Qing Huan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Qing Huan has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Shixuan Du
Institute of Physics, Chinese Academy of Sciences
8 shared publications - Hong-Jun Gao
Chinese Academy of Sciences
7 shared publications - Rongting Wu
Department of Applied Physics, Yale University, New Haven, USA
7 shared publications - De-Liang Bao
Department of Physics and Astronomy, Vanderbilt University, Nashville, USA
6 shared publications - Linghao Yan
Soochow University
6 shared publications - Yeliang Wang
Beijing Institute of Technology
6 shared publications
Latest Publications
- 13 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455409
Joint state recognition in scanning probe microscopy using spatial-frequency and scan-context learning
Accurate image state recognition is essential for autonomous scanning probe microscopy (SPM), where a single image may simultaneously reflect imaging quality, surface morphology, sample condition and probe-tip state. However, these state attributes are strongly coupled in real SPM acquisition tasks, making conventional single-task or purely spatial-domain classifiers insufficient for reliable joint multi-task recognition. To address this problem, we propose SFDR-ResMamba, a four-task multi-output SPM image classification framework for jointly predicting image quality, image type, sample state, and tip state. The proposed method first constructs a spatial-frequency dual-domain representation (SFDR), which integrates a spatial-enhanced view, a full-band Fourier amplitude view, and a scan-line-direction high-pass reconstruction view to encode local morphology, global periodicity, and scan-related frequency cues. A residual scan-context Mamba encoder is then designed to combine the local inductive bias of residual convolution with row-wise and column-wise Mamba context modeling, enabling efficient representation of raster-scan dependencies and two-dimensional structural continuity. To reduce semantic interference among the four tasks, a task-aware residual gated decoupling module further generates task-specific residual features from multi-level representations. Experiments on the MSPM-10 K dataset demonstrate that SFDR-ResMamba outperforms representative CNN, efficient CNN, Transformer and Mamba-based baselines, achieving a mean accuracy of 92.6% and a mean Macro- F 1 of 90.9%. Ablation studies, conditional performance analysis, and joint correctness evaluation support the contributions of the proposed spatial-frequency representation, scan-context modeling, and task-aware decoupling strategy, while feature visualization provides a qualitative view of the learned tip-state representations.
- 13 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455409
Joint state recognition in scanning probe microscopy using spatial-frequency and scan-context learning
Accurate image state recognition is essential for autonomous scanning probe microscopy (SPM), where a single image may simultaneously reflect imaging quality, surface morphology, sample condition and probe-tip state. However, these state attributes are strongly coupled in real SPM acquisition tasks, making conventional single-task or purely spatial-domain classifiers insufficient for reliable joint multi-task recognition. To address this problem, we propose SFDR-ResMamba, a four-task multi-output SPM image classification framework for jointly predicting image quality, image type, sample state, and tip state. The proposed method first constructs a spatial-frequency dual-domain representation (SFDR), which integrates a spatial-enhanced view, a full-band Fourier amplitude view, and a scan-line-direction high-pass reconstruction view to encode local morphology, global periodicity, and scan-related frequency cues. A residual scan-context Mamba encoder is then designed to combine the local inductive bias of residual convolution with row-wise and column-wise Mamba context modeling, enabling efficient representation of raster-scan dependencies and two-dimensional structural continuity. To reduce semantic interference among the four tasks, a task-aware residual gated decoupling module further generates task-specific residual features from multi-level representations. Experiments on the MSPM-10 K dataset demonstrate that SFDR-ResMamba outperforms representative CNN, efficient CNN, Transformer and Mamba-based baselines, achieving a mean accuracy of 92.6% and a mean Macro- F 1 of 90.9%. Ablation studies, conditional performance analysis, and joint correctness evaluation support the contributions of the proposed spatial-frequency representation, scan-context modeling, and task-aware decoupling strategy, while feature visualization provides a qualitative view of the learned tip-state representations.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
A continuous-operation sub-Kelvin scanning tunneling microscope with high magnetic field via a remote liquefaction cryogen-free scheme
