Matthew Millard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Matthew Millard has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- David W. Franklin
Neuromuscular Diagnostics, Department Health and Sport Sciences, TUM School of Medicine and Health, Technical University of Munich, Munich, Germany
3 shared publications Katja Mombaur
Karlsruhe Institute of Technology, Institute for Anthropomatics and Robotics, Karlsruhe, Germany
3 shared publications- Lizeth H. Sloot
Translational and Clinical Research Institute, Newcastle University, Newcastle upon Tyne, Tyne and Wear, UK
3 shared publications - Walter Herzog
Human performance laboratory, Faculty of Kinesiology University of Calgary Calgary Alberta Canada
3 shared publications - Jörg Fehr
Institute of Engineering and Computational Mechanics, University of Stuttgart, Stuttgart, Germany
2 shared publications - Katja Mombaur
Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications
Latest Publications
- Open Access
- 27 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
The size of the functional base of support decreases with age
Falls occur more often as we age. To identify people at risk of falling, balance analysis requires an accurate base-of-support model. We previously developed a functional base-of-support (fBOS) model for standing young adults and showed that its area is smaller than the footprint area. Our fBOS model is a polygon that contains centre-of-pressure (COP) trajectories recorded as standing participants move their COP in the largest possible loop while keeping their feet flat on the ground. Here we assess how the size of the fBOS changes with age by comparing 38 younger (YA), 14 middle-aged (MA), and 34 older adults (OA). The fBOS area is smaller in older adults: OA area is 58% of the YA area ( $$p<0.001$$ ), and 59% of the MA area ( $$p=0.001$$ ), with no difference between YA and MA. The reduction in fBOS area among the OA is primarily caused by a reduction in the length of the fBOS. In addition, among older adults smaller fBOS areas correlated with a lower score on the Short Physical Performance Battery ( $$\tau$$ =0.28, $$p=0.04$$ ), a reduced walking speed ( $$\tau$$ =0.25, $$p=0.04$$ ), and a higher frailty level ( $$p=0.09$$ ). So that others can extend our work, we have made our fBOS models available online.- 27 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-10
Open AccessThe size of the functional base of support decreases with age
Falls occur more often as we age. To identify people at risk of falling, balance analysis requires an accurate base-of-support model. We previously developed a functional base-of-support (fBOS) model for standing young adults and showed that its area is smaller than the footprint area. Our fBOS model is a polygon that contains centre-of-pressure (COP) trajectories recorded as standing participants move their COP in the largest possible loop while keeping their feet flat on the ground. Here we assess how the size of the fBOS changes with age by comparing 38 younger (YA), 14 middle-aged (MA), and 34 older adults (OA). The fBOS area is smaller in older adults: OA area is 58% of the YA area ( $$p<0.001$$ ), and 59% of the MA area ( $$p=0.001$$ ), with no difference between YA and MA. The reduction in fBOS area among the OA is primarily caused by a reduction in the length of the fBOS. In addition, among older adults smaller fBOS areas correlated with a lower score on the Short Physical Performance Battery ( $$\tau$$ =0.28, $$p=0.04$$ ), a reduced walking speed ( $$\tau$$ =0.25, $$p=0.04$$ ), and a higher frailty level ( $$p=0.09$$ ). So that others can extend our work, we have made our fBOS models available online. - Open Access
The size of the functional base of support decreases with age
Falls occur more often as we age. To identify people at risk of falling, balance analysis requires an accurate base-of-support model. We previously developed a functional base-of-support (fBOS) model for standing young adults and showed that its area is smaller than the footprint area. Our fBOS model is a polygon that contains centre-of-pressure (COP) trajectories recorded as standing participants move their COP in the largest possible loop while keeping their feet flat on the ground. Here we assess how the size of the fBOS changes with age by comparing 38 younger (YA), 14 middle-aged (MA), and 34 older adults (OA). The fBOS area is smaller in older adults: OA area is 58% of the YA area ( p < 0.001), and 59% of the MA area ( p = 0.001), with no difference between YA and MA. The reduction in fBOS area among the OA is primarily caused by a reduction in the length of the fBOS. In addition, among older adults smaller fBOS areas correlated with a lower score on the Short Physical Performance Battery ( τ =0.28, p = 0.04), a reduced walking speed ( τ =0.25, p = 0.04), and a higher frailty level ( p = 0.09). So that others can extend our work, we have made our fBOS models available online.
