Ruikun Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ruikun Li has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Lisheng Wang
Shanghai Jiao Tong University
2 shared publications - Dahong Qian
Shanghai Jiao Tong University
1 shared publication Fuzhen Song
The International Peace Maternity and Child Health Hospital Shanghai Jiao Tong University School of Medicine Shanghai China
1 shared publication- Guanzhong Gong
Department of Radiation Physics, Shandong First Medical University Affiliated Cancer Hospital, Shandong Cancer Hospital and Institute, Jinan, 250117, China
1 shared publication - Guofu Zhang
Department of Radiology, the Obstetrics and Gynecology Hospital, Fudan University, P.R. China
1 shared publication - Huai Chen
Institute of Image Processing and Pattern Recognition, Department of Automation, Shanghai Jiao Tong University, Shanghai, China
1 shared publication
Latest Publications
- 24 April 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (1) , 494-504
A Hybrid Model for Fetal Growth Restriction Assessment by Automatic Placental Radiomics on T2‐Weighted MRI and Multifeature Fusion
Background: MRI‐based placental analyses have been used to improve fetal growth restriction (FGR) assessment by complementing ultrasound‐based measurements. However, these are still limited by time‐consuming manual annotation in MRI data and the lack of mother‐based information.Purpose: To develop and validate a hybrid model for accurate FGR assessment by automatic placental radiomics on T2‐weighted imaging (T2WI) and multifeature fusion.Study Type: Retrospective.Population: 274 pregnant women (29.5 4.0 years) from two centers were included and randomly divided into training (N = 119), internal test (N = 40), time‐independent validation (N = 43), and external validation (N = 72) sets.Field Strength/Sequence: 1.5‐T, T2WI half‐Fourier acquisition single‐shot turbo spin‐echo pulse sequence.Assessment: First, the placentas on T2WI were manually annotated, and a deep learning model was developed to automatically segment the placentas. Then, the radiomic features were extracted from the placentas and selected by three‐step feature selection. In addition, fetus‐based measurement features and mother‐based clinical features were obtained from ultrasound examinations and medical records, respectively. Finally, a hybrid model based on random forest was constructed by fusing these features, and further compared with models based on other machine learning methods and different feature combinations.Statistical Tests: The performances of placenta segmentation and FGR assessment were evaluated by Dice similarity coefficient (DSC) and the area under the receiver operating characteristic curve (AUROC), respectively. A P‐value <0.05 was considered statistically significant.Results: The placentas were automatically segmented with an average DSC of 90.0%. The hybrid model achieved an AUROC of 0.923, 0.931, and 0.880 on the internal test, time‐independent validation, and external validation sets, respectively. The mother‐based clinical features resulted in significant performance improvements for FGR assessment.Data Conclusion: The proposed hybrid model may be able to assess FGR with high accuracy. Furthermore, information complementation based on placental, fetal, and maternal features could also lead to better FGR assessment performance.Level of Evidence: 3.Technical Efficacy: Stage 2.
- 24 April 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (1) , 494-504
A Hybrid Model for Fetal Growth Restriction Assessment by Automatic Placental Radiomics on T2‐Weighted MRI and Multifeature Fusion
Background: MRI‐based placental analyses have been used to improve fetal growth restriction (FGR) assessment by complementing ultrasound‐based measurements. However, these are still limited by time‐consuming manual annotation in MRI data and the lack of mother‐based information.Purpose: To develop and validate a hybrid model for accurate FGR assessment by automatic placental radiomics on T2‐weighted imaging (T2WI) and multifeature fusion.Study Type: Retrospective.Population: 274 pregnant women (29.5 4.0 years) from two centers were included and randomly divided into training (N = 119), internal test (N = 40), time‐independent validation (N = 43), and external validation (N = 72) sets.Field Strength/Sequence: 1.5‐T, T2WI half‐Fourier acquisition single‐shot turbo spin‐echo pulse sequence.Assessment: First, the placentas on T2WI were manually annotated, and a deep learning model was developed to automatically segment the placentas. Then, the radiomic features were extracted from the placentas and selected by three‐step feature selection. In addition, fetus‐based measurement features and mother‐based clinical features were obtained from ultrasound examinations and medical records, respectively. Finally, a hybrid model based on random forest was constructed by fusing these features, and further compared with models based on other machine learning methods and different feature combinations.Statistical Tests: The performances of placenta segmentation and FGR assessment were evaluated by Dice similarity coefficient (DSC) and the area under the receiver operating characteristic curve (AUROC), respectively. A P‐value <0.05 was considered statistically significant.Results: The placentas were automatically segmented with an average DSC of 90.0%. The hybrid model achieved an AUROC of 0.923, 0.931, and 0.880 on the internal test, time‐independent validation, and external validation sets, respectively. The mother‐based clinical features resulted in significant performance improvements for FGR assessment.Data Conclusion: The proposed hybrid model may be able to assess FGR with high accuracy. Furthermore, information complementation based on placental, fetal, and maternal features could also lead to better FGR assessment performance.Level of Evidence: 3.Technical Efficacy: Stage 2.
