Yannik Christian Layer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yannik Christian Layer has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Alexander Isaak
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
7 shared publicationsJulian A. Luetkens
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
6 shared publicationsNarine Mesropyan
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
6 shared publicationsTatjana Dell
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
6 shared publicationsDaniel Kuetting
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
5 shared publicationsPatrick A. Kupczyk
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, Bonn, Germany
5 shared publications
Latest Publications
- Open Access
- 6 May 2026
- Published by Springer Nature in European Radiology
- Vol. 36 (9) , 1-10
Photon counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study
Objectives: Continuous efforts are made to reduce contrast media, improving patient safety, reducing environmental risks, and addressing recurring supply shortages. The aim of this study was to evaluate contrast agent-reduced CT protocols for transcatheter aortic valve reconstruction (TAVR) planning in photon counting detector CT (PCDCT). Materials and methods: 162 BMI-matched examinations with standard dose contrast media (SCD; 80 mL; Iohexol 300 mg/mL; 81 examinations) and reduced contrast media dose (RCD; 50 mL; 81 examinations) for TAVR planning on a PCDCT were included in this retrospective monocentric study. Virtual monoenergetic reconstructions (VMI) at 70 keV, 60 keV and 50 keV of contrast agent-reduced examinations were compared with polyenergetic images. Quantitatively, regions-of-interest (ROIs) were placed in the abdominal aorta, iliac bifurcation, femoral artery, left ventricle and trapezius muscles. Signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Qualitatively, diagnostic quality and contrast were assessed on a visual grading scale of 1 (non-diagnostic) – 5 (excellent) and contrast agent dose was estimated. Results: Averaged, SNR and CNR decreased by 8.71% and 16.78%, respectively, on PCDCT with reduced contrast dose (RCD vs. SCD; both p < 0.001). VMI50keV increased SNR by 44.10% ( p < 0.001) and CNR by 52.73% ( p < 0.001) compared with SCD. In the ascending aorta, SNR increased from 19.80 ± 6.24 (SCD) to 35.78 ± 13.20 (RCD VMI50keV ) and CNR from 18.84 ± 7.78 to 29.77 ± 16.70. Median contrast intensity was 5 for SCD, 4 for RCD CR , and 5 for RCD VMI50keV . Conclusion: The diagnostic efficacy of TAVR planning assessment using PCDCT with minimized contrast agent dosing is preserved, presenting a practical approach to conserve contrast media. Key Points: Question The aim of the study was to implement a PCDCT-adapted contrast media dose protocol to reduce contrast agent volume at sufficient diagnostic quality. Findings PCDCT enables substantial contrast dose reduction for TAVR planning with maintained diagnostic image quality. Low-keV virtual monoenergetic image reconstructions compensate for the reduced iodine concentration. Clinical relevance The study demonstrates the potential of contrast media reduction of PCD-CT in clinical routine. This can benefit patients with renal impairment, for example, and reduce the negative effects of iodinated contrast media on the environment. Graphical
- 6 May 2026
- Published by Springer Nature in European Radiology
- Vol. 36 (9) , 1-10
Open AccessPhoton counting detector CT contrast agent-reduced transcatheter aortic valve reconstruction planning: a comparative study