Open AccessThe size of the functional base of support decreases with age
Falls occur more often as we age. To identify people at risk of falling, balance analysis requires an accurate base-of-support model. We previously developed a functional base-of-support (fBOS) model for standing young adults and showed that its area is smaller than the footprint area. Our fBOS model is a polygon that contains centre-of-pressure (COP) trajectories recorded as standing participants move their COP in the largest possible loop while keeping their feet flat on the ground. Here we assess how the size of the fBOS changes with age by comparing 38 younger (YA), 14 middle-aged (MA), and 34 older adults (OA). The fBOS area is smaller in older adults: OA area is 58% of the YA area ( p < 0.001), and 59% of the MA area ( p = 0.001), with no difference between YA and MA. The reduction in fBOS area among the OA is primarily caused by a reduction in the length of the fBOS. In addition, among older adults smaller fBOS areas correlated with a lower score on the Short Physical Performance Battery ( τ =0.28, p = 0.04), a reduced walking speed ( τ =0.25, p = 0.04), and a higher frailty level ( p = 0.09). So that others can extend our work, we have made our fBOS models available online.
- Open Access
A polygon model of the functional base-of-support during standing improves the accuracy of balance analysis
Mathematical balance models have the potential to identify people at risk of falling. However, most balance models depend on a model of the base-of-support (BOS) of the feet to calculate how well someone is balancing. Here, we evaluate the functional base-of-support (fBOS) during standing: the convex polygon on the bottom of the foot that can support a large fraction of the body’s weight. First, we develop a geometric model of the fBOS by measuring the center-of-pressure (COP) and kinematic data of the feet of 27 younger adults instructed to move their body in large loops without taking a step. Next, we extract a planar convex polygon that contains the COP data. Finally, we compare the area of this fBOS model to a marker-based BOS model before evaluating if the fBOS differs across four common conditions: footwear, stance-width, foot dominance, and during single and double-stance. We found that the fBOS is much smaller (23% the size) than a markerbased BOS model. Our analysis suggests that using the fBOS, rather than a marker-based BOS, can improve the accuracy of the margin-of-stability by 20% of foot width and 16% of the length. In addition, we found that the fBOS area does not differ across footwear ( p = 0.88), stancewidth ( p = 0.88), and foot dominance ( p = 0.68), but during single stance, the fBOS is 17% ( p = 0.0003) larger than during double-stance. The variability of the fBOS area suggests that future studies should establish the repeatability and reliability of the assessment and systematically study the effects of different types of footwear. We have put the fBOS models, example data, and code in the public domain to help others build on our work.
Open AccessA polygon model of the functional base-of-support during standing improves the accuracy of balance analysis
Mathematical balance models have the potential to identify people at risk of falling. However, most balance models depend on a model of the base-of-support (BOS) of the feet to calculate how well someone is balancing. Here, we evaluate the functional base-of-support (fBOS) during standing: the convex polygon on the bottom of the foot that can support a large fraction of the body’s weight. First, we develop a geometric model of the fBOS by measuring the center-of-pressure (COP) and kinematic data of the feet of 27 younger adults instructed to move their body in large loops without taking a step. Next, we extract a planar convex polygon that contains the COP data. Finally, we compare the area of this fBOS model to a marker-based BOS model before evaluating if the fBOS differs across four common conditions: footwear, stance-width, foot dominance, and during single and double-stance. We found that the fBOS is much smaller (23% the size) than a markerbased BOS model. Our analysis suggests that using the fBOS, rather than a marker-based BOS, can improve the accuracy of the margin-of-stability by 20% of foot width and 16% of the length. In addition, we found that the fBOS area does not differ across footwear ( p = 0.88), stancewidth ( p = 0.88), and foot dominance ( p = 0.68), but during single stance, the fBOS is 17% ( p = 0.0003) larger than during double-stance. The variability of the fBOS area suggests that future studies should establish the repeatability and reliability of the assessment and systematically study the effects of different types of footwear. We have put the fBOS models, example data, and code in the public domain to help others build on our work.