- 25 January 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (5) , 3521-3531
MRI-based two-stage deep learning model for automatic detection and segmentation of brain metastases
Objectives To develop and validate a two-stage deep learning model for automatic detection and segmentation of brain metastases (BMs) in MRI images. Methods In this retrospective study, T1-weighted (T1) and T1-weighted contrast-enhanced (T1ce) MRI images of 649 patients who underwent radiotherapy from August 2019 to January 2022 were included. A total of 5163 metastases were manually annotated by neuroradiologists. A two-stage deep learning model was developed for automatic detection and segmentation of BMs, which consisted of a lightweight segmentation network for generating metastases proposals and a multi-scale classification network for false-positive suppression. Its performance was evaluated by sensitivity, precision, F1-score, dice, and relative volume difference (RVD). Results Six hundred forty-nine patients were randomly divided into training (n = 295), validation (n = 99), and testing (n = 255) sets. The proposed two-stage model achieved a sensitivity of 90% (1463/1632) and a precision of 56% (1463/2629) on the testing set, outperforming one-stage methods based on a single-shot detector, 3D U-Net, and nnU-Net, whose sensitivities were 78% (1276/1632), 79% (1290/1632), and 87% (1426/1632), and the precisions were 40% (1276/3222), 51% (1290/2507), and 53% (1426/2688), respectively. Particularly for BMs smaller than 5 mm, the proposed model achieved a sensitivity of 66% (116/177), far superior to one-stage models (21% (37/177), 36% (64/177), and 53% (93/177)). Furthermore, it also achieved high segmentation performance with an average dice of 81% and an average RVD of 20%. Conclusion A two-stage deep learning model can detect and segment BMs with high sensitivity and low volume error. Key Points • A two-stage deep learning model based on triple-channel MRI images identified brain metastases with 90% sensitivity and 56% precision. • For brain metastases smaller than 5 mm, the proposed two-stage model achieved 66% sensitivity and 22% precision. • For segmentation of brain metastases, the proposed two-stage model achieved a dice of 81% and a relative volume difference (RVD) of 20%.