Objectives: Continuous efforts are made to reduce contrast media, improving patient safety, reducing environmental risks, and addressing recurring supply shortages. The aim of this study was to evaluate contrast agent-reduced CT protocols for transcatheter aortic valve reconstruction (TAVR) planning in photon counting detector CT (PCDCT). Materials and methods: 162 BMI-matched examinations with standard dose contrast media (SCD; 80 mL; Iohexol 300 mg/mL; 81 examinations) and reduced contrast media dose (RCD; 50 mL; 81 examinations) for TAVR planning on a PCDCT were included in this retrospective monocentric study. Virtual monoenergetic reconstructions (VMI) at 70 keV, 60 keV and 50 keV of contrast agent-reduced examinations were compared with polyenergetic images. Quantitatively, regions-of-interest (ROIs) were placed in the abdominal aorta, iliac bifurcation, femoral artery, left ventricle and trapezius muscles. Signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Qualitatively, diagnostic quality and contrast were assessed on a visual grading scale of 1 (non-diagnostic) – 5 (excellent) and contrast agent dose was estimated. Results: Averaged, SNR and CNR decreased by 8.71% and 16.78%, respectively, on PCDCT with reduced contrast dose (RCD vs. SCD; both p < 0.001). VMI50keV increased SNR by 44.10% ( p < 0.001) and CNR by 52.73% ( p < 0.001) compared with SCD. In the ascending aorta, SNR increased from 19.80 ± 6.24 (SCD) to 35.78 ± 13.20 (RCD VMI50keV ) and CNR from 18.84 ± 7.78 to 29.77 ± 16.70. Median contrast intensity was 5 for SCD, 4 for RCD CR , and 5 for RCD VMI50keV . Conclusion: The diagnostic efficacy of TAVR planning assessment using PCDCT with minimized contrast agent dosing is preserved, presenting a practical approach to conserve contrast media. Key Points: Question The aim of the study was to implement a PCDCT-adapted contrast media dose protocol to reduce contrast agent volume at sufficient diagnostic quality. Findings PCDCT enables substantial contrast dose reduction for TAVR planning with maintained diagnostic image quality. Low-keV virtual monoenergetic image reconstructions compensate for the reduced iodine concentration. Clinical relevance The study demonstrates the potential of contrast media reduction of PCD-CT in clinical routine. This can benefit patients with renal impairment, for example, and reduce the negative effects of iodinated contrast media on the environment. Graphical
- Open Access
- 31 October 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (21) , 2777
Photon-Counting Computed Tomography of the Paranasal Sinuses Improves Intraoperative Accuracy of Image-Guided Surgery
Background: Computed tomography (CT)-based image-guided surgery (IGS) is of great importance in functional endoscopic sinus surgery (FESS) and requires IGS-specific imaging protocols to ensure high intraoperative accuracy. This study aimed to compare photon-counting CT (PCCT), dual-energy dual-source CT (DECT), and spectral detector CT (SDCT) of the paranasal sinuses with respect to image quality, IGS accuracy and radiation dose. Methods: A formalin-fixed cadaver skull was examined using PCCT, DECT and SDCT at 100 kV tube voltage with descending tube currents (mAs). The setup of electromagnetic IGS was evaluated using a visual analog scale. Accuracy was analyzed endoscopically using defined anatomical landmarks. Diagnostic image quality as well as bone and soft tissue noise were assessed qualitatively using a 5-point Likert scale and quantitatively by determination of signal-to-noise ratio. Radiation dose was evaluated using the dose length product. Results: While PCCT datasets could be registered and navigated accurately down to 10 mAs (1.5 mm error at 10 mAs), both DECT and SDCT exhibited significantly increased inaccuracies below 40 mAs (4.35/5.15 mm for DECT/SDCT at 25 mAs). Using PCCT therefore enabled a 45% radiation dose reduction at the minimally required dose length product using PCCT. Quantitative and qualitative image quality were superior for PCCT compared to DECT and SDCT. Conclusions: PCCT provides excellent accuracy of anatomical landmarks in IGS with superior image quality of the paranasal sinuses in low-mA scans and substantially reduced radiation exposure.
