JSJosep Sulé-Suso

Josep Sulé-Suso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Josep Sulé-Suso has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fourier Transform Infrared Microspectroscopy as a Liquid Biopsy Tool to Detect Single Circulating Tumour Cells in the Blood of a Lung Cancer Patient

    by Lewis Dowling, Charlotte Evans, Paul Roach, Lisa Vaccari, Gianfelice Cinque, Chiaramaria Stani, Giovanni Birarda, Vishnu Anand Muruganandan, Srinivas Pillai, Daniel Gey van Pittius, et al.

    Liquid biopsy is revolutionizing cancer management, with circulating tumor cells (CTCs), offering a transformative approach to screening, diagnosis, and treatment monitoring. However, existing CTC isolation methods relying on antigen expression or physical properties lack robustness, are operator-dependent, and suffer from automation challenges, leading to inconsistent and time-intensive analyses. A universal, unbiased methodology for CTC detection across tumor types is critically needed. Here, we present the first proof-of-concept study demonstrating the use of Fourier transform infrared (FT-IR) microspectroscopy to study cytospun blood samples coupled with a random forest (RF) classifier, for the detection of a single CTC in the blood of a lung cancer patient as confirmed via immunohistochemistry. Notably, our method utilizes glass coverslips as substrates, routinely employed in pathology departments, enabling seamless integration with histopathological analyses (e.g., staining, immunohistochemistry). Using FT-IR spectral data from in vitro growing lung cancer cells as a training model, we achieved precise CTC identification based on biochemical composition, specifically within the fingerprint region (1800 cm –1 to 1350 cm –1 ). This study introduces FT-IR microspectroscopy as a novel, label-free approach for CTCs detection in liquid biopsies, with the potential to redefine cancer diagnostics. By enhancing precision and accessibility in CTC identification, the clinical implementation of this methodology may represent a significant advancement in personalized oncology, offering a clinically viable tool for real-time cancer monitoring and improved patient stratification.

  • Open Access

    Fourier Transform Infrared microspectroscopy identifies single cancer cells in blood. A feasibility study towards liquid biopsy

    by Lewis M. Dowling, Paul Roach, Eirik A. Magnussen, Achim Kohler, Srinivas Pillai, Daniel G. van Pittius, Ibraheem Yousef, Josep Sulé-Suso

    The management of cancer patients has markedly improved with the advent of personalised medicine where treatments are given based on tumour antigen expression amongst other. Within this remit, liquid biopsies will no doubt improve this personalised cancer management. Identifying circulating tumour cells in blood allows a better assessment for tumour screening, staging, response to treatment and follow up. However, methods to identify/capture these circulating tumour cells using cancer cells’ antigen expression or their physical properties are not robust enough. Thus, a methodology that can identify these circulating tumour cells in blood regardless of the type of tumour is highly needed. Fourier Transform Infrared (FTIR) microspectroscopy, which can separate cells based on their biochemical composition, could be such technique. In this feasibility study, we studied lung cancer cells (squamous cell carcinoma and adenocarcinoma) mixed with peripheral blood mononuclear cells (PBMC). The data obtained shows, for the first time, that FTIR microspectroscopy together with Random Forest classifier is able to identify a single lung cancer cell in blood. This separation was easier when the region of the IR spectra containing lipids and the amide A (2700 to 3500 cm-1) was used. Furthermore, this work was carried out using glass coverslips as substrates that are widely used in pathology departments. This allows further histopathological cell analysis (staining, immunohistochemistry, …) after FTIR spectra are obtained. Hence, although further work is needed using blood samples from patients with cancer, FTIR microspectroscopy could become another tool to be used in liquid biopsies for the identification of circulating tumour cells, and in the personalised management of cancer.


  • Open Access

    Detection of lipid efflux from foam cell models using a label-free infrared method

    by Bowen Xie, Wanjiku Njoroge, Lewis M. Dowling, Josep Sulé-Suso, Gianfelice Cinque, Ying Yang

    Cardiovascular diseases are still among the leading causes of mortality and morbidity worldwide. The build-up of fatty plaques in the arteries, leading to atherosclerosis, is the most common cause of cardiovascular diseases. The central player in atherosclerotic plaque formation is the foam cell. Foam cells are formed when monocytes infiltrate from the blood stream into the sub-endothelial space, differentiating into macrophages. With the subsequent uptake and storage of lipoprotein, especially low-density lipoprotein (LDL), they change their phenotype to lipid laden cells. Lowering circulating LDL levels, or initiating cholesterol efflux/reverse cholesterol transport in foam cells, is one of the current clinical therapies. Prescription of the pleiotropic drugs, statins, is the most successful therapy for the treatment and prevention of atherosclerosis. In this study, we used a foam cell model from the macrophage cell line, RAW 246.7, and applied the label-free Fourier Transform Infrared Spectroscopy (FTIR) method, i.e. synchrotron-based microFTIR spectroscopy, to study the lipid efflux process initiated by statins in a dose and time dependent manner. We used glass coverslips as substrates for IR analysis. The optical images (visible and fluorescent light) clearly identify the localization and lipid distribution within the foam cells, and the associated changes before and after culturing them with atorvastatin at concentrations of 0.6, 6 and 60 μg mL−1, for a culture duration between 24 to 72 hours. MicroFTIR spectroscopic spectra uniquely displayed the reduction of lipid content, with higher lipid efflux observed at higher doses of, and longer incubation time with, atorvastatin. Principal Component Analysis (PCA) and t-distributed Stochastic Neighbor Embedding (t-SNE) analysis demonstrated defined cluster separation at both lipid (3000–2800 cm−1) and fingerprint (1800–1350 cm−1) regions, with more profound discrimination for the atorvastatin dose treatment than time treatment. The data indicate that combining synchrotron-based microFTIR spectroscopy and using glass substrates for foam cells can offer an alternative tool in atherosclerosis investigation at a molecular level, and through cell morphology.