We have developed a cryogen-free ultra-low temperature scanning tunneling microscope (STM) system based on remote liquefaction technology. Integrated with a cryogen-free room-temperature bore 5 T superconducting magnet, the system achieves continuous and stable operation in the sub-Kelvin and high magnetic field regime. A two-stage 4He circulation (∼20 and ∼2 K) precools a continuous-flow STM insert, after which another circulation loop, filled with either 3He or 4He, is liquefied and further cooled by evaporative pumping. The sample stage reaches base temperatures of 420 mK (4He–3He mode) and 894 mK (4He–4He mode). The temperature fluctuations of approximately ±0.1 mK are achieved at 500 mK and 1 K under proportional–integral–derivative control. Characterization, including cooling curves, current noise, thermal drift, atomic-resolution imaging, and variable-temperature/magnetic-field spectroscopy, demonstrates the performance comparable to conventional liquid-4He bath-based STM systems in terms of resolution, stability, and tunability. Furthermore, the system enables a months-long continuous operation across a wide temperature range, featuring straightforward magnet upgradability, direct high-temperature baking capability, and compactness with low installation requirements. This cryogen-free design provides a viable approach for other vibration-sensitive, high-precision experiments requiring long-term continuous operation under extreme conditions.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
A continuous-operation sub-Kelvin scanning tunneling microscope with high magnetic field via a remote liquefaction cryogen-free scheme
We have developed a cryogen-free ultra-low temperature scanning tunneling microscope (STM) system based on remote liquefaction technology. Integrated with a cryogen-free room-temperature bore 5 T superconducting magnet, the system achieves continuous and stable operation in the sub-Kelvin and high magnetic field regime. A two-stage 4He circulation (∼20 and ∼2 K) precools a continuous-flow STM insert, after which another circulation loop, filled with either 3He or 4He, is liquefied and further cooled by evaporative pumping. The sample stage reaches base temperatures of 420 mK (4He–3He mode) and 894 mK (4He–4He mode). The temperature fluctuations of approximately ±0.1 mK are achieved at 500 mK and 1 K under proportional–integral–derivative control. Characterization, including cooling curves, current noise, thermal drift, atomic-resolution imaging, and variable-temperature/magnetic-field spectroscopy, demonstrates the performance comparable to conventional liquid-4He bath-based STM systems in terms of resolution, stability, and tunability. Furthermore, the system enables a months-long continuous operation across a wide temperature range, featuring straightforward magnet upgradability, direct high-temperature baking capability, and compactness with low installation requirements. This cryogen-free design provides a viable approach for other vibration-sensitive, high-precision experiments requiring long-term continuous operation under extreme conditions.
- Open Access
- 1 January 2026
- Published by Biophysical Society of China in Biophysics Reports
- Vol. 12 (4) , 275
Advances in scanning probe microscopy for biological systems
Scanning Probe Microscopy (SPM), as a nanoscale characterization technique, employs a sharp probe to detect local tip-sample interactions through near-field physical phenomena. This approach achieves atomic-resolution surface imaging while enabling concurrent characterization of multi-parametric properties-electrical, magnetic, and chemical signals. This review offers a cross-disciplinary perspective on the advances in SPM for biological systems, which serves as a practical guide for life scientists to select from the expanding array of SPM techniques. We outline the fundamental principles of Scanning Tunneling Microscopy (STM) and Atomic Force Microscopy (AFM), before discussing a series of advanced SPM techniques: force spectroscopy for nanomechanical characterization, Kelvin Probe Force Microscopy (KPFM) for surface potential imaging, Scanning Near-field Optical Microscopy (SNOM) for super-resolution optics, Tip-Enhanced Raman Spectroscopy (TERS) for nanoscale chemical identification, and Scanning Electrochemical Microscopy (SECM) for localized electrochemical activity detection. A systematic comparison of these technologies provides researchers with clear criteria to select the optimal methodology for diverse demands, either characterizing nucleic acids and proteins or analyzing single-cell ultrastructure and biomechanics. In addition, this review explores the transformative integration of SPM and Artificial Intelligence (AI). This integration is expected to automate SPM workflows. It will also increase the stability of SPM systems and enhance the reproducibility of experimental results. Furthermore, by addressing current challenges and future perspectives of in vivo imaging, this review aims not merely to review the progress but to empower biologists to harness these intelligent multi-modal SPM systems for groundbreaking discoveries.