- 31 October 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (21) , 2777
Open AccessPhoton-Counting Computed Tomography of the Paranasal Sinuses Improves Intraoperative Accuracy of Image-Guided Surgery
Background: Computed tomography (CT)-based image-guided surgery (IGS) is of great importance in functional endoscopic sinus surgery (FESS) and requires IGS-specific imaging protocols to ensure high intraoperative accuracy. This study aimed to compare photon-counting CT (PCCT), dual-energy dual-source CT (DECT), and spectral detector CT (SDCT) of the paranasal sinuses with respect to image quality, IGS accuracy and radiation dose. Methods: A formalin-fixed cadaver skull was examined using PCCT, DECT and SDCT at 100 kV tube voltage with descending tube currents (mAs). The setup of electromagnetic IGS was evaluated using a visual analog scale. Accuracy was analyzed endoscopically using defined anatomical landmarks. Diagnostic image quality as well as bone and soft tissue noise were assessed qualitatively using a 5-point Likert scale and quantitatively by determination of signal-to-noise ratio. Radiation dose was evaluated using the dose length product. Results: While PCCT datasets could be registered and navigated accurately down to 10 mAs (1.5 mm error at 10 mAs), both DECT and SDCT exhibited significantly increased inaccuracies below 40 mAs (4.35/5.15 mm for DECT/SDCT at 25 mAs). Using PCCT therefore enabled a 45% radiation dose reduction at the minimally required dose length product using PCCT. Quantitative and qualitative image quality were superior for PCCT compared to DECT and SDCT. Conclusions: PCCT provides excellent accuracy of anatomical landmarks in IGS with superior image quality of the paranasal sinuses in low-mA scans and substantially reduced radiation exposure.
- Open Access
- 15 August 2025
- Published by Springer Nature in European Radiology Experimental
- Vol. 9 (1) , 77
Photon-counting CT in maxillofacial and temporal bone CT—a comparative analysis of image quality and dose with high-end energy-integrating CT systems
Background: This experimental study aimed to compare the image quality of maxillofacial and temporal bone imaging using different radiation dose settings on current high-end CT systems: photon-counting detector CT (PCDCT), dual-source energy-integrating detector CT (DECT), and dual-layer spectral detector CT (SDCT). Materials and methods: CT scans of a cadaveric human specimen were investigated. Temporal bone imaging was performed with the following parameters: 120 kV and A (high-dose): 140–100 mAs; B (middle-dose): 90–60 mAs; C (low-dose): 50–25 mAs; D (ultra-low-dose): 20–10 mAs. Similarly, for maxillofacial CT: 100 kV and A: 100–80 mAs; B: 70–50 mAs; C: 40–25 mAs; D: 20–10 mAs. Region of interest (ROI)-based noise, SNR, and CNR ratios were calculated for objective assessment of image quality. Subjectively, image quality (IQ) of important anatomic landmarks was assessed using a Likert grading scale from 1 (non-diagnostic) to 5 (excellent). Results: For temporal bone, PCDCT provided excellent-to-good IQ up to low-dose scans for all anatomical landmarks, which was superior to SDCT (excellent-to-sufficient), followed by DECT (good-to-poor): e.g., for C: 4.3 ± 0.5 versus 3.7 ± 0.6 versus 2.9 ± 0.6, p < 0.001. PCDCT had significantly better IQ compared to SDCT in ultra-low-dose settings (D: 3.9 ± 0.4 versus 2.8 ± 0.4, p < 0.001). For maxillofacial CT, no significant differences in IQ were found between all CT systems using high- and middle-dose scans, e.g., B: 3.9 ± 0.5 versus 3.8 ± 0.7 versus 3.8 ± 0.4 (p = 0.81). In low- and ultra-low-dose settings, IQ was similar by PCDCT and SDCT (C: p = 0.17; D: p = 0.99) and superior to that of DECT (C: p < 0.05). Conclusion: PCDCT offers excellent image quality for temporal bone and maxillofacial CT even at ultra-low doses; results were, in some cases, superior to SDCT and DECT. Relevance statement: As PCDCT outperformed modern DECT and SDCT in assessment of maxillofacial and temporal bone CT for image quality and radiation dose, our study suggests that the implementation of PCDCT will improve image quality while reducing radiation exposure in general population. Key Points: This work compares the quality of maxillofacial and temporal bone imaging in PCDCT, DECT, and SDCT. Scans of a cadaveric human specimen were investigated using different radiation doses. PCDCT offers excellent image quality for temporal bone and maxillofacial CT. PCDCT, SDCT, and DECT all showed good image quality overall. Graphical
- 15 August 2025
- Published by Springer Nature in European Radiology Experimental
- Vol. 9 (1) , 77
