Zhaoliang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhaoliang Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Bichen Xiao
Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, Wuhan 430062, China
1 shared publication- Haiyang Yu
The Institute for Biomedical Engineering & Nano Science, School of Medicine, Tongji University, Shanghai 200331, China
1 shared publication Huibin Zhang
Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, Wuhan 430062, China
1 shared publication- Jingwen Qian
Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Hubei Key Laboratory of Polymer Materials, College of New Energy and Electrical Engineering, Hubei University, Wuhan 430062, PR China
1 shared publication - Jinhua Li
Collaborative Innovation Center for Advanced Organic Chemical Materials Co‐constructed by the Province and Ministry Key Laboratory for the Green Preparation and Application of Functional Materials Hubei Key Laboratory of Polymer Materials Ministry of Education College of New Energy and Electrical Engineering Hubei University Wuhan People's Republic of China
1 shared publication Lei Zhang
Collaborative Innovation Center for Advanced Organic Chemical Materials Co-constructed by the Province and Ministry, Key Laboratory for the Green Preparation and Application of Functional Materials, Ministry of Education, Hubei Key Laboratory of Polymer Materials, School of Materials Science and Engineering, Hubei University, Wuhan 430062, China
1 shared publication
Latest Publications
- 1 October 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (40) , 13673-13679
Aptamer-Based Solution-Gated Graphene Transistors for Highly Sensitive and Real-Time Detection of Thrombin Molecules
Thrombin is an important biomarker for various diseases and biochemical reactions. Rapid and real-time detection of thrombin that quickly neutralizes in early coagulation in the body has gained significant attention for its practical applications. Solution-gated graphene transistors (SGGTs) have been widely studied due to their higher sensitivity and low-cost fabrication for chemical and biological sensing applications. In this paper, the ssDNA aptamer with 29 bases was immobilized on the surface of the gate electrode to specifically recognize thrombin. The SGGT sensor achieved high sensitivity with a limit of detection (LOD) up to fM. The LOD was attributed to the amplification function of SGGTs and the suitable aptamer choice. The ssDNA configuration folding induced by thrombin molecules and the electropositivity of thrombin molecules could arouse the same electrical response of SGGTs, helping the device obtain a high sensitivity. The channel current variation of sensors had a good linear relationship with the logarithm of thrombin concentration in the range of 1 fM to 10 nM. The fabricated device also demonstrated a short response time to thrombin molecules, and the response time to the 1 fM thrombin molecules was about 150 s. In summary, the sensing strategy of aptamer-based SGGTs with high sensitivity and high selectivity has a good prospect in medical diagnosis.
- 1 October 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (40) , 13673-13679
Aptamer-Based Solution-Gated Graphene Transistors for Highly Sensitive and Real-Time Detection of Thrombin Molecules
Thrombin is an important biomarker for various diseases and biochemical reactions. Rapid and real-time detection of thrombin that quickly neutralizes in early coagulation in the body has gained significant attention for its practical applications. Solution-gated graphene transistors (SGGTs) have been widely studied due to their higher sensitivity and low-cost fabrication for chemical and biological sensing applications. In this paper, the ssDNA aptamer with 29 bases was immobilized on the surface of the gate electrode to specifically recognize thrombin. The SGGT sensor achieved high sensitivity with a limit of detection (LOD) up to fM. The LOD was attributed to the amplification function of SGGTs and the suitable aptamer choice. The ssDNA configuration folding induced by thrombin molecules and the electropositivity of thrombin molecules could arouse the same electrical response of SGGTs, helping the device obtain a high sensitivity. The channel current variation of sensors had a good linear relationship with the logarithm of thrombin concentration in the range of 1 fM to 10 nM. The fabricated device also demonstrated a short response time to thrombin molecules, and the response time to the 1 fM thrombin molecules was about 150 s. In summary, the sensing strategy of aptamer-based SGGTs with high sensitivity and high selectivity has a good prospect in medical diagnosis.