  • Optical Photothermal Infrared Microspectroscopy Discriminates for the First Time Different Types of Lung Cells on Histopathology Glass Slides

    by Mustafa Kansiz, Lewis M. Dowling, Ibraheem Yousef, Olivier Guaitella, Ferenc Borondics, Josep Sulé-Suso

    The debate of whether a glass substrate can be used in Fourier transform infrared spectroscopy is strongly linked to its potential clinical application. Histopathology glass slides of 1 mm thickness absorb the mid-IR spectrum in the rich fingerprint spectral region. Thus, it is important to assess whether emerging IR techniques can be employed to study biological samples placed on glass substrates. For this purpose, we used optical photothermal infrared (O-PTIR) spectroscopy to study for the first time malignant and non-malignant lung cells with the purpose of identifying IR spectral differences between these cells placed on standard pathology glass slides. The data in this feasibility study showed that O-PTIR can be used to obtain good-quality IR spectra from cells from both the lipid region (3000–2700 cm–1) and the fingerprint region between 1770 and 950 cm–1 but with glass contributions from 1350 to 950 cm–1. A new single-unit dual-range (C–H/FP) quantum cascade laser (QCL) IR pump source was applied for the first time, delivering a clear synergistic benefit to the classification results. Furthermore, O-PTIR is able to distinguish between lung cancer cells and non-malignant lung cells both in the lipid and fingerprint regions. However, when these two spectral ranges are combined, classification accuracies are enhanced with Random Forest modeling classification accuracy results ranging from 96 to 99% across all three studied cell lines. The methodology described here for the first time with a single-unit dual-range QCL for O-PTIR on glass is another step toward its clinical application in pathology.


  • Open Access

    Optimization of Sample Preparation Using Glass Slides for Spectral Pathology

    by Lewis M. Dowling, Paul Roach, Abigail V. Rutter, Ibraheem Yousef, Srinivas Pillai, Deborah Latham, Daniel G. van Pittius, Josep Sulé-Suso

    The clinical translation of Fourier transform infrared (FT-IR) microspectroscopy in pathology will require bringing this technique as close as possible to standard practice in pathology departments. An important step is sample preparation for both FT-IR microspectroscopy and pathology. This should entail minimal disruption of standard clinical practice while achieving good quality FT-IR spectral data. In fact, the recently described possibility of obtaining FT-IR spectra of cells placed on glass substrates brings FT-IR microspectroscopy closer to a clinical application. We have now furthered this work in order to identify two different types of lung cancer cells placed on glass coverslips. Two types of sample preparation which are widely used in pathology, cytospin and smear, have been used. Samples were fixed with either methanol, used in pathology, or formalin (4% paraformaldehyde) used widely in spectroscopy. Fixation with methanol (alcohol-based fixative) removed lipids from cells causing a decrease in intensity of the peaks at 2850 cm −1 and 2920 cm −1 . Nevertheless, we show for the first time that using either type of sample preparation and fixation on thin glass coverslips allowed to differentiate between two different types of lung cancer cells using either the lipid region or the fingerprint region ranging from 1800 cm −1 to 1350 cm −1 . We believe that formalin-fixed cytospin samples would be preferred to study cells on thin coverslips using FT-IR microspectroscopy. This work presents a clear indication for future advances in clinical assessment of samples within pathology units to gain a deeper understanding of cells/tissues under investigation.


  • Open Access

    Identification of a Glass Substrate to Study Cells Using Fourier Transform Infrared Spectroscopy: Are We Closer to Spectral Pathology?

    by Abigail V. Rutter, Jamie Crees, Helen Wright, Marko Raseta, Daniel G. van Pittius, Paul Roach, Josep Sulé-Suso

    The rising incidence of cancer worldwide is causing an increase in the workload in pathology departments. This, coupled with advanced analysis methodologies, supports a developing need for techniques that could identify the presence of cancer cells in cytology and tissue samples in an objective, fast, and automated way. Fourier transform infrared (FT-IR) microspectroscopy can identify cancer cells in such samples objectively. Thus, it has the potential to become another tool to help pathologists in their daily work. However, one of the main drawbacks is the use of glass substrates by pathologists. Glass absorbs IR radiation, removing important mid-IR spectral data in the fingerprint region (1800 cm −1 to 900 cm −1 ). In this work, we hypothesized that, using glass coverslips of differing compositions, some regions within the fingerprint area could still be analyzed. We studied three different types of cells (peripheral blood mononuclear cells, a leukemia cell line, and a lung cancer cell line) and lymph node tissue placed on four different types of glass coverslips. The data presented here show that depending of the type of glass substrate used, information within the fingerprint region down to 1350 cm −1 can be obtained. Furthermore, using principal component analysis, separation between the different cell lines was possible using both the lipid region and the fingerprint region between 1800 cm −1 and 1350 cm −1 . This work represents a further step towards the application of FT-IR microspectroscopy in histopathology departments.


