Mengqiang Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mengqiang Xiao has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Meng Zhang
Department of Radiology, Zhuhai Hospital, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai City, Guangdong Province, China
13 shared publicationsJun Chen
Department of Radiology, Zhuhai Hospital, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai City, Guangdong Province, China
12 shared publicationsHongyi Li
Department of Radiology, Zhuhai Hospital, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai City, Guangdong Province, China
6 shared publicationsJingzhi Ye
Department of Radiology, Zhuhai Hospital, Guangdong Provincial Hospital of Traditional Chinese Medicine, 53 Jingle Road, Zhuhai City, Guangdong Province, China
6 shared publicationsFenghuan Lin
Department of Radiology, Zhuhai Hospital, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai City, Guangdong Province, China
5 shared publicationsJingfeng Liu
Department of Radiology, Zhuhai Hospital, Guangdong Provincial Hospital of Traditional Chinese Medicine, Zhuhai City, Guangdong Province, China
4 shared publications
Latest Publications
- 17 July 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (1) , 124-133
Diagnostic Accuracy of Ultra-Low Dose CT Compared to Standard Dose CT for Identification of Fresh Rib Fractures by Deep Learning Algorithm
The present study aimed to evaluate the diagnostic accuracy of ultra-low dose computed tomography (ULD-CT) compared to standard dose computed tomography (SD-CT) in discerning recent rib fractures using a deep learning algorithm detection of rib fractures (DLADRF). A total of 158 patients undergoing forensic diagnosis for rib fractures were included in this study: 50 underwent SD-CT, and 108 were assessed using ULD-CT. Junior and senior radiologists independently evaluated the images to identify and characterize the rib fractures. The sensitivity of rib fracture diagnosis by radiologists and radiologist + DLADRF was better using SD-CT than ULD-CT. However, the diagnosis sensitivity of DLADRF using ULD-CT alone was slightly more than SD-CT. Nonetheless, no substantial differences were observed in specificity, positive predictive value, and negative predictive value between SD-CT and ULD-CT by the same radiologist, radiologist + DLADRF, and DLADRF (P > 0.05). The area under the curve (AUC) of receiver operating characteristic indicated that senior radiologist + DLADRF was significantly better than senior and junior radiologists, junior radiologists + DLADRF, and DLADRF alone using SD-CT or ULD-CT (all P < 0.05). Also, junior radiologists + DLADRF was better with ULD-CT than senior and junior radiologists (P < 0.05). The AUC of the rib fracture diagnosed by senior radiologists did not differ from DLADRF using ULD-CT. Also, no significant differences were observed between junior + AI and senior and between junior and DLADRF using SD-CT. DLADRF enhanced the diagnostic performance of radiologists in detecting recent rib fractures. The diagnostic outcomes between SD-CT and ULD-CT across radiologists’ experience and DLADRF did not differ significantly.
- 17 July 2024
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (1) , 124-133
Diagnostic Accuracy of Ultra-Low Dose CT Compared to Standard Dose CT for Identification of Fresh Rib Fractures by Deep Learning Algorithm
The present study aimed to evaluate the diagnostic accuracy of ultra-low dose computed tomography (ULD-CT) compared to standard dose computed tomography (SD-CT) in discerning recent rib fractures using a deep learning algorithm detection of rib fractures (DLADRF). A total of 158 patients undergoing forensic diagnosis for rib fractures were included in this study: 50 underwent SD-CT, and 108 were assessed using ULD-CT. Junior and senior radiologists independently evaluated the images to identify and characterize the rib fractures. The sensitivity of rib fracture diagnosis by radiologists and radiologist + DLADRF was better using SD-CT than ULD-CT. However, the diagnosis sensitivity of DLADRF using ULD-CT alone was slightly more than SD-CT. Nonetheless, no substantial differences were observed in specificity, positive predictive value, and negative predictive value between SD-CT and ULD-CT by the same radiologist, radiologist + DLADRF, and DLADRF (P > 0.05). The area under the curve (AUC) of receiver operating characteristic indicated that senior radiologist + DLADRF was significantly better than senior and junior radiologists, junior radiologists + DLADRF, and DLADRF alone using SD-CT or ULD-CT (all P < 0.05). Also, junior radiologists + DLADRF was better with ULD-CT than senior and junior radiologists (P < 0.05). The AUC of the rib fracture diagnosed by senior radiologists did not differ from DLADRF using ULD-CT. Also, no significant differences were observed between junior + AI and senior and between junior and DLADRF using SD-CT. DLADRF enhanced the diagnostic performance of radiologists in detecting recent rib fractures. The diagnostic outcomes between SD-CT and ULD-CT across radiologists’ experience and DLADRF did not differ significantly.