Open AccessPhoton-counting CT in maxillofacial and temporal bone CT—a comparative analysis of image quality and dose with high-end energy-integrating CT systems
Background: This experimental study aimed to compare the image quality of maxillofacial and temporal bone imaging using different radiation dose settings on current high-end CT systems: photon-counting detector CT (PCDCT), dual-source energy-integrating detector CT (DECT), and dual-layer spectral detector CT (SDCT). Materials and methods: CT scans of a cadaveric human specimen were investigated. Temporal bone imaging was performed with the following parameters: 120 kV and A (high-dose): 140–100 mAs; B (middle-dose): 90–60 mAs; C (low-dose): 50–25 mAs; D (ultra-low-dose): 20–10 mAs. Similarly, for maxillofacial CT: 100 kV and A: 100–80 mAs; B: 70–50 mAs; C: 40–25 mAs; D: 20–10 mAs. Region of interest (ROI)-based noise, SNR, and CNR ratios were calculated for objective assessment of image quality. Subjectively, image quality (IQ) of important anatomic landmarks was assessed using a Likert grading scale from 1 (non-diagnostic) to 5 (excellent). Results: For temporal bone, PCDCT provided excellent-to-good IQ up to low-dose scans for all anatomical landmarks, which was superior to SDCT (excellent-to-sufficient), followed by DECT (good-to-poor): e.g., for C: 4.3 ± 0.5 versus 3.7 ± 0.6 versus 2.9 ± 0.6, p < 0.001. PCDCT had significantly better IQ compared to SDCT in ultra-low-dose settings (D: 3.9 ± 0.4 versus 2.8 ± 0.4, p < 0.001). For maxillofacial CT, no significant differences in IQ were found between all CT systems using high- and middle-dose scans, e.g., B: 3.9 ± 0.5 versus 3.8 ± 0.7 versus 3.8 ± 0.4 (p = 0.81). In low- and ultra-low-dose settings, IQ was similar by PCDCT and SDCT (C: p = 0.17; D: p = 0.99) and superior to that of DECT (C: p < 0.05). Conclusion: PCDCT offers excellent image quality for temporal bone and maxillofacial CT even at ultra-low doses; results were, in some cases, superior to SDCT and DECT. Relevance statement: As PCDCT outperformed modern DECT and SDCT in assessment of maxillofacial and temporal bone CT for image quality and radiation dose, our study suggests that the implementation of PCDCT will improve image quality while reducing radiation exposure in general population. Key Points: This work compares the quality of maxillofacial and temporal bone imaging in PCDCT, DECT, and SDCT. Scans of a cadaveric human specimen were investigated using different radiation doses. PCDCT offers excellent image quality for temporal bone and maxillofacial CT. PCDCT, SDCT, and DECT all showed good image quality overall. Graphical
- Open Access
- 25 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Accelerated diffusion-weighted imaging of the prostate employing echo planar imaging with compressed SENSE based reconstruction
Aim was to evaluate accelerated diffusion-weighted imaging (DWI) of the prostate using echo planar imaging with compressed SENSE based reconstruction (EPICS) and assess its performance in comparison to conventional DWI with parallel imaging. In this single-center, prospective study, 35 men with clinically suspected prostate cancer underwent prostate MRI at 3T. In each patient, two different DWI sequences, one with 3 b-values (b = 100, 400, 800s/mm²) for ADC-calculation and one with b = 1500s/mm², were acquired with conventional SENSE and with EPICS. Quantitative evaluation was done by regions-of-interest (ROIs) analysis of prostate lesions and normal appearing peripheral zones (PZ). Apparent contrast-to-noise (aCNR) and apparent signal-to-noise ratios (aSNR) were calculated. Mean ADC and coefficient of variation (CV) of ADC were compared. For qualitative assessment, artifacts, lesion conspicuity, and overall image quality were rated using a 5-point-Likert-scale (1: nondiagnostic to 5: excellent). Additionally, the Prostate Imaging Reporting and Data System (PIRADS 2.1) was rated for DWI. The average total scan time reduction with EPICS was 43%. Quantitative analysis showed no significant differences between conventional SENSE and EPICS, neither for aSNRLesion (e.g. b1500conv: 24.37 ± 10.28 vs. b1500EPICS: 24.08 ± 12.2; p = 0.98) and aCNRLesion (e.g. b1500conv:9.53 ± 7.22 vs. b1500EPICS:8.88 ± 6.16; p = 0.55) nor for aSNRPZ (e.g. b1500conv:15.18 ± 6.48 vs. b1500EPICS: 15 ± 7.4; p = 0.94). Rating of artifacts, lesion conspicuity, overall image quality and PIRADS-scores yielded comparable results for the two techniques (e.g. lesion conspicuity for ADCconv: 4(2–5) vs. ADCEPICS 4(2–5); p = 0.99 and for b1500conv: 4(2–5) vs. b1500EPICS 4(2–5); p = 0.25). Overall, accelerated DWI of the prostate using EPICS significantly reduced acquisition time without compromising image quality compared to conventional DWI.