- 1 January 2026
- Published by Biophysical Society of China in Biophysics Reports
- Vol. 12 (4) , 275
Open AccessAdvances in scanning probe microscopy for biological systems
Scanning Probe Microscopy (SPM), as a nanoscale characterization technique, employs a sharp probe to detect local tip-sample interactions through near-field physical phenomena. This approach achieves atomic-resolution surface imaging while enabling concurrent characterization of multi-parametric properties-electrical, magnetic, and chemical signals. This review offers a cross-disciplinary perspective on the advances in SPM for biological systems, which serves as a practical guide for life scientists to select from the expanding array of SPM techniques. We outline the fundamental principles of Scanning Tunneling Microscopy (STM) and Atomic Force Microscopy (AFM), before discussing a series of advanced SPM techniques: force spectroscopy for nanomechanical characterization, Kelvin Probe Force Microscopy (KPFM) for surface potential imaging, Scanning Near-field Optical Microscopy (SNOM) for super-resolution optics, Tip-Enhanced Raman Spectroscopy (TERS) for nanoscale chemical identification, and Scanning Electrochemical Microscopy (SECM) for localized electrochemical activity detection. A systematic comparison of these technologies provides researchers with clear criteria to select the optimal methodology for diverse demands, either characterizing nucleic acids and proteins or analyzing single-cell ultrastructure and biomechanics. In addition, this review explores the transformative integration of SPM and Artificial Intelligence (AI). This integration is expected to automate SPM workflows. It will also increase the stability of SPM systems and enhance the reproducibility of experimental results. Furthermore, by addressing current challenges and future perspectives of in vivo imaging, this review aims not merely to review the progress but to empower biologists to harness these intelligent multi-modal SPM systems for groundbreaking discoveries.
- 18 October 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 110 (14)
Growth and characterization of high-quality FeSe thin films on with enhanced superconductivity- 18 October 2024
- Published by American Physical Society (APS) in Physical Review B
- Vol. 110 (14)
Growth and characterization of high-quality FeSe thin films on with enhanced superconductivity- 1 January 2024
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 73 (22) , 228701
Advances in dry low-temperature scanning probe microscopy system development
二十一世纪以来,扫描探针显微镜(Scanning Probe Microscope,SPM)在微纳尺度形貌表征、物性测量及微纳加工等领域发挥着越来越重要的作用。为了使扫描探针显微镜获得更稳定的运行环境、更高的能量分辨率,人们研发了具备超高真空(Ultra high vacuum,UHV)和低温(Low temperature,LT)环境的SPM系统(UHV-LT-SPM)。目前,大多数的UHV-LT-SPM系统通过向连续流式低温恒温器或低温杜瓦中输送液态氦-4(4He),使SPM达到约4.2 K的温度。然而由于4He元素在自然界中含量低且因需求日益增长,导致液氦价格急剧飙升,严重影响到了4He相关低温设备的正常运行。为应对上述问题,干式制冷技术成为新一代低温技术的发展方向。在此背景下,将干式制冷技术与扫描探针显微镜相结合,搭建干式低温扫描探针显微镜,成为了目前扫描探针仪器领域的研究重点之一。 本文主要从扫描探针显微镜系统设计、降温设计、减振方法以及其设备性能等方面,介绍目前已经报道的几种干式LT-SPM系统。最后总结了干式LT-SPM系统目前所遇见的问题和挑战,探讨了该技术未来的发展方向。
- 1 January 2024
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 73 (22) , 228701
Advances in dry low-temperature scanning probe microscopy system development
二十一世纪以来,扫描探针显微镜(Scanning Probe Microscope,SPM)在微纳尺度形貌表征、物性测量及微纳加工等领域发挥着越来越重要的作用。为了使扫描探针显微镜获得更稳定的运行环境、更高的能量分辨率,人们研发了具备超高真空(Ultra high vacuum,UHV)和低温(Low temperature,LT)环境的SPM系统(UHV-LT-SPM)。目前,大多数的UHV-LT-SPM系统通过向连续流式低温恒温器或低温杜瓦中输送液态氦-4(4He),使SPM达到约4.2 K的温度。然而由于4He元素在自然界中含量低且因需求日益增长,导致液氦价格急剧飙升,严重影响到了4He相关低温设备的正常运行。为应对上述问题,干式制冷技术成为新一代低温技术的发展方向。在此背景下,将干式制冷技术与扫描探针显微镜相结合,搭建干式低温扫描探针显微镜,成为了目前扫描探针仪器领域的研究重点之一。 本文主要从扫描探针显微镜系统设计、降温设计、减振方法以及其设备性能等方面,介绍目前已经报道的几种干式LT-SPM系统。最后总结了干式LT-SPM系统目前所遇见的问题和挑战,探讨了该技术未来的发展方向。
