Jiaxin Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaxin Fan has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Cicoira
Department of Chemical Engineering Polytechnique Montréal Montréal Quebec Canada
9 shared publications - Jinsil Kim
Department of chemical engineering, Polytechnique Montréal, Montréal, QC H3C 3A7, Canada
4 shared publications - Manisha Gupta
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada
4 shared publications - Pierre Kateb
Biomedical and Mobile Health Technology Lab Department of Health Sciences and Technology ETH Zurich Lengghalde 5 8008 Zürich Switzerland
3 shared publications - Seongdae Kang
Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada
3 shared publications - Chi-Hyeong Kim
Department of Chemical Engineering Polytechnique Montréal Montreal H3T 1J4 Canada
2 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by IOP Publishing in Nano Futures
- Vol. 10 (3) , 035002
Towards standardized high-voltage testing of printed conducting polymer electrodes: influence of electrolyte environment and pulse duration
Printed PEDOT:PSS electrodes are widely used in bioelectronics and soft electronic interfaces, where they can be exposed to high voltage and pulsed electrical stimulation. However, the operational limits of conducting polymer electrodes under high electric fields remain poorly defined, particularly across different electrolyte environments and time scales. Here, we present a systematic approach to evaluate the electrical response of direct-ink-written PEDOT: PSS thin films under high-voltage operation in dry conditions, in an aqueous electrolyte (phosphate-buffered saline), and in a non-aqueous ionic liquid. Electrical characterization was performed using constant-voltage measurements, voltage sweeps, and monophasic voltage pulses with durations ranging from 1 ms to 1 s, allowing the separation of steady-state and time-dependent electrical behavior. PEDOT:PSS films remained electrically stable up to 40 V in dry conditions, while the stability threshold decreased to approximately 1.2 V in aqueous electrolyte and 5 V in ionic liquid. Under pulsed operation, shorter pulse durations reduced current drift and limited the development of electrochemical processes, demonstrating that the electrical response is strongly governed by both the electrolyte environment and the time scale of the applied voltage. These results provide practical guidelines for operating conducting polymer electrodes under high electric fields and establish a reproducible framework for evaluating their stability under steady-state and pulsed conditions, which is relevant for emerging bioelectronic and soft electronic technologies.
- 12 August 2026
- Published by IOP Publishing in Nano Futures
- Vol. 10 (3) , 035002
Open AccessTowards standardized high-voltage testing of printed conducting polymer electrodes: influence of electrolyte environment and pulse duration
Printed PEDOT:PSS electrodes are widely used in bioelectronics and soft electronic interfaces, where they can be exposed to high voltage and pulsed electrical stimulation. However, the operational limits of conducting polymer electrodes under high electric fields remain poorly defined, particularly across different electrolyte environments and time scales. Here, we present a systematic approach to evaluate the electrical response of direct-ink-written PEDOT: PSS thin films under high-voltage operation in dry conditions, in an aqueous electrolyte (phosphate-buffered saline), and in a non-aqueous ionic liquid. Electrical characterization was performed using constant-voltage measurements, voltage sweeps, and monophasic voltage pulses with durations ranging from 1 ms to 1 s, allowing the separation of steady-state and time-dependent electrical behavior. PEDOT:PSS films remained electrically stable up to 40 V in dry conditions, while the stability threshold decreased to approximately 1.2 V in aqueous electrolyte and 5 V in ionic liquid. Under pulsed operation, shorter pulse durations reduced current drift and limited the development of electrochemical processes, demonstrating that the electrical response is strongly governed by both the electrolyte environment and the time scale of the applied voltage. These results provide practical guidelines for operating conducting polymer electrodes under high electric fields and establish a reproducible framework for evaluating their stability under steady-state and pulsed conditions, which is relevant for emerging bioelectronic and soft electronic technologies.
- Open Access
- 24 June 2026
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 11 (3) , 032501
The 2025 PEDOT roadmap
This roadmap presents key advances and future directions in the field of the conducting polymer polyethylene dioxythiophene (PEDOT), with a focus on its role as multifunctional material in emerging electronic applications. It covers a broad spectrum of topics, including self-healing materials, plant bioelectronics, energy harvesting and storage, and neural interfaces. The roadmap also addresses recent progress in the synthesis and functionalization of PEDOT derivatives, as well as insights from molecular dynamics simulations and transport physics. Emphasis is placed on a range of processing techniques, such as electropolymerization, vapor phase polymerization, and 3D printing, and their implications for device performance. Specific applications explored include thermoelectrics, biosensors, organic electrochemical transistors, and advanced bioelectronic platforms for neuromodulation, stretchable electronics, and neuromorphic computing. This collective effort aims to serve as a comprehensive resource outlining the current state of PEDOT research and identifying challenges and opportunities for its integration across diverse electronic technologies.