- Open Access
- 21 March 2024
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 20, 1-10
Imaging Features and Misdiagnosis of Giant Cerebral Cavernous Malformations
Background:: While cerebral cavernous malformations (CCMs) have been extensively described, few reports have described the imaging appearance of giant CCMs (GCCMs). Objective:: To describe the imaging characteristics of GCCMs and study the reasons for preoperative misdiagnosis. Methods:: We retrospectively analyzed the data of 12 patients (5 men, 7 women; mean age, 35.23 ± 12.64 years) with histopathologically confirmed GCCMs. Two radiologists analyzed the CT (n = 12) and MRI (n = 10) features: location, number, size, shape, boundary, signal intensity, and enhancement. Results:: The sellar region, cerebral hemisphere, skull bone, and ventricle were involved in 5, 4, 2, and 1 patients, respectively. Three tumors were irregularly shaped, while nine were oval. Eleven lesions showed slightly high- and/or high-density on CT; 1 lesion appeared as a low-density cyst. Calcifications were found in 11 lesions. Four tumors showed uniform hypointensity on T1-weighted imaging (T1WI) and hyperintense signals on T2-weighted imaging (T2WI). Six tumors showed mixed low-, equal-, and high-intensity signals on T1WI and T2WI. Noticeable contrast enhancement and gradual strengthening were noted on T1WI. Ten lesions showed hemorrhage and hemosiderin deposition. The GCCMs were wrongly diagnosed as cartilage-derived tumors/ meningioma (3 patients); tumor and hematoma (2 patients each); and pituitary tumor/ meningioma, chondroma, chordoma, ependymoma, and macroadenoma (1 patient each). Conclusions:: GCCMs present as an oval mass with slightly high- and/or high-density calcifications on CT and show hemorrhage and hemosiderin accumulation on MRI. Therefore, slightly high- and/or high-density calcification and hemosiderin accumulation are critical clinical characteristics of GCCMs
- 21 March 2024
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 20, 1-10
Open AccessImaging Features and Misdiagnosis of Giant Cerebral Cavernous Malformations
Background:: While cerebral cavernous malformations (CCMs) have been extensively described, few reports have described the imaging appearance of giant CCMs (GCCMs). Objective:: To describe the imaging characteristics of GCCMs and study the reasons for preoperative misdiagnosis. Methods:: We retrospectively analyzed the data of 12 patients (5 men, 7 women; mean age, 35.23 ± 12.64 years) with histopathologically confirmed GCCMs. Two radiologists analyzed the CT (n = 12) and MRI (n = 10) features: location, number, size, shape, boundary, signal intensity, and enhancement. Results:: The sellar region, cerebral hemisphere, skull bone, and ventricle were involved in 5, 4, 2, and 1 patients, respectively. Three tumors were irregularly shaped, while nine were oval. Eleven lesions showed slightly high- and/or high-density on CT; 1 lesion appeared as a low-density cyst. Calcifications were found in 11 lesions. Four tumors showed uniform hypointensity on T1-weighted imaging (T1WI) and hyperintense signals on T2-weighted imaging (T2WI). Six tumors showed mixed low-, equal-, and high-intensity signals on T1WI and T2WI. Noticeable contrast enhancement and gradual strengthening were noted on T1WI. Ten lesions showed hemorrhage and hemosiderin deposition. The GCCMs were wrongly diagnosed as cartilage-derived tumors/ meningioma (3 patients); tumor and hematoma (2 patients each); and pituitary tumor/ meningioma, chondroma, chordoma, ependymoma, and macroadenoma (1 patient each). Conclusions:: GCCMs present as an oval mass with slightly high- and/or high-density calcifications on CT and show hemorrhage and hemosiderin accumulation on MRI. Therefore, slightly high- and/or high-density calcification and hemosiderin accumulation are critical clinical characteristics of GCCMs
- Open Access
- 29 August 2023
- Published by Hindawi Limited in Emergency Medicine International
- Vol. 2023, 1-8
Oblique Axis Rib Stretch and Curved Planar Reformats in Patients for Rib Fracture Detection and Characterization: Feasibility and Clinical Application
