Kaleem Nawaz Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kaleem Nawaz Khan has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Salman Khan
Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
4 shared publications - Anwar Ghani
Department of Computer Science, School of Engineering and Digital Sciences, Nazarbayev University, Astana, Kazakhstan
2 shared publications - Fawad Ahmad
Rochester Institute of Technology, Rochester, NY, USA
2 shared publications - Muhammad Enamul Hoque Chowdhury
Department of Electrical Engineering, Qatar University, Doha P.O. Box 2713, Qatar
2 shared publications - Abdulwahed Fahad Alrefaei
Department of Zoology, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451, Saudi Arabia
1 shared publication - Akhtar Iqbal
Department of Environmental Sciences, COMSATS University Islamabad, Abbottabad, Pakistan
1 shared publication
Latest Publications
- Open Access
- 10 May 2026
- Published by Association for Computing Machinery (ACM)
- p. 775-788
ARC: Accurate, Real-Time, and Scalable Multi-Vehicle Cooperative Perception
- 10 May 2026
- Published by Association for Computing Machinery (ACM)
- p. 775-788
Open AccessARC: Accurate, Real-Time, and Scalable Multi-Vehicle Cooperative Perception
- Open Access
- 3 June 2024
- Published by Association for Computing Machinery (ACM)
- p. 547-560
VRF: Vehicle Road-side Point Cloud Fusion
Autonomous vehicles and human drivers are prone to line-of-sight limitations. Road-side mounted 3D sensors like LiDARs can augment a vehicle's on-board perception. However, this entails fusing 3D frames at low latency and high accuracy. Road-side and vehicle 3D frames are captured from different viewpoints. This adversely affects alignment accuracy and can be computationally expensive. To this end, VRF optimizes for both latency and accuracy by decoupling the alignment process into indirect and direct alignments. First, VRF indirectly aligns the 3D frames by aligning them to a common reference point i.e., a vehicle's on-board 3D map. Then, it directly aligns the two point clouds to refine this alignment. To ensure high accuracy, it incorporates novel offline registration and alignment accuracy forecasting modules. To ensure low latency, it uses a fast fusion pipeline that caches previous and offline computations. To our knowledge, VRF is the first vehicle road-side cooperative system to ensure cm-level accuracy and end-to-end latency less than 20 ms. Most importantly, its latency is below the 100 ms threshold required for autonomous vehicles to react to external events. Finally, VRF can improve reaction time to external events by as much as 5 seconds1.
- 3 June 2024
- Published by Association for Computing Machinery (ACM)
- p. 547-560
Open AccessVRF: Vehicle Road-side Point Cloud Fusion
Autonomous vehicles and human drivers are prone to line-of-sight limitations. Road-side mounted 3D sensors like LiDARs can augment a vehicle's on-board perception. However, this entails fusing 3D frames at low latency and high accuracy. Road-side and vehicle 3D frames are captured from different viewpoints. This adversely affects alignment accuracy and can be computationally expensive. To this end, VRF optimizes for both latency and accuracy by decoupling the alignment process into indirect and direct alignments. First, VRF indirectly aligns the 3D frames by aligning them to a common reference point i.e., a vehicle's on-board 3D map. Then, it directly aligns the two point clouds to refine this alignment. To ensure high accuracy, it incorporates novel offline registration and alignment accuracy forecasting modules. To ensure low latency, it uses a fast fusion pipeline that caches previous and offline computations. To our knowledge, VRF is the first vehicle road-side cooperative system to ensure cm-level accuracy and end-to-end latency less than 20 ms. Most importantly, its latency is below the 100 ms threshold required for autonomous vehicles to react to external events. Finally, VRF can improve reaction time to external events by as much as 5 seconds1.