- 24 June 2026
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 11 (3) , 032501
Open AccessThe 2025 PEDOT roadmap
This roadmap presents key advances and future directions in the field of the conducting polymer polyethylene dioxythiophene (PEDOT), with a focus on its role as multifunctional material in emerging electronic applications. It covers a broad spectrum of topics, including self-healing materials, plant bioelectronics, energy harvesting and storage, and neural interfaces. The roadmap also addresses recent progress in the synthesis and functionalization of PEDOT derivatives, as well as insights from molecular dynamics simulations and transport physics. Emphasis is placed on a range of processing techniques, such as electropolymerization, vapor phase polymerization, and 3D printing, and their implications for device performance. Specific applications explored include thermoelectrics, biosensors, organic electrochemical transistors, and advanced bioelectronic platforms for neuromodulation, stretchable electronics, and neuromorphic computing. This collective effort aims to serve as a comprehensive resource outlining the current state of PEDOT research and identifying challenges and opportunities for its integration across diverse electronic technologies.
- Open Access
- 2 December 2025
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 7 (2) , 960-968
Optimization of drop-casting parameters for fabrication of n-type accumulation mode organic electrochemical transistors (OECTs) using gNDI-Br 2
GNDI-Br 2 OMIEC drop-casted organic electrochemical transistor (OECT) with high transconductance.
- 2 December 2025
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 7 (2) , 960-968
Open AccessOptimization of drop-casting parameters for fabrication of n-type accumulation mode organic electrochemical transistors (OECTs) using gNDI-Br 2
GNDI-Br 2 OMIEC drop-casted organic electrochemical transistor (OECT) with high transconductance.
- Open Access
- 13 August 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (27) , e02269
Conducting Polymer Coatings for Bioelectronic Arthroscopy Probes
This study presents conducting polymer coatings as an effective strategy to enhance the performance of electromechanical arthroscopy probes by significantly reducing electrical equilibration time (the period a surgeon must wait for the probe signal to stabilize before measurement) and improving signal stability. Microelectrodes coated with poly(3,4‐ethylenedioxythiophene, PEDOT) reach electrical equilibrium in physiological medium within 10 s, compared to over 2 min for standard electroless nickel immersion gold‐based (ENIG) probes and ≈20 s for electrodeposited gold, thereby eliminating impractical delays during arthroscopic procedures. PEDOT coatings also reduce impedance by two to three orders of magnitude at low frequencies (<1 kHz), minimizing sensitivity to hand motion and reducing the likelihood of repeated measurements. Importantly, these electrodes maintain their functionality after sterilization and repeated use, demonstrating high reliability for intraoperative applications. Furthermore, PEDOT‐coated nickel‐phosphorus (Ni‐P) microelectrodes offer a gold‐free, cost‐effective, and sustainable alternative. As osteoarthritis continues to affect a growing global population, the development of rapid, durable, and accessible diagnostic tools is increasingly critical. The integration of PEDOT into arthroscopic microelectrodes represents a clinically promising approach to faster, more efficient cartilage assessment while reducing reliance on critical raw materials.
- 13 August 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (27) , e02269
Open AccessConducting Polymer Coatings for Bioelectronic Arthroscopy Probes
This study presents conducting polymer coatings as an effective strategy to enhance the performance of electromechanical arthroscopy probes by significantly reducing electrical equilibration time (the period a surgeon must wait for the probe signal to stabilize before measurement) and improving signal stability. Microelectrodes coated with poly(3,4‐ethylenedioxythiophene, PEDOT) reach electrical equilibrium in physiological medium within 10 s, compared to over 2 min for standard electroless nickel immersion gold‐based (ENIG) probes and ≈20 s for electrodeposited gold, thereby eliminating impractical delays during arthroscopic procedures. PEDOT coatings also reduce impedance by two to three orders of magnitude at low frequencies (<1 kHz), minimizing sensitivity to hand motion and reducing the likelihood of repeated measurements. Importantly, these electrodes maintain their functionality after sterilization and repeated use, demonstrating high reliability for intraoperative applications. Furthermore, PEDOT‐coated nickel‐phosphorus (Ni‐P) microelectrodes offer a gold‐free, cost‐effective, and sustainable alternative. As osteoarthritis continues to affect a growing global population, the development of rapid, durable, and accessible diagnostic tools is increasingly critical. The integration of PEDOT into arthroscopic microelectrodes represents a clinically promising approach to faster, more efficient cartilage assessment while reducing reliance on critical raw materials.