Objective. To assess the use of CT with oblique axis rib stretch (OARS) and curved planar reformats (CPRs) for rib fracture detection and characterization. Methods. A total of 108 forensically diagnosed patients with rib fractures were evaluated retrospectively. OARS and CPRs were independently used during the diagnosis in two groups. In each group, the final diagnosis was made after a junior radiologist’s initial diagnosis was reviewed by a senior radiologist. The images were evaluated for the presence and characterization of rib fractures. Results. A total of 2,592 ribs were analyzed, and 326 fractured ribs and 345 fracture sites were diagnosed using reference standard. Two groups of radiologists identified 331 and 333 fracture sites using the OARS method, 291 and 288 fracture sites using the CPRs method, and 274 fracture sites in forensically diagnosed patients (CR: conventional reconstruction), respectively; and all missed diagnoses were nondisplaced rib fractures. The ROC Az value of OARS1,2 was 0.98, which is higher than CPRs1,2 0.91, and CR 0.90 (all p < 0.01). The Az value for detecting rib fractures using CPRs1,2 and CR has no statistical difference ( p = 0.14 and 0.29). More misdiagnosed patients were found using CPRs1,2 (42 and 44 cases) than OARS1,2 (1 and 2 cases) and CR (2 cases). The displaced fracture detection ratio of all methods showed no difference. Conclusions. Doctors using the OARS method could improve diagnostic performance for detecting rib fractures without the requirement of specialized software and workstation when compared with CPRs.
- 29 August 2023
- Published by Hindawi Limited in Emergency Medicine International
- Vol. 2023, 1-8
Open AccessOblique Axis Rib Stretch and Curved Planar Reformats in Patients for Rib Fracture Detection and Characterization: Feasibility and Clinical Application
Objective. To assess the use of CT with oblique axis rib stretch (OARS) and curved planar reformats (CPRs) for rib fracture detection and characterization. Methods. A total of 108 forensically diagnosed patients with rib fractures were evaluated retrospectively. OARS and CPRs were independently used during the diagnosis in two groups. In each group, the final diagnosis was made after a junior radiologist’s initial diagnosis was reviewed by a senior radiologist. The images were evaluated for the presence and characterization of rib fractures. Results. A total of 2,592 ribs were analyzed, and 326 fractured ribs and 345 fracture sites were diagnosed using reference standard. Two groups of radiologists identified 331 and 333 fracture sites using the OARS method, 291 and 288 fracture sites using the CPRs method, and 274 fracture sites in forensically diagnosed patients (CR: conventional reconstruction), respectively; and all missed diagnoses were nondisplaced rib fractures. The ROC Az value of OARS1,2 was 0.98, which is higher than CPRs1,2 0.91, and CR 0.90 (all p < 0.01). The Az value for detecting rib fractures using CPRs1,2 and CR has no statistical difference ( p = 0.14 and 0.29). More misdiagnosed patients were found using CPRs1,2 (42 and 44 cases) than OARS1,2 (1 and 2 cases) and CR (2 cases). The displaced fracture detection ratio of all methods showed no difference. Conclusions. Doctors using the OARS method could improve diagnostic performance for detecting rib fractures without the requirement of specialized software and workstation when compared with CPRs.
- Open Access
- 28 February 2023
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 15 (2) , 32-41
Effects of combining multiple dose reduction techniques on coronary computed tomography angiography
Coronary computed tomography angiography (CCTA) is the preferred non-invasive examination method for coronary heart disease. However, the radiation from computed tomography has become a concern since public awareness of radiation hazards continue to increase. To explore the value of multiple dose reduction techniques for CCTA. Consecutive normal and overweight patients were prospectively divided into two groups: Group A1, patients who received multiple dose reduction scans (n = 82); and group A2, patients who received conventional scans (n = 39). The scan parameters for group A1 were as follows: Isocentric scan, tube voltage = 80 kV, and tube current control using 80% smart milliampere. The scan parameters for group A2 were as follows: Normal position, tube voltage = 100 kV, and smart milliampere. The average effective doses (EDs) for groups A1 and A2 were 1.13 ± 0.35 and 3.36 ± 1.30 mSv, respectively. There was a statistically significant difference in ED between the two groups (P < 0.01). Furthermore, noise was significantly lower, and both signal-to-noise ratio and contrast signal-to-noise ratio were higher in group A2 when compared to group A1 (P < 0.01). Moreover, the subjective image quality (IQ) scores were excellent in both groups, in which there was no signi ficant difference in subjective IQ score between the two groups (P = 0.12). Multiple dose reduction scan techniques can significantly decrease the ED of patients receiving CCTA examinations for clinical diagnosis.
