Jianhua Ou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianhua Ou has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jian Xue
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
2 shared publications - Jianguo Wang
Wuhan University
2 shared publications - Lingcong She
School of Electrical Engineering and Automation, Wuhan University, Hubei, China
2 shared publications - Yadong Fan
Wuhan University
2 shared publications Jianguo Wang
School of Electrical Engineering and Automation Wuhan University Wuhan 430072 China
1 shared publicationJianping Wang
School of Electrical Engineering and Automation, Wuhan University, Hubei, China
1 shared publication
Latest Publications
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 387-396
Infrared Image Target Detection of Substation Electrical Equipment Using an Improved Faster R-CNN
Infrared camera can be used to monitor the condition of substation electrical equipment. Fast and accurate target detection algorithm is the key for infrared intelligent on-line routing inspection. However, the performance of traditional detection algorithm is poor due to the complex background of substation. To solve this problem, this paper proposes a target detection model based on the improved faster region-based convolutional neural networks (Faster R-CNN), which can be used for automatic detection of five kinds of electrical equipment in substations. The feature extraction network of this model is improved based on VGG16 by abandoning some high-level convolutions to accelerate the training and testing speed. Meanwhile, the 1:3 and 3:1 aspect ratio of anchor are added to improve the detection accuracy of elongated equipment. Experiments are performed on an infrared image dataset of substation to detect five types of equipment. The robustness tests of our model are carried out, too. The results show that our model performs well in detection accuracy and speed, achieving a mean detected accuracy of 95.32% and running at 11 frame/second. In addition, our model is robust to noise and lightness, which is suitable to other substations. Comparing to other models, our model has the highest mAP@0.5 of 92.78%.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 387-396
Infrared Image Target Detection of Substation Electrical Equipment Using an Improved Faster R-CNN
Infrared camera can be used to monitor the condition of substation electrical equipment. Fast and accurate target detection algorithm is the key for infrared intelligent on-line routing inspection. However, the performance of traditional detection algorithm is poor due to the complex background of substation. To solve this problem, this paper proposes a target detection model based on the improved faster region-based convolutional neural networks (Faster R-CNN), which can be used for automatic detection of five kinds of electrical equipment in substations. The feature extraction network of this model is improved based on VGG16 by abandoning some high-level convolutions to accelerate the training and testing speed. Meanwhile, the 1:3 and 3:1 aspect ratio of anchor are added to improve the detection accuracy of elongated equipment. Experiments are performed on an infrared image dataset of substation to detect five types of equipment. The robustness tests of our model are carried out, too. The results show that our model performs well in detection accuracy and speed, achieving a mean detected accuracy of 95.32% and running at 11 frame/second. In addition, our model is robust to noise and lightness, which is suitable to other substations. Comparing to other models, our model has the highest mAP@0.5 of 92.78%.
- 30 December 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 17 (4) , 583-591
Online Monitoring of Electrical Equipment Condition Based on Infrared Image Temperature Data Visualization
Temperature is one of the most common indicators for the health of electrical equipment in the substation. By now, infrared thermography has been an important monitoring tool due to its real‐time temperature measurement and noncontact manner. However, at present, portable thermal imagers are usually used to collect and store the status image of single equipment at a certain time, which cannot continuously track the condition of the equipment and the efficiency is very low. In order to solve this problem, our team proposed a method for online condition of electrical equipment based on the visualization and processing of infrared image temperature data. We developed video inspection software, equipped with an infrared camera for automatic inspection to obtain infrared images. After that, the target equipment in a whole image are automatically extracted based on the reference image and the equipment type of each target is classified. Then, in order to visualize temperature data and extract temperature information for different types of equipment, the concepts of heating spot, heating section, and heating area are defined. Finally, diagnosis rules based on relevant related thermal fault diagnosis standards and past experience are proposed to evaluate the condition of each target equipment, using the temperature rise and heat generation percentage. The method has been applied in a real substation and proved its effectiveness. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 30 December 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 17 (4) , 583-591
Online Monitoring of Electrical Equipment Condition Based on Infrared Image Temperature Data Visualization
Temperature is one of the most common indicators for the health of electrical equipment in the substation. By now, infrared thermography has been an important monitoring tool due to its real‐time temperature measurement and noncontact manner. However, at present, portable thermal imagers are usually used to collect and store the status image of single equipment at a certain time, which cannot continuously track the condition of the equipment and the efficiency is very low. In order to solve this problem, our team proposed a method for online condition of electrical equipment based on the visualization and processing of infrared image temperature data. We developed video inspection software, equipped with an infrared camera for automatic inspection to obtain infrared images. After that, the target equipment in a whole image are automatically extracted based on the reference image and the equipment type of each target is classified. Then, in order to visualize temperature data and extract temperature information for different types of equipment, the concepts of heating spot, heating section, and heating area are defined. Finally, diagnosis rules based on relevant related thermal fault diagnosis standards and past experience are proposed to evaluate the condition of each target equipment, using the temperature rise and heat generation percentage. The method has been applied in a real substation and proved its effectiveness. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 30 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 2787-2796
Insulator Breakage Detection Utilizing a Convolutional Neural Network Ensemble Implemented With Small Sample Data Augmentation and Transfer Learning
Online fault detection of insulators is a necessary requirement for the development of a smart grid, which directly affects the safety and reliability of power system operations. Breakage is an important factor causing insulator abnormalities, and a large number of image samples are often required for training to complete defect identification with the help of AI deep learning. In this paper, we propose a convolutional neural network ensemble implemented using small samples, data augmentation and transfer learning for insulator breakage detection. We used data augmentation to expand the small sample of 200 insulator images by 15 times to 3000 images, built a VGG16 transfer network, pre-trained the VGG16 network convolutional basis weights, and improved the training performance and efficiency of the model with freeze training and fine-tuning training. The training on 2700 images and testing results on 300 images show that the proposed method can achieve an accuracy of 0.9871 for insulator breakage recognition.
- 30 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 2787-2796
Insulator Breakage Detection Utilizing a Convolutional Neural Network Ensemble Implemented With Small Sample Data Augmentation and Transfer Learning
Online fault detection of insulators is a necessary requirement for the development of a smart grid, which directly affects the safety and reliability of power system operations. Breakage is an important factor causing insulator abnormalities, and a large number of image samples are often required for training to complete defect identification with the help of AI deep learning. In this paper, we propose a convolutional neural network ensemble implemented using small samples, data augmentation and transfer learning for insulator breakage detection. We used data augmentation to expand the small sample of 200 insulator images by 15 times to 3000 images, built a VGG16 transfer network, pre-trained the VGG16 network convolutional basis weights, and improved the training performance and efficiency of the model with freeze training and fine-tuning training. The training on 2700 images and testing results on 300 images show that the proposed method can achieve an accuracy of 0.9871 for insulator breakage recognition.