angle lifted the drop from the rough surface, when the pillar height and spacing are large and small, respectively. Numerical calculations for the drop-lubricant interface showed that the surface geometry requirements for the Wenzel-to-Cassie transition are stricter than the ones for the stability of the Cassie state. A surface geometry where the Cassie state is more stable than the Wenzel for a given Laplace pressure of the drop may not always allow the Wenzel-to-Cassie transition to take place. Therefore, the stability of the Cassie state is a necessary but insufficient condition for the inverse transition.
- 3 June 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (26) , 13422-13427
Transition of Liquid Drops on Microstructured Hygrophobic Surfaces from the Impaled Wenzel State to the “Fakir” Cassie–Baxter State
Low adhesion of liquids on solid surfaces can be achieved with protrusions that minimize the contact area between the liquid and the solid. The wetting state where an air cushion forms under the drop is known as the Cassie-Baxter state. Surfaces where liquids form macroscopic contact angles above 150° are called superhydrophobic and superhygrophobic, if we refer to water or any liquid, respectively. The Cassie state is desirable for applications, but it is usually unstable compared to the Wenzel state, where the drop is in direct contact with the rough surface. The Cassie-to-Wenzel transition can be triggered by an increase in pressure and vibrations, but the inverse Wenzel-to-Cassie is much more difficult to observe. Here, we examine under what conditions the Wenzel-to-Cassie transition is triggered when the microscopic contact angle changes abruptly. For this, we applied a lubricant of low surface tension around drops that were in the Wenzel state on microstructured surfaces. The increase of the microscopic contact angle lifted the drop from the rough surface, when the pillar height and spacing are large and small, respectively. Numerical calculations for the drop-lubricant interface showed that the surface geometry requirements for the Wenzel-to-Cassie transition are stricter than the ones for the stability of the Cassie state. A surface geometry where the Cassie state is more stable than the Wenzel for a given Laplace pressure of the drop may not always allow the Wenzel-to-Cassie transition to take place. Therefore, the stability of the Cassie state is a necessary but insufficient condition for the inverse transition.
- Open Access
- 10 March 2021
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 17 (16) , 4335-4341
Impact of substrate elasticity on contact angle saturation in electrowetting
Soft and thin dielectrics favor contact angle saturation in electrowetting. Experiments are supported by detailed numerical computations of the electric field and stress distribution.
- 10 March 2021
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 17 (16) , 4335-4341
Open AccessImpact of substrate elasticity on contact angle saturation in electrowetting
Soft and thin dielectrics favor contact angle saturation in electrowetting. Experiments are supported by detailed numerical computations of the electric field and stress distribution.
- Open Access
- 27 June 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Checking for voice disorders without clinical intervention: The Greek and global VHI thresholds for voice disordered patients
Voice disorders often remain undiagnosed. Many self-perceived questionnaires exist for various medical conditions. Here, we used the Greek Voice Handicap Index (VHI) to address the aforementioned problem. Everyone can fill in the VHI questionnaire and rate their symptoms easily. The innovative feature of this research is the global cut-off score calculated for the VHI. Therefore, the VHI is now capable of helping clinicians establish a more customizable treatment plan with the cut-off point identifying patients without normal phonation. For the purpose of finding the global cut-off point, a group of 180 participants was recruited in Greece (90 non-dysphonic participants and 90 with different types of dysphonia). The voice disordered group had higher VHI scores than those of the control group. In contrast to previous studies, we provided and validated for the first time the cut-off points for all VHI domains and, finally, a global cut-off point through ROC and precision-recall analysis in a voice disordered population. In practice, a score higher than the well-estimated global score indicates (without intervention) a possible voice disorder. Nevertheless, if the score is near the threshold, then the patient should definitely follow preventive measures.
