HLHeiner Latus

Heiner Latus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Heiner Latus has a total of 196 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-Time Biventricular Pressure-Volume Loops During Percutaneous Pulmonary Valve Implantation in Patients With RVOT Dysfunction

    by Heiner Latus, Verena Schindler, Julie Cleuziou, Markus Khalil, Christian Jux, Christian Meierhofer, Daniel Tanase, Andreas Eicken, Peter Ewert, Stanimir Georgiev

    BACKGROUND: In patients with right ventricular (RV) outflow tract stenosis and pulmonary regurgitation (PR), percutaneous pulmonary valve implantation (PPVI) aims to preserve RV and left ventricular (LV) integrity and function. Our study aimed to assess acute changes in biventricular intrinsic myocardial function occurring with PPVI. METHODS: Twenty patients with RV outflow tract dysfunction (mean±1 SD; age, 23.0±10.9 years; mean peak echocardiographic RV outflow tract gradient, 64±25 mm Hg) underwent PPVI with biventricular assessment of pressure-volume loops using the conductance catheter technique during the same cardiac catheterization. Load-independent parameters of ventricular contractility (ventricular elastance) and ventricular compliance function, as well as pulmonary/systemic arterial elastance and ventriculoarterial coupling, were assessed before and directly after PPVI. Cardiac magnetic resonance for quantification of biventricular volumes, function, and PR was also performed. RESULTS: After PPVI, both RV ventricular elastance (median [interquartile range], 0.26 [0.16–0.83] to 0.19 [0.13–0.42] mm Hg/mL per m 2 ; P =0.029) and pulmonary systemic arterial elastance (0.32±0.20 to 0.25±0.19 mm Hg/mL per m 2 ; P P =0.76) did not change statistically significant. LV ventricular elastance (1.31±0.93 to 1.23±0.72 mm Hg/mL per m 2 ; P =0.68) and left ventriculoarterial coupling (0.75 [0.51–1.23] to 0.82 [0.53–1.10]; P =0.98) were not affected by PPVI although systemic arterial elastance increased significantly (0.83±0.26 to 0.90±0.34 mm Hg/mL per m 2 ; P =0.032). Both RV ( P =0.37) and LV ( P =0.20) compliance showed no significant change after PPVI. Patients with relevant PR (≥25%; n=10) had lower RV ventricular elastance ( P =0.043) before and higher LV compliance ( P =0.010) after PPVI compared with patients with minor PR (<25%; n=10), whereas ventriculoarterial coupling was similar between the 2 groups. CONCLUSIONS: Acute reduction of RV overload by PPVI is accompanied by an instantaneous decline in RV contractility with persistent and inefficient ventriculoarterial coupling. The LV adequately adapts to an increase in pre- and post-load with nonsignificant changes in LV intrinsic function and ventriculoarterial coupling. The relevance of these response patterns on long-term biventricular remodeling requires further investigation.

  • Open Access

    The changing landscape of multimodality imaging in congenital heart disease: white paper

    by G Di Salvo, J Sabatino, S V Babu-Narayan, A Arvanitaki, B Bonello, A Van De Bruaene, M Cantinotti, L Dos Subira, F Raimondi, T Bharucha, et al.

    The congenital heart disease (CHD) population has seen substantial growth due to advancements in paediatric cardiac care, cardiothoracic surgery, anaesthesia, and intensive care. Although improved surgical interventions have enhanced survival rates for even the most severe defects, such as hypoplastic left heart syndrome, most CHD patients remain palliated rather than cured, requiring lifelong expert care. With increasing survival, new challenges emerge in managing the ageing CHD population, particularly regarding changing medical, psychosocial needs, and the evolving epidemiology of CHD. Imaging plays a pivotal role in CHD care, offering precise anatomical and physiological insights necessary for effective management and risk stratification. The European Association of Cardiovascular Imaging (EACVI) established a shared interest group (SIG) to improve imaging standardization, promote education, and foster research for CHD patients. Multimodality imaging, including echocardiography, cardiovascular magnetic resonance (CMR), and computed tomography (CT), is critical in guiding interventions and improving outcomes. The SIG also addresses gaps in education, research, and global healthcare disparities, ensuring a collaborative and systematic approach to CHD care. Advances in imaging technology, genetic research, and tissue engineering hold promise for further improving the longevity and quality of life for CHD patients in the future.


  • Open Access

    Clinical impact of novel cardiovascular magnetic resonance technology on patients with congenital heart disease: a scientific statement of the Association for European Pediatric and Congenital Cardiology and the European Association of Cardiovascular Imaging of the European Society of Cardiology

    by Inga Voges, Francesca Raimondi, Colin J McMahon, Lamia Ait-Ali, Sonya V Babu-Narayan, René M Botnar, Barbara Burkhardt, Dominik D Gabbert, Lars Grosse-Wortmann, Hosan Hasan, et al.

