John Chauvin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John Chauvin has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Fartash Vasefi
SafetySpect Inc., Grand Forks, ND 58202, USA
3 shared publications - Alireza Akhbardeh
CereVu Medical, San Francisco, CA, US.
2 shared publications - Kouhyar Tavakolian
University of North Dakota, Grand Forks, United States
2 shared publications - Nicholas MacKinnon
SafetySpect Inc., Grand Forks, ND 58202, USA
2 shared publications - Ray Duran
School of Electrical Engineering and Computer Science, University of North Dakota, Grand Forks, ND 58202, USA
2 shared publications Alireza Akhbardeh
1 shared publication
Latest Publications
- Open Access
- 25 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8490
Simulated Annealing-Based Wavelength Selection for Robust Tissue Oxygenation Estimation Powered by the Extended Modified Lambert–Beer Law
In this paper, we present a set of algorithms to enable the development of inexpensive hyperspectral sensors capable of estimating tissue oxygenation for wound monitoring. Estimation is conducted using the extended modified Lambert–Beer law, which has previously been proven robust to differences in melanin concentration. We introduce a novel wavelength selection algorithm that enables the estimation to be performed with high accuracy using only a small number (5–10) of wavelengths. Validation performed with Monte Carlo simulation data resulted in prediction errors <1%, with no significant differences among various skin types, for as few as five wavelengths under conditions representing both high precision instrumentation and more cost-effective sensors designed with inexpensive LEDs and/or filters. Validation with in vivo data collected from an occlusion study with 13 Asian volunteers showed statistically significant separation between the estimates for the at-rest and arterial occlusion states. Additional stability testing proved the proposed algorithms to be robust to small changes in the selected wavelengths as may occur in a real LED due to manufacturing tolerances and temperature fluctuations. This work concluded that the development of an inexpensive hyperspectral device for wound monitoring in all skin types is feasible using just a small number of wavelengths.
- 25 August 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8490
Open AccessSimulated Annealing-Based Wavelength Selection for Robust Tissue Oxygenation Estimation Powered by the Extended Modified Lambert–Beer Law
In this paper, we present a set of algorithms to enable the development of inexpensive hyperspectral sensors capable of estimating tissue oxygenation for wound monitoring. Estimation is conducted using the extended modified Lambert–Beer law, which has previously been proven robust to differences in melanin concentration. We introduce a novel wavelength selection algorithm that enables the estimation to be performed with high accuracy using only a small number (5–10) of wavelengths. Validation performed with Monte Carlo simulation data resulted in prediction errors <1%, with no significant differences among various skin types, for as few as five wavelengths under conditions representing both high precision instrumentation and more cost-effective sensors designed with inexpensive LEDs and/or filters. Validation with in vivo data collected from an occlusion study with 13 Asian volunteers showed statistically significant separation between the estimates for the at-rest and arterial occlusion states. Additional stability testing proved the proposed algorithms to be robust to small changes in the selected wavelengths as may occur in a real LED due to manufacturing tolerances and temperature fluctuations. This work concluded that the development of an inexpensive hyperspectral device for wound monitoring in all skin types is feasible using just a small number of wavelengths.
- Open Access
- 11 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10628
Simulated Annealing-Based Hyperspectral Data Optimization for Fish Species Classification: Can the Number of Measured Wavelengths Be Reduced?
Relative to standard red/green/blue (RGB) imaging systems, hyperspectral imaging systems offer superior capabilities but tend to be expensive and complex, requiring either a mechanically complex push-broom line scanning method, a tunable filter, or a large set of light emitting diodes (LEDs) to collect images in multiple wavelengths. This paper proposes a new methodology to support the design of a hypothesized system that uses three imaging modes—fluorescence, visible/near-infrared (VNIR) reflectance, and shortwave infrared (SWIR) reflectance—to capture narrow-band spectral data at only three to seven narrow wavelengths. Simulated annealing is applied to identify the optimal wavelengths for sparse spectral measurement with a cost function based on the accuracy provided by a weighted k-nearest neighbors (WKNN) classifier, a common and relatively robust machine learning classifier. Two separate classification approaches are presented, the first using a multi-layer perceptron (MLP) artificial neural network trained on sparse data from the three individual spectra and the second using a fusion of the data from all three spectra. The results are compared with those from four alternative classifiers based on common machine learning algorithms. To validate the proposed methodology, reflectance and fluorescence spectra in these three spectroscopic modes were collected from fish fillets and used to classify the fillets by species. Accuracies determined from the two classification approaches are compared with benchmark values derived by training the classifiers with the full resolution spectral data. The results of the single-layer classification study show accuracies ranging from ~68% for SWIR reflectance to ~90% for fluorescence with just seven wavelengths. The results of the fusion classification study show accuracies of about 95% with seven wavelengths and more than 90% even with just three wavelengths. Reducing the number of required wavelengths facilitates the creation of rapid and cost-effective spectral imaging systems that can be used for widespread analysis in food monitoring/food fraud, agricultural, and biomedical applications.