- 27 June 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessChecking for voice disorders without clinical intervention: The Greek and global VHI thresholds for voice disordered patients
Voice disorders often remain undiagnosed. Many self-perceived questionnaires exist for various medical conditions. Here, we used the Greek Voice Handicap Index (VHI) to address the aforementioned problem. Everyone can fill in the VHI questionnaire and rate their symptoms easily. The innovative feature of this research is the global cut-off score calculated for the VHI. Therefore, the VHI is now capable of helping clinicians establish a more customizable treatment plan with the cut-off point identifying patients without normal phonation. For the purpose of finding the global cut-off point, a group of 180 participants was recruited in Greece (90 non-dysphonic participants and 90 with different types of dysphonia). The voice disordered group had higher VHI scores than those of the control group. In contrast to previous studies, we provided and validated for the first time the cut-off points for all VHI domains and, finally, a global cut-off point through ROC and precision-recall analysis in a voice disordered population. In practice, a score higher than the well-estimated global score indicates (without intervention) a possible voice disorder. Nevertheless, if the score is near the threshold, then the patient should definitely follow preventive measures.
- Open Access
- 5 September 2018
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 14 (36) , 7429-7434
Wetting of soft superhydrophobic micropillar arrays
We image the bending of soft micropillars as liquid drops move on them and calculate the forces hindering drop motion.
- 5 September 2018
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 14 (36) , 7429-7434
Open AccessWetting of soft superhydrophobic micropillar arrays
We image the bending of soft micropillars as liquid drops move on them and calculate the forces hindering drop motion.
- 27 July 2018
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 121 (4) , 048002
Detaching Microparticles from a Liquid Surface
The work required to detach microparticles from fluid interfaces depends on the shape of the liquid meniscus. However, measuring the capillary force on a single microparticle and simultaneously imaging the shape of the liquid meniscus has not yet been accomplished. To correlate force and shape, we combined a laser scanning confocal microscope with a colloidal probe setup. While moving a hydrophobic microsphere (radius ) in and out of a thick glycerol film, we simultaneously measured the force and imaged the shape of the liquid meniscus. In this way we verified the fundamental equations [D. F. James, J. Fluid Mech. 63, 657 (1974); A. D. Scheludko, A. D. Nikolov, Colloid Polymer Sci. 253, 396 (1975)] that describe the adhesion of particles in flotation, deinking of paper, the stability of Pickering emulsions and particle-stabilized foams. Comparing experimental results with theory showed, however, that the receding contact angle has to be applied, which can be much lower than the static contact angle obtained right after jump in of the particle.- 27 July 2018
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 121 (4) , 048002
Detaching Microparticles from a Liquid Surface
The work required to detach microparticles from fluid interfaces depends on the shape of the liquid meniscus. However, measuring the capillary force on a single microparticle and simultaneously imaging the shape of the liquid meniscus has not yet been accomplished. To correlate force and shape, we combined a laser scanning confocal microscope with a colloidal probe setup. While moving a hydrophobic microsphere (radius ) in and out of a thick glycerol film, we simultaneously measured the force and imaged the shape of the liquid meniscus. In this way we verified the fundamental equations [D. F. James, J. Fluid Mech. 63, 657 (1974); A. D. Scheludko, A. D. Nikolov, Colloid Polymer Sci. 253, 396 (1975)] that describe the adhesion of particles in flotation, deinking of paper, the stability of Pickering emulsions and particle-stabilized foams. Comparing experimental results with theory showed, however, that the receding contact angle has to be applied, which can be much lower than the static contact angle obtained right after jump in of the particle.- Open Access
- 4 May 2017
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 13 (20) , 3760-3767
Shape of a sessile drop on a flat surface covered with a liquid film
Motivated by the development of lubricant-infused slippery surfaces, we study a sessile drop of a nonvolatile (ionic) liquid which is embedded in a slowly evaporating lubricant film (n-decane) on a horizontal, planar solid substrate. Using laser scanning confocal microscopy we imaged the evolution of the shape of the liquid/liquid and liquid/air interfaces, including the angles between them. Results are compared to solutions of the generalized Laplace equations describing the drop profile and the annular wetting ridge. For all film thicknesses, experimental results agree quantitatively with the calculated drop and film shapes. With the verified theory we can predict height and volume of the wetting ridge. Two regimes can be distinguished: for macroscopically thick films (excess lubrication) the meniscus size is insensitive to changes in film thickness. Once the film is thin enough that surface forces between the lubricant/air and solid/lubricant interfaces become significant the meniscus changes significantly with varying film thickness (starved lubrication). The size of the meniscus is particularly relevant because it affects sliding angles of drops on lubricant-infused surfaces.