- 25 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessAccelerated diffusion-weighted imaging of the prostate employing echo planar imaging with compressed SENSE based reconstruction
Aim was to evaluate accelerated diffusion-weighted imaging (DWI) of the prostate using echo planar imaging with compressed SENSE based reconstruction (EPICS) and assess its performance in comparison to conventional DWI with parallel imaging. In this single-center, prospective study, 35 men with clinically suspected prostate cancer underwent prostate MRI at 3T. In each patient, two different DWI sequences, one with 3 b-values (b = 100, 400, 800s/mm²) for ADC-calculation and one with b = 1500s/mm², were acquired with conventional SENSE and with EPICS. Quantitative evaluation was done by regions-of-interest (ROIs) analysis of prostate lesions and normal appearing peripheral zones (PZ). Apparent contrast-to-noise (aCNR) and apparent signal-to-noise ratios (aSNR) were calculated. Mean ADC and coefficient of variation (CV) of ADC were compared. For qualitative assessment, artifacts, lesion conspicuity, and overall image quality were rated using a 5-point-Likert-scale (1: nondiagnostic to 5: excellent). Additionally, the Prostate Imaging Reporting and Data System (PIRADS 2.1) was rated for DWI. The average total scan time reduction with EPICS was 43%. Quantitative analysis showed no significant differences between conventional SENSE and EPICS, neither for aSNRLesion (e.g. b1500conv: 24.37 ± 10.28 vs. b1500EPICS: 24.08 ± 12.2; p = 0.98) and aCNRLesion (e.g. b1500conv:9.53 ± 7.22 vs. b1500EPICS:8.88 ± 6.16; p = 0.55) nor for aSNRPZ (e.g. b1500conv:15.18 ± 6.48 vs. b1500EPICS: 15 ± 7.4; p = 0.94). Rating of artifacts, lesion conspicuity, overall image quality and PIRADS-scores yielded comparable results for the two techniques (e.g. lesion conspicuity for ADCconv: 4(2–5) vs. ADCEPICS 4(2–5); p = 0.99 and for b1500conv: 4(2–5) vs. b1500EPICS 4(2–5); p = 0.25). Overall, accelerated DWI of the prostate using EPICS significantly reduced acquisition time without compromising image quality compared to conventional DWI.
- 1 March 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (3) , e241677
Photon-counting CT–derived Quantification of Hepatic Fat Fraction: A Clinical Validation Study
Liver fat quantification on contrast-enhanced photon-counting CT scans was accurate compared with the reference standard MRI proton density fat fraction.
- 1 March 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (3) , e241677
Photon-counting CT–derived Quantification of Hepatic Fat Fraction: A Clinical Validation Study
Liver fat quantification on contrast-enhanced photon-counting CT scans was accurate compared with the reference standard MRI proton density fat fraction.