- 25 January 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (5) , 3521-3531
MRI-based two-stage deep learning model for automatic detection and segmentation of brain metastases
Objectives To develop and validate a two-stage deep learning model for automatic detection and segmentation of brain metastases (BMs) in MRI images. Methods In this retrospective study, T1-weighted (T1) and T1-weighted contrast-enhanced (T1ce) MRI images of 649 patients who underwent radiotherapy from August 2019 to January 2022 were included. A total of 5163 metastases were manually annotated by neuroradiologists. A two-stage deep learning model was developed for automatic detection and segmentation of BMs, which consisted of a lightweight segmentation network for generating metastases proposals and a multi-scale classification network for false-positive suppression. Its performance was evaluated by sensitivity, precision, F1-score, dice, and relative volume difference (RVD). Results Six hundred forty-nine patients were randomly divided into training (n = 295), validation (n = 99), and testing (n = 255) sets. The proposed two-stage model achieved a sensitivity of 90% (1463/1632) and a precision of 56% (1463/2629) on the testing set, outperforming one-stage methods based on a single-shot detector, 3D U-Net, and nnU-Net, whose sensitivities were 78% (1276/1632), 79% (1290/1632), and 87% (1426/1632), and the precisions were 40% (1276/3222), 51% (1290/2507), and 53% (1426/2688), respectively. Particularly for BMs smaller than 5 mm, the proposed model achieved a sensitivity of 66% (116/177), far superior to one-stage models (21% (37/177), 36% (64/177), and 53% (93/177)). Furthermore, it also achieved high segmentation performance with an average dice of 81% and an average RVD of 20%. Conclusion A two-stage deep learning model can detect and segment BMs with high sensitivity and low volume error. Key Points • A two-stage deep learning model based on triple-channel MRI images identified brain metastases with 90% sensitivity and 56% precision. • For brain metastases smaller than 5 mm, the proposed two-stage model achieved 66% sensitivity and 22% precision. • For segmentation of brain metastases, the proposed two-stage model achieved a dice of 81% and a relative volume difference (RVD) of 20%.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (3) , 1251-1262
3D Graph-Connectivity Constrained Network for Hepatic Vessel Segmentation
Segmentation of hepatic vessels from 3D CT images is necessary for accurate diagnosis and preoperative planning for liver cancer. However, due to the low contrast and high noises of CT images, automatic hepatic vessel segmentation is a challenging task. Hepatic vessels are connected branches containing thick and thin blood vessels, showing an important structural characteristic or a prior: the connectivity of blood vessels. However, this is rarely applied in existing methods. In this paper, we segment hepatic vessels from 3D CT images by utilizing the connectivity prior. To this end, a graph neural network (GNN) used to describe the connectivity prior of hepatic vessels is integrated into a general convolutional neural network (CNN). Specifically, a graph attention network (GAT) is first used to model the graphical connectivity information of hepatic vessels, which can be trained with the vascular connectivity graph constructed directly from the ground truths. Second, the GAT is integrated with a lightweight 3D U-Net by an efficient mechanism called the plug-in mode, in which the GAT is incorporated into the U-Net as a multi-task branch and is only used to supervise the training procedure of the U-Net with the connectivity prior. The GAT will not be used in the inference stage, and thus will not increase the hardware and time costs of the inference stage compared with the U-Net. Therefore, hepatic vessel segmentation can be well improved in an efficient mode. Extensive experiments on two public datasets show that the proposed method is superior to related works in accuracy and connectivity of hepatic vessel segmentation.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (3) , 1251-1262
3D Graph-Connectivity Constrained Network for Hepatic Vessel Segmentation
Segmentation of hepatic vessels from 3D CT images is necessary for accurate diagnosis and preoperative planning for liver cancer. However, due to the low contrast and high noises of CT images, automatic hepatic vessel segmentation is a challenging task. Hepatic vessels are connected branches containing thick and thin blood vessels, showing an important structural characteristic or a prior: the connectivity of blood vessels. However, this is rarely applied in existing methods. In this paper, we segment hepatic vessels from 3D CT images by utilizing the connectivity prior. To this end, a graph neural network (GNN) used to describe the connectivity prior of hepatic vessels is integrated into a general convolutional neural network (CNN). Specifically, a graph attention network (GAT) is first used to model the graphical connectivity information of hepatic vessels, which can be trained with the vascular connectivity graph constructed directly from the ground truths. Second, the GAT is integrated with a lightweight 3D U-Net by an efficient mechanism called the plug-in mode, in which the GAT is incorporated into the U-Net as a multi-task branch and is only used to supervise the training procedure of the U-Net with the connectivity prior. The GAT will not be used in the inference stage, and thus will not increase the hardware and time costs of the inference stage compared with the U-Net. Therefore, hepatic vessel segmentation can be well improved in an efficient mode. Extensive experiments on two public datasets show that the proposed method is superior to related works in accuracy and connectivity of hepatic vessel segmentation.
- 8 December 2018
- Published by Association for Computing Machinery (ACM)
- p. 594-599
Open AccessPartsNet