  • Open Access

    Striking lung cancer response to self-administration of cannabidiol: A case report and literature review

    by Josep Sulé-Suso, Nick A Watson, Daniel G van Pittius, Apurna Jegannathen

    In spite of new drugs, lung cancer is associated with a very poor prognosis. While targeted therapies are improving outcomes, it is not uncommon for many patients to have only a partial response, and relapse during follow-up. Thus, new drugs or re-evaluation of existing therapies used to treat other non-malignant diseases (drug repurposing) are still needed. While this research both in vitro and in vivo is being carried out, it is important to be attentive to patients where the disease responds to treatments not considered standard in clinical practice. We report here a patient with adenocarcinoma of the lung who, after declining chemotherapy and radiotherapy, presented with tumour response following self-administration of cannabidiol, a non-psychoactive compound present in Cannabis sativa. Prior work has shown that cannabidiol may have anti-neoplastic properties and enhance the immune response to cancer. The data presented here indicate that cannabidiol might have led to a striking response in a patient with lung cancer.


  • Fourier transform infrared spectra of cells on glass coverslips. A further step in spectral pathology

    by A. V. Rutter, J. Crees, H. Wright, D. G. van Pittius, I. Yousef, J. Sulé-Suso

    Over the last few years, great effort has been placed on developing Fourier Transform Infrared (FTIR) microspectroscopy as a tool to help in the histopathological diagnosis of cancer. The ever increasing workload in pathology departments is calling for a technique that could identify the presence of cancer cells in cytology and tissue samples in an objective, fast and automated way. However, pathologists use glass slides which absorb infrared (IR) radiation thus removing important mid-IR spectral data in the fingerprint region (proteins, DNA, RNA; 1800 cm−1 to 900 cm−1). To this purpose, we hypothesised whether using thinner glass slides, i.e., glass coverslips, would allow us to obtain spectral data not only from the lipid region (3100 cm−1 to 2700 cm−1) but also from the fingerprint region. To this purpose, we studied peripheral blood mononuclear cells (PBMC), a leukaemia cell line (K562) and a lung cancer cell line (CALU-1). Cells were placed on DAKO coverslips and their FTIR spectra obtained at MIRAS beamline, Alba synchrotron light source (Barcelona, Catalonia). The data presented here not only shows for the first time that it is possible to obtain spectral data from most of the amide I region (1800 cm−1 to 1570 cm−1) of cells placed on glass coverslips but more important, principal component analysis was able to separate between the three types of cells for both the lipid and the amide I regions. The methodology here described is a further step in the application of FTIR microspectroscopy in histopathology departments.


  • Vibrational spectroscopic monitoring and biochemical analysis of pericellular matrix formation and maturation in a 3-dimensional chondrocyte culture model

    by H. A. Owida, A. V. Rutter, G. Cinque, N. J. Kuiper, J. Sulé-Suso, Y. Yang

    PCA score of FTIR spectra in fingerprint region for cultured chondrocytes at day 7, 14 and 21 in HA hydrogel showing that the 3D culture drove chondrocytes (CY) to chondron-like (CN) structure dynamically.


  • Top Cited Papers

    Clinical applications of infrared and Raman spectroscopy: state of play and future challenges

    by Matthew J. Baker, Hugh J. Byrne, John Chalmers, Peter Gardner, Royston Goodacre, Alex Henderson, Sergei G. Kazarian, Francis L. Martin, Julian Moger, Nick Stone, et al.

    Vibrational spectroscopies, based on infrared absorption and/or Raman scattering provide a detailed fingerprint of a material, based on the chemical content. Diagnostic and prognostic tools based on these technologies have the potential to revolutionise our clinical systems leading to improved patient outcome, more efficient public services and significant economic savings. However, despite these strong drivers, there are many fundamental scientific and technological challenges which have limited the implementation of this technology in the clinical arena, although recent years have seen significant progress in addressing these challenges. This review examines (i) the state of the art of clinical applications of infrared absorption and Raman spectroscopy, and (ii) the outstanding challenges, and progress towards translation, highlighting specific examples in the areas of in vivo, ex vivo and in vitro applications. In addition, the requirements of instrumentation suitable for use in the clinic, strategies for pre-processing and statistical analysis in clinical spectroscopy and data sharing protocols, will be discussed. Emerging consensus recommendations are presented, and the future perspectives of the field are assessed, particularly in the context of national and international collaborative research initiatives, such as the UK EPSRC Clinical Infrared and Raman Spectroscopy Network, the EU COST Action Raman4Clinics, and the International Society for Clinical Spectroscopy.