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Development of a cryogen-free sub-3 K low-temperature scanning probe microscope by remote liquefaction scheme
We developed a new scheme for cryogen-free cooling down to sub-3 K temperature range and ultra-low vibration level. An ultra-high-vacuum cryogen-free scanning probe microscope (SPM) system was built based on the new scheme. Instead of mounting a below-decoupled cryocooler directly onto the system, the new design was realized by integrating a Gifford-McMahon cryocooler into a separate liquefying chamber, providing two-stage heat exchangers in a remote way. About 10 L of helium gas inside the gas handling system was cooled, liquefied in the liquefying chamber, and then transferred to a continuous-flow cryostat on the SPM chamber through an ∼2 m flexible helium transfer line. The exhausted helium gas from the continuous-flow cryostat was then returned to the liquefying chamber for reliquefaction. A base temperature of ∼2.84 K at the scanner sample stage and a temperature fluctuation of almost within ±0.1 mK at 4 K were achieved. The cooling curves, tunneling current noise, variable-temperature test, scanning tunneling microscopy and non-contact atomic force microscopy imaging, and first and second derivatives of I(V) spectra are characterized to verify that the performance of our cryogen-free SPM system is comparable to the bath cryostat-based low-temperature SPM system. This remote liquefaction close-cycle scheme shows conveniency to upgrade the existing bath cryostat-based SPM system, upgradeability of realizing even lower temperature down to sub-1 K range, and great compatibility of other physical environments, such as high magnetic field and optical accesses. We believe that the new scheme could also pave a way for other cryogenic applications requiring low temperature but sensitive to vibration.
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Development of a cryogen-free sub-3 K low-temperature scanning probe microscope by remote liquefaction scheme
We developed a new scheme for cryogen-free cooling down to sub-3 K temperature range and ultra-low vibration level. An ultra-high-vacuum cryogen-free scanning probe microscope (SPM) system was built based on the new scheme. Instead of mounting a below-decoupled cryocooler directly onto the system, the new design was realized by integrating a Gifford-McMahon cryocooler into a separate liquefying chamber, providing two-stage heat exchangers in a remote way. About 10 L of helium gas inside the gas handling system was cooled, liquefied in the liquefying chamber, and then transferred to a continuous-flow cryostat on the SPM chamber through an ∼2 m flexible helium transfer line. The exhausted helium gas from the continuous-flow cryostat was then returned to the liquefying chamber for reliquefaction. A base temperature of ∼2.84 K at the scanner sample stage and a temperature fluctuation of almost within ±0.1 mK at 4 K were achieved. The cooling curves, tunneling current noise, variable-temperature test, scanning tunneling microscopy and non-contact atomic force microscopy imaging, and first and second derivatives of I(V) spectra are characterized to verify that the performance of our cryogen-free SPM system is comparable to the bath cryostat-based low-temperature SPM system. This remote liquefaction close-cycle scheme shows conveniency to upgrade the existing bath cryostat-based SPM system, upgradeability of realizing even lower temperature down to sub-1 K range, and great compatibility of other physical environments, such as high magnetic field and optical accesses. We believe that the new scheme could also pave a way for other cryogenic applications requiring low temperature but sensitive to vibration.
