Franco A. Bertolino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Franco A. Bertolino has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Julio Raba
Instituto de Química de San Luis (INQUISAL), Facultad de Química, Bioquímica y Farmacia (FQBF), Universidad Nacional de San Luis (UNSL), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), INQUISAL (UNSL—CONICET), Chacabuco 917, San Luis D5700BWS, Argentina
12 shared publications Germán A. Messina
INQUISAL, Departamento de Química, Universidad Nacional de San Luis, CONICET, Chacabuco 917, D5700BWS, San Luis, Argentina
11 shared publicationsJulio Raba
INQUISAL
10 shared publications- Matías Regiart
Instituto de Química de San Luis, Facultad de Química, Universidad Nacional de San Luis, INQUISAL (UNSL—CONICET), Ejército de los Andes 950, San Luis D5700BWS, Argentina
10 shared publications - Martin A. Fernandez Baldo
Instituto de Química de San Luis, Facultad de Química, Universidad Nacional de San Luis, INQUISAL (UNSL—CONICET), Ejército de los Andes 950, San Luis D5700BWS, Argentina
8 shared publications Sirley V. Pereira
7 shared publications
Latest Publications
- Open Access
- 4 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 431
A New Sensing Platform Based in CNF-TiO2NPs-Wax on Polyimide Substrate for Celiac Disease Diagnostic
Celiac disease (CD), a human leukocyte antigen-associated disorder, is caused by gluten sensitivity and is characterized by mucosal alterations in the small intestine. Currently, its diagnosis involves the determination of serological markers. The traditional method for clinically determining these markers is the enzyme-linked immunosorbent assay. However, immunosensors offer sensitivity and facilitate the development of miniaturized and portable analytical systems. This work focuses on developing an amperometric immunosensor for the quantification of IgA antibodies against tissue transglutaminase (IgA anti-TGA) in human serum samples, providing information on a critical biomarker for CD diagnosis. The electrochemical device was designed on a polyimide substrate using a novel solid ink of wax and carbon nanofibers (CNFs). The working electrode microzone was defined by incorporating aminofunctionalized TiO2 nanoparticles (TiO2NPs). The interactions and morphology of CNFs/wax and TiO2NPs/CNFs/wax electrodes were assessed through different characterization techniques. Furthermore, the device was electrochemically characterized, demonstrating that the incorporation of CNFs into the wax matrix significantly enhanced its conductivity and increased the active surface area of the electrode, while TiO2NPs contributed to the immunoreaction area. The developed device exhibited remarkable sensitivity, selectivity, and reproducibility. These results indicate that the fabricated device is a robust and reliable tool for the precise serological diagnosis of CD.
- 4 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 431
Open AccessA New Sensing Platform Based in CNF-TiO2NPs-Wax on Polyimide Substrate for Celiac Disease Diagnostic
Celiac disease (CD), a human leukocyte antigen-associated disorder, is caused by gluten sensitivity and is characterized by mucosal alterations in the small intestine. Currently, its diagnosis involves the determination of serological markers. The traditional method for clinically determining these markers is the enzyme-linked immunosorbent assay. However, immunosensors offer sensitivity and facilitate the development of miniaturized and portable analytical systems. This work focuses on developing an amperometric immunosensor for the quantification of IgA antibodies against tissue transglutaminase (IgA anti-TGA) in human serum samples, providing information on a critical biomarker for CD diagnosis. The electrochemical device was designed on a polyimide substrate using a novel solid ink of wax and carbon nanofibers (CNFs). The working electrode microzone was defined by incorporating aminofunctionalized TiO2 nanoparticles (TiO2NPs). The interactions and morphology of CNFs/wax and TiO2NPs/CNFs/wax electrodes were assessed through different characterization techniques. Furthermore, the device was electrochemically characterized, demonstrating that the incorporation of CNFs into the wax matrix significantly enhanced its conductivity and increased the active surface area of the electrode, while TiO2NPs contributed to the immunoreaction area. The developed device exhibited remarkable sensitivity, selectivity, and reproducibility. These results indicate that the fabricated device is a robust and reliable tool for the precise serological diagnosis of CD.