- Open Access
- 31 March 2025
- Published by Wiley in Small Science
- Vol. 5 (5)
Recyclable Printed Liquid Metal Composite for Underwater Stretchable Electronics
Multifunctional stretchable conductors are crucial components in fully stretchable circuits for wearable bioelectronics. Conductive composites made from liquid metal (LM) fillers and polymer matrices have garnered significant interest due to their high electrical conductivity, adjustable mechanical properties, biocompatibility, and recyclability. Herein, a printable LM composite is developed using a custom‐designed block copolymer to ensure electromechanical stability in both wet and dry conditions. The LM composite demonstrates high conductivity (around 105 S m−1), stretchability up to 500%, and maintains stable resistance with cyclic strain ranging from 0 to 50% for over 16 h, in both ambient and aqueous environments. Furthermore, bulk LM is successfully recovered from printed composites using green solvents, supporting the composite's recyclability.
- 31 March 2025
- Published by Wiley in Small Science
- Vol. 5 (5)
Open AccessRecyclable Printed Liquid Metal Composite for Underwater Stretchable Electronics
Multifunctional stretchable conductors are crucial components in fully stretchable circuits for wearable bioelectronics. Conductive composites made from liquid metal (LM) fillers and polymer matrices have garnered significant interest due to their high electrical conductivity, adjustable mechanical properties, biocompatibility, and recyclability. Herein, a printable LM composite is developed using a custom‐designed block copolymer to ensure electromechanical stability in both wet and dry conditions. The LM composite demonstrates high conductivity (around 105 S m−1), stretchability up to 500%, and maintains stable resistance with cyclic strain ranging from 0 to 50% for over 16 h, in both ambient and aqueous environments. Furthermore, bulk LM is successfully recovered from printed composites using green solvents, supporting the composite's recyclability.
- Open Access
- 13 June 2024
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 11 (15) , 3548-3560
Self-healing, stretchable and recyclable polyurethane-PEDOT:PSS conductive blends
Future electronics call for materials with mechanical toughness, flexibility, and stretchability. Moreover, self-healing and recyclability are highly desirable to mitigate the escalating environmental threat of electronic waste (e-waste). Herein, we report a stretchable, self-healing, and recyclable material based on a mixture of the conductive polymer poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) with a custom-designed polyurethane (PU) and polyethylene glycol (PEG). This material showed excellent elongation at brake (∼350%), high toughness (∼24.6 MJ m−3), moderate electrical conductivity (∼10 S cm−1), and outstanding mechanical and electrical healing efficiencies. In addition, it demonstrated exceptional recyclability with no significant loss in the mechanical and electrical properties after being recycled 20 times. Based on these properties, as a proof of principle for sustainable electronic devices, we demonstrated that electrocardiogram (ECG) electrodes and pressure sensors based on this material could be recycled without significant performance loss. The development of multifunctional electronic materials that are self-healing and fully recyclable is a promising step toward sustainable electronics, offering a potential solution to the e-waste challenge.
- 13 June 2024
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 11 (15) , 3548-3560
Open AccessSelf-healing, stretchable and recyclable polyurethane-PEDOT:PSS conductive blends
Future electronics call for materials with mechanical toughness, flexibility, and stretchability. Moreover, self-healing and recyclability are highly desirable to mitigate the escalating environmental threat of electronic waste (e-waste). Herein, we report a stretchable, self-healing, and recyclable material based on a mixture of the conductive polymer poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) with a custom-designed polyurethane (PU) and polyethylene glycol (PEG). This material showed excellent elongation at brake (∼350%), high toughness (∼24.6 MJ m−3), moderate electrical conductivity (∼10 S cm−1), and outstanding mechanical and electrical healing efficiencies. In addition, it demonstrated exceptional recyclability with no significant loss in the mechanical and electrical properties after being recycled 20 times. Based on these properties, as a proof of principle for sustainable electronic devices, we demonstrated that electrocardiogram (ECG) electrodes and pressure sensors based on this material could be recycled without significant performance loss. The development of multifunctional electronic materials that are self-healing and fully recyclable is a promising step toward sustainable electronics, offering a potential solution to the e-waste challenge.
