Teresa Netti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Teresa Netti has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- António Pinho Ramos
Centro de Biotecnologia Agrícola e Agro-Alimentar do Alentejo (CEBAL)/Instituto Politécnico de Beja (IPBeja), 7801-908 Beja, Portugal
2 shared publications - Aurelio Muttoni
Ecole Polytechnique Fédérale de Lausanne, Switzerland
2 shared publications - Dario Coronelli
Politecnico di Milano
2 shared publications - Georgios Tsionis
European Commission, Joint Research Centre (JRC), Ispra, Italy
2 shared publications - Marco Lamperti Tornaghi
European Commission Joint Research Centre Ispra, Ispra, Lombardy, Italy
2 shared publications - Brisid Isufi
NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
1 shared publication
Latest Publications
- Open Access
- 22 August 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (9) , 2299-2318
Seismic Performance of Strengthened Slab-Column Connections in a Full-Scale Test
Strengthening of flat slab-column connections to resist imposed lateral drifts is often required for older reinforced concrete structures in which the flat slabs were typically designed to resist gravity load only or have been designed for less stringent requirements. The complex stress state around the columns means that strong experimental evidence is required for the repair and strengthening techniques to be adopted with confidence in practice. Although a significant amount of research has been devoted to strengthening of slab-column connections, a series of limitations still remain. A thorough literature review revealed that only relatively thin and isolated specimens have been tested under seismic-type loading and realistic strengthening scenarios. To overcome these limitations, a full-scale two-story flat slab building specimen was tested at the European Commission’s Joint Research Centre – ELSA Laboratory in Ispra, Italy. This paper describes and analyzes the results obtained from the last of a series of phases, on repaired and strengthened internal and external slab-column connections using post-installed bolts. Compared with previous tests, the full-scale building specimen has a thicker slab (200 mm), realistic slab continuity conditions and the connections were strengthened after they suffered damage from gravity loading and previous lateral loading phases. The results show that post-installed bolts are efficient even under the described conditions (i.e. damaged and repaired specimens with realistic thickness), and punching shear failure was prevented in the strengthened connections.
- 22 August 2022
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 27 (9) , 2299-2318
Open AccessSeismic Performance of Strengthened Slab-Column Connections in a Full-Scale Test
Strengthening of flat slab-column connections to resist imposed lateral drifts is often required for older reinforced concrete structures in which the flat slabs were typically designed to resist gravity load only or have been designed for less stringent requirements. The complex stress state around the columns means that strong experimental evidence is required for the repair and strengthening techniques to be adopted with confidence in practice. Although a significant amount of research has been devoted to strengthening of slab-column connections, a series of limitations still remain. A thorough literature review revealed that only relatively thin and isolated specimens have been tested under seismic-type loading and realistic strengthening scenarios. To overcome these limitations, a full-scale two-story flat slab building specimen was tested at the European Commission’s Joint Research Centre – ELSA Laboratory in Ispra, Italy. This paper describes and analyzes the results obtained from the last of a series of phases, on repaired and strengthened internal and external slab-column connections using post-installed bolts. Compared with previous tests, the full-scale building specimen has a thicker slab (200 mm), realistic slab continuity conditions and the connections were strengthened after they suffered damage from gravity loading and previous lateral loading phases. The results show that post-installed bolts are efficient even under the described conditions (i.e. damaged and repaired specimens with realistic thickness), and punching shear failure was prevented in the strengthened connections.
- Open Access
- 1 September 2021
- Published by Elsevier in Engineering Structures
- Vol. 243
Testing of a full-scale flat slab building for gravity and lateral loads
- 1 September 2021
- Published by Elsevier in Engineering Structures
- Vol. 243
Open AccessTesting of a full-scale flat slab building for gravity and lateral loads