- 4 May 2017
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 13 (20) , 3760-3767
Open AccessShape of a sessile drop on a flat surface covered with a liquid film
Motivated by the development of lubricant-infused slippery surfaces, we study a sessile drop of a nonvolatile (ionic) liquid which is embedded in a slowly evaporating lubricant film (n-decane) on a horizontal, planar solid substrate. Using laser scanning confocal microscopy we imaged the evolution of the shape of the liquid/liquid and liquid/air interfaces, including the angles between them. Results are compared to solutions of the generalized Laplace equations describing the drop profile and the annular wetting ridge. For all film thicknesses, experimental results agree quantitatively with the calculated drop and film shapes. With the verified theory we can predict height and volume of the wetting ridge. Two regimes can be distinguished: for macroscopically thick films (excess lubrication) the meniscus size is insensitive to changes in film thickness. Once the film is thin enough that surface forces between the lubricant/air and solid/lubricant interfaces become significant the meniscus changes significantly with varying film thickness (starved lubrication). The size of the meniscus is particularly relevant because it affects sliding angles of drops on lubricant-infused surfaces.
- 21 December 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 33 (1) , 107-116
Energy Dissipation of Moving Drops on Superhydrophobic and Superoleophobic Surfaces
A water drop moving on a superhydrophobic surface or an oil drop moving on a superoleophobic surface dissipates energy by pinning/depinning at nano- and microprotrusions. Here, we calculate the work required to form, extend, and rupture capillary bridges between the protrusions and the drop. The energy dissipated at one protrusion WS is derived from the observable apparent receding contact angle Θrapp and the density of protrusions n by Ws = γ(cos Θrapp + 1)/n, where γ is the surface tension of the liquid. To derive an expression for Ws that links the microscopic structure of the surface to apparent contact angles, two models are considered: A superhydrophobic array of cylindrical micropillars and a superoleophobic array of stacks of microspheres. For a radius of a protrusion R and a receding materials contact angle Θr, we calculate the energy dissipated per protrusion as Ws = πγR2[A – ln(R/κ)]f(Θr). Here, A = 0.60 for cylindrical micropillars and 2.9 for stacks of spheres. κ is the capillary length. f(Θr) is a function which depends on Θr and the specific geometry, f ranges from ≈0.25 to 0.96. Combining both equations above, we can correlate the macroscopically observed apparent receding contact angle with the microscopic structure of the surface and its material properties.
- 21 December 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 33 (1) , 107-116
Energy Dissipation of Moving Drops on Superhydrophobic and Superoleophobic Surfaces
A water drop moving on a superhydrophobic surface or an oil drop moving on a superoleophobic surface dissipates energy by pinning/depinning at nano- and microprotrusions. Here, we calculate the work required to form, extend, and rupture capillary bridges between the protrusions and the drop. The energy dissipated at one protrusion WS is derived from the observable apparent receding contact angle Θrapp and the density of protrusions n by Ws = γ(cos Θrapp + 1)/n, where γ is the surface tension of the liquid. To derive an expression for Ws that links the microscopic structure of the surface to apparent contact angles, two models are considered: A superhydrophobic array of cylindrical micropillars and a superoleophobic array of stacks of microspheres. For a radius of a protrusion R and a receding materials contact angle Θr, we calculate the energy dissipated per protrusion as Ws = πγR2[A – ln(R/κ)]f(Θr). Here, A = 0.60 for cylindrical micropillars and 2.9 for stacks of spheres. κ is the capillary length. f(Θr) is a function which depends on Θr and the specific geometry, f ranges from ≈0.25 to 0.96. Combining both equations above, we can correlate the macroscopically observed apparent receding contact angle with the microscopic structure of the surface and its material properties.