    Cardiovascular magnetic resonance (CMR) imaging is recommended in patients with congenital heart disease (CHD) in clinical practice guidelines as the imaging standard for a large variety of diseases. As CMR is evolving, novel techniques are becoming available. Some of them are already used clinically, whereas others still need further evaluation. In this statement, the authors give an overview of relevant new CMR techniques for the assessment of CHD. Studies with reference values for these new techniques are listed in the Supplementary data online, supplement.


  • Open Access

    Left Ventricular Physiology and Ventricular‐Vascular Interactions in Young Patients After Heart Transplantation

    by Heiner Latus, Ramona Raap, Karin Klingel, Christoph Happel, Axel Moysich, Markus Khalil, Gunter Kerst, Jakob Milla, Susanne Skrzypek, Josef Thul, et al.

    Background: In patients after heart transplantation, systemic arterial hypertension and enhanced central aortic stiffness contribute to increased ventricular afterload, which might lead to graft dysfunction. The aim of our study was to characterize systemic arterial elastance and its impact on left ventricular function and ventriculo‐arterial coupling in a cohort of children, adolescents, and young adults after heart transplantation using invasive conductance catheter technique. Methods and Results: Thirty patients who had heart transplants (age, 20.0±6.5 years, 7 female) underwent invasive cardiac catheterization including pressure‐volume loop analysis. Load‐independent parameters of systolic (ventricular elastance [Ees]) and diastolic (ventricular compliance) function as well as systemic arterial elastance (Ea, end‐systolic pressure/stroke volume) and ventriculo‐arterial coupling (Ea/Ees) were assessed at baseline level and during dobutamine infusion (10 μg/kg/min). Ees showed an appropriate increase under inotropic stimulation from 0.43 (0.11–2.52) to 1.00 (0.20–5.10) mm Hg/mL/m 2 ( P 2 to 0.12±0.07 mm Hg/mL/m 2 ; P =0.10). Ventriculo‐arterial coupling Ea/Ees was abnormal at rest and did not improve significantly under dobutamine (1.7 [0.6–6.7] to 1.3 [0.5–4.9], P =0.70) due to a simultaneous rise in Ea from 0.71 (0.37–2.82) to 1.10 (0.52–4.03) mm Hg/mL/m 2 ( P <0.0001). Both Ees and ventricular compliance were significantly associated with Ea at baseline and under dobutamine infusion. Conclusions: Patients who underwent heart transplantation show impaired ventriculo‐arterial coupling at rest and under inotropic stimulation despite preserved left ventricular contractile reserve. An abnormal response in vascular function resulting in increased afterload seems to represent an important factor that may play a role for the development of late graft failure.


  • Open Access

    Family screening of hypertrophic cardiomyopathy in children: a case report

    by Inga Voges, Heiner Latus

    Paediatric hypertrophic cardiomyopathy (HCM) caused by sarcomere protein gene mutations is more common than previously thought. We present the case of a 9-year-old boy that was diagnosed with HCM during family screening. We present a case of a 9-year-old boy with a family history of sarcomeric HCM who was diagnosed with hypertrophic obstructive cardiomyopathy (HOCM) during clinical screening. Echocardiography and cardiovascular magnetic resonance imaging revealed asymmetric left ventricular hypertrophy with a maximum wall thickness of 18–19 mm. Cardiovascular magnetic resonance late gadolinium enhancement imaging showed patchy fibrosis within the area of maximum wall thickness. Genetic testing confirmed the presence of the familial mutation in the MYL2 gene. The patient was started on bisoprolol. Furthermore, risk stratification was performed and a recommendation for implantable cardioverter-defibrillator implantation was made. This case demonstrates that significant HCM can already start in childhood and discusses the recommendations for family screening on the basis of recently published studies and the present European Society of Cardiology guideline.


  • Open Access

    Impact of Right Ventricular Pressure Load After Repair of Tetralogy of Fallot

    by Heiner Latus, Jana Stammermann, Inga Voges, Birgit Waschulzik, Matthias Gutberlet, Gerhard‐Paul Diller, Dietmar Schranz, Peter Ewert, Philipp Beerbaum, Titus Kühne, et al.