- 28 February 2023
- Published by Baishideng Publishing Group Inc. in World Journal of Radiology
- Vol. 15 (2) , 32-41
Open AccessEffects of combining multiple dose reduction techniques on coronary computed tomography angiography
Coronary computed tomography angiography (CCTA) is the preferred non-invasive examination method for coronary heart disease. However, the radiation from computed tomography has become a concern since public awareness of radiation hazards continue to increase. To explore the value of multiple dose reduction techniques for CCTA. Consecutive normal and overweight patients were prospectively divided into two groups: Group A1, patients who received multiple dose reduction scans (n = 82); and group A2, patients who received conventional scans (n = 39). The scan parameters for group A1 were as follows: Isocentric scan, tube voltage = 80 kV, and tube current control using 80% smart milliampere. The scan parameters for group A2 were as follows: Normal position, tube voltage = 100 kV, and smart milliampere. The average effective doses (EDs) for groups A1 and A2 were 1.13 ± 0.35 and 3.36 ± 1.30 mSv, respectively. There was a statistically significant difference in ED between the two groups (P < 0.01). Furthermore, noise was significantly lower, and both signal-to-noise ratio and contrast signal-to-noise ratio were higher in group A2 when compared to group A1 (P < 0.01). Moreover, the subjective image quality (IQ) scores were excellent in both groups, in which there was no signi ficant difference in subjective IQ score between the two groups (P = 0.12). Multiple dose reduction scan techniques can significantly decrease the ED of patients receiving CCTA examinations for clinical diagnosis.
- Open Access
- 22 November 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-7
Comparing the effectiveness of 3D printing technology in the treatment of clavicular fracture between surgeons with different experiences
Purpose: This study aims to examine the use of 3D printing technology to treat clavicular fractures by skilled and inexperienced surgeons. Methods: A total of 80 patients with clavicle fractures (from February 2017 to May 2021) were enrolled in this study. Patients were divided randomly into four groups: group A: Patients underwent low-dose CT scans, and 3D models were printed before inexperienced surgeons performed surgeries; group B: Standard-dose CT were taken, and 3D models were printed before experienced surgeons performed surgeries; group C and D: Standard-dose CT scans were taken in both groups, and the operations were performed differently by inexperienced (group C) and experienced (group D) surgeons. This study documented the operation time, blood loss, incision length, and the number of intraoperative fluoroscopies. Results: No statistically significant differences were found in age, gender, fracture site, and fracture type (P value: 0.23–0.88). Group A showed shorter incision length and fewer intraoperative fluoroscopy times than groups C and D (P < 0.05). There were no significant differences in blood loss volume, incision length, and intraoperative fluoroscopy times between group A and group B (P value range: 0.11–0.28). The operation time of group A was no longer than those of groups C and D (P value range: 0.11 and 0.24). Conclusion: The surgical effectiveness of inexperienced surgeons who applied 3D printing technology before clavicular fracture operation was better than those of inexperienced and experienced surgeons who did not use preoperative 3D printing technology.
- 22 November 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-7
Open AccessComparing the effectiveness of 3D printing technology in the treatment of clavicular fracture between surgeons with different experiences
Purpose: This study aims to examine the use of 3D printing technology to treat clavicular fractures by skilled and inexperienced surgeons. Methods: A total of 80 patients with clavicle fractures (from February 2017 to May 2021) were enrolled in this study. Patients were divided randomly into four groups: group A: Patients underwent low-dose CT scans, and 3D models were printed before inexperienced surgeons performed surgeries; group B: Standard-dose CT were taken, and 3D models were printed before experienced surgeons performed surgeries; group C and D: Standard-dose CT scans were taken in both groups, and the operations were performed differently by inexperienced (group C) and experienced (group D) surgeons. This study documented the operation time, blood loss, incision length, and the number of intraoperative fluoroscopies. Results: No statistically significant differences were found in age, gender, fracture site, and fracture type (P value: 0.23–0.88). Group A showed shorter incision length and fewer intraoperative fluoroscopy times than groups C and D (P < 0.05). There were no significant differences in blood loss volume, incision length, and intraoperative fluoroscopy times between group A and group B (P value range: 0.11–0.28). The operation time of group A was no longer than those of groups C and D (P value range: 0.11 and 0.24). Conclusion: The surgical effectiveness of inexperienced surgeons who applied 3D printing technology before clavicular fracture operation was better than those of inexperienced and experienced surgeons who did not use preoperative 3D printing technology.