- Open Access
- 5 January 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (1) , 10
Origami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection
Nowadays, mycotoxin contamination in cereals and wastewater exposes a safety hazard to consumer health. This work describes the design of a simple, low-cost, and sensitive origami microfluidic paper-based device using electrochemical detection for zearalenone determination. The microfluidic immunosensor was designed on a paper platform by a wax printing process. The graphitized carbon working electrode modified with carbon nanohorns-decorated nanoporous gold showed a higher surface area, sensitivity, and adequate analytical performance. Electrodes were characterized by scanning electron microscopy, energy-dispersive spectroscopy, and cyclic voltammetry. The determination of zearalenone was carried out through a competitive immunoassay using specific antibodies immobilized by a covalent bond on the electrode surface. In the presence of HRP-labeled enzyme conjugate, substrate, and catechol, zearalenone was detected employing the developed immunosensor by applying −0.1 V to the working electrode vs silver as a pseudo-reference electrode. A calibration curve with a linear range between 10 and 1000 µg Kg−1 (R2 = 0.998) was obtained, and the limit of detection and quantification for the electrochemical immunosensor were 4.40 and 14.90 µg Kg−1, respectively. The coefficient of variation for intra- and inter-day assays was less than 5%. The selectivity and specificity of the sensor were evaluated, comparing the response against zearalenone metabolites and other mycotoxins that could affect the corn samples. Therefore, origami is a promising approach for paper-based electrochemical microfluidic sensors coupled to smartphones as a rapid and portable tool for in situ mycotoxins detection in real samples.
- 5 January 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (1) , 10
Open AccessOrigami Paper-Based Electrochemical Immunosensor with Carbon Nanohorns-Decorated Nanoporous Gold for Zearalenone Detection
Nowadays, mycotoxin contamination in cereals and wastewater exposes a safety hazard to consumer health. This work describes the design of a simple, low-cost, and sensitive origami microfluidic paper-based device using electrochemical detection for zearalenone determination. The microfluidic immunosensor was designed on a paper platform by a wax printing process. The graphitized carbon working electrode modified with carbon nanohorns-decorated nanoporous gold showed a higher surface area, sensitivity, and adequate analytical performance. Electrodes were characterized by scanning electron microscopy, energy-dispersive spectroscopy, and cyclic voltammetry. The determination of zearalenone was carried out through a competitive immunoassay using specific antibodies immobilized by a covalent bond on the electrode surface. In the presence of HRP-labeled enzyme conjugate, substrate, and catechol, zearalenone was detected employing the developed immunosensor by applying −0.1 V to the working electrode vs silver as a pseudo-reference electrode. A calibration curve with a linear range between 10 and 1000 µg Kg−1 (R2 = 0.998) was obtained, and the limit of detection and quantification for the electrochemical immunosensor were 4.40 and 14.90 µg Kg−1, respectively. The coefficient of variation for intra- and inter-day assays was less than 5%. The selectivity and specificity of the sensor were evaluated, comparing the response against zearalenone metabolites and other mycotoxins that could affect the corn samples. Therefore, origami is a promising approach for paper-based electrochemical microfluidic sensors coupled to smartphones as a rapid and portable tool for in situ mycotoxins detection in real samples.
- 20 February 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (12) , 1624-1630
A nanostructured paper-based device for phenylalanine neonatal screening by LED-induced fluorescence
In this work, a novel paper-based analytical device (PAD) coupled to LED-induced fluorescence (LIF) detection (fPAD) for the rapid, selective, and sensitive quantification of phenylalanine (Phe) in neonatal samples was developed. The enzymes phenylalanine dehydrogenase (PheDH) and diaphorase were immobilized on a paper microzone previously modified with zinc oxide nanoparticles (ZnONPs) coated with chitosan (CH-ZnONPs). Phe was extracted from the blood spots collected from samples on a filter paper and was mixed with nicotinamide adenine dinucleotide (NAD+) and resazurin. Then the mixture was deposited on the reaction microzone of the fPAD where PheDH converts Phe and NAD+ to phenylpyruvate and NADH, respectively. Finally, NADH was oxidized by diaphorase with the consequent reduction of resazurin to resorufin. The latter was detected by LIF using an excitation wavelength of 535 nm and an emission wavelength of 580 nm using a synchronized video microscope. We compared the responses of the PADs with and without nanomaterials to demonstrate the improved analytical performance of the developed devices. For this, the PADs were modified with the same concentration of horseradish peroxidase (HRP). The fluorescent signal obtained from the PADs with nanomaterials was higher than that of the unmodified PADs. Our method exhibited within- and between-assay variation coefficients below 5.23% and 6.67%, respectively. The detection limit obtained by the developed device was 0.125 μM. The proposed fPAD allowed the simple, rapid, low-cost, and sensitive detection of Phe in neonatal blood samples.
