Rasime Uyguroğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rasime Uyguroğlu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Wael Zeinelabedeen
Department of Electrical and Electronic Engineering, Eastern Mediterranean University, Famagusta 99628, Turkey
2 shared publications A.M.M.A. Allam
German Univ Cairo, Fac Informat & Engn Technol, Cairo, Egypt
1 shared publicationAbdullah Y. Oztoprak
Final International University, Kyrenia, Cyprus
1 shared publicationAbdullah Y. Öztoprak
Electrical and Electronic Engineering Department; Famagusta; Eastern Mediterranean University; Mersin-10 Turkey
1 shared publication- Abdullah Y. Öztoprak
Department of Electrical and Electronic Engineering Cyprus International University, Nicosia 99258, Northern Cyprus
1 shared publication Abdullah Yücel Öztoprak
Final Int Univ, Fac Engn, Dept Elect & Elect Engn, Girne, North Cyprus, Turkey
1 shared publication
Latest Publications
- Open Access
- 11 August 2023
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 38 (3) , 177–183
Scanning of the Near-field Focused Beam by Changing Frequency
A new antenna array system is introduced which enables the movement of a near-field focused beam by change of frequency. The shift in the beam is achieved by using multi-wavelength transmission lines between successive elements of the array. At the designed frequency the beam is focused at the focal point. Due to the differences in the transmission line lengths feeding the antenna elements, a progressive phase change occurs between these elements. These phase differences between the elements cause a shift in the beam position. An 8×8 patch antenna array system was designed at 2.4 GHz on a microstrip to implement the proposed system. Two substrates were used: one for the patch antenna array and the other one for the feed network and transmission lines. A full-wave simulation model was used to analyze this design and demonstrate the movement of the beam. For this design, the focused beam is moved 310 mm by changing the frequency from 2.2025 GHz to 2.5750 GHz.
- 11 August 2023
- Published by River Publishers in Applied Computational Electromagnetics Society Journal (ACES)
- Vol. 38 (3) , 177–183
Open AccessScanning of the Near-field Focused Beam by Changing Frequency
A new antenna array system is introduced which enables the movement of a near-field focused beam by change of frequency. The shift in the beam is achieved by using multi-wavelength transmission lines between successive elements of the array. At the designed frequency the beam is focused at the focal point. Due to the differences in the transmission line lengths feeding the antenna elements, a progressive phase change occurs between these elements. These phase differences between the elements cause a shift in the beam position. An 8×8 patch antenna array system was designed at 2.4 GHz on a microstrip to implement the proposed system. Two substrates were used: one for the patch antenna array and the other one for the feed network and transmission lines. A full-wave simulation model was used to analyze this design and demonstrate the movement of the beam. For this design, the focused beam is moved 310 mm by changing the frequency from 2.2025 GHz to 2.5750 GHz.
- Open Access
- 30 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7786
Monitoring of Surgically Treated Upper Arm Fracture by Implanted Antenna at 402 MHz
Remote patient monitoring aims to reduce non-essential visits to clinics and hospitals, monitor high-risk patients outside clinical settings, and optimize clinical staff utilization. This paper proposes a new monitoring application for surgically treated upper arm fractures. The humerus fracture should be healed within four to six weeks. Traditional monitoring is conducted through repeated X-ray images and visits to clinical laboratories or hospitals. Our goal is to avoid the expected drawbacks due to repeated exposure to X-rays, such as vomiting, bleeding, fainting, and sometimes the risk of cancer. Furthermore, this study aims to improve the patient’s quality of life during the treatment period by monitoring them at home. The technique depends on implanting a 116 mm length half-wave dipole antenna in the fractured arm and recording the reflection coefficient and the transmitted power at the far-field of it outside the body at 402 MHz. The fracture is represented by an extra layer added to the humerus, which increases the loss of electromagnetic field in the human tissue and then reduces the value of the transmitted power. The existence of fractures shows a change in the transmitted average power densities (APDs) in the range of 11.54% to 15.75%, based on the fracture types, and an increase in reflection coefficients in the range of −22.35 dB to −22.65 dB compared to the normal bone, which monitors the bone healing status. The standard limit of the specific absorption rate was taken into account to guarantee the safety of the human body. Different fracture types were considered and monitored, and CST Microwave Studio was used for simulation. The technique was verified experimentally by measurements carried out on a lifeless front leg animal model. The technique can also be used for the monitoring of ulna and tibia fractures.
