Yueling Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yueling Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jibin Zhao
Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, People’s Republic of China
3 shared publications - Renbo Xia
Shenyang Institute of Automation, Chinese Academy of Sciences
3 shared publications - Shengpeng Fu
Shenyang Institute of Automation, Chinese Academy of Sciences
3 shared publications - Tao Zhang
State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
3 shared publications - Jiajun Wu
College of Engineering, Shantou University, Shantou 515063, China
2 shared publications - Yanyi Sun
Shanghai Academy of Spaceflight Technology, Shanghai, China
2 shared publications
Latest Publications
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
A Spectral-Domain Low-Coherence Method for Measuring Composite Windshield Thickness
To improve the performance and reduce the weight of new-generation transparent windshields in aircraft, composite structures are commonly used. The thickness of each layer in a composite windshield has a significant impact on its optical properties and load-bearing capacity. However, existing thickness measurement methods for transparent windshields either cannot meet the requirements in terms of range and efficiency, or cannot measure the thickness of each layer in a transparent windshield. In this article, a large-range spectral-domain low-coherence measurement method for composite transparent windshield thickness is proposed. Specifically, 2-D dispersion technology is used to significantly increase spectral resolution, thereby achieving an improvement in measurement range. Then, a spectral stitching and wavenumber calibration method based on automatic fringe generation is proposed to achieve the conversion from spectral domain to spatial domain. Finally, a fully fiber-coupled co-path spectral-domain low-coherence measurement system for transparent windshields is constructed. Measurement experiment of standard measurement blocks and composite transparent windshields demonstrate that the proposed method has a range of up to 41 mm, a speed of up to 440 Hz, and an accuracy of up to 0.005 mm, thus validating the effectiveness of the proposed method.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-14
A Spectral-Domain Low-Coherence Method for Measuring Composite Windshield Thickness
To improve the performance and reduce the weight of new-generation transparent windshields in aircraft, composite structures are commonly used. The thickness of each layer in a composite windshield has a significant impact on its optical properties and load-bearing capacity. However, existing thickness measurement methods for transparent windshields either cannot meet the requirements in terms of range and efficiency, or cannot measure the thickness of each layer in a transparent windshield. In this article, a large-range spectral-domain low-coherence measurement method for composite transparent windshield thickness is proposed. Specifically, 2-D dispersion technology is used to significantly increase spectral resolution, thereby achieving an improvement in measurement range. Then, a spectral stitching and wavenumber calibration method based on automatic fringe generation is proposed to achieve the conversion from spectral domain to spatial domain. Finally, a fully fiber-coupled co-path spectral-domain low-coherence measurement system for transparent windshields is constructed. Measurement experiment of standard measurement blocks and composite transparent windshields demonstrate that the proposed method has a range of up to 41 mm, a speed of up to 440 Hz, and an accuracy of up to 0.005 mm, thus validating the effectiveness of the proposed method.
- 4 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Low-Coherence Measurement Methods for Industrial Parts With Large Surface Reflectance Variations
High-precision measurement of sizes and key parameters of industrial parts is crucial to ensure manufacturing accuracy and assembly reliability. Low coherence measurement methods, offer advantages including high-precision, relatively large measuring range, and nondestructive nature. These measurement methods have shown great potential for applications in the field of industrial measurement. However, most of current industrial low coherence measurement methods assume that the surface reflectance of parts is constant or has little variability, resulting in poor adaptability and limited application range of these methods. To address this issue, this paper proposes a low coherence measurement method for measuring key parameters of industrial parts, which can be applied to a variety of parts with significant surface reflectance variations. To be more specific, we first establish an industrial low coherence model that theoretically proves its feasibility in adapting to surfaces with varying reflectance levels. Based on the derived measurement model, we design a simple yet effective optical path that ensures the adaptability of the proposed system to different surfaces. Finally, we build an industrial low coherence system to verify the effectiveness of the proposed method. We measure key parameters of a standard step and various industrial parts with different reflection conditions, and measurement results show that the proposed method achieves an optimal measurement accuracy of 0.0017 mm and a maximum range exceeding 29.0000 mm. The proposed method is also demonstrated to be adaptable to industrial parts with a variety of reflection conditions, including diffuse reflection, specular reflection, and mirror-like reflection.
