Srinivasan Vadivel
Srinivasan Vadivel has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Julfikar Haider
Department of Engineering Manchester Metropolitan University Manchester UK
3 shared publications - Sridhar Ramasamy
Department of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, India
3 shared publications - Boopathi Chettiagounder Sengodan
Department of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Kattankulathur 603203, India
2 shared publications - Eduardo Manuel Godinho Rodrigues
INESC-ID, Sustainable Power Systems Group, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal
2 shared publications - Mominul Ahsan
Department of Computer Science, University of York, York YO10 5GH, UK
2 shared publications - Minarul Islam
Department of Electrical and Electronic Engineering University of Dhaka Dhaka Bangladesh
1 shared publication
Latest Publications
- Open Access
- 22 September 2023
- Published by Wiley in International Journal of Energy Research
- Vol. 2023, 1-18
Hybrid Social Grouping Algorithm-Perturb and Observe Power Tracking Scheme for Partially Shaded Photovoltaic Array
This research work emphasizes proposing a hybrid social grouping algorithm (SGA) and perturb and observe (P&O) scheme for tracking the global power peak in a partially shaded photovoltaic (PV) array. PV panels getting shaded, even partially, exhibits multiple power peaks, and hence conventional maximum power point tracking (MPPT) algorithms fail in tracking the maximum power peak as it gets deceived by local maxima. Most of the prevailing global search algorithms suffer in performance due to the stochastic search which consumes time even after nearing the global power peak. Therefore, a hybridization of the global search algorithm and the conventional algorithm will be a prudent solution. SGA, a global search algorithm based on individual and group cognizant behaviour, has been hybridized with a well-entrenched P&O algorithm that complements each other in achieving the global power peak swiftly. The hybridized algorithm achieves the global power peak in 0.4 seconds faster than the stand-alone SGA algorithm during complex shading conditions. The proposed scheme has been implemented for an 800 W PV array in a MATLAB simulation and validated experimentally in a hardware setup using a SAS1000L solar array simulator-programmable source, a DC-DC converter, and a dSPACE 1104 controller. The simulation and experimental results reveal that the proposed search scheme is very competent in converging towards the global maximum through SGA first and achieving the peak point through P&O. The proposed scheme has also been tested for a dynamic shading pattern, and it is evident that the proposed scheme outperforms its counterparts in terms of convergence time.
- 22 September 2023
- Published by Wiley in International Journal of Energy Research
- Vol. 2023, 1-18
Open AccessHybrid Social Grouping Algorithm-Perturb and Observe Power Tracking Scheme for Partially Shaded Photovoltaic Array
This research work emphasizes proposing a hybrid social grouping algorithm (SGA) and perturb and observe (P&O) scheme for tracking the global power peak in a partially shaded photovoltaic (PV) array. PV panels getting shaded, even partially, exhibits multiple power peaks, and hence conventional maximum power point tracking (MPPT) algorithms fail in tracking the maximum power peak as it gets deceived by local maxima. Most of the prevailing global search algorithms suffer in performance due to the stochastic search which consumes time even after nearing the global power peak. Therefore, a hybridization of the global search algorithm and the conventional algorithm will be a prudent solution. SGA, a global search algorithm based on individual and group cognizant behaviour, has been hybridized with a well-entrenched P&O algorithm that complements each other in achieving the global power peak swiftly. The hybridized algorithm achieves the global power peak in 0.4 seconds faster than the stand-alone SGA algorithm during complex shading conditions. The proposed scheme has been implemented for an 800 W PV array in a MATLAB simulation and validated experimentally in a hardware setup using a SAS1000L solar array simulator-programmable source, a DC-DC converter, and a dSPACE 1104 controller. The simulation and experimental results reveal that the proposed search scheme is very competent in converging towards the global maximum through SGA first and achieving the peak point through P&O. The proposed scheme has also been tested for a dynamic shading pattern, and it is evident that the proposed scheme outperforms its counterparts in terms of convergence time.
- Open Access
Social Grouping Algorithm Aided Maximum Power Point Tracking Scheme for Partial Shaded Photovoltaic Array
Photovoltaic (PV) systems-based energy generation is relatively easy to install, even at a large scale, because it is scalable in size and is thus easy to transport. Harnessing maximum power is only possible if maximum power tracking (MPPT) functionality is available as part of the power converter control that interfaces the PV panels to the grid. Solar exposure covering all PV panels is unlikely to happen all the time, which is known as a partial shading (PS) phenomenon. As a result, depending on the MPPT algorithm adopted, it may fail to find a maximum global power peak, being locked into a local power peak. This research work discusses an alternative MPPT control technique inspired in the social group optimization (SGO) algorithm. SGO belongs to the meta-heuristic optimization techniques family. In this sense, the SGO method ability for solving global optimization problems is explored to find the global maximum power point (GMPP) under the presence of local MPPs. The introduced SGO–MPPT was subjected to different PS conditions and complex shading patterns. Then, its performance was compared to other global search MPPT techniques, which include particle swarm optimization (PSO), the dragon fly algorithm (DFO) and the artificial bee colony algorithm (ABC). The simulation outcomes for the SGO–MPPT characterization showed good results, namely rapid global power tracking in less than 0.2 s with reduced oscillation; the efficiency of solar energy harness was slightly above 99%.