- Open Access
- 7 November 2023
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 11, 1277182
Assessment of heavy metals among auto workers in metropolitan city: a case study
In recent decades, heavy metals (HMs) have emerged as a global health concern. Unfortunately, in Pakistan, there is a general lack of awareness regarding the potential health risks associated with HMs pollution among automobile workers. Herein, we investigated the concentration of heavy metals such as lead (Pb), cadmium (Cd), and chromium (Cr) among automobile workers who were occupationally exposed in Mingora City, Khyber Pakhtunkhwa, Pakistan. Three different automobile groups, i.e., battery recyclers, spray painters, and mechanics were studied in detail. A total of 40 blood samples were collected from automobile workers groups while 10 blood samples were collected as control individuals from different locations in the study area. We investigated heavy metals concentration with a standard method using an atomic absorption spectrometer AAS (PerkinElmer Analyst 700, United States). Based on our findings, the battery recycling group displayed the most elevated Pb levels (5.45 ± 2.11 μg/dL), exceeding those of both the spray painters’ group (5.12 ± 1.98 μg/dL) and the mechanics’ group (3.79 ± 2.21 μg/dL). This can be attributed to their higher exposure to Pb pollution resulting from the deterioration, dismantling, grinding, or crushing of old batteries. In the context of chromium (Cr) exposure, a similar trend was observed among the battery recycling group, as well as the spray painters and mechanics groups. However, in the case of cadmium (Cd), the mechanics’ group exhibited the highest level of exposure (4.45 ± 0.65 μg/dL), surpassing the battery recycling group (1.17 ± 0.45 μg/dL) and the spray painters’ group (1.35 ± 0.69 μg/dL), which was attributed to their greater exposure to welding fumes and other activities in their workplace. We believe that our findings will encourage regulatory measures to improve the health of automobile workers. However, further work is needed to determine various health-related issues associated with heavy metal exposure among automobile workers.
- 7 November 2023
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 11, 1277182
Open AccessAssessment of heavy metals among auto workers in metropolitan city: a case study
In recent decades, heavy metals (HMs) have emerged as a global health concern. Unfortunately, in Pakistan, there is a general lack of awareness regarding the potential health risks associated with HMs pollution among automobile workers. Herein, we investigated the concentration of heavy metals such as lead (Pb), cadmium (Cd), and chromium (Cr) among automobile workers who were occupationally exposed in Mingora City, Khyber Pakhtunkhwa, Pakistan. Three different automobile groups, i.e., battery recyclers, spray painters, and mechanics were studied in detail. A total of 40 blood samples were collected from automobile workers groups while 10 blood samples were collected as control individuals from different locations in the study area. We investigated heavy metals concentration with a standard method using an atomic absorption spectrometer AAS (PerkinElmer Analyst 700, United States). Based on our findings, the battery recycling group displayed the most elevated Pb levels (5.45 ± 2.11 μg/dL), exceeding those of both the spray painters’ group (5.12 ± 1.98 μg/dL) and the mechanics’ group (3.79 ± 2.21 μg/dL). This can be attributed to their higher exposure to Pb pollution resulting from the deterioration, dismantling, grinding, or crushing of old batteries. In the context of chromium (Cr) exposure, a similar trend was observed among the battery recycling group, as well as the spray painters and mechanics groups. However, in the case of cadmium (Cd), the mechanics’ group exhibited the highest level of exposure (4.45 ± 0.65 μg/dL), surpassing the battery recycling group (1.17 ± 0.45 μg/dL) and the spray painters’ group (1.35 ± 0.69 μg/dL), which was attributed to their greater exposure to welding fumes and other activities in their workplace. We believe that our findings will encourage regulatory measures to improve the health of automobile workers. However, further work is needed to determine various health-related issues associated with heavy metal exposure among automobile workers.
- 2 May 2023
- Published by Taylor & Francis
- p. 124-128
Drug Eruptions
The adverse cutaneous drug reactions range from localized reactions like fixed drug eruption to generalized and severe life-threatening reactions like Steven–Johnson (SJS) syndrome and toxic epidermal necrolysis (TEN). The vulvar, oral and conjunctival mucosa are well-recognized sites for drug reactions. A detailed drug history is essential in patients with vulvar erosions and ulcers. This chapter gives information about clinical features, management and prevention of sequelae in patients with vulvar involvement due to drug react ions.