- 1 October 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (10) , 103702
A time-shared switching scheme designed for multi-probe scanning tunneling microscope
We report the design of a time-shared switching scheme, aiming to realize the manipulation and working modes (imaging mode and transport measurement mode) switching between multiple scanning tunneling microscope (STM) probes one by one with a shared STM control system (STM CS) and an electrical transport characterization system. This scheme comprises three types of switch units, switchable preamplifiers (SWPAs), high voltage amplifiers, and a main control unit. Together with the home-made software kit providing the graphical user interface, this scheme achieves a seamless switching process between different STM probes. Compared with the conventional scheme using multiple independent STM CSs, this scheme possesses more compatibility, flexibility, and expansibility for lower cost. The overall architecture and technique issues are discussed in detail. The performances of the system are demonstrated, including the millimeter scale moving range and atomic scale resolution of a single STM probe, safely approached multiple STM probes beyond the resolution of the optical microscope (1.1 µm), qualified STM imaging, and accurate electrical transport characterization. The combinational technique of imaging and transport characterization is also shown, which is supported by SWPA switches with ultra-high open circuit resistance (909 TΩ). These successful experiments prove the effectiveness and the usefulness of the scheme. In addition, the scheme can be easily upgraded with more different functions and numbers of probe arrays, thus opening a new way to build an extremely integrated and high throughput characterization platform.
- 1 October 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (10) , 103702
A time-shared switching scheme designed for multi-probe scanning tunneling microscope
We report the design of a time-shared switching scheme, aiming to realize the manipulation and working modes (imaging mode and transport measurement mode) switching between multiple scanning tunneling microscope (STM) probes one by one with a shared STM control system (STM CS) and an electrical transport characterization system. This scheme comprises three types of switch units, switchable preamplifiers (SWPAs), high voltage amplifiers, and a main control unit. Together with the home-made software kit providing the graphical user interface, this scheme achieves a seamless switching process between different STM probes. Compared with the conventional scheme using multiple independent STM CSs, this scheme possesses more compatibility, flexibility, and expansibility for lower cost. The overall architecture and technique issues are discussed in detail. The performances of the system are demonstrated, including the millimeter scale moving range and atomic scale resolution of a single STM probe, safely approached multiple STM probes beyond the resolution of the optical microscope (1.1 µm), qualified STM imaging, and accurate electrical transport characterization. The combinational technique of imaging and transport characterization is also shown, which is supported by SWPA switches with ultra-high open circuit resistance (909 TΩ). These successful experiments prove the effectiveness and the usefulness of the scheme. In addition, the scheme can be easily upgraded with more different functions and numbers of probe arrays, thus opening a new way to build an extremely integrated and high throughput characterization platform.
