Pedro Razquin
Research Subjects
Pedro Razquin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Luis Mata
Zeulab S.L. , Calle Bari 25 Dpdo , 50197 Zaragoza
9 shared publications - Vanesa Carrascón
Zeulab S.L. , Calle Bari 25 Dpdo , 50197 Zaragoza
3 shared publications - María Jesús Serrano
Instituto Agroalimentario de Aragón-IA2, Universidad de Zaragoza-CITA, 50013 Zaragoza, Spain
2 shared publications - Patricia Galán-Malo
Universidad de Zaragoza
2 shared publications - Rafael Pagán
Departamento de Producción Animal y Ciencia de los Alimentos, Facultad de Veterinaria, Instituto Agroalimentario de Aragón-IA2, Universidad de Zaragoza-CITA, Calle Miguel Servet 177, 50013 Zaragoza, Spain
2 shared publications - Raúl Alonso
Zeulab S.L. , Calle Bari 25 Dpdo , 50197 Zaragoza
2 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 109 (11) , 11308-11319
Qualitative and quantitative analysis of mixed-milk cheeses by targeted proteomics
This work presents a novel analytical method to determine the proportions of cow, sheep, and goat milk in mixed-milk cheeses, common in Spain and Europe. First, an in-depth shotgun proteomic analysis to define the protein composition of milk and cheese from each species was performed. Thereafter, a targeted parallel reaction monitoring method was developed using a panel of 3 species-specific tryptic peptides and one peptide common to all species. This method was optimized using reference cheeses of known composition, and it was validated according to internationally recognized guidelines. The method demonstrated linearity in the range of = 0% to 100% with detection limits less than 1% for all 3 species and showed good repeatability (CV = 8%), reproducibility (CV = 10%), and accuracy (99.6%), enabling both qualitative and quantitative analysis. Finally, the method was applied to commercial cheeses with diverse compositions and ripening times. The measurements were unaffected by either the ripening or production process, demonstrating the robustness of the analysis even with potential interferents. These results demonstrate the great potential of the method for quality control purposes and its applicability to real-world commercial samples.
- 1 November 2026
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 109 (11) , 11308-11319
Open AccessQualitative and quantitative analysis of mixed-milk cheeses by targeted proteomics
This work presents a novel analytical method to determine the proportions of cow, sheep, and goat milk in mixed-milk cheeses, common in Spain and Europe. First, an in-depth shotgun proteomic analysis to define the protein composition of milk and cheese from each species was performed. Thereafter, a targeted parallel reaction monitoring method was developed using a panel of 3 species-specific tryptic peptides and one peptide common to all species. This method was optimized using reference cheeses of known composition, and it was validated according to internationally recognized guidelines. The method demonstrated linearity in the range of = 0% to 100% with detection limits less than 1% for all 3 species and showed good repeatability (CV = 8%), reproducibility (CV = 10%), and accuracy (99.6%), enabling both qualitative and quantitative analysis. Finally, the method was applied to commercial cheeses with diverse compositions and ripening times. The measurements were unaffected by either the ripening or production process, demonstrating the robustness of the analysis even with potential interferents. These results demonstrate the great potential of the method for quality control purposes and its applicability to real-world commercial samples.
