Jinjun Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinjun Ye has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Zhengtao Ai
College of Civil Engineering, Hunan University, Changsha 410082, China
10 shared publications - Pawel Wargocki
Technical University of Denmark
3 shared publications - Lup Wai Chew
Department of the Built Environment, National University of Singapore, Singapore, Singapore
2 shared publications - Chen Lin
Department of Building Environment and Energy, College of Civil Engineering, Hunan University, Changsha, Hunan, China
1 shared publication Chen Zhang
1 shared publication- Chun-Ho Liu
Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
1 shared publication
Latest Publications
- Open Access
- 12 August 2026
- Published by Elsevier in Developments in the Built Environment
- Vol. 27
Estimating Reynolds number scaling thresholds in urban street canyon flows using a CFD-derived generalized linear model
- 12 August 2026
- Published by Elsevier in Developments in the Built Environment
- Vol. 27
Open AccessEstimating Reynolds number scaling thresholds in urban street canyon flows using a CFD-derived generalized linear model
- 4 September 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Cross-seasonal investigation of chemical pollution characteristics in funeral workspaces: from corpse refrigeration to cremation
- 4 September 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Cross-seasonal investigation of chemical pollution characteristics in funeral workspaces: from corpse refrigeration to cremation
- 5 February 2025
- Published by Elsevier in Building and Environment
- Vol. 272
Indoor pollution of funeral homes and potential health risk of workers: A case study in central China
- 5 February 2025
- Published by Elsevier in Building and Environment
- Vol. 272
Indoor pollution of funeral homes and potential health risk of workers: A case study in central China
- 13 September 2024
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 34 (2) , 302-318
Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
In-duct ultraviolet germicidal irradiation systems (ID-UVs) is a promising technology for the development of biosecure buildings. This study explored the Computational Fluid Dynamics (CFD) method for accurately predicting the inactivation efficiency of ID-UVs. The results showed that the setting of ‘Divisions’ is crucial to the accuracy of radiation field modelling, and 15 × 15 was considered to be a reasonable value in this study. In addition, residence time and deposition ratio are two crucial parameters determining the average UV dose (AD) received by microbial particles, thereby influencing the inactivation efficiency. For ID-UVs without ribs, the Renormalization Group (RNG) k ‐ ε model largely overestimated these two parameters, while the Reynolds Stress Model (RSM) with correcting fluctuation velocity improved the predictive accuracy of AD by 10.0%. For ID-UVs with ribs, the RNG k ‐ ε model overestimated the eddy size and AD by 28.6% and 12.0%, respectively. The RSM model provided results closer to the Large Eddy Simulation. Adding 0.10 H (H: duct height) ribs increased the inactivation efficiency for MS2 Bacteriophage by 19.0%–64.3%, with an additional pressure drop of only 3.3 Pa. These findings contributed to a reliable CFD framework and provided novel ideas for improving inactivation efficiency.
- 13 September 2024
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 34 (2) , 302-318
Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
In-duct ultraviolet germicidal irradiation systems (ID-UVs) is a promising technology for the development of biosecure buildings. This study explored the Computational Fluid Dynamics (CFD) method for accurately predicting the inactivation efficiency of ID-UVs. The results showed that the setting of ‘Divisions’ is crucial to the accuracy of radiation field modelling, and 15 × 15 was considered to be a reasonable value in this study. In addition, residence time and deposition ratio are two crucial parameters determining the average UV dose (AD) received by microbial particles, thereby influencing the inactivation efficiency. For ID-UVs without ribs, the Renormalization Group (RNG) k ‐ ε model largely overestimated these two parameters, while the Reynolds Stress Model (RSM) with correcting fluctuation velocity improved the predictive accuracy of AD by 10.0%. For ID-UVs with ribs, the RNG k ‐ ε model overestimated the eddy size and AD by 28.6% and 12.0%, respectively. The RSM model provided results closer to the Large Eddy Simulation. Adding 0.10 H (H: duct height) ribs increased the inactivation efficiency for MS2 Bacteriophage by 19.0%–64.3%, with an additional pressure drop of only 3.3 Pa. These findings contributed to a reliable CFD framework and provided novel ideas for improving inactivation efficiency.
- 20 January 2022
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 31 (5) , 1176-1192
Systematic summary and analysis of Chinese HVAC guidelines coping with COVID-19
Heating, Ventilation, and Air-Conditioning (HVAC) system that is almost indispensable service system of modern buildings is recognized as the most important engineering control measure against pandemics. However, the effectiveness of HVAC systems has been questioned on their ability to control airborne transmission. After the outbreak of COVID-19, China has controlled the spread within a relatively short period. Considering the large population, high population density, busy transportation and the overall underdeveloped economy, China’s control measures may have some implications to other countries, especially those with limited resources. This paper intends to provide a systematic summary of Chinese ventilation guidelines issued to cope with COVID-19 transmission. The following three aspects are the main focus of these guidelines: (1) general operation and management schemes of various types of HVAC systems, (2) operation and management schemes of HVAC system in typical types of buildings, and (3) design schemes of HVAC system of makeshift hospitals. In addition, some important differences in HVAC guidelines between China and other countries/institutions are identified and compared, and the possible reasons are discussed. Further discussions are made on the following topics, including the required fresh air supply, the extended operation time, the use of auxiliary equipment, the limited capacity of existing systems, and the use of personalized systems.
- 20 January 2022
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 31 (5) , 1176-1192
Systematic summary and analysis of Chinese HVAC guidelines coping with COVID-19
Heating, Ventilation, and Air-Conditioning (HVAC) system that is almost indispensable service system of modern buildings is recognized as the most important engineering control measure against pandemics. However, the effectiveness of HVAC systems has been questioned on their ability to control airborne transmission. After the outbreak of COVID-19, China has controlled the spread within a relatively short period. Considering the large population, high population density, busy transportation and the overall underdeveloped economy, China’s control measures may have some implications to other countries, especially those with limited resources. This paper intends to provide a systematic summary of Chinese ventilation guidelines issued to cope with COVID-19 transmission. The following three aspects are the main focus of these guidelines: (1) general operation and management schemes of various types of HVAC systems, (2) operation and management schemes of HVAC system in typical types of buildings, and (3) design schemes of HVAC system of makeshift hospitals. In addition, some important differences in HVAC guidelines between China and other countries/institutions are identified and compared, and the possible reasons are discussed. Further discussions are made on the following topics, including the required fresh air supply, the extended operation time, the use of auxiliary equipment, the limited capacity of existing systems, and the use of personalized systems.