- 3 March 2021
- Published by Tsinghua University Press in Nano Research
- Vol. 14 (12) , 4563-4568
Construction of poly-naphthalocyanine linked by [4]-radialene-like structures on silver surfaces
Cyclic-conjugated linkages between planar-macrocydic molecules contribute to the robustness of the two-dimensional (2D) polymerization and extension of π-interactions. The fabrication of such linkages in 2D polymers remains challenging. Combining scanning tunneling microscope (STM) measurements and density functional theory (DFT) calculations, we demonstrate a linear polymerization of metal-free naphthalocyanine (NPc) molecules with [4]-radialene-like linkages on silver surfaces. Experimentally, by depositing NPc molecules on the Ag(110) surface and subsequent annealing up to 750 K, one-dimensional polymers are constructed along the [\(1\overline 1 0\)] direction. High-resolution STM images show a stem-leaf-like feature. STM simulations based on a linear polymer of NPc molecules linked by four-membered carbon rings, [4]-radialene-like structure, agree well with the experimental observations. DFT calculations reveal that the polymerization process includes detaching two-terminal H atoms of NPc molecules along [\(1\overline 1 0\)] direction, then bonding with a neighboring dehydrogenated NPc molecule by forming a four-membered ring. The dehydrogenation process can be promoted by on-surface impurities such as additional H atoms. Similar polymerizations have been achieved on Ag(111) surfaces in an amorphous way. Moreover, the energy gap of the NPc molecule decreases after linear polymerization, suggesting a red-shift for its optical absorption/scattering spectrum. Our study offers a new route to polymerize conjugated molecules with extended planar π-interactions.- 3 March 2021
- Published by Tsinghua University Press in Nano Research
- Vol. 14 (12) , 4563-4568
Construction of poly-naphthalocyanine linked by [4]-radialene-like structures on silver surfaces
Cyclic-conjugated linkages between planar-macrocydic molecules contribute to the robustness of the two-dimensional (2D) polymerization and extension of π-interactions. The fabrication of such linkages in 2D polymers remains challenging. Combining scanning tunneling microscope (STM) measurements and density functional theory (DFT) calculations, we demonstrate a linear polymerization of metal-free naphthalocyanine (NPc) molecules with [4]-radialene-like linkages on silver surfaces. Experimentally, by depositing NPc molecules on the Ag(110) surface and subsequent annealing up to 750 K, one-dimensional polymers are constructed along the [\(1\overline 1 0\)] direction. High-resolution STM images show a stem-leaf-like feature. STM simulations based on a linear polymer of NPc molecules linked by four-membered carbon rings, [4]-radialene-like structure, agree well with the experimental observations. DFT calculations reveal that the polymerization process includes detaching two-terminal H atoms of NPc molecules along [\(1\overline 1 0\)] direction, then bonding with a neighboring dehydrogenated NPc molecule by forming a four-membered ring. The dehydrogenation process can be promoted by on-surface impurities such as additional H atoms. Similar polymerizations have been achieved on Ag(111) surfaces in an amorphous way. Moreover, the energy gap of the NPc molecule decreases after linear polymerization, suggesting a red-shift for its optical absorption/scattering spectrum. Our study offers a new route to polymerize conjugated molecules with extended planar π-interactions.- Open Access
Combinatorial Laser Molecular Beam Epitaxy System Integrated with Specialized Low-temperature Scanning Tunneling Microscopy
We present a newly developed facility, comprised of a combinatorial laser molecular beam epitaxy system and an in-situ scanning tunneling microscopy (STM). This facility aims at accelerating the materials research in a highly efficient way, by advanced high-throughput film synthesis techniques and subsequent fast characterization of surface morphology and electronic states. Compared with uniform films deposited by conventional methods, the so-called combinatorial thin films will be beneficial to determining the accurate phase diagrams of different materials due to the improved control of parameters such as chemical substitution and sample thickness resulting from a rotarymask method. A specially designed STM working under low-temperature and ultra-high vacuum conditions is optimized for the characterization of combinatorial thin films, in an XY coarse motion range of 15 mm $\times$ 15 mm and with sub-micrometer location precision. The overall configuration as well as some key aspects like sample holder design, scanner head, and sample/tip/target transfer mechanism are described in detail. The performance of the device is demonstrated by synthesizing high-quality superconducting FeSe thin films with gradient thickness, imaging surfaces of highly oriented pyrolytic graphite, Au (111), Bi2Sr2CaCu2O8+{\delta} (BSCCO) and FeSe. In addition, we have also obtained clean noise spectra of tunneling junctions and the superconducting energy gap of BSCCO. The successful manufacturing of such a facility opens a new window for the next generation of equipment designed for experimental materials research.Open AccessCombinatorial Laser Molecular Beam Epitaxy System Integrated with Specialized Low-temperature Scanning Tunneling Microscopy