- 3 January 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (7) , 463-469
Artifact Reduction in Interventional Devices Using Virtual Monoenergetic Images and Iterative Metal Artifact Reduction on Photon-Counting Detector CT
Objectives: The aim of this study was to assess the impact of an iterative metal artifact reduction (iMAR) algorithm combined with virtual monoenergetic images (VMIs) for artifact reduction in photon-counting detector computed tomography (PCDCT) during interventions. Materials and Methods: Using an abdominal phantom, we conducted evaluations on the efficacy of iMAR and VMIs for mitigating image artifacts during interventions on a PCDCT. Four different puncture devices were employed under 2 scan modes (QuantumSn at 100 kV, Quantumplus at 140 kV) to simulate various clinical scenarios. Image reconstructions were initially performed without iMAR and subsequently with iMAR settings. The latter was tested with 7 different metal presets for each case. Furthermore, iMAR-reconstructed images were paired with VMIs at energy levels of 70 keV, 110 keV, 150 keV, and 190 keV. Qualitative assessments were conducted to evaluate image quality, artifact expression, and the emergence of new artifacts using a Likert scale. Image quality was rated on a scale of 1 (nondiagnostic) to 5 (excellent), whereas artifact severity was rated from 0 (none) to 5 (massive). Preferences for specific iMAR presets were documented. Quantitative analysis involved calculating Hounsfield unit (HU) differences between artifact-rich and artifact-free tissues. Results: Overall, 96 different scanning series were evaluated. The optimal combination for artifact reduction was found to be iMAR neurocoils with VMIs at 150 keV and 190 keV, showcasing the most substantial reduction in artifacts with a median rating of 1 (standard: 4). VMIs at higher keV levels, such as 190 keV, resulted in reduced image quality, as indicated by a median rating of 3 (compared with 70 keV with a median of 5). Newly emerged artifact expression related to reconstructions varied among intervention devices, with iMAR thoracic coils exhibiting the least extent of artifacts (median: 2) and iMAR neurocoils displaying the most pronounced artifacts (median: 4). Qualitative analysis favored the combination of iMAR neurocoils with VMIs at 70 keV, showcasing the best results. Conversely, quantitative analysis revealed that the combination of iMAR neurocoils with VMIs at 190 keV yielded the best results, with an average artifact expression of 20.06 HU (standard: 167.98 HU; P < 0.0001). Conclusions: The study underscores a substantial reduction in artifacts associated with intervention devices during PCDCT scans through the synergistic application of VMI and iMAR techniques. Specifically, the combination of VMIs at 70 keV with iMAR neurocoils was preferred, leading to enhanced diagnostic assessability of surrounding tissues and target lesions. The study demonstrates the potential of iMAR and VMIs for PCDCT-guided interventions. These advancements could improve accuracy, safety, efficiency, and patient outcomes in clinical practice.
- 3 January 2025
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 60 (7) , 463-469
Artifact Reduction in Interventional Devices Using Virtual Monoenergetic Images and Iterative Metal Artifact Reduction on Photon-Counting Detector CT
Objectives: The aim of this study was to assess the impact of an iterative metal artifact reduction (iMAR) algorithm combined with virtual monoenergetic images (VMIs) for artifact reduction in photon-counting detector computed tomography (PCDCT) during interventions. Materials and Methods: Using an abdominal phantom, we conducted evaluations on the efficacy of iMAR and VMIs for mitigating image artifacts during interventions on a PCDCT. Four different puncture devices were employed under 2 scan modes (QuantumSn at 100 kV, Quantumplus at 140 kV) to simulate various clinical scenarios. Image reconstructions were initially performed without iMAR and subsequently with iMAR settings. The latter was tested with 7 different metal presets for each case. Furthermore, iMAR-reconstructed images were paired with VMIs at energy levels of 70 keV, 110 keV, 150 keV, and 190 keV. Qualitative assessments were conducted to evaluate image quality, artifact expression, and the emergence of new artifacts using a Likert scale. Image quality was rated