- 2 May 2023
- Published by Taylor & Francis
- p. 124-128
Drug Eruptions
The adverse cutaneous drug reactions range from localized reactions like fixed drug eruption to generalized and severe life-threatening reactions like Steven–Johnson (SJS) syndrome and toxic epidermal necrolysis (TEN). The vulvar, oral and conjunctival mucosa are well-recognized sites for drug reactions. A detailed drug history is essential in patients with vulvar erosions and ulcers. This chapter gives information about clinical features, management and prevention of sequelae in patients with vulvar involvement due to drug react ions.
- Open Access
- 3 October 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (10) , 2405
Deep Learning Assisted Automated Assessment of Thalassaemia from Haemoglobin Electrophoresis Images
Haemoglobin (Hb) electrophoresis is a method of blood testing used to detect thalassaemia. However, the interpretation of the result of the electrophoresis test itself is a complex task. Expert haematologists, specifically in developing countries, are relatively few in number and are usually overburdened. To assist them with their workload, in this paper we present a novel method for the automated assessment of thalassaemia using Hb electrophoresis images. Moreover, in this study we compile a large Hb electrophoresis image dataset, consisting of 103 strips containing 524 electrophoresis images with a clear consensus on the quality of electrophoresis obtained from 824 subjects. The proposed methodology is split into two parts: (1) single-patient electrophoresis image segmentation by means of the lane extraction technique, and (2) binary classification (normal or abnormal) of the electrophoresis images using state-of-the-art deep convolutional neural networks (CNNs) and using the concept of transfer learning. Image processing techniques including filtering and morphological operations are applied for object detection and lane extraction to automatically separate the lanes and classify them using CNN models. Seven different CNN models (ResNet18, ResNet50, ResNet101, InceptionV3, DenseNet201, SqueezeNet and MobileNetV2) were investigated in this study. InceptionV3 outperformed the other CNNs in detecting thalassaemia using Hb electrophoresis images. The accuracy, precision, recall, f1-score, and specificity in the detection of thalassaemia obtained with the InceptionV3 model were 95.8%, 95.84%, 95.8%, 95.8% and 95.8%, respectively. MobileNetV2 demonstrated an accuracy, precision, recall, f1-score, and specificity of 95.72%, 95.73%, 95.72%, 95.7% and 95.72% respectively. Its performance was comparable with the best performing model, InceptionV3. Since it is a very shallow network, MobileNetV2 also provides the least latency in processing a single-patient image and it can be suitably used for mobile applications. The proposed approach, which has shown very high classification accuracy, will assist in the rapid and robust detection of thalassaemia using Hb electrophoresis images.
- 3 October 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (10) , 2405
Open AccessDeep Learning Assisted Automated Assessment of Thalassaemia from Haemoglobin Electrophoresis Images
Haemoglobin (Hb) electrophoresis is a method of blood testing used to detect thalassaemia. However, the interpretation of the result of the electrophoresis test itself is a complex task. Expert haematologists, specifically in developing countries, are relatively few in number and are usually overburdened. To assist them with their workload, in this paper we present a novel method for the automated assessment of thalassaemia using Hb electrophoresis images. Moreover, in this study we compile a large Hb electrophoresis image dataset, consisting of 103 strips containing 524 electrophoresis images with a clear consensus on the quality of electrophoresis obtained from 824 subjects. The proposed methodology is split into two parts: (1) single-patient electrophoresis image segmentation by means of the lane extraction technique, and (2) binary classification (normal or abnormal) of the electrophoresis images using state-of-the-art deep convolutional neural networks (CNNs) and using the concept of transfer learning. Image processing techniques including filtering and morphological operations are applied for object detection and lane extraction to automatically separate the lanes and classify them using CNN models. Seven different CNN models (ResNet18, ResNet50, ResNet101, InceptionV3, DenseNet201, SqueezeNet and MobileNetV2) were investigated in this study. InceptionV3 outperformed the other CNNs in detecting thalassaemia using Hb electrophoresis images. The accuracy, precision, recall, f1-score, and specificity in the detection of thalassaemia obtained with the InceptionV3 model were 95.8%, 95.84%, 95.8%, 95.8% and 95.8%, respectively. MobileNetV2 demonstrated an accuracy, precision, recall, f1-score, and specificity of 95.72%, 95.73%, 95.72%, 95.7% and 95.72% respectively. Its performance was comparable with the best performing model, InceptionV3. Since it is a very shallow network, MobileNetV2 also provides the least latency in processing a single-patient image and it can be suitably used for mobile applications. The proposed approach, which has shown very high classification accuracy, will assist in the rapid and robust detection of thalassaemia using Hb electrophoresis images.