- Open Access
- 26 September 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (9) , e0275297
The clinical performance of ultra-low-dose shoulder CT scans: The assessment on image and physical 3D printing models
Objectives: Evaluation of the clinical performance of ultra-low-dose computed tomography (CT) images of the shoulder joint on image-based diagnosis and three-dimensional (3D) printing surgical planning. Materials and methods: A total of 93 patients with displaced shoulder fractures were randomly divided into standard-dose, low-dose, and ultra-low-dose groups. Three-dimensional printing models of all patients’ shoulder joints were fabricated. The subjective image quality and 3D-printing model were evaluated by two senior orthopedic surgeons who were blinded to any scanning setting. A 3-point scale system was used to quantitatively assess the image quality and 3D printing model, where more than 2 points meant adequate level for clinical application. Results: Compared with the standard dose protocol, ultra-low-dose technique reduced the radiation dose by 99.29% without loss of key image quality of fracture pattern. Regarding the subjective image quality, the assessment scores for groups of standard, low, and ultra-low doses were 3.00, 2.76, 2.00 points on scapula and humerus, and 3.00, 2.73, 2.44 points on clavicle. Scores of the three groups for the assessment of 3D printing models were 3.00, 2.80, 1.34 on scapula and humerus, and 3.00, 2.90, 2.06 on clavicle. In the ultra-low-dose group, 24 out of 33 (72.7%) 3D printing models of scapula and humerus received lower than 2 points of the evaluation score, while nearly 94% of the clavicle models reached the adequate level. Conclusion: An ultra-low-dose protocol is adequate for the diagnosis of either displaced or non-displaced fractures of the shoulder joint even though minor flaws of images are present. Three-dimensional printing models of shoulder joints created from ultra-low-dose CT scans can be used for surgical planning at specific bone like the clavicle but perform insufficiently in the overall surgical planning for shoulder injuries due to the significant geometric flaws.
- 26 September 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (9) , e0275297
Open AccessThe clinical performance of ultra-low-dose shoulder CT scans: The assessment on image and physical 3D printing models
Objectives: Evaluation of the clinical performance of ultra-low-dose computed tomography (CT) images of the shoulder joint on image-based diagnosis and three-dimensional (3D) printing surgical planning. Materials and methods: A total of 93 patients with displaced shoulder fractures were randomly divided into standard-dose, low-dose, and ultra-low-dose groups. Three-dimensional printing models of all patients’ shoulder joints were fabricated. The subjective image quality and 3D-printing model were evaluated by two senior orthopedic surgeons who were blinded to any scanning setting. A 3-point scale system was used to quantitatively assess the image quality and 3D printing model, where more than 2 points meant adequate level for clinical application. Results: Compared with the standard dose protocol, ultra-low-dose technique reduced the radiation dose by 99.29% without loss of key image quality of fracture pattern. Regarding the subjective image quality, the assessment scores for groups of standard, low, and ultra-low doses were 3.00, 2.76, 2.00 points on scapula and humerus, and 3.00, 2.73, 2.44 points on clavicle. Scores of the three groups for the assessment of 3D printing models were 3.00, 2.80, 1.34 on scapula and humerus, and 3.00, 2.90, 2.06 on clavicle. In the ultra-low-dose group, 24 out of 33 (72.7%) 3D printing models of scapula and humerus received lower than 2 points of the evaluation score, while nearly 94% of the clavicle models reached the adequate level. Conclusion: An ultra-low-dose protocol is adequate for the diagnosis of either displaced or non-displaced fractures of the shoulder joint even though minor flaws of images are present. Three-dimensional printing models of shoulder joints created from ultra-low-dose CT scans can be used for surgical planning at specific bone like the clavicle but perform insufficiently in the overall surgical planning for shoulder injuries due to the significant geometric flaws.