- Open Access
- 13 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (16) , 5708-5717
Conducting polymer films and bioelectrodes combining high adhesion and electro-mechanical self-healing
Self-healable, conductive, soft, and stretchable electronic materials have become research hotspots in wearable and bioelectronic devices for healthcare monitoring. In this study, conductive, soft, stretchable, self-healing, highly adhesive, and biocompatible conductive polymer films were obtained by mixing poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS), ethylene glycol (EG), and tannic acid (TA). The films with optimized composition demonstrated very attractive properties for wearable electronics and bioelectronics, including a conductivity of ∼17 S cm−1, a low Young's modulus of ∼450 kPa, stretchability of ∼90% strain, outstanding electrical stability during stretching (2% resistance change at 30% strain), and strong adhesion on several substrates. Notably, the films exhibited outstanding autonomous and cut-stick healing properties, enabled by the addition of TA. Furthermore, the films exhibited no signs of cytotoxicity, making them suitable for biomedical applications. Epidermal electrodes prepared using these materials exhibit low skin-electrode impedance at low frequencies (1–100 Hz) and high quality for electrocardiography (ECG) and electromyography (EMG) signal recordings. This study promotes the development of innovative wearable biomedical devices and contribute to personalized healthcare monitoring.
- 13 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (16) , 5708-5717
Open AccessConducting polymer films and bioelectrodes combining high adhesion and electro-mechanical self-healing
Self-healable, conductive, soft, and stretchable electronic materials have become research hotspots in wearable and bioelectronic devices for healthcare monitoring. In this study, conductive, soft, stretchable, self-healing, highly adhesive, and biocompatible conductive polymer films were obtained by mixing poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS), ethylene glycol (EG), and tannic acid (TA). The films with optimized composition demonstrated very attractive properties for wearable electronics and bioelectronics, including a conductivity of ∼17 S cm−1, a low Young's modulus of ∼450 kPa, stretchability of ∼90% strain, outstanding electrical stability during stretching (2% resistance change at 30% strain), and strong adhesion on several substrates. Notably, the films exhibited outstanding autonomous and cut-stick healing properties, enabled by the addition of TA. Furthermore, the films exhibited no signs of cytotoxicity, making them suitable for biomedical applications. Epidermal electrodes prepared using these materials exhibit low skin-electrode impedance at low frequencies (1–100 Hz) and high quality for electrocardiography (ECG) and electromyography (EMG) signal recordings. This study promotes the development of innovative wearable biomedical devices and contribute to personalized healthcare monitoring.
- Open Access
- 16 November 2023
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 8 (4) , 045006
Printable, adhesive, and self-healing dry epidermal electrodes based on PEDOT:PSS and polyurethane diol
Printable, self-healing, stretchable, and conductive materials have tremendous potential for the fabrication of advanced electronic devices. Poly(3,4-ethylenedioxithiopene) doped with polystyrene sulfonate (PEDOT:PSS) has been the focus of extensive research due to its tunable electrical and mechanical properties. Owing to its solution-processability and self-healing ability, PEDOT:PSS is an excellent candidate for developing printable inks. In this study, we developed printable, stretchable, dry, lightly adhesive, and self-healing materials for biomedical applications. Polyurethane diol (PUD), polyethylene glycol, and sorbitol were investigated as additives for PEDOT:PSS. In this study, we identified an optimal printable mixture obtained by adding PUD to PEDOT:PSS, which improved both the mechanical and electrical properties. PUD/PEDOT:PSS free-standing films with optimized composition showed a conductivity of approximately 30 S cm−1, stretchability of 30%, and Young’s modulus of 15 MPa. A low resistance change (<20%) was achieved when the strain was increased to 30%. Excellent electrical stability under cyclic mechanical strain, biocompatibility, and 100% electrical self-healing were also observed. The potential biomedical applications of this mixture were demonstrated by fabricating a printed epidermal electrode on a stretchable silicone substrate. The PUD/PEDOT:PSS electrodes displayed a skin-electrode impedance similar to commercially available ones, and successfully captured physiological signals. This study contributes to the development of improved customization and enhanced mechanical durability of soft electronic materials.