on a scale of 1 (nondiagnostic) to 5 (excellent), whereas artifact severity was rated from 0 (none) to 5 (massive). Preferences for specific iMAR presets were documented. Quantitative analysis involved calculating Hounsfield unit (HU) differences between artifact-rich and artifact-free tissues. Results: Overall, 96 different scanning series were evaluated. The optimal combination for artifact reduction was found to be iMAR neurocoils with VMIs at 150 keV and 190 keV, showcasing the most substantial reduction in artifacts with a median rating of 1 (standard: 4). VMIs at higher keV levels, such as 190 keV, resulted in reduced image quality, as indicated by a median rating of 3 (compared with 70 keV with a median of 5). Newly emerged artifact expression related to reconstructions varied among intervention devices, with iMAR thoracic coils exhibiting the least extent of artifacts (median: 2) and iMAR neurocoils displaying the most pronounced artifacts (median: 4). Qualitative analysis favored the combination of iMAR neurocoils with VMIs at 70 keV, showcasing the best results. Conversely, quantitative analysis revealed that the combination of iMAR neurocoils with VMIs at 190 keV yielded the best results, with an average artifact expression of 20.06 HU (standard: 167.98 HU; P < 0.0001). Conclusions: The study underscores a substantial reduction in artifacts associated with intervention devices during PCDCT scans through the synergistic application of VMI and iMAR techniques. Specifically, the combination of VMIs at 70 keV with iMAR neurocoils was preferred, leading to enhanced diagnostic assessability of surrounding tissues and target lesions. The study demonstrates the potential of iMAR and VMIs for PCDCT-guided interventions. These advancements could improve accuracy, safety, efficiency, and patient outcomes in clinical practice.
- Top Cited Papers
- 1 January 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (1) , e240895
Privacy-ensuring Open-weights Large Language Models Are Competitive with Closed-weights GPT-4o in Extracting Chest Radiography Findings from Free-Text Reports
Privacy-ensuring, open-weights large language models showed great potential in the extraction of structured content from free-text radiology reports, facilitating the secondary use of clinical databases for applications in data-driven medicine.
- 1 January 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 314 (1) , e240895
Top Cited PapersPrivacy-ensuring Open-weights Large Language Models Are Competitive with Closed-weights GPT-4o in Extracting Chest Radiography Findings from Free-Text Reports
Privacy-ensuring, open-weights large language models showed great potential in the extraction of structured content from free-text radiology reports, facilitating the secondary use of clinical databases for applications in data-driven medicine.
- Open Access
- 26 November 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (1) , 183-194
Rapid and motion-robust pediatric brain imaging: T2-weighted turbo-spin-echo PROPELLER acquisition with compressed sensing
Background: In pediatric magnetic resonance imaging (MRI), reducing the rate of non-diagnostic scans due to artifacts and shortening acquisition time are crucial not only for economic reasons but also to minimize sedation or general anesthesia. Objective: Enabling faster and motion-robust MRI of the brain in infants and children using a novel, enhanced compressed sensing (CS) algorithm in combination with a turbo-spin-echo T2-weighted sequence utilizing the PROPELLER-technique (periodically rotated overlapping parallel lines with enhanced reconstruction; T2PROPELLER CS). Materials and methods: This prospective study included 31 patients (8.0 ± 4.7 years, 15 males) undergoing a clinically indicated MRI examination of the brain on a 3-T scanner. The T2PROPELLER CS sequence was compared to a conventional, CS-accelerated Cartesian turbo-spin-echo T2-weighted sequence (T2Cartesian CS). Apparent contrast-to-noise ratio (aCNR) and signal-to-noise ratio (aSNR) were calculated. Three blinded radiologists independently rated both sequences twice qualitatively on a 5-point Likert-scale from 1–5 (non-diagnostic–excellent) for artifacts, image sharpness, basal ganglia delineation, lesion conspicuity, and overall image quality. Statistical analysis was performed using the Wilcoxon signed-rank test and paired sample t