Peter B. Ortner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Peter B. Ortner has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Jia-Zhong Zhang
Ocean Chemistry and Ecosystems Division, Atlantic Oceanographic and Meteorological Laboratory, National Oceanic and Atmospheric Administration, Miami, USA
1 shared publication Natchanon Amornthammarong
Cooperative Institute for Marine and Atmospheric Studies (CIMAS), Rosenstiel School of Marine and Atmospheric Science, University of Miami, 4600 Rickenbacker Causeway, Miami, Florida, USA
1 shared publication
Latest Publications
- 2 June 2011
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (7) , 1501-1506
An autonomous batch analyzer for the determination of trace ammonium in natural waters using fluorometric detection
An autonomous batch analyzer (ABA) is described for the measurement of ammonium in natural waters. The system combines previously described batch analysis and continuous flow analysis methods. With its simpler design, the system is robust, flexible, inexpensive, and requires minimal maintenance. The sampling frequency is ca. 8 h−1 and the limit of detection ca. 1 nM which is comparable to the most sensitive flow through or batch analysis methods previously described. Reproducibility is 0.6% (n = 10) at an ammonium level of 200 nM. There are three working ranges: 5–1000 nM, 20–4000 nM, and 0.2–25 μM. In addition, the system produces a calibration curve by autodilution from a single stock standard solution with the same accuracy as traditional manual calibration methods. Representative field data and comparisons with standard EPA methods confirm the utility of the ABA.
- 2 June 2011
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (7) , 1501-1506
An autonomous batch analyzer for the determination of trace ammonium in natural waters using fluorometric detection
An autonomous batch analyzer (ABA) is described for the measurement of ammonium in natural waters. The system combines previously described batch analysis and continuous flow analysis methods. With its simpler design, the system is robust, flexible, inexpensive, and requires minimal maintenance. The sampling frequency is ca. 8 h−1 and the limit of detection ca. 1 nM which is comparable to the most sensitive flow through or batch analysis methods previously described. Reproducibility is 0.6% (n = 10) at an ammonium level of 200 nM. There are three working ranges: 5–1000 nM, 20–4000 nM, and 0.2–25 μM. In addition, the system produces a calibration curve by autodilution from a single stock standard solution with the same accuracy as traditional manual calibration methods. Representative field data and comparisons with standard EPA methods confirm the utility of the ABA.