- Open Access
- 20 September 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 160, 106740
A benchmark of muscle models to length changes great and small
- 20 September 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 160, 106740
Open AccessA benchmark of muscle models to length changes great and small
- Open Access
- 10 September 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 12
A three filament mechanistic model of musculotendon force and impedance
The force developed by actively lengthened muscle depends on different structures across different scales of lengthening. For small perturbations, the active response of muscle is well captured by a linear-time-invariant (LTI) system: a stiff spring in parallel with a light damper. The force response of muscle to longer stretches is better represented by a compliant spring that can fix its end when activated. Experimental work has shown that the stiffness and damping (impedance) of muscle in response to small perturbations is of fundamental importance to motor learning and mechanical stability, while the huge forces developed during long active stretches are critical for simulating and predicting injury. Outside of motor learning and injury, muscle is actively lengthened as a part of nearly all terrestrial locomotion. Despite the functional importance of impedance and active lengthening, no single muscle model has all these mechanical properties. In this work, we present the viscoelastic-crossbridge active-titin (VEXAT) model that can replicate the response of muscle to length changes great and small. To evaluate the VEXAT model, we compare its response to biological muscle by simulating experiments that measure the impedance of muscle, and the forces developed during long active stretches. In addition, we have also compared the responses of the VEXAT model to a popular Hill-type muscle model. The VEXAT model more accurately captures the impedance of biological muscle and its responses to long active stretches than a Hill-type model and can still reproduce the force-velocity and force-length relations of muscle. While the comparison between the VEXAT model and biological muscle is favorable, there are some phenomena that can be improved: the low frequency phase response of the model, and a mechanism to support passive force enhancement.
- 10 September 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 12
Open AccessA three filament mechanistic model of musculotendon force and impedance
The force developed by actively lengthened muscle depends on different structures across different scales of lengthening. For small perturbations, the active response of muscle is well captured by a linear-time-invariant (LTI) system: a stiff spring in parallel with a light damper. The force response of muscle to longer stretches is better represented by a compliant spring that can fix its end when activated. Experimental work has shown that the stiffness and damping (impedance) of muscle in response to small perturbations is of fundamental importance to motor learning and mechanical stability, while the huge forces developed during long active stretches are critical for simulating and predicting injury. Outside of motor learning and injury, muscle is actively lengthened as a part of nearly all terrestrial locomotion. Despite the functional importance of impedance and active lengthening, no single muscle model has all these mechanical properties. In this work, we present the viscoelastic-crossbridge active-titin (VEXAT) model that can replicate the response of muscle to length changes great and small. To evaluate the VEXAT model, we compare its response to biological muscle by simulating experiments that measure the impedance of muscle, and the forces developed during long active stretches. In addition, we have also compared the responses of the VEXAT model to a popular Hill-type muscle model. The VEXAT model more accurately captures the impedance of biological muscle and its responses to long active stretches than a Hill-type model and can still reproduce the force-velocity and force-length relations of muscle. While the comparison between the VEXAT model and biological muscle is favorable, there are some phenomena that can be improved: the low frequency phase response of the model, and a mechanism to support passive force enhancement.
- Open Access
A benchmark of muscle models to length changes great and small
Digital human body models are used to simulate injuries that occur as a result of vehicle collisions, vibration, sports, and falls. Given enough time the body's musculature can generate force, affect the body's movements, and change the risk of some injuries. The finite-element code LS-DYNA is often used to simulate the movements and injuries sustained by the digital human body models as a result of an accident. In this work, we evaluate the accuracy of the three muscle models in LS-DYNA (MAT_156, EHTMM, and the VEXAT) when simulating a range of experiments performed on isolated muscle: force-length-velocity experiments on maximally and sub-maximally stimulated muscle, active-lengthening experiments, and vibration experiments. The force-length-velocity experiments are included because these conditions are typical of the muscle activity that precedes an accident, while the active-lengthening and vibration experiments mimic conditions that can cause injury. The three models perform similarly during the maximally and sub-maximally activated force-length-velocity experiments, but noticeably differ in response to the active-lengthening and vibration experiments. The VEXAT model is able to generate the enhanced forces of biological muscle during active lengthening, while both the MAT_156 and EHTMM produce too little force. In response to vibration, the stiffness and damping of the VEXAT model closely follows the experimental data while the MAT_156 and EHTMM models differ substantially. The accuracy of the VEXAT model comes from two additional mechanical structures that are missing in the MAT_156 and EHTMM models: viscoelastic cross-bridges, and an active titin filament. To help others build on our work we have made our simulation code publicly available.