- 30 June 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7786
Open AccessMonitoring of Surgically Treated Upper Arm Fracture by Implanted Antenna at 402 MHz
Remote patient monitoring aims to reduce non-essential visits to clinics and hospitals, monitor high-risk patients outside clinical settings, and optimize clinical staff utilization. This paper proposes a new monitoring application for surgically treated upper arm fractures. The humerus fracture should be healed within four to six weeks. Traditional monitoring is conducted through repeated X-ray images and visits to clinical laboratories or hospitals. Our goal is to avoid the expected drawbacks due to repeated exposure to X-rays, such as vomiting, bleeding, fainting, and sometimes the risk of cancer. Furthermore, this study aims to improve the patient’s quality of life during the treatment period by monitoring them at home. The technique depends on implanting a 116 mm length half-wave dipole antenna in the fractured arm and recording the reflection coefficient and the transmitted power at the far-field of it outside the body at 402 MHz. The fracture is represented by an extra layer added to the humerus, which increases the loss of electromagnetic field in the human tissue and then reduces the value of the transmitted power. The existence of fractures shows a change in the transmitted average power densities (APDs) in the range of 11.54% to 15.75%, based on the fracture types, and an increase in reflection coefficients in the range of −22.35 dB to −22.65 dB compared to the normal bone, which monitors the bone healing status. The standard limit of the specific absorption rate was taken into account to guarantee the safety of the human body. Different fracture types were considered and monitored, and CST Microwave Studio was used for simulation. The technique was verified experimentally by measurements carried out on a lifeless front leg animal model. The technique can also be used for the monitoring of ulna and tibia fractures.
- 28 September 2021
- Published by Taylor & Francis in Journal of Electromagnetic Waves and Applications
- Vol. 36 (5) , 722-742
A study on health care monitoring of femoral shaft fracture healing by using implanted antenna for wireless in-to-out body channel communication
This work proposes a health care monitoring method of femoral fractured bone healing as a novel application, based on the oblique incidence case and transmission of electromagnetic waves. The difference between the transmitted average power densities of normal and fractured bone cases is used to monitor the bone healing status. The study demonstrates the in-to-out body channel characteristics regarding the electromagnetic wave propagation and angle of incidence on a multi-layered human tissue in the range of frequencies from 100 MHz to 10 GHz. The monitoring method is presented by the analysis of electromagnetic wave propagation through a multilayer model and simulated by the CST Microwave studio. Fully insulated planar and meander half-wave dipole antennas are designed and used to simulate both types of bone fracture healing. Results show good monitoring of common types of fractures. Verification is carried out by experimental measurements on non-living animal tissues.
- 28 September 2021
- Published by Taylor & Francis in Journal of Electromagnetic Waves and Applications
- Vol. 36 (5) , 722-742
A study on health care monitoring of femoral shaft fracture healing by using implanted antenna for wireless in-to-out body channel communication
This work proposes a health care monitoring method of femoral fractured bone healing as a novel application, based on the oblique incidence case and transmission of electromagnetic waves. The difference between the transmitted average power densities of normal and fractured bone cases is used to monitor the bone healing status. The study demonstrates the in-to-out body channel characteristics regarding the electromagnetic wave propagation and angle of incidence on a multi-layered human tissue in the range of frequencies from 100 MHz to 10 GHz. The monitoring method is presented by the analysis of electromagnetic wave propagation through a multilayer model and simulated by the CST Microwave studio. Fully insulated planar and meander half-wave dipole antennas are designed and used to simulate both types of bone fracture healing. Results show good monitoring of common types of fractures. Verification is carried out by experimental measurements on non-living animal tissues.
- 1 September 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (09) , P09016
Stage II cancer diagnosis using printed antenna implemented on hemispherical model for human breast
- 1 September 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (09) , P09016
Stage II cancer diagnosis using printed antenna implemented on hemispherical model for human breast
- 11 May 2020
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 39 (4) , 791-799
Spurious radiation suppression in microstrip monopulse antenna
Purpose: This paper aims to introduce a new novel microstrip monopulse comparator system to reduce the spurious radiation from the comparator and the feed network for achieving better radiation performance. Design/methodology/approach: Two substrate layers have been used for the microstrip monopulse comparator system. The feed network and the comparator circuits are on the first substrate layer and the microstrip array antenna is on the second layer. The elements of the array antenna are novel square four-sided narrow rectangular slot antennas built on a conducting plane. A commercially available computational software, CST microwave studio, has been used for the analysis of the system. Findings: Two substrate layers have been used for the microstrip monopulse comparator system. The feed network and the comparator circuits are on the first substrate layer and the microstrip array antenna is on the second layer. The elements of the array antenna are novel square four-sided narrow rectangular slot antennas built on a conducting plane. A commercially available computational software, CST microwave studio, has been used for the analysis of the system. Practical implications: The system is proposed for tracking moving targets. Originality/value: Novel slot radiators are introduced as radiating elements in this paper. The antenna arrangement shields the comparator and the feed network circuits, reducing the spurious radiation significantly.