- Open Access
- 24 September 2022
- Published by Springer Nature in Insights into Imaging
- Vol. 13 (1) , 1-9
Feasibility study of three-dimensional printing knee model using the ultra-low-dose CT scan for preoperative planning and simulated surgery
Objective: To explore the feasibility of the three-dimensional printing (3DP) knee model using the ultra-low-dose computed tomography (CT) scan for preoperative planning and simulated surgery. Methods: Thirty-six patients were divided into the standard-dose protocol group (A) and ultra-low-dose protocol group (B). The anteroposterior diameter, left and right diameter of femur, anteroposterior diameter of tibial plateau (APTP), left and right diameter, distance from the intercondylar ridge to tibial tuberosity, lower femur angle, and upper tibial angle were measured on CT images. On the 3D printed knee joint model, Vernier calipers were used to measure: anteroposterior diameter, left and right diameter of the internal and external condyles of femur; left and right diameters, anteroposterior diameters of tibial plateau; upper and lower meridian, left and right diameters of patella. Results: With group A as reference, the effective radiation dose in group B was significantly reduced to 97.0% (36.4 ± 3.7 uSv and 1.1 ± 0.2 uSv, respectively). There was no difference in objective parameters for 3DP model (p = 0.31–0.84). None of the quantitative parameters of image quality showed significant difference (p = 0.11–0.96). Despite lower score of image quality and 3DP model in group B (3.0 ± 0.0 vs. 2.1 ± 0.2, 2.9 ± 0.3 vs. 2.2 ± 0.4; p < 0.05), the diagnostic performance was consistent in the two groups (all scores ≥ 2). Image quality and 3DP printed models were highly consistent (k = 0.97). Conclusions: Ultra-low-dose protocol reduces the radiation dose while maintaining the image quality of knee. It meets the requirement for 3DP model, internal fixation model selection, and simulated surgery.
- 24 September 2022
- Published by Springer Nature in Insights into Imaging
- Vol. 13 (1) , 1-9
Open AccessFeasibility study of three-dimensional printing knee model using the ultra-low-dose CT scan for preoperative planning and simulated surgery
Objective: To explore the feasibility of the three-dimensional printing (3DP) knee model using the ultra-low-dose computed tomography (CT) scan for preoperative planning and simulated surgery. Methods: Thirty-six patients were divided into the standard-dose protocol group (A) and ultra-low-dose protocol group (B). The anteroposterior diameter, left and right diameter of femur, anteroposterior diameter of tibial plateau (APTP), left and right diameter, distance from the intercondylar ridge to tibial tuberosity, lower femur angle, and upper tibial angle were measured on CT images. On the 3D printed knee joint model, Vernier calipers were used to measure: anteroposterior diameter, left and right diameter of the internal and external condyles of femur; left and right diameters, anteroposterior diameters of tibial plateau; upper and lower meridian, left and right diameters of patella. Results: With group A as reference, the effective radiation dose in group B was significantly reduced to 97.0% (36.4 ± 3.7 uSv and 1.1 ± 0.2 uSv, respectively). There was no difference in objective parameters for 3DP model (p = 0.31–0.84). None of the quantitative parameters of image quality showed significant difference (p = 0.11–0.96). Despite lower score of image quality and 3DP model in group B (3.0 ± 0.0 vs. 2.1 ± 0.2, 2.9 ± 0.3 vs. 2.2 ± 0.4; p < 0.05), the diagnostic performance was consistent in the two groups (all scores ≥ 2). Image quality and 3DP printed models were highly consistent (k = 0.97). Conclusions: Ultra-low-dose protocol reduces the radiation dose while maintaining the image quality of knee. It meets the requirement for 3DP model, internal fixation model selection, and simulated surgery.
- Open Access
- 17 July 2022
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 104 (7)
Imaging Features of Lymphoepithelial-Like Carcinoma of the Salivary Glands
Objective: Lymphoepithelial-like carcinoma of the salivary glands (LELCSG) is a rare tumour of unknown aetiology. No studies have reported the imaging features of primary LELCSG. Methods: The clinical information and imaging features of eight patients with LELCSG were reviewed. Computed tomography (n = 4 patients) and magnetic resonance imaging (n = 4 patients) features were analysed by two radiologists to identify the location, number, size, shape, boundary, signal intensity and enhancement of LELCSG. Results: The study included four women and four men, and the mean size of the tumours was 32.88 ± 3.41 mm (range, 27–38 mm). The tumours affected the parotid gland in six cases and the submandibular gland in two cases. The eight cases were evaluated by radiologists . All tumours were lobulated; three had clear edges and five had blurred edges. There was no necrosis in six tumours, while two tumours exhibited slight necrosis without bleeding. All eight tumours showed multiple nodular changes and extensive fusion. Four tumours with magnetic resonance imaging (MRI) were isointense or slightly hyperintense on T1-weighted imaging (T1WI) and obvious homogeneous enhancement on contrasted enhanced T1WI scan, while slightly hyperintense on T2-weighted imaging (T2WI). The other four lesions were isodense on computed tomography (CT) scan. The degree of enhancement varied among the eight tumours. The necrotic zones of the eight tumours did not exhibit any enhancement. Conclusions: LELCSG is a lobulated, multi-nodular tumour, with some fused nodules. LELCSG lesions showed isointensity or slight hyperintensity on T1WI MRI, slight hyperintensity on T2WI MRI and isodense on CT scan. Larger tumours may exhibit some necrosis, but the necrotic cysts were relatively rare. Uniform enhancement was observed in non-necrotic areas on enhanced CT and MRI scan. The multi-nodular feature may be valuable for diagnosis.