Open AccessA benchmark of muscle models to length changes great and small
Digital human body models are used to simulate injuries that occur as a result of vehicle collisions, vibration, sports, and falls. Given enough time the body's musculature can generate force, affect the body's movements, and change the risk of some injuries. The finite-element code LS-DYNA is often used to simulate the movements and injuries sustained by the digital human body models as a result of an accident. In this work, we evaluate the accuracy of the three muscle models in LS-DYNA (MAT_156, EHTMM, and the VEXAT) when simulating a range of experiments performed on isolated muscle: force-length-velocity experiments on maximally and sub-maximally stimulated muscle, active-lengthening experiments, and vibration experiments. The force-length-velocity experiments are included because these conditions are typical of the muscle activity that precedes an accident, while the active-lengthening and vibration experiments mimic conditions that can cause injury. The three models perform similarly during the maximally and sub-maximally activated force-length-velocity experiments, but noticeably differ in response to the active-lengthening and vibration experiments. The VEXAT model is able to generate the enhanced forces of biological muscle during active lengthening, while both the MAT_156 and EHTMM produce too little force. In response to vibration, the stiffness and damping of the VEXAT model closely follows the experimental data while the MAT_156 and EHTMM models differ substantially. The accuracy of the VEXAT model comes from two additional mechanical structures that are missing in the MAT_156 and EHTMM models: viscoelastic cross-bridges, and an active titin filament. To help others build on our work we have made our simulation code publicly available.
- Open Access
- 24 May 2024
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 12
A three filament mechanistic model of musculotendon force and impedance
The force developed by actively lengthened muscle depends on different structures across different scales of lengthening. For small perturbations, the active response of muscle is well captured by a linear-time-invariant (LTI) system: a stiff spring in parallel with a light damper. The force response of muscle to longer stretches is better represented by a compliant spring that can fix its end when activated. Experimental work has shown that the stiffness and damping (impedance) of muscle in response to small perturbations is of fundamental importance to motor learning and mechanical stability, while the huge forces developed during long active stretches are critical for simulating and predicting injury. Outside of motor learning and injury, muscle is actively lengthened as a part of nearly all terrestrial locomotion. Despite the functional importance of impedance and active lengthening, no single muscle model has all of these mechanical properties. In this work, we present the viscoelastic-crossbridge active-titin (VEXAT) model that can replicate the response of muscle to length changes great and small. To evaluate the VEXAT model, we compare its response to biological muscle by simulating experiments that measure the impedance of muscle, and the forces developed during long active stretches. In addition, we have also compared the responses of the VEXAT model to a popular Hill-type muscle model. The VEXAT model more accurately captures the impedance of biological muscle and its responses to long active stretches than a Hill-type model and can still reproduce the force-velocity and force-length relations of muscle. While the comparison between the VEXAT model and biological muscle is favorable, there are some phenomena that can be improved: the low frequency phase response of the model, and a mechanism to support passive force enhancement.
- 24 May 2024
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 12
Open AccessA three filament mechanistic model of musculotendon force and impedance
The force developed by actively lengthened muscle depends on different structures across different scales of lengthening. For small perturbations, the active response of muscle is well captured by a linear-time-invariant (LTI) system: a stiff spring in parallel with a light damper. The force response of muscle to longer stretches is better represented by a compliant spring that can fix its end when activated. Experimental work has shown that the stiffness and damping (impedance) of muscle in response to small perturbations is of fundamental importance to motor learning and mechanical stability, while the huge forces developed during long active stretches are critical for simulating and predicting injury. Outside of motor learning and injury, muscle is actively lengthened as a part of nearly all terrestrial locomotion. Despite the functional importance of impedance and active lengthening, no single muscle model has all of these mechanical properties. In this work, we present the viscoelastic-crossbridge active-titin (VEXAT) model that can replicate the response of muscle to length changes great and small. To evaluate the VEXAT model, we compare its response to biological muscle by simulating experiments that measure the impedance of muscle, and the forces developed during long active stretches. In addition, we have also compared the responses of the VEXAT model to a popular Hill-type muscle model. The VEXAT model more accurately captures the impedance of biological muscle and its responses to long active stretches than a Hill-type model and can still reproduce the force-velocity and force-length relations of muscle. While the comparison between the VEXAT model and biological muscle is favorable, there are some phenomena that can be improved: the low frequency phase response of the model, and a mechanism to support passive force enhancement.