- 11 May 2020
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 39 (4) , 791-799
Spurious radiation suppression in microstrip monopulse antenna
Purpose: This paper aims to introduce a new novel microstrip monopulse comparator system to reduce the spurious radiation from the comparator and the feed network for achieving better radiation performance. Design/methodology/approach: Two substrate layers have been used for the microstrip monopulse comparator system. The feed network and the comparator circuits are on the first substrate layer and the microstrip array antenna is on the second layer. The elements of the array antenna are novel square four-sided narrow rectangular slot antennas built on a conducting plane. A commercially available computational software, CST microwave studio, has been used for the analysis of the system. Findings: Two substrate layers have been used for the microstrip monopulse comparator system. The feed network and the comparator circuits are on the first substrate layer and the microstrip array antenna is on the second layer. The elements of the array antenna are novel square four-sided narrow rectangular slot antennas built on a conducting plane. A commercially available computational software, CST microwave studio, has been used for the analysis of the system. Practical implications: The system is proposed for tracking moving targets. Originality/value: Novel slot radiators are introduced as radiating elements in this paper. The antenna arrangement shields the comparator and the feed network circuits, reducing the spurious radiation significantly.
- 15 January 2018
- Published by Wiley in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
- Vol. 31 (5)
An accurate determination of the phase center position of transitions into 2‐dimensional regions
Correct estimation of the phase centers of the input and output ports is important in Rotman‐type bootlace lens applications. Any shift in the position of the phase center of a port used as a transition between the feed lines and the 2‐dimensional region will cause phase errors, which will create adverse effects on the radiation patterns. This paper introduces a method for determining the phase centers of the transitions radiating into parallel plate regions. A study has been conducted for linearly tapered and multistep transitions (ie, radiators). The results of the study show that the estimated phase centers are displaced from the aperture of the transitions. This displacement is smaller for the multistep transitions compared with the linearly tapered transitions. The simulation results of these transitions also show that, the use of the estimated phase center position reduces the phase errors significantly over wide coverage angles. The results also show that the phase errors do not change with the distance from the aperture. On the other hand, phase errors varies with frequency. These errors are smaller for the stepped transitions compared with the linearly tapered transitions. A separate simulation study of radiation patterns of a linear array fed by a Rotman lens has shown that deterioration occurs in sidelobes and minima levels and a small shift in the off‐axis beam positions when short transitions are used without phase center position correction.
- 15 January 2018
- Published by Wiley in International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
- Vol. 31 (5)
An accurate determination of the phase center position of transitions into 2‐dimensional regions
Correct estimation of the phase centers of the input and output ports is important in Rotman‐type bootlace lens applications. Any shift in the position of the phase center of a port used as a transition between the feed lines and the 2‐dimensional region will cause phase errors, which will create adverse effects on the radiation patterns. This paper introduces a method for determining the phase centers of the transitions radiating into parallel plate regions. A study has been conducted for linearly tapered and multistep transitions (ie, radiators). The results of the study show that the estimated phase centers are displaced from the aperture of the transitions. This displacement is smaller for the multistep transitions compared with the linearly tapered transitions. The simulation results of these transitions also show that, the use of the estimated phase center position reduces the phase errors significantly over wide coverage angles. The results also show that the phase errors do not change with the distance from the aperture. On the other hand, phase errors varies with frequency. These errors are smaller for the stepped transitions compared with the linearly tapered transitions. A separate simulation study of radiation patterns of a linear array fed by a Rotman lens has shown that deterioration occurs in sidelobes and minima levels and a small shift in the off‐axis beam positions when short transitions are used without phase center position correction.
- 1 January 2017
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 25 (4) , 3334-3341
An alternative approach to the design of multiple beam constrained lens antennas
- 1 January 2017
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 25 (4) , 3334-3341
An alternative approach to the design of multiple beam constrained lens antennas
- 14 November 2012
- Published by Wiley in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 23 (6) , 634-638
Improved phase performance for rotman lens
- 14 November 2012
- Published by Wiley in International Journal of RF and Microwave Computer-Aided Engineering
- Vol. 23 (6) , 634-638
Improved phase performance for rotman lens