- 11 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10628
Open AccessSimulated Annealing-Based Hyperspectral Data Optimization for Fish Species Classification: Can the Number of Measured Wavelengths Be Reduced?
Relative to standard red/green/blue (RGB) imaging systems, hyperspectral imaging systems offer superior capabilities but tend to be expensive and complex, requiring either a mechanically complex push-broom line scanning method, a tunable filter, or a large set of light emitting diodes (LEDs) to collect images in multiple wavelengths. This paper proposes a new methodology to support the design of a hypothesized system that uses three imaging modes—fluorescence, visible/near-infrared (VNIR) reflectance, and shortwave infrared (SWIR) reflectance—to capture narrow-band spectral data at only three to seven narrow wavelengths. Simulated annealing is applied to identify the optimal wavelengths for sparse spectral measurement with a cost function based on the accuracy provided by a weighted k-nearest neighbors (WKNN) classifier, a common and relatively robust machine learning classifier. Two separate classification approaches are presented, the first using a multi-layer perceptron (MLP) artificial neural network trained on sparse data from the three individual spectra and the second using a fusion of the data from all three spectra. The results are compared with those from four alternative classifiers based on common machine learning algorithms. To validate the proposed methodology, reflectance and fluorescence spectra in these three spectroscopic modes were collected from fish fillets and used to classify the fillets by species. Accuracies determined from the two classification approaches are compared with benchmark values derived by training the classifiers with the full resolution spectral data. The results of the single-layer classification study show accuracies ranging from ~68% for SWIR reflectance to ~90% for fluorescence with just seven wavelengths. The results of the fusion classification study show accuracies of about 95% with seven wavelengths and more than 90% even with just three wavelengths. Reducing the number of required wavelengths facilitates the creation of rapid and cost-effective spectral imaging systems that can be used for widespread analysis in food monitoring/food fraud, agricultural, and biomedical applications.
- Open Access
- 29 June 2021
- Published by IntechOpen
Advanced Optical Technologies in Food Quality and Waste Management
Food waste is a global problem caused in large part by premature food spoilage. Seafood is especially prone to food waste because it spoils easily. Of the annual 4.7 billion pounds of seafood destined for U.S. markets between 2009 and 2013, 40 to 47 percent ended up as waste. This problem is due in large part to a lack of available technologies to enable rapid, accurate, and reliable valorization of food products from boat or farm to table. Fortunately, recent advancements in spectral sensing technologies and spectroscopic analyses show promise for addressing this problem. Not only could these advancements help to solve hunger issues in impoverished regions of the globe, but they could also benefit the average consumer by enabling intelligent pricing of food products based on projected shelf life. Additional technologies that enforce trust and compliance (e.g., blockchain) could further serve to prevent food fraud by maintaining records of spoilage conditions and other quality validation at all points along the food supply chain and provide improved transparency as regards contract performance and attribution of liability. In this chapter we discuss technologies that have enabled the development of hand-held spectroscopic devices for detecting food spoilage. We also discuss some of the analytical methods used to classify and quantify spoilage based on spectral measurements.
- 29 June 2021
- Published by IntechOpen
Open AccessAdvanced Optical Technologies in Food Quality and Waste Management
Food waste is a global problem caused in large part by premature food spoilage. Seafood is especially prone to food waste because it spoils easily. Of the annual 4.7 billion pounds of seafood destined for U.S. markets between 2009 and 2013, 40 to 47 percent ended up as waste. This problem is due in large part to a lack of available technologies to enable rapid, accurate, and reliable valorization of food products from boat or farm to table. Fortunately, recent advancements in spectral sensing technologies and spectroscopic analyses show promise for addressing this problem. Not only could these advancements help to solve hunger issues in impoverished regions of the globe, but they could also benefit the average consumer by enabling intelligent pricing of food products based on projected shelf life. Additional technologies that enforce trust and compliance (e.g., blockchain) could further serve to prevent food fraud by maintaining records of spoilage conditions and other quality validation at all points along the food supply chain and provide improved transparency as regards contract performance and attribution of liability. In this chapter we discuss technologies that have enabled the development of hand-held spectroscopic devices for detecting food spoilage. We also discuss some of the analytical methods used to classify and quantify spoilage based on spectral measurements.