- 16 November 2023
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 8 (4) , 045006
Open AccessPrintable, adhesive, and self-healing dry epidermal electrodes based on PEDOT:PSS and polyurethane diol
Printable, self-healing, stretchable, and conductive materials have tremendous potential for the fabrication of advanced electronic devices. Poly(3,4-ethylenedioxithiopene) doped with polystyrene sulfonate (PEDOT:PSS) has been the focus of extensive research due to its tunable electrical and mechanical properties. Owing to its solution-processability and self-healing ability, PEDOT:PSS is an excellent candidate for developing printable inks. In this study, we developed printable, stretchable, dry, lightly adhesive, and self-healing materials for biomedical applications. Polyurethane diol (PUD), polyethylene glycol, and sorbitol were investigated as additives for PEDOT:PSS. In this study, we identified an optimal printable mixture obtained by adding PUD to PEDOT:PSS, which improved both the mechanical and electrical properties. PUD/PEDOT:PSS free-standing films with optimized composition showed a conductivity of approximately 30 S cm−1, stretchability of 30%, and Young’s modulus of 15 MPa. A low resistance change (<20%) was achieved when the strain was increased to 30%. Excellent electrical stability under cyclic mechanical strain, biocompatibility, and 100% electrical self-healing were also observed. The potential biomedical applications of this mixture were demonstrated by fabricating a printed epidermal electrode on a stretchable silicone substrate. The PUD/PEDOT:PSS electrodes displayed a skin-electrode impedance similar to commercially available ones, and successfully captured physiological signals. This study contributes to the development of improved customization and enhanced mechanical durability of soft electronic materials.
- 6 April 2023
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 246, 540-555
Effect of ionic conductivity of electrolyte on printed planar and vertical organic electrochemical transistors
We investigated the impact of two semi-solid gel electrolytes, iongel and organogel, with different ionic conductivities on the performance of printed planar and vertical organic electrochemical transistors (OECTs).
- 6 April 2023
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 246, 540-555
Effect of ionic conductivity of electrolyte on printed planar and vertical organic electrochemical transistors
We investigated the impact of two semi-solid gel electrolytes, iongel and organogel, with different ionic conductivities on the performance of printed planar and vertical organic electrochemical transistors (OECTs).
- 1 March 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (14) , 4623-4633
Electrical and mechanical stability of flexible, organic electrolyte-gated transistors based on iongel and hydrogels
Electrolyte-gated transistors (EGTs) have been widely investigated for applications in bioelectronics owing to their low operating voltage and mixed ionic–electronic conduction. The ion-gating media play a primary role in determining the operating voltage and electrical stability of these devices. In this study, we employed an iongel based on an ionic liquid and hydrogels based on polyvinyl alcohol (PVA) as the gating media for EGTs using the organic semiconductor poly(N-alkyldiketopyrrolo-pyrrole-dithienylthieno[3,2-b]thiophene) (DPP-DTT) as the channel material. The device characteristics revealed that iongel-gated transistors showed superior electrical stability over hydrogel-gated transistors, because hydrogels undergo dehydration over time. After 65 cycles of pulse measurements, the drain current of the iongel-gated devices did not show any significant change, whereas it decreased to ∼50% of the initial value for the hydrogel-gated devices. By adding glycerol as an anti-dehydrating agent, the current decreased by only ∼10% under the same conditions, demonstrating improved operational stability. Finally, we fabricated flexible EGTs on polyethylene terephthalate (PET), which can be operated under different bending radii.
- 1 March 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (14) , 4623-4633
Electrical and mechanical stability of flexible, organic electrolyte-gated transistors based on iongel and hydrogels
Electrolyte-gated transistors (EGTs) have been widely investigated for applications in bioelectronics owing to their low operating voltage and mixed ionic–electronic conduction. The ion-gating media play a primary role in determining the operating voltage and electrical stability of these devices. In this study, we employed an iongel based on an ionic liquid and hydrogels based on polyvinyl alcohol (PVA) as the gating media for EGTs using the organic semiconductor poly(N-alkyldiketopyrrolo-pyrrole-dithienylthieno[3,2-b]thiophene) (DPP-DTT) as the channel material. The device characteristics revealed that iongel-gated transistors showed superior electrical stability over hydrogel-gated transistors, because hydrogels undergo dehydration over time. After 65 cycles of pulse measurements, the drain current of the iongel-gated devices did not show any significant change, whereas it decreased to ∼50% of the initial value for the hydrogel-gated devices. By adding glycerol as an anti-dehydrating agent, the current decreased by only ∼10% under the same conditions, demonstrating improved operational stability. Finally, we fabricated flexible EGTs on polyethylene terephthalate (PET), which can be operated under different bending radii.