- 4 October 2016
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 145 (13) , 134703
The Cassie-Wenzel transition of fluids on nanostructured substrates: Macroscopic force balance versus microscopic density-functional theory
Classical density functional theory is applied to investigate the validity of a phenomenological force-balance description of the stability of the Cassie state of liquids on substrates with nanoscale corrugation. A bulk free-energy functional of third order in local density is combined with a square-gradient term, describing the liquid-vapor interface. The bulk free energy is parameterized to reproduce the liquid density and the compressibility of water. The square-gradient term is adjusted to model the width of the water-vapor interface. The substrate is modeled by an external potential, based upon the Lennard-Jones interactions. The three-dimensional calculation focuses on substrates patterned with nanostripes and square-shaped nanopillars. Using both the force-balance relation and density-functional theory, we locate the Cassie-to-Wenzel transition as a function of the corrugation parameters. We demonstrate that the force-balance relation gives a qualitatively reasonable description of the transition even on the nanoscale. The force balance utilizes an effective contact angle between the fluid and the vertical wall of the corrugation to parameterize the impalement pressure. This effective angle is found to have values smaller than the Young contact angle. This observation corresponds to an impalement pressure that is smaller than the value predicted by macroscopic theory. Therefore, this effective angle embodies effects specific to nanoscopically corrugated surfaces, including the finite range of the liquid-solid potential (which has both repulsive and attractive parts), line tension, and the finite interface thickness. Consistently with this picture, both patterns (stripes and pillars) yield the same effective contact angles for large periods of corrugation.
- 4 October 2016
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 145 (13) , 134703
The Cassie-Wenzel transition of fluids on nanostructured substrates: Macroscopic force balance versus microscopic density-functional theory
Classical density functional theory is applied to investigate the validity of a phenomenological force-balance description of the stability of the Cassie state of liquids on substrates with nanoscale corrugation. A bulk free-energy functional of third order in local density is combined with a square-gradient term, describing the liquid-vapor interface. The bulk free energy is parameterized to reproduce the liquid density and the compressibility of water. The square-gradient term is adjusted to model the width of the water-vapor interface. The substrate is modeled by an external potential, based upon the Lennard-Jones interactions. The three-dimensional calculation focuses on substrates patterned with nanostripes and square-shaped nanopillars. Using both the force-balance relation and density-functional theory, we locate the Cassie-to-Wenzel transition as a function of the corrugation parameters. We demonstrate that the force-balance relation gives a qualitatively reasonable description of the transition even on the nanoscale. The force balance utilizes an effective contact angle between the fluid and the vertical wall of the corrugation to parameterize the impalement pressure. This effective angle is found to have values smaller than the Young contact angle. This observation corresponds to an impalement pressure that is smaller than the value predicted by macroscopic theory. Therefore, this effective angle embodies effects specific to nanoscopically corrugated surfaces, including the finite range of the liquid-solid potential (which has both repulsive and attractive parts), line tension, and the finite interface thickness. Consistently with this picture, both patterns (stripes and pillars) yield the same effective contact angles for large periods of corrugation.
- 27 September 2016
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 49 (19) , 7400-7414
Interfacial Energy and Glass Temperature of Polymers Confined to Nanoporous Alumina
- 27 September 2016
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 49 (19) , 7400-7414
Interfacial Energy and Glass Temperature of Polymers Confined to Nanoporous Alumina