- 22 October 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (1) , 139-150
Validation of the Microlab Listeria monocytogenes for Detection of Listeria monocytogenes in Select Foods: AOAC Performance Tested Method SM 062502
Background: Microlab Listeria monocytogenes is an all-in-one detection method that integrates, in a single disposable device, all elements to perform the analysis; a ready-to-use enrichment broth, a lateral flow immunochromatographic test, and a chemical agent for bacterial inactivation. It can be easily used on-site in food processing facilities. Objective: This report presents the validation data supporting AOAC Performance Tested MethodSM 062502 certification of the Microlab Listeria monocytogenes test for cheddar cheese, ice cream, smoked salmon, deli ham, and deli turkey. Environmental surfaces are not included in the validation study. Methods: The Microlab Listeria monocytogenes was compared to the ISO Standard 11290:2017 method for the detection of L. monocytogenes in select foods. The comparison study used 30 unpaired test portions for all matrixes. Inclusivity and exclusivity study evaluated 50 L. monocytogenes and 36 non-L. monocytogenes isolates. The product consistency/stability study evaluated three separate lots in an accelerated shelf-life design. Robustness was evaluated by modifying three operational parameters. Results: Inclusivity and exclusivity testing showed that the Microlab Listeria monocytogenes method detects L. monocytogenes strains while excluding the non-Listeria monocytogenes strains. L. innocua or L. marthii may yield positive results in foods at levels above 87 CFU/25 g. In the matrix studies, no statistically significant differences were observed between the candidate and reference methods. Minor procedural variations (enrichment time, time to read results, and enrichment temperature) did not affect assay performance. No significant differences were found between recently manufactured lots and those near expiration. Conclusions: The reported data confirm that Microlab Listeria monocytogenes reliably detects L. monocytogenes in the tested food matrixes. The method is based on presence/absence detection, with a limit of detection of 1 CFU per test portion. Highlights: Microlab Listeria monocytogenes detects L. monocytogenes in foods, integrating enrichment, detection, and inactivation in one compact device.
- 22 October 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (1) , 139-150
Validation of the Microlab Listeria monocytogenes for Detection of Listeria monocytogenes in Select Foods: AOAC Performance Tested Method SM 062502
Background: Microlab Listeria monocytogenes is an all-in-one detection method that integrates, in a single disposable device, all elements to perform the analysis; a ready-to-use enrichment broth, a lateral flow immunochromatographic test, and a chemical agent for bacterial inactivation. It can be easily used on-site in food processing facilities. Objective: This report presents the validation data supporting AOAC Performance Tested MethodSM 062502 certification of the Microlab Listeria monocytogenes test for cheddar cheese, ice cream, smoked salmon, deli ham, and deli turkey. Environmental surfaces are not included in the validation study. Methods: The Microlab Listeria monocytogenes was compared to the ISO Standard 11290:2017 method for the detection of L. monocytogenes in select foods. The comparison study used 30 unpaired test portions for all matrixes. Inclusivity and exclusivity study evaluated 50 L. monocytogenes and 36 non-L. monocytogenes isolates. The product consistency/stability study evaluated three separate lots in an accelerated shelf-life design. Robustness was evaluated by modifying three operational parameters. Results: Inclusivity and exclusivity testing showed that the Microlab Listeria monocytogenes method detects L. monocytogenes strains while excluding the non-Listeria monocytogenes strains. L. innocua or L. marthii may yield positive results in foods at levels above 87 CFU/25 g. In the matrix studies, no statistically significant differences were observed between the candidate and reference methods. Minor procedural variations (enrichment time, time to read results, and enrichment temperature) did not affect assay performance. No significant differences were found between recently manufactured lots and those near expiration. Conclusions: The reported data confirm that Microlab Listeria monocytogenes reliably detects L. monocytogenes in the tested food matrixes. The method is based on presence/absence detection, with a limit of detection of 1 CFU per test portion. Highlights: Microlab Listeria monocytogenes detects L. monocytogenes in foods, integrating enrichment, detection, and inactivation in one compact device.
- 21 August 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (6) , 979-989
Validation of the Microlab Salmonella for Detection of Salmonella O Group A-E in Selected Foods: AOAC Performance Tested MethodSM 052401
Microlab Salmonella is an all-in-one solution for detection of Salmonella O Groups A-E that integrates, in a single disposable device, all elements to perform the analysis; a ready-to-use enrichment broth, a lateral flow immunochromatography test and a chemical agent for bacterial inactivation. Microlab Salmonella can be easily used on-site and does not require specific laboratory equipment or technical skills. The device is sealed during the analysis avoiding risks of contamination and is therefore safe to use in food production environments. This report details the method validation study for raw ground beef, raw turkey (thermal processed, marinated), fresh cheese, deli ham and pasteurized liquid egg. Matrix studies and inclusivity/exclusivity, product consistency/stability, and robustness testing were conducted to assess the method’s performance. Inclusivity/exclusivity testing showed that the Microlab Salmonella method was able to detect Salmonella O Group A-E isolates while excluding the non-Salmonella strains. In the matrix studies the differences between the candidate and reference methods were not statistically significant. Minor variations in test parameters (enrichment time, time to read results, and enrichment temperature) did not affect the performance of the Microlab assay. There were no statistically significant differences between recently manufactured lots and those that were halfway through their expiration period or between those that were close to expiring. The reported data confirms that Microlab Salmonella is reliable for detecting Salmonella in raw ground beef, raw turkey (thermal processed, marinated), fresh cheese, pasteurized liquid egg and deli ham. Microlab Salmonella is validated to detect Salmonella in select food matrixes. Microlab Salmonella integrates the steps of enrichment, detection, and inactivation in a single device.
