ZHZain Haider

Zain Haider

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zain Haider has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Millimeter-Wave Induced Heating of Cutaneous Nerves and Capillaries

    by Zain Haider, Julien Modolo, Micaela Liberti, Francesca Apollonio, Maxim Zhadobov

    In this study, we quantify microscale heating at the level of cutaneous nerves and capillaries due to continuous and pulsed plane-wave exposure at 60 GHz. The thermal properties of the nerves and capillaries were derived using mixture equations based on their water content. The electromagnetic problem was solved in conjunction with Pennes bioheat equation and Arrhenius equation using finite element method to evaluate the spatial and temporal evolution of temperature along with thermal damage within cutaneous nerves and capillaries. Although, the maximum power density within the nerve (41.6 kW/m 3 ) and capillary (20 kW/m 3 ) was 37.3% and 30.2% higher than surrounding skin for a continuous exposure at 10 W/m 2 , the peak temperature elevation ( $\Delta T$ ) within the nerve (93.3 n°C) and capillary (90.7 n°C) occurred after 5 $\mu$ s and 10 $\mu$ s of exposure and was 19.2% and 17.7% higher than surrounding skin, respectively. The nerve and capillary attained thermal equilibrium with skin after roughly 10 ms. The maximal $\Delta T$ within the nerve (0.5 °C) and capillary (0.25 °C) due to nano- and micro-second 60 GHz pulses with highest fluence (0.48 kJ/m 2 ) permitted under ICNIRP guidelines was 34% and 24% higher than in the surrounding skin. Ten 3 μs 60 GHz pulses (power density = 13.4 GW/m 2 ) separated by 10 s of cooling period were used to demonstrate the possibility of selective thermal ablation of cutaneous nerves [damage index ( $\mathit {\Omega }$ )=1.1)] without damaging skin ( $\mathit {\Omega }$ = 0.15). The results provide valuable insights into local millimeter-wave induced heating within various skin substructures.


  • Exposure Levels Induced in Curved Body Parts at mmWaves

    by Giulia Sacco, Zain Haider, Maxim Zhadobov

    This study investigates the impact of the ear and the finger curvature on the electromagnetic (EM) power absorption and resulting heating to quantify the potential enhancement of the induced exposure levels compared to commonly used planar tissue models. The analysis is performed at millimeter-wave (mmW) frequencies upcoming for 5G and future generations, with a special attention to $26 \,\mathrm{GHz}$ and $60 \,\mathrm{GHz}$. A cylindrical model is used to calculate EM power density and heat in fingers (radii $\boldsymbol{a\leq }10 \,\mathrm{mm}$) and EM power density in ears ($1 \,\mathrm{mm}\boldsymbol{\leq a\leq }5 \,\mathrm{mm}$). To compute the temperature rise in the ear, the model is modified to account for heat conduction in the tissue connecting the ear to the head. Our results show that for transverse electric (TE) polarization the maximal absorbed power density remains generally lower than for a planar interface (up to $-38.2 \,\%$ at $26 \,\mathrm{GHz}$ and $-18.7 \,\%$ at $60 \,\mathrm{GHz}$) and exceeds this value for transverse magnetic (TM) polarization (up to $72.3 \,\%$ at $26 \,\mathrm{GHz}$ and $15 \,\%$ at $60 \,\mathrm{GHz}$). The resulting heating is always higher than for the planar model. For the ear model ($\boldsymbol{a=}1 \,\mathrm{mm}$), the variations at steady state reach $93.11 \,\%$ at $26 \,\mathrm{GHz}$ and $103.62 \,\%$ at $60 \,\mathrm{GHz}$.


  • Open Access

    High-Resolution Model of Human Skin Appendages for Electromagnetic Dosimetry at Millimeter Waves

    by Zain Haider, Yves Le Drean, Giulia Sacco, Denys Nikolayev, Ronan Sauleau, Maxim Zhadobov