- Open Access
- 19 May 2022
- Published by Wiley in Security and Communication Networks
- Vol. 2022, 1-15
Op2Vec: An Opcode Embedding Technique and Dataset Design for End-to-End Detection of Android Malware
Android is one of the leading operating systems for smartphones in terms of market share and usage. Unfortunately, it is also an appealing target for attackers to compromise its security through malicious applications. To tackle this issue, domain experts and researchers are trying different techniques to stop such attacks. All the attempts of securing the Android platform are somewhat successful. However, existing detection techniques have severe shortcomings, including the cumbersome process of feature engineering. Designing representative features require expert domain knowledge. There is a need for minimizing human experts intervention by circumventing handcrafted feature engineering. Deep learning could be exploited by extracting deep features automatically. Previous work has shown that operational codes (opcodes) of executables provide key information to be used with deep learning models for the detection process of malicious applications. The only challenge is to feed opcodes information to deep learning models. Existing techniques use one-hot encoding to tackle the challenge. However, the one-hot encoding scheme has severe limitations. In this paper, we introduce (1) a novel technique for opcodes embedding, which we name Op2Vec, and (2) based on the learned Op2Vec, we have developed a dataset for end-to-end detection of Android malware. Introducing the end-to-end Android malware detection technique avoids expert-intensive handcrafted feature extraction and ensures automation. Some of the recent deep learning-based techniques showed significantly improved results when tested with the proposed approach and achieved an average detection accuracy of 97.47, precision of 0.976, and F1 score of 0.979.
- 19 May 2022
- Published by Wiley in Security and Communication Networks
- Vol. 2022, 1-15
Open AccessOp2Vec: An Opcode Embedding Technique and Dataset Design for End-to-End Detection of Android Malware
Android is one of the leading operating systems for smartphones in terms of market share and usage. Unfortunately, it is also an appealing target for attackers to compromise its security through malicious applications. To tackle this issue, domain experts and researchers are trying different techniques to stop such attacks. All the attempts of securing the Android platform are somewhat successful. However, existing detection techniques have severe shortcomings, including the cumbersome process of feature engineering. Designing representative features require expert domain knowledge. There is a need for minimizing human experts intervention by circumventing handcrafted feature engineering. Deep learning could be exploited by extracting deep features automatically. Previous work has shown that operational codes (opcodes) of executables provide key information to be used with deep learning models for the detection process of malicious applications. The only challenge is to feed opcodes information to deep learning models. Existing techniques use one-hot encoding to tackle the challenge. However, the one-hot encoding scheme has severe limitations. In this paper, we introduce (1) a novel technique for opcodes embedding, which we name Op2Vec, and (2) based on the learned Op2Vec, we have developed a dataset for end-to-end detection of Android malware. Introducing the end-to-end Android malware detection technique avoids expert-intensive handcrafted feature extraction and ensures automation. Some of the recent deep learning-based techniques showed significantly improved results when tested with the proposed approach and achieved an average detection accuracy of 97.47, precision of 0.976, and F1 score of 0.979.