- 21 August 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (6) , 979-989
Validation of the Microlab Salmonella for Detection of Salmonella O Group A-E in Selected Foods: AOAC Performance Tested MethodSM 052401
Microlab Salmonella is an all-in-one solution for detection of Salmonella O Groups A-E that integrates, in a single disposable device, all elements to perform the analysis; a ready-to-use enrichment broth, a lateral flow immunochromatography test and a chemical agent for bacterial inactivation. Microlab Salmonella can be easily used on-site and does not require specific laboratory equipment or technical skills. The device is sealed during the analysis avoiding risks of contamination and is therefore safe to use in food production environments. This report details the method validation study for raw ground beef, raw turkey (thermal processed, marinated), fresh cheese, deli ham and pasteurized liquid egg. Matrix studies and inclusivity/exclusivity, product consistency/stability, and robustness testing were conducted to assess the method’s performance. Inclusivity/exclusivity testing showed that the Microlab Salmonella method was able to detect Salmonella O Group A-E isolates while excluding the non-Salmonella strains. In the matrix studies the differences between the candidate and reference methods were not statistically significant. Minor variations in test parameters (enrichment time, time to read results, and enrichment temperature) did not affect the performance of the Microlab assay. There were no statistically significant differences between recently manufactured lots and those that were halfway through their expiration period or between those that were close to expiring. The reported data confirms that Microlab Salmonella is reliable for detecting Salmonella in raw ground beef, raw turkey (thermal processed, marinated), fresh cheese, pasteurized liquid egg and deli ham. Microlab Salmonella is validated to detect Salmonella in select food matrixes. Microlab Salmonella integrates the steps of enrichment, detection, and inactivation in a single device.
- Open Access
- 19 September 2023
- Published by Elsevier in Food Control
- Vol. 156
Development and validation of a rapid lateral flow test for the detection of fluoroquinolones in meat and blood
- 19 September 2023
- Published by Elsevier in Food Control
- Vol. 156
Open AccessDevelopment and validation of a rapid lateral flow test for the detection of fluoroquinolones in meat and blood
- Open Access
Optimization and Validation of a New Microbial Inhibition Test for the Detection of Antimicrobial Residues in Living Animals Intended for Human Consumption
Even though antibiotics are necessary in livestock production, they can be harmful not only due to their toxicity, but also in view of their contribution to the emergence of antimicrobial resistance. Screening tests based on microbial growth inhibition appeared to be useful tools to prevent its entry into the food chain. They have nevertheless been traditionally carried out post mortem, leading to great economical loss and harm to the environment in case a positive sample is found. Hence, the objective was to evaluate the use of a screening test as an ante mortem alternative for the detection of antibiotic residues in meat: thus, Explorer®-Blood test was optimized and validated. After adapting the procedure for matrix preparation, the assay parameters were assessed from 344 antibiotic-free blood serum samples. Limits of Detection (LoDs) were defined by spiking blood serum with several of the most common antimicrobials used in veterinary practice. LoDs were similar to those obtained for meat and were at or below the maximum residue limits set by EU legislation for muscle. Analyses of in vivo injected samples, previously characterized by LC-MS/MS, demonstrated the method’s accuracy and proved that Explorer®-Blood can be considered a suitable alternative to conventional post mortem screening methods.