- Open Access
A three filament mechanistic model of musculotendon force and impedance
The force developed by actively lengthened muscle depends on different structures across different scales of lengthening. For small perturbations, the active response of muscle is well captured by a linear-time-invariant (LTI) system: a stiff spring in parallel with a light damper. The force response of muscle to longer stretches is better represented by a compliant spring that can fix its end when activated. Experimental work has shown that the stiffness and damping (impedance) of muscle in response to small perturbations is of fundamental importance to motor learning and mechanical stability, while the huge forces developed during long active stretches are critical for simulating and predicting injury. Outside of motor learning and injury, muscle is actively lengthened as a part of nearly all terrestrial locomotion. Despite the functional importance of impedance and active lengthening, no single muscle model has all of these mechanical properties. In this work, we present the viscoelastic-crossbridge active-titin (VEXAT) model that can replicate the response of muscle to length changes great and small. To evaluate the VEXAT model, we compare its response to biological muscle by simulating experiments that measure the impedance of muscle, and the forces developed during long active stretches. In addition, we have also compared the responses of the VEXAT model to a popular Hill-type muscle model. The VEXAT model more accurately captures the impedance of biological muscle and its responses to long active stretches than a Hill-type model and can still reproduce the force-velocity and force-length relations of muscle. While the comparison between the VEXAT model and biological muscle is favorable, there are some phenomena that can be improved: the low frequency phase response of the model, and a mechanism to support passive force enhancement.
Open AccessA three filament mechanistic model of musculotendon force and impedance
The force developed by actively lengthened muscle depends on different structures across different scales of lengthening. For small perturbations, the active response of muscle is well captured by a linear-time-invariant (LTI) system: a stiff spring in parallel with a light damper. The force response of muscle to longer stretches is better represented by a compliant spring that can fix its end when activated. Experimental work has shown that the stiffness and damping (impedance) of muscle in response to small perturbations is of fundamental importance to motor learning and mechanical stability, while the huge forces developed during long active stretches are critical for simulating and predicting injury. Outside of motor learning and injury, muscle is actively lengthened as a part of nearly all terrestrial locomotion. Despite the functional importance of impedance and active lengthening, no single muscle model has all of these mechanical properties. In this work, we present the viscoelastic-crossbridge active-titin (VEXAT) model that can replicate the response of muscle to length changes great and small. To evaluate the VEXAT model, we compare its response to biological muscle by simulating experiments that measure the impedance of muscle, and the forces developed during long active stretches. In addition, we have also compared the responses of the VEXAT model to a popular Hill-type muscle model. The VEXAT model more accurately captures the impedance of biological muscle and its responses to long active stretches than a Hill-type model and can still reproduce the force-velocity and force-length relations of muscle. While the comparison between the VEXAT model and biological muscle is favorable, there are some phenomena that can be improved: the low frequency phase response of the model, and a mechanism to support passive force enhancement.
- Open Access
- 1 October 2021
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 2, e13
Comparing the risk of low-back injury using model-based optimization: Improved technique versus exoskeleton assistance
Although wearable robotic systems are designed to reduce the risk of low-back injury, it is unclear how effective assistance is, compared to improvements in lifting technique. We use a two-factor block study design to simulate how effective exoskeleton assistance and technical improvements are at reducing the risk of low-back injury when compared to a typical adult lifting a box. The effects of assistance are examined by simulating two different models: a model of just the human participant, and a model of the human participant wearing the SPEXOR exoskeleton. The effects of lifting technique are investigated by formulating two different types of optimal control problems: a least-squares problem which tracks the human participant’s lifting technique, and a minimization problem where the model is free to use a different movement. Different lifting techniques are considered using three different cost functions related to risk factors for low-back injury: cumulative low-back load (CLBL), peak low-back load (PLBL), and a combination of both CLBL and PLBL (HYB). The results of our simulations indicate that an exoskeleton alone can make modest reductions in both CLBL and PLBL. In contrast, technical improvements alone are effective at reducing CLBL, but not PLBL. The largest reductions in both CLBL and PLBL occur when both an exoskeleton and technical improvements are used. While all three of the lifting technique cost functions reduce both CLBL and PLBL, the HYB cost function offers the most balanced reduction in both CLBL and PLBL.