- Open Access
Op2Vec: An Opcode Embedding Technique and Dataset Design for End-to-End Detection of Android Malware
Android is one of the leading operating systems for smart phones in terms of market share and usage. Unfortunately, it is also an appealing target for attackers to compromise its security through malicious applications. To tackle this issue, domain experts and researchers are trying different techniques to stop such attacks. All the attempts of securing Android platform are somewhat successful. However, existing detection techniques have severe shortcomings, including the cumbersome process of feature engineering. Designing representative features require expert domain knowledge. There is a need for minimizing human experts' intervention by circumventing handcrafted feature engineering. Deep learning could be exploited by extracting deep features automatically. Previous work has shown that operational codes (opcodes) of executables provide key information to be used with deep learning models for detection process of malicious applications. The only challenge is to feed opcodes information to deep learning models. Existing techniques use one-hot encoding to tackle the challenge. However, the one-hot encoding scheme has severe limitations. In this paper, we introduce; (1) a novel technique for opcodes embedding, which we name Op2Vec, (2) based on the learned Op2Vec we have developed a dataset for end-to-end detection of android malware. Introducing the end-to-end Android malware detection technique avoids expert-intensive handcrafted features extraction, and ensures automation. Some of the recent deep learning-based techniques showed significantly improved results when tested with the proposed approach and achieved an average detection accuracy of 97.47%, precision of 0.976 and F1 score of 0.979.
Open AccessOp2Vec: An Opcode Embedding Technique and Dataset Design for End-to-End Detection of Android Malware
Android is one of the leading operating systems for smart phones in terms of market share and usage. Unfortunately, it is also an appealing target for attackers to compromise its security through malicious applications. To tackle this issue, domain experts and researchers are trying different techniques to stop such attacks. All the attempts of securing Android platform are somewhat successful. However, existing detection techniques have severe shortcomings, including the cumbersome process of feature engineering. Designing representative features require expert domain knowledge. There is a need for minimizing human experts' intervention by circumventing handcrafted feature engineering. Deep learning could be exploited by extracting deep features automatically. Previous work has shown that operational codes (opcodes) of executables provide key information to be used with deep learning models for detection process of malicious applications. The only challenge is to feed opcodes information to deep learning models. Existing techniques use one-hot encoding to tackle the challenge. However, the one-hot encoding scheme has severe limitations. In this paper, we introduce; (1) a novel technique for opcodes embedding, which we name Op2Vec, (2) based on the learned Op2Vec we have developed a dataset for end-to-end detection of android malware. Introducing the end-to-end Android malware detection technique avoids expert-intensive handcrafted features extraction, and ensures automation. Some of the recent deep learning-based techniques showed significantly improved results when tested with the proposed approach and achieved an average detection accuracy of 97.47%, precision of 0.976 and F1 score of 0.979.
- 1 September 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (9) , 095003
Deep learning based classification of unsegmented phonocardiogram spectrograms leveraging transfer learning
Objective. Cardiovascular diseases (CVDs) are a main cause of deaths all over the world. This research focuses on computer-aided analysis of phonocardiogram (PCG) signals based on deep learning that can enable improved and timely detection of heart abnormalities. The two widely used publicly available PCG datasets are from the PhysioNet/CinC (2016) and PASCAL (2011) challenges. The datasets are significantly different in terms of the tools used for data acquisition, clinical protocols, digital storages and signal qualities, making it challenging to process and analyze. Approach. In this work, we have used short-time Fourier transform-based spectrograms to learn the representative patterns of the normal and abnormal PCG signals. Spectrograms generated from both the datasets are utilized to perform four different studies: (i) train, validate and test different variants of convolutional neural network (CNN) models with PhysioNet dataset, (ii) train, validate and test the best performing CNN structure on the PASCAL dataset, as well as (iii) on the combined PhysioNet-PASCAL dataset and (iv) finally, the transfer learning technique is employed to train the best performing pre-trained network from the first study with PASCAL dataset. Main results. The first study achieves an accuracy, sensitivity, specificity, precision and F1 scores of 95.75%, 96.3%, 94.1%, 97.52%, and 96.93%, respectively, while the second study shows accuracy, sensitivity, specificity, precision and F1 scores of 75.25%, 74.2%, 76.4%, 76.73%, and 75.42%, respectively. The third study shows accuracy, sensitivity, specificity, precision and F1 scores of 92.7%, 94.98%, 89.95%, 95.3% and 94.6%, respectively. Finally, the fourth study shows a precision of 96.98% on the noisy PASCAL dataset with transfer learning approach. Significance. The proposed approach employs a less complex and relatively light custom CNN model that outperforms most of the recent competing studies by achieving comparatively high classification accuracy and precision, making it suitable for screening CVDs using PCG signals.