Open AccessOptimization and Validation of a New Microbial Inhibition Test for the Detection of Antimicrobial Residues in Living Animals Intended for Human Consumption
Even though antibiotics are necessary in livestock production, they can be harmful not only due to their toxicity, but also in view of their contribution to the emergence of antimicrobial resistance. Screening tests based on microbial growth inhibition appeared to be useful tools to prevent its entry into the food chain. They have nevertheless been traditionally carried out post mortem, leading to great economical loss and harm to the environment in case a positive sample is found. Hence, the objective was to evaluate the use of a screening test as an ante mortem alternative for the detection of antibiotic residues in meat: thus, Explorer®-Blood test was optimized and validated. After adapting the procedure for matrix preparation, the assay parameters were assessed from 344 antibiotic-free blood serum samples. Limits of Detection (LoDs) were defined by spiking blood serum with several of the most common antimicrobials used in veterinary practice. LoDs were similar to those obtained for meat and were at or below the maximum residue limits set by EU legislation for muscle. Analyses of in vivo injected samples, previously characterized by LC-MS/MS, demonstrated the method’s accuracy and proved that Explorer®-Blood can be considered a suitable alternative to conventional post mortem screening methods.
- 28 April 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (5) , 1289-1297
Validation of the Eclipse Farm 4G & COMET for Detection of Antibiotics in Raw Bovine Milk: AOAC Performance Tested MethodSM 022101
The Eclipse Farm 4G test coupled to the COMET device allows for automatic and easy screening of a broad range of antimicrobials in raw bovine milk. All results obtained with this system are available in real-time through a smartphone application (App) and in the Test4all cloud platform. The objective of this study was to validate Eclipse Farm 4G & COMET for the screening of antimicrobials in raw bovine milk according to AOAC Performance Tested MethodSM procedures. The test is based on the inhibition of microbial growth of Geobacillus stearothermophilus in the presence of antimicrobials. When sample tubes are incubated in the absence of antibiotics, spores germinate and cells grow, changing the medium color from purple to yellow (negative result). The presence of antimicrobials in the milk sample hinders bacterial growth, preventing the tubes from changing color from purple to yellow (positive result). The COMET device automatically integrates all assay steps (incubation, time control, and results interpretation) and communications between the device, smartphone, and cloud. LODs and detection capabilities were confirmed to be at or below the European Union (EU) maximum residue limit (MRL) for most of the evaluated molecules representing the main families of antimicrobials (penicillins, cephalosporins, tetracyclines, sulfonamides, macrolides, and aminoglycosides). False-positive rates and the effect of potentially interfering substances showed sufficient selectivity/specificity. The Eclipse Farm 4G & COMET system was shown to be robust, consistent, and stable during shelf life. The Eclipse Farm 4G & COMET system has been shown to be suitable for screening antibiotics in raw bovine milk. The assay is an automatic and easy system for the detection of a broad range of antibiotics in raw bovine milk consistent with EU MRLs and can provide results any time and anywhere through a smartphone App and a cloud platform.
- 28 April 2021
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 104 (5) , 1289-1297
Validation of the Eclipse Farm 4G & COMET for Detection of Antibiotics in Raw Bovine Milk: AOAC Performance Tested MethodSM 022101
The Eclipse Farm 4G test coupled to the COMET device allows for automatic and easy screening of a broad range of antimicrobials in raw bovine milk. All results obtained with this system are available in real-time through a smartphone application (App) and in the Test4all cloud platform. The objective of this study was to validate Eclipse Farm 4G & COMET for the screening of antimicrobials in raw bovine milk according to AOAC Performance Tested MethodSM procedures. The test is based on the inhibition of microbial growth of Geobacillus stearothermophilus in the presence of antimicrobials. When sample tubes are incubated in the absence of antibiotics, spores germinate and cells grow, changing the medium color from purple to yellow (negative result). The presence of antimicrobials in the milk sample hinders bacterial growth, preventing the tubes from changing color from purple to yellow (positive result). The COMET device automatically integrates all assay steps (incubation, time control, and results interpretation) and communications between the device, smartphone, and cloud. LODs and detection capabilities were confirmed to be at or below the European Union (EU) maximum residue limit (MRL) for most of the evaluated molecules representing the main families of antimicrobials (penicillins, cephalosporins, tetracyclines, sulfonamides, macrolides, and aminoglycosides). False-positive rates and the effect of potentially interfering substances showed sufficient selectivity/specificity. The Eclipse Farm 4G & COMET system was shown to be robust, consistent, and stable during shelf life. The Eclipse Farm 4G & COMET system has been shown to be suitable for screening antibiotics in raw bovine milk. The assay is an automatic and easy system for the detection of a broad range of antibiotics in raw bovine milk consistent with EU MRLs and can provide results any time and anywhere through a smartphone App and a cloud platform.
