Thomas E. Field
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas E. Field has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jayanth R. Ramamurthy
Entergy Corporation, Jackson, MS, USA
3 shared publications - Mohammad Mehdi Rezvani
Transmission Planning, Electric Reliability Council of Texas (ERCOT), Austin, TX, USA
3 shared publications - Shahab Mehraeen
ECE Department, Louisiana State University, Baton Rouge, LA, USA
3 shared publications - Bikrant Poudel
University of New Orleans, New Orleans, USA
2 shared publications - Ebrahim Amiri
Electrical Engineering Department, California State University at Long Beach, Long Beach, CA, USA
2 shared publications Parviz Rastgoufard
Department of Electrical, Computer Engineering, University of New Orleans, New Orleans, LA, USA
2 shared publications
Latest Publications
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2300-2312
Experimental Analysis of Transmission Line Protection Functions in Grid-Connected IBR
This paper investigates protection challenges for line current differential (87 L) and distance protection function (21) posed by the integration of inverter-based resources (IBR) into transmission systems. The reliability of these functions is investigated in a weak in-feed system, where the IBR is the only source of fault current. The analysis of the protection schemes is performed on a real-world 25 bus network system, using a time-domain transient program (EMTP). The test system is interconnected with an IBR source, converted into a white-box model in accordance with IEEE 2800-2022 matching the negative sequence injection, phase angle, voltage ride through, and reactive power control strategy. The IBR response to 15 fault cases is simulated and tested against EMTP protection function models, then recorded into COMTRADE files. These files are used in a power system simulator to test the response of manufacturer's 87 L and 21 protection functions inside three different types of physical microprocessor relays. The following was concluded: the simulation tripping time response matches closely to the hardware tripping time response, the relaying philosophy used in the presence of synchronous generators is not sufficient due to the unique IBR fault response, the effect on overcurrent supervisors of 21 and 87 L relays must be carefully considered, and ground protection functions are impacted based on the presence of a grounding transformer in the IBR.
- 25 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2300-2312
Experimental Analysis of Transmission Line Protection Functions in Grid-Connected IBR
This paper investigates protection challenges for line current differential (87 L) and distance protection function (21) posed by the integration of inverter-based resources (IBR) into transmission systems. The reliability of these functions is investigated in a weak in-feed system, where the IBR is the only source of fault current. The analysis of the protection schemes is performed on a real-world 25 bus network system, using a time-domain transient program (EMTP). The test system is interconnected with an IBR source, converted into a white-box model in accordance with IEEE 2800-2022 matching the negative sequence injection, phase angle, voltage ride through, and reactive power control strategy. The IBR response to 15 fault cases is simulated and tested against EMTP protection function models, then recorded into COMTRADE files. These files are used in a power system simulator to test the response of manufacturer's 87 L and 21 protection functions inside three different types of physical microprocessor relays. The following was concluded: the simulation tripping time response matches closely to the hardware tripping time response, the relaying philosophy used in the presence of synchronous generators is not sufficient due to the unique IBR fault response, the effect on overcurrent supervisors of 21 and 87 L relays must be carefully considered, and ground protection functions are impacted based on the presence of a grounding transformer in the IBR.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (2) , 1502-1511
Dynamic Interaction of Distribution-Connected DER_A With Transmission System Via Co-Simulation Analysis
A coupled load flow algorithm is developed to perform transmission and distribution (T&D) co-simulation. Subsequently, the effects of distributed energy resources (DERs) on the dynamics of power systems are studied by extending the T&D load flow algorithm to T&D dynamic co-simulation. The detailed distribution and transmission systems are modeled separately and are coupled at the substation nodes at each time step. Dynamics of the DER_A mechanisms are modeled separately downstream of the distribution substation using the North American Electric Reliability Corporation model (NERC-2018). The effects of the DER_A settings are examined on the dynamics of the transmission system and DER operation. In addition, lumped and distributed induction motor load models are compared at the distribution level. The results of the study show that under high DER penetration excessive operation may occur at the distribution load tap changers. Also, the effect of reactive power on voltage recovery is significant under DER high fault-ride-through capability and DER reactive current injections. Moreover, it is observed that DER frequency control may adversely affect the DER operation keeping the active and reactive currents at high levels due to frequency deviations. Finally, distributed induction motor loads stimulate more DER reactive power injection causing voltage overshoots.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (2) , 1502-1511
Dynamic Interaction of Distribution-Connected DER_A With Transmission System Via Co-Simulation Analysis
A coupled load flow algorithm is developed to perform transmission and distribution (T&D) co-simulation. Subsequently, the effects of distributed energy resources (DERs) on the dynamics of power systems are studied by extending the T&D load flow algorithm to T&D dynamic co-simulation. The detailed distribution and transmission systems are modeled separately and are coupled at the substation nodes at each time step. Dynamics of the DER_A mechanisms are modeled separately downstream of the distribution substation using the North American Electric Reliability Corporation model (NERC-2018). The effects of the DER_A settings are examined on the dynamics of the transmission system and DER operation. In addition, lumped and distributed induction motor load models are compared at the distribution level. The results of the study show that under high DER penetration excessive operation may occur at the distribution load tap changers. Also, the effect of reactive power on voltage recovery is significant under DER high fault-ride-through capability and DER reactive current injections. Moreover, it is observed that DER frequency control may adversely affect the DER operation keeping the active and reactive currents at high levels due to frequency deviations. Finally, distributed induction motor loads stimulate more DER reactive power injection causing voltage overshoots.