- 1 September 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (9) , 095003
Deep learning based classification of unsegmented phonocardiogram spectrograms leveraging transfer learning
Objective. Cardiovascular diseases (CVDs) are a main cause of deaths all over the world. This research focuses on computer-aided analysis of phonocardiogram (PCG) signals based on deep learning that can enable improved and timely detection of heart abnormalities. The two widely used publicly available PCG datasets are from the PhysioNet/CinC (2016) and PASCAL (2011) challenges. The datasets are significantly different in terms of the tools used for data acquisition, clinical protocols, digital storages and signal qualities, making it challenging to process and analyze. Approach. In this work, we have used short-time Fourier transform-based spectrograms to learn the representative patterns of the normal and abnormal PCG signals. Spectrograms generated from both the datasets are utilized to perform four different studies: (i) train, validate and test different variants of convolutional neural network (CNN) models with PhysioNet dataset, (ii) train, validate and test the best performing CNN structure on the PASCAL dataset, as well as (iii) on the combined PhysioNet-PASCAL dataset and (iv) finally, the transfer learning technique is employed to train the best performing pre-trained network from the first study with PASCAL dataset. Main results. The first study achieves an accuracy, sensitivity, specificity, precision and F1 scores of 95.75%, 96.3%, 94.1%, 97.52%, and 96.93%, respectively, while the second study shows accuracy, sensitivity, specificity, precision and F1 scores of 75.25%, 74.2%, 76.4%, 76.73%, and 75.42%, respectively. The third study shows accuracy, sensitivity, specificity, precision and F1 scores of 92.7%, 94.98%, 89.95%, 95.3% and 94.6%, respectively. Finally, the fourth study shows a precision of 96.98% on the noisy PASCAL dataset with transfer learning approach. Significance. The proposed approach employs a less complex and relatively light custom CNN model that outperforms most of the recent competing studies by achieving comparatively high classification accuracy and precision, making it suitable for screening CVDs using PCG signals.
- Open Access
- 5 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 187-192
Evaluation of Preprocessing Techniques for U-Net Based Automated Liver Segmentation
To extract liver from medical images is a challenging task due to similar intensity values of liver with adjacent organs, various contrast levels, various noise associated with medical images and irregular shape of liver. To address these issues, it is important to preprocess the medical images, i.e., computerized tomography (CT) and magnetic resonance imaging (MRI) data prior to liver analysis and quantification. This paper investigates the impact of permutation of various preprocessing techniques for CT images, on the automated liver segmentation using deep learning, i.e., U-Net architecture. The study focuses on Hounsfield Unit (HU) windowing, contrast limited adaptive histogram equalization (CLAHE), z-score normalization, median filtering and Block-Matching and 3D (BM3D) filtering. The segmented results show that combination of three techniques; HU-windowing, median filtering and z-score normalization achieve optimal performance with Dice coefficient of 96.93%, 90.77% and 90.84% for training, validation and testing respectively.
- 5 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 187-192
Open AccessEvaluation of Preprocessing Techniques for U-Net Based Automated Liver Segmentation
To extract liver from medical images is a challenging task due to similar intensity values of liver with adjacent organs, various contrast levels, various noise associated with medical images and irregular shape of liver. To address these issues, it is important to preprocess the medical images, i.e., computerized tomography (CT) and magnetic resonance imaging (MRI) data prior to liver analysis and quantification. This paper investigates the impact of permutation of various preprocessing techniques for CT images, on the automated liver segmentation using deep learning, i.e., U-Net architecture. The study focuses on Hounsfield Unit (HU) windowing, contrast limited adaptive histogram equalization (CLAHE), z-score normalization, median filtering and Block-Matching and 3D (BM3D) filtering. The segmented results show that combination of three techniques; HU-windowing, median filtering and z-score normalization achieve optimal performance with Dice coefficient of 96.93%, 90.77% and 90.84% for training, validation and testing respectively.