- 4 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-14
Low-Coherence Measurement Methods for Industrial Parts With Large Surface Reflectance Variations
High-precision measurement of sizes and key parameters of industrial parts is crucial to ensure manufacturing accuracy and assembly reliability. Low coherence measurement methods, offer advantages including high-precision, relatively large measuring range, and nondestructive nature. These measurement methods have shown great potential for applications in the field of industrial measurement. However, most of current industrial low coherence measurement methods assume that the surface reflectance of parts is constant or has little variability, resulting in poor adaptability and limited application range of these methods. To address this issue, this paper proposes a low coherence measurement method for measuring key parameters of industrial parts, which can be applied to a variety of parts with significant surface reflectance variations. To be more specific, we first establish an industrial low coherence model that theoretically proves its feasibility in adapting to surfaces with varying reflectance levels. Based on the derived measurement model, we design a simple yet effective optical path that ensures the adaptability of the proposed system to different surfaces. Finally, we build an industrial low coherence system to verify the effectiveness of the proposed method. We measure key parameters of a standard step and various industrial parts with different reflection conditions, and measurement results show that the proposed method achieves an optimal measurement accuracy of 0.0017 mm and a maximum range exceeding 29.0000 mm. The proposed method is also demonstrated to be adaptable to industrial parts with a variety of reflection conditions, including diffuse reflection, specular reflection, and mirror-like reflection.
- 16 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-15
A Convenient and High-Accuracy Multicamera Calibration Method Based on Imperfect Spherical Objects
Multicamera systems have important applications in industrial online measurement, attracting wide interest due to their encouraging performance. However, how to develop a convenient and high-accuracy multicamera calibration model is a big challenge. Traditional calibration methods based on 2-D objects require the preparation of high-precision and large-scale calibration objects and have poor adaptability to the spatial distribution of cameras. To address these issues, a convenient and accurate multicamera calibration method is proposed based on an imperfect spherical object. Specifically, a special calibration object, i.e., an imperfect sphere with many coded targets is designed for calibrating the multicamera system, where the optical axes of the cameras are different in orientations and converge into the measurement field. Then, a Euclidean reconstruction method is employed to calculate the camera poses and the spatial coordinates of feature points in the local coordinate system after the adaptive grouping of cameras is completed. Moreover, a graph theory-based optimal path transformation algorithm is developed to obtain the camera poses and spatial point coordinates in the global coordinate system (GCS), and a spherical projection optimization algorithm is designed to spheroidize the spatial coordinates of feature points. In the end, the camera poses and the spatial coordinates of feature points in the GCS are optimized by a bundle adjustment algorithm. We build a multicamera system and conduct extensive experiments to demonstrate the superiority of the proposed method.
- 16 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-15
A Convenient and High-Accuracy Multicamera Calibration Method Based on Imperfect Spherical Objects
Multicamera systems have important applications in industrial online measurement, attracting wide interest due to their encouraging performance. However, how to develop a convenient and high-accuracy multicamera calibration model is a big challenge. Traditional calibration methods based on 2-D objects require the preparation of high-precision and large-scale calibration objects and have poor adaptability to the spatial distribution of cameras. To address these issues, a convenient and accurate multicamera calibration method is proposed based on an imperfect spherical object. Specifically, a special calibration object, i.e., an imperfect sphere with many coded targets is designed for calibrating the multicamera system, where the optical axes of the cameras are different in orientations and converge into the measurement field. Then, a Euclidean reconstruction method is employed to calculate the camera poses and the spatial coordinates of feature points in the local coordinate system after the adaptive grouping of cameras is completed. Moreover, a graph theory-based optimal path transformation algorithm is developed to obtain the camera poses and spatial point coordinates in the global coordinate system (GCS), and a spherical projection optimization algorithm is designed to spheroidize the spatial coordinates of feature points. In the end, the camera poses and the spatial coordinates of feature points in the GCS are optimized by a bundle adjustment algorithm. We build a multicamera system and conduct extensive experiments to demonstrate the superiority of the proposed method.