- 17 July 2022
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 104 (7)
Open AccessImaging Features of Lymphoepithelial-Like Carcinoma of the Salivary Glands
Objective: Lymphoepithelial-like carcinoma of the salivary glands (LELCSG) is a rare tumour of unknown aetiology. No studies have reported the imaging features of primary LELCSG. Methods: The clinical information and imaging features of eight patients with LELCSG were reviewed. Computed tomography (n = 4 patients) and magnetic resonance imaging (n = 4 patients) features were analysed by two radiologists to identify the location, number, size, shape, boundary, signal intensity and enhancement of LELCSG. Results: The study included four women and four men, and the mean size of the tumours was 32.88 ± 3.41 mm (range, 27–38 mm). The tumours affected the parotid gland in six cases and the submandibular gland in two cases. The eight cases were evaluated by radiologists . All tumours were lobulated; three had clear edges and five had blurred edges. There was no necrosis in six tumours, while two tumours exhibited slight necrosis without bleeding. All eight tumours showed multiple nodular changes and extensive fusion. Four tumours with magnetic resonance imaging (MRI) were isointense or slightly hyperintense on T1-weighted imaging (T1WI) and obvious homogeneous enhancement on contrasted enhanced T1WI scan, while slightly hyperintense on T2-weighted imaging (T2WI). The other four lesions were isodense on computed tomography (CT) scan. The degree of enhancement varied among the eight tumours. The necrotic zones of the eight tumours did not exhibit any enhancement. Conclusions: LELCSG is a lobulated, multi-nodular tumour, with some fused nodules. LELCSG lesions showed isointensity or slight hyperintensity on T1WI MRI, slight hyperintensity on T2WI MRI and isodense on CT scan. Larger tumours may exhibit some necrosis, but the necrotic cysts were relatively rare. Uniform enhancement was observed in non-necrotic areas on enhanced CT and MRI scan. The multi-nodular feature may be valuable for diagnosis.
- 19 May 2022
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 40 (10) , 1079-1086
The diagnostic performance of ultra-low-dose 320-row detector CT with different reconstruction algorithms on limb joint fractures in the emergency department
Background The aim of the study was to evaluate whether ultra-low-dose computed tomography (ULD-CT) could replace conventional-dose CT (CD-CT) for diagnosis of acute wrist, ankle, knee, and shoulder fractures in emergency departments (ED). Methods We developed CD-CT and ULD-CT scanning schemes for the various joints of the four limbs and scanned emergency patients prospectively. When performing CD-CT, a conventional bone reconstruction algorithm was used, while ULD-CT used both soft tissue and bone algorithms. A five-point scale was used to evaluate whether ULD-CT image quality affected surgical planning. The image quality and diagnostic performance of different types of scanned and reconstructed images for diagnosing fractures were evaluated and compared. Effective radiation dose of each group was calculated. Results Our study included 56 normal cases and 185 fracture cases. The combination of bone and soft tissue algorithms on ULD-CT can improve diagnostic performance, such that on ULD-CT, the sensitivity improved from 96.7% to 98.9%, specificity from 98.2% to 100%, positive predictive value from 99.4% to 100%, negative predictive value from 90.2% to 96.6% and diagnostic accuracy ranged from 97.5% to 99.1%. There were no statistically significant differences between ULD-CT and CD-CT on diagnostic performance (p values, 0.40–1.00). The radiation doses for ULD-CT protocols were only 3.0–7.7% of those for CD-CT protocols (all p < 0.01). Conclusions In the emergency department, the 320-row detector ULD-CT could replace CD-CT in the diagnosis of limb joint fractures. The combination of bone algorithm with soft tissue algorithm reconstruction can further improve the image quality and diagnostic performance.