- 1 October 2021
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 2, e13
Open AccessComparing the risk of low-back injury using model-based optimization: Improved technique versus exoskeleton assistance
Although wearable robotic systems are designed to reduce the risk of low-back injury, it is unclear how effective assistance is, compared to improvements in lifting technique. We use a two-factor block study design to simulate how effective exoskeleton assistance and technical improvements are at reducing the risk of low-back injury when compared to a typical adult lifting a box. The effects of assistance are examined by simulating two different models: a model of just the human participant, and a model of the human participant wearing the SPEXOR exoskeleton. The effects of lifting technique are investigated by formulating two different types of optimal control problems: a least-squares problem which tracks the human participant’s lifting technique, and a minimization problem where the model is free to use a different movement. Different lifting techniques are considered using three different cost functions related to risk factors for low-back injury: cumulative low-back load (CLBL), peak low-back load (PLBL), and a combination of both CLBL and PLBL (HYB). The results of our simulations indicate that an exoskeleton alone can make modest reductions in both CLBL and PLBL. In contrast, technical improvements alone are effective at reducing CLBL, but not PLBL. The largest reductions in both CLBL and PLBL occur when both an exoskeleton and technical improvements are used. While all three of the lifting technique cost functions reduce both CLBL and PLBL, the HYB cost function offers the most balanced reduction in both CLBL and PLBL.
- Open Access
- 30 August 2017
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 4
Predicting the Motions and Forces of Wearable Robotic Systems Using Optimal Control
Wearable robotic systems are being developed to prevent injury to the low-back. Designing a wearable robotic system is challenging because it is difficult to predict how the exoskeleton will affect the movement of the wearer. To aid the design of exoskeletons we formulate and numerically solve an optimal control problem (OCP) to predict the movements and forces of a person as they lift a 15 kg box from the ground both without (human-only OCP) and with (with-exo OCP) the aid of an exoskeleton. We model the human body as a sagittal-plane multibody system that is actuated by agonist and antagonist pairs of muscle-torque-generators (MTGs) at each joint. Using the literature as a guide we have derived a set of MTGs that capture the active-torque- angle, passive-torque-angle, and torque-velocity characteristics of the flexor and extensor groups surrounding the hip, knee, ankle, lumbar-spine, shoulder, elbow and wrist. Uniquely these MTGs are continuous to the second derivative and so are compatible with gradient-based optimization. The exoskeleton is modeled as a rigid body mechanism actuated by a motor at the hip and the lumbar spine and coupled to the wearer through kinematic constraints. We evaluate our results by comparing our predictions to experimental recordings of a human subject. Our results indicate that the predicted peak lumbar flexion angles and extension torques of the human-only OCP are within the range reported in the literature. The results of the with-exo OCP indicate that the exoskeleton motors should provide relatively little support during the descent to the box, but apply a substantial amount of support during the ascent phase. The support provided by the lumbar motor is similar in shape to the net moment generated at the L5/S1 joint by the body, however, the support of the hip motor is more complex because it is coupled to the passive forces that are being generated by the hip extensors of the human subject. The simulations developed in this study are specific to lifting motion and a lower-back exoskeleton. However, the framework is applicable for simulating a large range of robotic-assisted human motions.
- 30 August 2017
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 4
Open AccessPredicting the Motions and Forces of Wearable Robotic Systems Using Optimal Control
Wearable robotic systems are being developed to prevent injury to the low-back. Designing a wearable robotic system is challenging because it is difficult to predict how the exoskeleton will affect the movement of the wearer. To aid the design of exoskeletons we formulate and numerically solve an optimal control problem (OCP) to predict the movements and forces of a person as they lift a 15 kg box from the ground both without (human-only OCP) and with (with-exo OCP) the aid of an exoskeleton. We model the human body as a sagittal-plane multibody system that is actuated by agonist and antagonist pairs of muscle-torque-generators (MTGs) at each joint. Using the literature as a guide we have derived a set of MTGs that capture the active-torque- angle, passive-torque-angle, and torque-velocity characteristics of the flexor and extensor groups surrounding the hip, knee, ankle, lumbar-spine, shoulder, elbow and wrist. Uniquely these MTGs are continuous to the second derivative and so are compatible with gradient-based optimization. The exoskeleton is modeled as a rigid body mechanism actuated by a motor at the hip and the lumbar spine and coupled to the wearer through kinematic constraints. We evaluate our results by comparing our predictions to experimental recordings of a human subject. Our results indicate that the predicted peak lumbar flexion angles and extension torques of the human-only OCP are within the range reported in the literature. The results of the with-exo OCP indicate that the exoskeleton motors should provide relatively little support during the descent to the box, but apply a substantial amount of support during the ascent phase. The support provided by the lumbar motor is similar in shape to the net moment generated at the L5/S1 joint by the body, however, the support of the hip motor is more complex because it is coupled to the passive forces that are being generated by the hip extensors of the human subject. The simulations developed in this study are specific to lifting motion and a lower-back exoskeleton. However, the framework is applicable for simulating a large range of robotic-assisted human motions.