HFHongxiang Fu

Hongxiang Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongxiang Fu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design, Verify, Deploy: The New Platform-Based Design Paradigm for Large-Scale Energy System Retrofits

    by Michael Wetter, Matthias Sulzer, Eric Nyenhuis, Jianjun Hu, Hongxiang Fu, Remi Patureau, Virak Dee, Andrew Tech

    Large-scale building retrofits involve complex system integration across energy, controls, and infrastructure domains. Managing this complexity at scale is a fundamental challenge to address the large retrofit need of the buildings sector. To address this, we developed and demonstrated Platform-Based Design (PBD) for an energy system retrofit of 17 buildings at Joint Base Andrews. PBD replaces ad-hoc engineering with a data-driven, sequential system-refinement workflow that uses reusable models of increasing fidelity to verify candidate solutions against formal requirements.Initial multi-objective optimizations using Mixed-Integer Linear Programming (MILP) identified a geothermal-coupled Thermal Energy Network (TEN) with photovoltaics and batteries as the optimal configuration. However, the dynamic thermal behavior of geothermal coupled energy systems cannot be captured by the optimization models. A subsequent de-risking phase using fully coupled, nonlinear dynamic simulations via the Modelica Buildings Library revealed an overestimation of the borefield's heat transfer capacity. Proceeding without this de-risking would have resulted in physical installation failures and multi-million-dollar change orders.The Pareto-optimal TEN design reduces imported energy by 74% and peak electrical demand by 45% relative to a conventional gas heating and air-source chiller cooling baseline. It enhances energy resilience with a levelized cost of energy of $0.210/kWh and a 6% life-cycle cost increase. The PBD process further identified over $2 million in investment costs and $300,000 in annualized life-cycle cost savings, recovering the cost of the advanced design process. By replacing physical testing with virtual verification, PBD provides a formal, digital paradigm for executing reliable, cost-effective energy retrofits at scale.

  • Open Access

    Design, Verify, Deploy: The New Platform-Based Design Paradigm for Large-Scale Energy System Retrofits

    by Michael Wetter, Matthias Sulzer, Eric Nyenhuis, Jianjun Hu, Hongxiang Fu, Remi Patureau, Virak Dee, Andrew Tech

    Achieving energy security and resilience in large-scale building retrofits requires a scalable process to manage complex system integration. This is critical for entities like the U.S. Department of Defense (DoD), which faces the daunting task of retrofitting an estimated two military bases per month to maintain a 25-year upgrade cycle. To address this, we developed and demonstrated Platform-Based Design (PBD) for an energy system retrofit of 17 buildings at Joint Base Andrews. PBD replaces traditional, ad-hoc engineering with a data-driven, sequential workflow using reusable models of increasing fidelity to verify candidate solutions against functional requirements. Initial multi-objective optimizations using Mixed-Integer Linear Programming (MILP) identified a geothermal-coupled Thermal Energy Network (TEN) integrated with photovoltaics and batteries as the ideal configuration. A subsequent de-risking phase that utilized fully coupled, nonlinear dynamic simulations via the Modelica Buildings Library revealed critical design flaws, including an overestimation of the geothermal borefield’s dynamic heat transfer. The model-based identification of these design flaws prevented recommendations of a design that would result in physical installation failures and multi-million dollar change orders. The finalized, Pareto-optimal TEN design reduces imported energy by 74% and peak electrical demand by 45% relative to a conventional gas heating and air-source chiller cooling baseline. It enhances mission resilience with a levelized cost of energy of $0.210/kWh and only a marginal 6% life-cycle cost increase. Furthermore, the PBD process identified over $2 million in investment costs and $300,000 in annualized life cycle cost savings, paying for the advanced design process itself. Ultimately, by shifting from physical testing to virtual verification, PBD provides the formalized, digitalized paradigm essential for executing reliable, cost-effective energy retrofits at a massive scale.

  • Open Access

    Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

    by Ettore Zanetti, David Blum, Hongxiang Fu, Chris Weyandt, Marco Pritoni, Mary Ann Piette


  • Automated and comprehensive day-type grouping in building energy baseline models with a series of statistical inferences

    by Hongxiang Fu, Juan-Carlos Baltazar, David E. Claridge

    A good model fit is the central pillar of building energy consumption baseline modelling. Energy analysts often must undertake the arduous and tedious task of separating measured energy consumption data into groups reflecting a building’s multiple operation modes. While a building sometimes has more than a weekday/weekend shift, a detailed operation schedule may not be easily available or accurate. If not treated carefully, operational idiosyncrasies can limit the performance of the baseline model. So far, the data separation methods deployed in published articles are either too simple to be effective for complex schedules or so intricate that many working in the field may find them inconvenient to implement. The proposed procedure in this study instead adopts a novel approach that automatically and comprehensively examines all data separation possibilities with pre-defined elementary day-types through a series of lack-of-fit F-tests. It then suggests a best one that balances model accuracy and simplicity. This procedure was tested on measured energy consumption data of 76 buildings and found to weigh simplicity more heavily than traditional statistical complexity-penalising metrics. It improved the CV-RMSE by 7.6 percentage points on average and helped extract information from the data to understand better the buildings’ energy consumption patterns.