- 19 May 2022
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 40 (10) , 1079-1086
The diagnostic performance of ultra-low-dose 320-row detector CT with different reconstruction algorithms on limb joint fractures in the emergency department
Background The aim of the study was to evaluate whether ultra-low-dose computed tomography (ULD-CT) could replace conventional-dose CT (CD-CT) for diagnosis of acute wrist, ankle, knee, and shoulder fractures in emergency departments (ED). Methods We developed CD-CT and ULD-CT scanning schemes for the various joints of the four limbs and scanned emergency patients prospectively. When performing CD-CT, a conventional bone reconstruction algorithm was used, while ULD-CT used both soft tissue and bone algorithms. A five-point scale was used to evaluate whether ULD-CT image quality affected surgical planning. The image quality and diagnostic performance of different types of scanned and reconstructed images for diagnosing fractures were evaluated and compared. Effective radiation dose of each group was calculated. Results Our study included 56 normal cases and 185 fracture cases. The combination of bone and soft tissue algorithms on ULD-CT can improve diagnostic performance, such that on ULD-CT, the sensitivity improved from 96.7% to 98.9%, specificity from 98.2% to 100%, positive predictive value from 99.4% to 100%, negative predictive value from 90.2% to 96.6% and diagnostic accuracy ranged from 97.5% to 99.1%. There were no statistically significant differences between ULD-CT and CD-CT on diagnostic performance (p values, 0.40–1.00). The radiation doses for ULD-CT protocols were only 3.0–7.7% of those for CD-CT protocols (all p < 0.01). Conclusions In the emergency department, the 320-row detector ULD-CT could replace CD-CT in the diagnosis of limb joint fractures. The combination of bone algorithm with soft tissue algorithm reconstruction can further improve the image quality and diagnostic performance.
- Open Access
- 15 April 2022
- Published by Springer Nature in The Egyptian Journal of Bronchology
- Vol. 16 (1) , 1-9
Ciliated muconodular papillary tumor of the lung: a case report and literature review
Background: Ciliated Muconodular Papillary Tumor (CMPT) was first reported in 2002, and fewer than 100 cases have since been reported. The prognosis after surgical resection is good, and recurrence has not been reported. However, it is easily misdiagnosed as adenocarcinoma. Summarizing the CT features of CMPT will help doctors better understand the disease. Case presentation: Here, we report a rare and interesting case of ciliated muconodular papillary tumor. A 6-mm diameter solid nodule with slight lobulation, short spines, and subpleural indentation. Patients with clinical diagnosis of high-risk subpleural nodule in the left lung underwent thoracoscopic surgery. Most CMPT cases lack specific clinical manifestations and were found incidentally on physical examination or during a workup for other diseases. The disease was diagnosed through CT and biopsy, and it responded well to surgery. Conclusions: This paper presents the detailed computed tomography features of CMPT to help prevent misdiagnosis. The typical manifestations of CMPT imaging as solid and partial nodules, nodules in subpleural or peripheral zones, and nodules contain cavities.
- 15 April 2022
- Published by Springer Nature in The Egyptian Journal of Bronchology
- Vol. 16 (1) , 1-9
Open AccessCiliated muconodular papillary tumor of the lung: a case report and literature review
Background: Ciliated Muconodular Papillary Tumor (CMPT) was first reported in 2002, and fewer than 100 cases have since been reported. The prognosis after surgical resection is good, and recurrence has not been reported. However, it is easily misdiagnosed as adenocarcinoma. Summarizing the CT features of CMPT will help doctors better understand the disease. Case presentation: Here, we report a rare and interesting case of ciliated muconodular papillary tumor. A 6-mm diameter solid nodule with slight lobulation, short spines, and subpleural indentation. Patients with clinical diagnosis of high-risk subpleural nodule in the left lung underwent thoracoscopic surgery. Most CMPT cases lack specific clinical manifestations and were found incidentally on physical examination or during a workup for other diseases. The disease was diagnosed through CT and biopsy, and it responded well to surgery. Conclusions: This paper presents the detailed computed tomography features of CMPT to help prevent misdiagnosis. The typical manifestations of CMPT imaging as solid and partial nodules, nodules in subpleural or peripheral zones, and nodules contain cavities.