- 1 April 2017
- Published by Elsevier in Food Control
- Vol. 74, 45-53
Detection of egg and milk residues on working surfaces by ELISA and lateral flow immunoassay tests
- 1 April 2017
- Published by Elsevier in Food Control
- Vol. 74, 45-53
Detection of egg and milk residues on working surfaces by ELISA and lateral flow immunoassay tests
- 1 June 2014
- Published by Elsevier in Small Ruminant Research
- Vol. 119 (1-3) , 156-160
Determination of IgG levels in bulk ewe's milk
- 1 June 2014
- Published by Elsevier in Small Ruminant Research
- Vol. 119 (1-3) , 156-160
Determination of IgG levels in bulk ewe's milk
- Open Access
Single Laboratory Validation of A Ready-to-Use Phosphatase Inhibition Assay for Detection of Okadaic Acid Toxins
A phosphatase inhibition assay for detection of okadaic acid (OA) toxins in shellfish, OkaTest, was single laboratory validated according to international recognized guidelines (AOAC, EURACHEM). Special emphasis was placed on the ruggedness of the method and stability of the components. All reagents were stable for more than 6 months and the method was highly robust under normal laboratory conditions. The limit of detection and quantification were 44 and 56 µg/kg, respectively; both below the European legal limit of 160 µg/kg. The repeatability was evaluated with 2 naturally contaminated samples. The relative standard deviation (RSD) calculated was 1.4% at a level of 276 µg/kg and 3.9% at 124 µg/kg. Intermediate precision was estimated by testing 10 different samples (mussel and scallop) on three different days and ranged between 2.4 and 9.5%. The IC50 values of the phosphatase used in this assay were determined for OA (1.2 nM), DTX-1 (1.6 nM) and DTX-2 (1.2 nM). The accuracy of the method was estimated by recovery testing for OA (mussel, 78–101%; king scallop, 98–114%), DTX-1 (king scallop, 79–102%) and DTX-2 (king scallop, 93%). Finally, the method was qualitatively compared to the mouse bioassay and LC-MS/MS.
Open AccessSingle Laboratory Validation of A Ready-to-Use Phosphatase Inhibition Assay for Detection of Okadaic Acid Toxins
A phosphatase inhibition assay for detection of okadaic acid (OA) toxins in shellfish, OkaTest, was single laboratory validated according to international recognized guidelines (AOAC, EURACHEM). Special emphasis was placed on the ruggedness of the method and stability of the components. All reagents were stable for more than 6 months and the method was highly robust under normal laboratory conditions. The limit of detection and quantification were 44 and 56 µg/kg, respectively; both below the European legal limit of 160 µg/kg. The repeatability was evaluated with 2 naturally contaminated samples. The relative standard deviation (RSD) calculated was 1.4% at a level of 276 µg/kg and 3.9% at 124 µg/kg. Intermediate precision was estimated by testing 10 different samples (mussel and scallop) on three different days and ranged between 2.4 and 9.5%. The IC50 values of the phosphatase used in this assay were determined for OA (1.2 nM), DTX-1 (1.6 nM) and DTX-2 (1.2 nM). The accuracy of the method was estimated by recovery testing for OA (mussel, 78–101%; king scallop, 98–114%), DTX-1 (king scallop, 79–102%) and DTX-2 (king scallop, 93%). Finally, the method was qualitatively compared to the mouse bioassay and LC-MS/MS.