- 20 February 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (12) , 1624-1630
A nanostructured paper-based device for phenylalanine neonatal screening by LED-induced fluorescence
In this work, a novel paper-based analytical device (PAD) coupled to LED-induced fluorescence (LIF) detection (fPAD) for the rapid, selective, and sensitive quantification of phenylalanine (Phe) in neonatal samples was developed. The enzymes phenylalanine dehydrogenase (PheDH) and diaphorase were immobilized on a paper microzone previously modified with zinc oxide nanoparticles (ZnONPs) coated with chitosan (CH-ZnONPs). Phe was extracted from the blood spots collected from samples on a filter paper and was mixed with nicotinamide adenine dinucleotide (NAD+) and resazurin. Then the mixture was deposited on the reaction microzone of the fPAD where PheDH converts Phe and NAD+ to phenylpyruvate and NADH, respectively. Finally, NADH was oxidized by diaphorase with the consequent reduction of resazurin to resorufin. The latter was detected by LIF using an excitation wavelength of 535 nm and an emission wavelength of 580 nm using a synchronized video microscope. We compared the responses of the PADs with and without nanomaterials to demonstrate the improved analytical performance of the developed devices. For this, the PADs were modified with the same concentration of horseradish peroxidase (HRP). The fluorescent signal obtained from the PADs with nanomaterials was higher than that of the unmodified PADs. Our method exhibited within- and between-assay variation coefficients below 5.23% and 6.67%, respectively. The detection limit obtained by the developed device was 0.125 μM. The proposed fPAD allowed the simple, rapid, low-cost, and sensitive detection of Phe in neonatal blood samples.
- Open Access
- 1 September 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 232, 765-772
An ordered mesoporous carbon modified electrochemical sensor for solid-phase microextraction and determination of triclosan in environmental samples
- 1 September 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 232, 765-772
Open AccessAn ordered mesoporous carbon modified electrochemical sensor for solid-phase microextraction and determination of triclosan in environmental samples
- Open Access
- 1 September 2016
- Published by Elsevier in Microchemical Journal
- Vol. 128, 18-25
Nanostructured platform integrated into a microfluidic immunosensor coupled to laser-induced fluorescence for the epithelial cancer biomarker determination
- 1 September 2016
- Published by Elsevier in Microchemical Journal
- Vol. 128, 18-25
Open AccessNanostructured platform integrated into a microfluidic immunosensor coupled to laser-induced fluorescence for the epithelial cancer biomarker determination
- 27 January 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (3) , 1203-1210
An electrochemical immunosensor for anti-T. cruzi IgM antibodies, a biomarker for congenital Chagas disease, using a screen-printed electrode modified with gold nanoparticles and functionalized with shed acute phase antigen
- 27 January 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (3) , 1203-1210
An electrochemical immunosensor for anti-T. cruzi IgM antibodies, a biomarker for congenital Chagas disease, using a screen-printed electrode modified with gold nanoparticles and functionalized with shed acute phase antigen
- 11 September 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (3-4) , 531-538
Electrochemical immunosensing using a nanostructured functional platform for determination of α-zearalanol
- 11 September 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (3-4) , 531-538
Electrochemical immunosensing using a nanostructured functional platform for determination of α-zearalanol
- 27 June 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (18) , 4702-4709
Food safety control of zeranol through voltammetric immunosensing on Au–Pt bimetallic nanoparticle surfaces
This study reports an accurate and sensitive strategy for zeranol (ZER) determination in bovine urine samples. ZER is a mycotoxin widely used as a synthetic growth promoter in the livestock production whose residues could present a potential risk for human health. Therefore, its use as an animal feed additive has been banned in most countries. ZER determination was accomplished using an electrochemical system in which bimetallic Au–Pt nanoparticles (Au–PtNPs) were electro-synthesized on a screen-printed carbon electrode (SPCE). The obtained Au–PtNP platform was immunofunctionalized using specific anti-ZER antibodies as a strategy to avoid potential interference. After biorecognition, ZER was directly oxidized and detected by square-wave voltammetry (SWV). The Au–PtNP surface was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and cyclic voltammetry (CV). The limit of detection calculated was 0.01 ng mL−1 with a wide linear range from 0.03 to 30 ng mL−1. This method promises to be suitable for ZER quantification in bovine urine samples ensuring food quality and safety, as well as consumer’s health.
- 27 June 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (18) , 4702-4709
Food safety control of zeranol through voltammetric immunosensing on Au–Pt bimetallic nanoparticle surfaces
This study reports an accurate and sensitive strategy for zeranol (ZER) determination in bovine urine samples. ZER is a mycotoxin widely used as a synthetic growth promoter in the livestock production whose residues could present a potential risk for human health. Therefore, its use as an animal feed additive has been banned in most countries. ZER determination was accomplished using an electrochemical system in which bimetallic Au–Pt nanoparticles (Au–PtNPs) were electro-synthesized on a screen-printed carbon electrode (SPCE). The obtained Au–PtNP platform was immunofunctionalized using specific anti-ZER antibodies as a strategy to avoid potential interference. After biorecognition, ZER was directly oxidized and detected by square-wave voltammetry (SWV). The Au–PtNP surface was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and cyclic voltammetry (CV). The limit of detection calculated was 0.01 ng mL−1 with a wide linear range from 0.03 to 30 ng mL−1. This method promises to be suitable for ZER quantification in bovine urine samples ensuring food quality and safety, as well as consumer’s health.