We present a newly developed facility, comprised of a combinatorial laser molecular beam epitaxy system and an in-situ scanning tunneling microscopy (STM). This facility aims at accelerating the materials research in a highly efficient way, by advanced high-throughput film synthesis techniques and subsequent fast characterization of surface morphology and electronic states. Compared with uniform films deposited by conventional methods, the so-called combinatorial thin films will be beneficial to determining the accurate phase diagrams of different materials due to the improved control of parameters such as chemical substitution and sample thickness resulting from a rotarymask method. A specially designed STM working under low-temperature and ultra-high vacuum conditions is optimized for the characterization of combinatorial thin films, in an XY coarse motion range of 15 mm $\times$ 15 mm and with sub-micrometer location precision. The overall configuration as well as some key aspects like sample holder design, scanner head, and sample/tip/target transfer mechanism are described in detail. The performance of the device is demonstrated by synthesizing high-quality superconducting FeSe thin films with gradient thickness, imaging surfaces of highly oriented pyrolytic graphite, Au (111), Bi2Sr2CaCu2O8+{\delta} (BSCCO) and FeSe. In addition, we have also obtained clean noise spectra of tunneling junctions and the superconducting energy gap of BSCCO. The successful manufacturing of such a facility opens a new window for the next generation of equipment designed for experimental materials research. - 3 February 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 11 (4) , 1536-1541
Direct Visualization of Hydrogen-Transfer Intermediate States by Scanning Tunneling Microscopy
Hydrogen atoms bonded within molecular cavities often undergo tunneling or thermal-transfer processes that play major roles in diverse physical phenomena. Such transfers may or may not entail intermediate states. The existence of such fleeting states is typically determined by indirect means, while their direct visualization has not been achieved, largely because their concentrations under equilibrium conditions are negligible. Here we use density-functional-theory calculations and scanning-tunneling-microscopy (STM) image simulations to predict that, under specially designed non-equilibrium conditions of voltage-enhanced high transfer rates, the cis-intermediate of the two-hydrogen transfer process in metal-free naphthalocyanine molecules adsorbed on Ag(111) surfaces would be visualizable in a composite image of double-C morphology. As guided by the theoretical predictions, at adjusted scanning temperature and bias, STM experiments achieve a direct visualization of the cis-intermediate. This work demonstrates a practical way to directly visualize elusive intermediates, which enhances understanding of the quantum dynamics of hydrogen atoms.
- 3 February 2020
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 11 (4) , 1536-1541
Direct Visualization of Hydrogen-Transfer Intermediate States by Scanning Tunneling Microscopy
Hydrogen atoms bonded within molecular cavities often undergo tunneling or thermal-transfer processes that play major roles in diverse physical phenomena. Such transfers may or may not entail intermediate states. The existence of such fleeting states is typically determined by indirect means, while their direct visualization has not been achieved, largely because their concentrations under equilibrium conditions are negligible. Here we use density-functional-theory calculations and scanning-tunneling-microscopy (STM) image simulations to predict that, under specially designed non-equilibrium conditions of voltage-enhanced high transfer rates, the cis-intermediate of the two-hydrogen transfer process in metal-free naphthalocyanine molecules adsorbed on Ag(111) surfaces would be visualizable in a composite image of double-C morphology. As guided by the theoretical predictions, at adjusted scanning temperature and bias, STM experiments achieve a direct visualization of the cis-intermediate. This work demonstrates a practical way to directly visualize elusive intermediates, which enhances understanding of the quantum dynamics of hydrogen atoms.