    The purpose of this work is to evaluate local power and electric field distributions inside high-resolution 3D anatomical CAD models of cutaneous appendages at 60 GHz upcoming for 5G/6G. The microscale resolution models of cutaneous nerves, lymphatics, pilosebaceous unit, microvasculature, eccrine sweat glands, Meissner corpuscle and Pacinian corpuscle were designed based on morphometric data and microscopic images. The Maxwell’s and Hanai’s mixture equations were employed to retrieve the complex permittivity of cutaneous appendages based on their free water content. The cutaneous appendages were exposed to a uniform plane wave. The finite element method was used to compute the power loss density ( ${\boldsymbol{PLD}}$ ) and internal electric field ( ${\boldsymbol{E}}$ ). The results indicate that the maximal ${\boldsymbol{PLD}}$ in cutaneous appendages occurred for ${\boldsymbol{E}}$ polarized along their longest dimension. Higher peak ${\boldsymbol{PLD}}$ was observed in high water content cutaneous appendages such as acrosyringium (45%), epidermal axon (37.9%), Pacinian corpuscle (32.5%), blood capillary (30.6%), lymph capillary (20%) and arrector pili muscle (13.5%) compared to the surrounding skin. Higher ${\boldsymbol{E}}$ was detected in low water content hair with the peak ${\boldsymbol{E}}$ 45.1% greater than in surrounding skin. The interfaces of the cutaneous appendages also manifested a boost (23.8%-60.9%) in ${\boldsymbol{PLD}}$ compared to the surrounding skin. Detailed physical interpretation of observed phenomena is provided in the article. These results provide an insight into microscale power deposition in skin at frequencies upcoming for wireless communications.


  • Open Access

    Local Dosimetry at Cellular and Subcellular Level in HF and Millimeter-Wave Bands

    by Zain Haider, Denys Nikolayev, Yves LE Drean, Annalisa DE Angelis, Micaela Liberti, Ronan Sauleau, Maxim Zhadobov

    The aim of this study was to investigate quantitatively local sub-cellular power deposition at frequencies upcoming for wireless power transfer (WPT) and millimeter-wave (mmWave) technologies. The study was performed on a realistic two-dimensional keratinocyte cell model, designed based on electron microscopy images and experimental data on surface area fraction of keratinocyte to explicitly represent nucleus, mitochondria, endoplasmic reticulum, Golgi apparatus and vesicles. The average power loss density ( ${\bm{PLD_{\text{avg}}}}$ ) and electric field ( ${\bm {E_{\text{avg}}}}$ ) were computed by solving Laplace’s equation under quasi-static approximation using the finite element method. The numerical results for the spherical cell model were validated with corresponding analytical solutions. The results showed that ${\bm {E_{\text{avg}}}}$ and ${\bm {PLD_{\text{avg}}}}$ inside the organelles increased with frequency. Nearly, 51.8% and 98.9% of the incident field on the cell penetrated inside the organelles at 6.78 MHz and 60 GHz, respectively. The ${\bm {PLD_{\text{avg}}}}$ within the organelles in average was 35.7% (6.78 MHz) and 1.95% (60 GHz) lower than in the cytoplasm. The ${\bm {E_{\text{avg}}}}$ induced inside nuclear pores (N $_\text{p}$ ) exceeded the incident field by 5 times and 1.1 times at 6.78 MHz and 60 GHz, respectively. The corresponding ${\bm {PLD_{\text{avg}}}}$ within N $_\text{p}$ was 32.7 times (6.78 MHz) and 1.2 times (60 GHz) higher than that of the cytoplasm. The enhancement of ${\bm {PLD_{\text{avg}}}}$ in N $_\text{p}$ suggests that the intracellular traffic is locally exposed to higher exposure levels compared to the background ${\bm {PLD_{\text{avg}}}}$ in cytosol.


  • A Dual-Band Zero-Index Metamaterial Superstrate for Concurrent Antenna Gain Enhancement at 2.4 and 3.5 GHz

    by Zain Haider, Muhammad U. Khan, Hammad M. Cheema

    The classical printed monopole antenna exhibits wideband operation with low gain and an omnidirectional radiation pattern. In order to boost the gain of the antenna at two frequency bands, a novel dual-band zero-index metamaterial (ZIM) based on both electric and magnetic resonance is developed. The printed monopole is also backed by a metallic ground plane for unidirectional radiation pattern towards boreside. The presented unit cell is comprised of two Schurig split-ring resonators nested together in such an arrangement that it leads to a zero refractive index at two distinct frequencies. Using the proposed design methodology, a ZIM is designed operating at 2.4 and 3.5 GHz. To substantiate the improvement in gain, the proposed design is fabricated and used with a cavity-backed printed monopole antenna. The metamaterial superstrate increases the measured realized gain of the printed monopole antenna by 3.2 dB at 3.5 GHz and by 2.5 dB at 2.4 GHz, in agreement with simulations.