Open AccessSocial Grouping Algorithm Aided Maximum Power Point Tracking Scheme for Partial Shaded Photovoltaic Array
Photovoltaic (PV) systems-based energy generation is relatively easy to install, even at a large scale, because it is scalable in size and is thus easy to transport. Harnessing maximum power is only possible if maximum power tracking (MPPT) functionality is available as part of the power converter control that interfaces the PV panels to the grid. Solar exposure covering all PV panels is unlikely to happen all the time, which is known as a partial shading (PS) phenomenon. As a result, depending on the MPPT algorithm adopted, it may fail to find a maximum global power peak, being locked into a local power peak. This research work discusses an alternative MPPT control technique inspired in the social group optimization (SGO) algorithm. SGO belongs to the meta-heuristic optimization techniques family. In this sense, the SGO method ability for solving global optimization problems is explored to find the global maximum power point (GMPP) under the presence of local MPPs. The introduced SGO–MPPT was subjected to different PS conditions and complex shading patterns. Then, its performance was compared to other global search MPPT techniques, which include particle swarm optimization (PSO), the dragon fly algorithm (DFO) and the artificial bee colony algorithm (ABC). The simulation outcomes for the SGO–MPPT characterization showed good results, namely rapid global power tracking in less than 0.2 s with reduced oscillation; the efficiency of solar energy harness was slightly above 99%.
- Open Access
Performance Enhancement of a Partially Shaded Photovoltaic Array by Optimal Reconfiguration and Current Injection Schemes
The output of a photovoltaic array is reduced considerably when PV panels are shaded even partially. The impact of shading causes an appreciable loss in power delivery, since the PV panels are connected in series and parallel to contribute to the required voltage and power for the load. The prevailing research on mitigating the shading impact is mostly based on complex reconfiguration strategies where the PV panels are subjected to complex rewiring schemes. On the other hand, to disperse the shading many studies in the literature defend the physical rearrangement of the panels. The available intensive reconfiguration schemes, such as the series parallel (SP), bridge link (BL), honeycomb (HC), and total cross tied (TCT) schemes, try only to mitigate the shading impact and there is no scope for compensation; as a result, a loss of output power is inevitable. In the proposed research work, both the mitigation of and the compensation for the losses incurred due to shading are studied. In this work, an optimal reconfiguration scheme is adopted to reduce the shading impact and a power electronic circuit with a battery source is designed to compensate for the shading losses in all aspects. In the optimal reconfiguration scheme, a bifurcation strategy is adopted in each column and the electrical connections of the PV panels are interchanged such that the shading impact is dispersed. The power electronic circuit consists of a half-bridge buck converter with a battery source that injects the current required by a shaded column. This setup compensates for the shaded PV array’s power and improves the efficiency of the total system. The proposed scheme was implemented in a 3200 W system and subjected to various shading patterns, including single panel shading, corner shading, long and wide shading, and random shading. The proposed scheme was simulated in the MATLAB Simulink environment and compared with static 4 × 4 PV array configurations, including the series parallel (SP), bridge link (BL), honeycomb (HC), and total cross tied (TCT) configurations. The comparative performance was assessed in terms of mismatch power loss, fill factor, and efficiency. The proposed system is suitable for all shading patterns and was proved to be very efficient even in the worst shading, where 1353 W was saved.
Open AccessPerformance Enhancement of a Partially Shaded Photovoltaic Array by Optimal Reconfiguration and Current Injection Schemes
The output of a photovoltaic array is reduced considerably when PV panels are shaded even partially. The impact of shading causes an appreciable loss in power delivery, since the PV panels are connected in series and parallel to contribute to the required voltage and power for the load. The prevailing research on mitigating the shading impact is mostly based on complex reconfiguration strategies where the PV panels are subjected to complex rewiring schemes. On the other hand, to disperse the shading many studies in the literature defend the physical rearrangement of the panels. The available intensive reconfiguration schemes, such as the series parallel (SP), bridge link (BL), honeycomb (HC), and total cross tied (TCT) schemes, try only to mitigate the shading impact and there is no scope for compensation; as a result, a loss of output power is inevitable. In the proposed research work, both the mitigation of and the compensation for the losses incurred due to shading are studied. In this work, an optimal reconfiguration scheme is adopted to reduce the shading impact and a power electronic circuit with a battery source is designed to compensate for the shading losses in all aspects. In the optimal reconfiguration scheme, a bifurcation strategy is adopted in each column and the electrical connections of the PV panels are interchanged such that the shading impact is dispersed. The power electronic circuit consists of a half-bridge buck converter with a battery source that injects the current required by a shaded column. This setup compensates for the shaded PV array’s power and improves the efficiency of the total system. The proposed scheme was implemented in a 3200 W system and subjected to various shading patterns, including single panel shading, corner shading, long and wide shading, and random shading. The proposed scheme was simulated in the MATLAB Simulink environment and compared with static 4 × 4 PV array configurations, including the series parallel (SP), bridge link (BL), honeycomb (HC), and total cross tied (TCT) configurations. The comparative performance was assessed in terms of mismatch power loss, fill factor, and efficiency. The proposed system is suitable for all shading patterns and was proved to be very efficient even in the worst shading, where 1353 W was saved.