- 25 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 4809-4819
A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System With PVs
Global sensitivity analysis (GSA) of distribution system with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution system. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of load and PV power injections. The sampling-based method estimates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-bus distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.
- 25 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 4809-4819
A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System With PVs
Global sensitivity analysis (GSA) of distribution system with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution system. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of load and PV power injections. The sampling-based method estimates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-bus distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.
- Open Access
- 3 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 7, 307-319
Hardware-in-the-Loop Testing of Dynamic Grid Voltages for Static Var Compensator Controllers With Single-Phase Induction Motor Loads
This paper investigates the interaction between two Static var Compensators (SVCs) to verify dynamic grid voltage support is maintained and that the SVC controllers do not negatively interact with each other. For this purpose, the controls of the SVCs with all of the remotely controlled Mechanically-Switched Capacitors (MSCs) have been tested in a closed-loop real-time simulator environment using SVC replicas (physical controllers) of the actual field installations. To accurately capture the power systems response to phenomenon such as potential Fault Induced Delayed Voltage Recovery (FIDVR), the dynamics of the generators and the motor loads are modeled in the simulations. A hybrid model consisting of real and reactive power (P-Q) loads and aggregated motor load of a single-phase induction motor suitable for three-phase time-domain simulation was developed and connected to the power system. The developed aggregate motor load model includes details such as the main winding, auxiliary winding, starting capacitor, motor inertia, and distribution transformers. It is observed that dynamic grid voltage support can be maintained and the SVC controllers do not negatively interact with each other if all the SVC control blocks are enabled and function normally.
- 3 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 7, 307-319
Open AccessHardware-in-the-Loop Testing of Dynamic Grid Voltages for Static Var Compensator Controllers With Single-Phase Induction Motor Loads
This paper investigates the interaction between two Static var Compensators (SVCs) to verify dynamic grid voltage support is maintained and that the SVC controllers do not negatively interact with each other. For this purpose, the controls of the SVCs with all of the remotely controlled Mechanically-Switched Capacitors (MSCs) have been tested in a closed-loop real-time simulator environment using SVC replicas (physical controllers) of the actual field installations. To accurately capture the power systems response to phenomenon such as potential Fault Induced Delayed Voltage Recovery (FIDVR), the dynamics of the generators and the motor loads are modeled in the simulations. A hybrid model consisting of real and reactive power (P-Q) loads and aggregated motor load of a single-phase induction motor suitable for three-phase time-domain simulation was developed and connected to the power system. The developed aggregate motor load model includes details such as the main winding, auxiliary winding, starting capacitor, motor inertia, and distribution transformers. It is observed that dynamic grid voltage support can be maintained and the SVC controllers do not negatively interact with each other if all the SVC control blocks are enabled and function normally.
- Open Access
- 17 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Industry Applications
- Vol. 1, 23-32
Interaction of Transmission-Distribution System in the Presence of DER Units–Co-simulation Approach
The effects of distribution-connected solar farms on the transmission and distribution systems are studied in this paper using a practical power system network. Both the transmission and distribution networks are modeled and co-simulated for intermittent effects of solar power and changing load profiles. These effects include, flicker in both the transmission and the distribution systems, operation of the substation Load Tap Changer (LTC) and feeder regulators, and distribution feeder voltage profiles. The results of the study show a potential hunting effect causing excessive LTC operation especially during periods of high reverse power flow condition and a significant visible flicker in the distribution system but lower levels of flicker at the transmission level. It is shown that the hunting behavior of the LTC can be mitigated and downstream feeder voltage profiles can be improved via enhanced bandwidth, block operation mode, and adjusting time delay of the substation LTC controller. In addition, the inverter Volt-Var control can be used to effectively diminish excessive LTC operation based on IEEE Std 1547-2018 Volt-Var characteristics with modified settings. Finally, an enhanced load-flow algorithm with modified Jacobian is presented that incorporates the Distributed Energy Resource (DER) Volt-Var characteristics in the conventional Newton-Raphson method.
- 17 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Industry Applications
- Vol. 1, 23-32
Open AccessInteraction of Transmission-Distribution System in the Presence of DER Units–Co-simulation Approach
The effects of distribution-connected solar farms on the transmission and distribution systems are studied in this paper using a practical power system network. Both the transmission and distribution networks are modeled and co-simulated for intermittent effects of solar power and changing load profiles. These effects include, flicker in both the transmission and the distribution systems, operation of the substation Load Tap Changer (LTC) and feeder regulators, and distribution feeder voltage profiles. The results of the study show a potential hunting effect causing excessive LTC operation especially during periods of high reverse power flow condition and a significant visible flicker in the distribution system but lower levels of flicker at the transmission level. It is shown that the hunting behavior of the LTC can be mitigated and downstream feeder voltage profiles can be improved via enhanced bandwidth, block operation mode, and adjusting time delay of the substation LTC controller. In addition, the inverter Volt-Var control can be used to effectively diminish excessive LTC operation based on IEEE Std 1547-2018 Volt-Var characteristics with modified settings. Finally, an enhanced load-flow algorithm with modified Jacobian is presented that incorporates the Distributed Energy Resource (DER) Volt-Var characteristics in the conventional Newton-Raphson method.