test. Intra- and interrater reliability of qualitative image assessment was evaluated by computing Krippendorff’s $$\alpha$$ reliability estimates. Results: The average acquisition time of the T2PROPELLER CS (189 ± 27 s) was 31% shorter than that of the T2Cartesian CS sequence (273 ± 21 s; P < 0.001). aCNR (7.7 ± 4.6 vs. 6.2 ± 2.8; P = 0.004) and aSNR (24.8 ± 9.7 vs. 18.8 ± 5.5; P < 0.001) were higher for the T2Cartesian CS compared to the T2PROPELLER CS sequence. The T2PROPELLER CS sequence significantly reduced (motion-)artifacts (P < 0.001) and increased image sharpness (P < 0.001), basal ganglia delineation (P<0.001), lesion conspicuity (raters 1 and 2, P < 0.001; rater 3, P = 0.004), and overall image quality (P < 0.001). Metal artifacts were prominent in both sequences, though slightly more pronounced in the T2PROPELLER CS sequence. Conclusion: The T2PROPELLER CS sequence enables faster and motion-robust imaging of the brain in infants and children, reducing the rate of non-diagnostic scans and potentially allowing sedation or general anesthesia to be minimized in the future. Graphical- 26 November 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (1) , 183-194
Open AccessRapid and motion-robust pediatric brain imaging: T2-weighted turbo-spin-echo PROPELLER acquisition with compressed sensing
Background: In pediatric magnetic resonance imaging (MRI), reducing the rate of non-diagnostic scans due to artifacts and shortening acquisition time are crucial not only for economic reasons but also to minimize sedation or general anesthesia. Objective: Enabling faster and motion-robust MRI of the brain in infants and children using a novel, enhanced compressed sensing (CS) algorithm in combination with a turbo-spin-echo T2-weighted sequence utilizing the PROPELLER-technique (periodically rotated overlapping parallel lines with enhanced reconstruction; T2PROPELLER CS). Materials and methods: This prospective study included 31 patients (8.0 ± 4.7 years, 15 males) undergoing a clinically indicated MRI examination of the brain on a 3-T scanner. The T2PROPELLER CS sequence was compared to a conventional, CS-accelerated Cartesian turbo-spin-echo T2-weighted sequence (T2Cartesian CS). Apparent contrast-to-noise ratio (aCNR) and signal-to-noise ratio (aSNR) were calculated. Three blinded radiologists independently rated both sequences twice qualitatively on a 5-point Likert-scale from 1–5 (non-diagnostic–excellent) for artifacts, image sharpness, basal ganglia delineation, lesion conspicuity, and overall image quality. Statistical analysis was performed using the Wilcoxon signed-rank test and paired sample t test. Intra- and interrater reliability of qualitative image assessment was evaluated by computing Krippendorff’s $$\alpha$$ reliability estimates. Results: The average acquisition time of the T2PROPELLER CS (189 ± 27 s) was 31% shorter than that of the T2Cartesian CS sequence (273 ± 21 s; P < 0.001). aCNR (7.7 ± 4.6 vs. 6.2 ± 2.8; P = 0.004) and aSNR (24.8 ± 9.7 vs. 18.8 ± 5.5; P < 0.001) were higher for the T2Cartesian CS compared to the T2PROPELLER CS sequence. The T2PROPELLER CS sequence significantly reduced (motion-)artifacts (P < 0.001) and increased image sharpness (P < 0.001), basal ganglia delineation (P<0.001), lesion conspicuity (raters 1 and 2, P < 0.001; rater 3, P = 0.004), and overall image quality (P < 0.001). Metal artifacts were prominent in both sequences, though slightly more pronounced in the T2PROPELLER CS sequence. Conclusion: The T2PROPELLER CS sequence enables faster and motion-robust imaging of the brain in infants and children, reducing the rate of non-diagnostic scans and potentially allowing sedation or general anesthesia to be minimized in the future. Graphical - Open Access
- 4 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100–190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1–3) and 1 (1–3); e.g. VMI130 keV 2 (1–5); p < 0.0001 and 2 (1–4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: − 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.
- 4 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessUse of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100–190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1–3) and 1 (1–3); e.g. VMI130 keV 2 (1–5); p < 0.0001 and 2 (1–4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: − 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.