Huan Ming Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Huan Ming Xia has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Peng Zhu
School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
7 shared publications Ruiqi Shen
School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
7 shared publications- Jun Zhang
Queensland Quantum and Advanced Technologies Research Institute Griffith University Nathan Queensland Australia
5 shared publications Z. P. Wang
Singapore Institute of Manufacturing Technology 3 , 73 Nanyang Drive, Singapore 637662, Singapore
5 shared publications- C. Shu
National University of Singapore
4 shared publications Y. Y. Zhang
School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, People’s Republic of China
4 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9540508
A Precise Microdispenser With Closed-Loop Control via Capacitive Volume Sensing
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9540508
A Precise Microdispenser With Closed-Loop Control via Capacitive Volume Sensing
- 16 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (3) , 4703-4710
Automatic Measurement and Delivery of Micro-Quantity Liquids Using a Miniaturized Capacitive Volume Sensor
Microfluidics has been proved to be an efficient tool in various biochemical and medical applications, greatly promoting the miniaturization and automation of new analytical instruments. One important issue involved is precise handling of micro-quantity liquids. In this work, a system is designed for automatic measurement and transport of small-volume liquids using a miniaturized capacitive sensor and pneumatic pumping. Two devices with different volume ranges are tested with DI water, PBS buffer, glycerol-water mixture, and ethanol, respectively. For the 2 μL-range design, close results are obtained for DI water, PBS buffer and glycerol-water mixture, the maximum error Emax is around 0.016 μL (0.80%FS). For ethanol which is volatile and has a lower dielectric constant, Emax is 0.032 μL (1.6%FS). For the 20 μL-range design, Emax is 0.045 μL (0.23%FS) and 0.080 μL (0.40%FS), respectively. The potential application of the system is also demonstrated through a complexometric micro titration experiment. Using a titration volume around 60 μL, the Ca2+ concentration in a solution in the range of 1 mmol/L -10 mmol/L can be determined, with a mean absolute relative error (MARE) of 2.5%.
- 16 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (3) , 4703-4710
Automatic Measurement and Delivery of Micro-Quantity Liquids Using a Miniaturized Capacitive Volume Sensor
Microfluidics has been proved to be an efficient tool in various biochemical and medical applications, greatly promoting the miniaturization and automation of new analytical instruments. One important issue involved is precise handling of micro-quantity liquids. In this work, a system is designed for automatic measurement and transport of small-volume liquids using a miniaturized capacitive sensor and pneumatic pumping. Two devices with different volume ranges are tested with DI water, PBS buffer, glycerol-water mixture, and ethanol, respectively. For the 2 μL-range design, close results are obtained for DI water, PBS buffer and glycerol-water mixture, the maximum error Emax is around 0.016 μL (0.80%FS). For ethanol which is volatile and has a lower dielectric constant, Emax is 0.032 μL (1.6%FS). For the 20 μL-range design, Emax is 0.045 μL (0.23%FS) and 0.080 μL (0.40%FS), respectively. The potential application of the system is also demonstrated through a complexometric micro titration experiment. Using a titration volume around 60 μL, the Ca2+ concentration in a solution in the range of 1 mmol/L -10 mmol/L can be determined, with a mean absolute relative error (MARE) of 2.5%.
- 11 February 2025
- Published by Springer Nature in Journal of Plant Diseases and Protection
- Vol. 132 (2) , 1-8
A portable microfluidic system for Bursaphelenchus xylophilus detection
- 11 February 2025
- Published by Springer Nature in Journal of Plant Diseases and Protection
- Vol. 132 (2) , 1-8
A portable microfluidic system for Bursaphelenchus xylophilus detection
- 29 January 2024
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 63 (5) , 2432-2440
Droplet Ejection by Pulsatile Airflow
- 29 January 2024
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 63 (5) , 2432-2440
Droplet Ejection by Pulsatile Airflow
- 3 January 2024
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 63 (2) , 1066-1079
Construction of Ultra-Mixed Energetic Composite Systems by Micro Continuous Flow Coupled with Spray Drying Technology
- 3 January 2024
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 63 (2) , 1066-1079
Construction of Ultra-Mixed Energetic Composite Systems by Micro Continuous Flow Coupled with Spray Drying Technology
- 21 July 2023
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (8) , 1-9
An investigation on microfluidic preparation of aluminum phosphate adjuvant
- 21 July 2023
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (8) , 1-9
An investigation on microfluidic preparation of aluminum phosphate adjuvant
- 23 January 2023
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 62 (4) , 1997-2007
Regulating the Gas–Liquid Slug Flow in Microchannels through High-Frequency Pulsatile Perturbations
- 23 January 2023
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 62 (4) , 1997-2007
Regulating the Gas–Liquid Slug Flow in Microchannels through High-Frequency Pulsatile Perturbations
- 28 November 2022
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 61 (48) , 17593-17606
Coupling Oscillating–Swirling–Coflowing: A Microfluidic Strategy for Superior Safety and Output Performance of Core–Shell Energetic Microspheres
- 28 November 2022
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 61 (48) , 17593-17606
Coupling Oscillating–Swirling–Coflowing: A Microfluidic Strategy for Superior Safety and Output Performance of Core–Shell Energetic Microspheres
- 4 October 2021
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 25 (11) , 1-11
A facile method for microfluidic metering and transport
- 4 October 2021
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 25 (11) , 1-11
A facile method for microfluidic metering and transport
- Open Access
- 19 May 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (5) , 160
Design and Fabrication of the Vertical-Flow Bioreactor for Compaction Hepatocyte Culture in Drug Testing Application
The perfusion culture of primary hepatocytes has been widely adopted to build bioreactors for various applications. As a drug testing platform, a unique vertical-flow bioreactor (VfB) array was found to create the compaction culture of hepatocytes which mimicked the mechanic microenvironment in vivo while maintaining the 3D cell morphology in a 2D culture setup and enhancing the hepatic functions for a sustained culture. Here, we report the methodology in designing and fabricating the VfB to reach ideal bioreactor requirements, optimizing the VfB as a prototype for drug testing, and to demonstrate the enhanced hepatic function so as to demonstrate the performance of the bioreactor. This device enables the modular, scalable, and manufacturable construction of a functional drug testing platform through the sustained maintenance of model cells.
- 19 May 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (5) , 160
Open AccessDesign and Fabrication of the Vertical-Flow Bioreactor for Compaction Hepatocyte Culture in Drug Testing Application
The perfusion culture of primary hepatocytes has been widely adopted to build bioreactors for various applications. As a drug testing platform, a unique vertical-flow bioreactor (VfB) array was found to create the compaction culture of hepatocytes which mimicked the mechanic microenvironment in vivo while maintaining the 3D cell morphology in a 2D culture setup and enhancing the hepatic functions for a sustained culture. Here, we report the methodology in designing and fabricating the VfB to reach ideal bioreactor requirements, optimizing the VfB as a prototype for drug testing, and to demonstrate the enhanced hepatic function so as to demonstrate the performance of the bioreactor. This device enables the modular, scalable, and manufacturable construction of a functional drug testing platform through the sustained maintenance of model cells.