    Background: Right ventricular outflow tract (RVOT) stenosis after repair of tetralogy of Fallot has been linked with favorable right ventricular remodeling but adverse outcomes. The aim of our study was to assess the hemodynamic impact and prognostic relevance of right ventricular pressure load in this population. Methods and Results: A total of 296 patients with repaired tetralogy of Fallot (mean age, 17.8±7.9 years) were included in a prospective cardiovascular magnetic resonance multicenter study. Myocardial strain was quantified by feature tracking technique at study entry. Follow‐up, including the need for pulmonary valve replacement, was assessed. The combined end point consisted of ventricular tachycardia and cardiac death. A higher echocardiographic RVOT peak gradient was significantly associated with smaller right ventricular volumes and less pulmonary regurgitation, but lower biventricular longitudinal strain. During a follow‐up of 10.1 (0.1–12.9) years, the primary end point was reached in 19 of 296 patients (cardiac death, n=6; sustained ventricular tachycardia, n=2; and nonsustained ventricular tachycardia, n=11). A higher RVOT gradient was associated with the combined outcome (hazard ratio [HR], 1.03; 95% CI, 1.00–1.06; P =0.026), and a cutoff gradient of ≥25 mm Hg was predictive for cardiovascular events (HR, 3.69; 95% CI, 1.47–9.27; P =0.005). In patients with pulmonary regurgitation ≥25%, a mild residual RVOT gradient (15–30 mm Hg) was not associated with a lower risk for pulmonary valve replacement. Conclusions: Higher RVOT gradients were associated with less pulmonary regurgitation and smaller right ventricular dimensions but were related to reduced biventricular strain and emerged as univariate predictors of adverse events. Mild residual pressure gradients did not protect from pulmonary valve replacement. These results may have implications for the indication for RVOT reintervention in this population.


  • Open Access

    Exercise-dependent changes in ventricular–arterial coupling and aortopulmonary collateral flow in Fontan patients: a real-time CMR study

    by Heiner Latus, Lucas Hofmann, Kerstin Gummel, Markus Khalil, Can Yerebakan, Birgit Waschulzik, Dietmar Schranz, Inga Voges, Christian Jux, Bettina Reich

    Inefficient ventricular–arterial (V–A) coupling has been described in Fontan patients and may result in adverse haemodynamics. A varying amount of aortopulmonary collateral (APC) flow is also frequently present that increases volume load of the single ventricle. The aim of the study was to assess changes in V–A coupling and APC flow during exercise CMR. Eighteen Fontan patients (age 24 ± 3 years) and 14 controls (age 23 ± 4 years) underwent exercise CMR using a cycle ergometer. Ventricular volumetry and flow measurements in the ascending aorta (AAO), inferior (IVC), and superior (SVC) vena cava were assessed using real-time sequences during stepwise increases in work load. Measures of systemic arterial elastance Ea, ventricular elastance Ees, and V–A coupling (Ea/Ees) were assessed. APC flow was quantified as AAO − (SVC + IVC). Ea remained unchanged during all levels of exercise in both groups (P = 0.39 and P = 0.11). Ees increased in both groups (P = 0.001 and P < 0.001) with exercise but was lower in the Fontan group (P = 0.04). V–A coupling was impaired in Fontan patients at baseline (P = 0.04). Despite improvement during exercise (P = 0.002) V–A coupling remained impaired compared with controls (P = 0.001). Absolute APC flow in Fontan patients did not change during exercise even at maximum work load (P = 0.98). Inefficient V–A coupling was already present at rest in Fontan patients and aggravated during exercise due to a limited increase in ventricular contractility which demonstrates the importance of a limited functional reserve of the single ventricle. APC flow remained unchanged suggesting no further increase in volume load during exercise.


  • Open Access

    Aortic diameter assessment by cardiovascular magnetic resonance: do we really need contrast enhanced images?

    by Irene Ferrari, Nerejda Shehu, Naira Mkrtchyan, Heiner Latus, Heiko Stern, Stefan Martinoff, Peter Ewert, Christian Meierhofer

    Aortic diameter assessment by cardiovascular magnetic resonance: do we really need contrast enhanced images? Irene Ferrari, Nerejda Shehu, Naira Mkrtchyan, Heiner Latus, Heiko Stern, Stefan Martinoff, Peter Ewert, Christian Meierhofer


  • Open Access

    Favorable Atrial Remodeling After Percutaneous Pulmonary Valve Implantation and Its Association With Changes in Exercise Capacity and Right Ventricular Function

    by Heiner Latus, Danik Born, Nerejda Shehu, Heiko Stern, Alfred Hager, Stainimir Georgiev, Daniel Tanase, Christian Meierhofer, Peter Ewert, Andreas Eicken, et al.

    Background: Right atrial (RA) dilatation and impaired right ventricular (RV) filling are common in patients with RV outflow tract dysfunction. We aimed to study potential correlations between atrial function with clinically relevant hemodynamic parameters and to assess the predictive impact of atrial performance on the recovery of exercise capacity and RV pump function after percutaneous pulmonary valve implantation (PPVI). Methods and Results: Altogether, 105 patients with right ventricular outflow tract dysfunction (median age at PPVI, 19.2 years; range, 6.2–53.4 years) who underwent cardiac magnetic resonance imaging before and 6 months after PPVI were included. RA and left atrial maximal and minimal volumes as well as atrial passive and active emptying function were assessed from axial cine slices. RA emptying function was inversely related to invasive RV end‐diastolic pressure, and RA passive emptying correlated significantly with peak oxygen uptake. After PPVI, a significant decrease in RA minimum volume was observed, whereas RA passive emptying function improved, and RA active emptying function decreased significantly. Patients with predominant right ventricular outflow tract stenosis showed more favorable changes in RA active and left atrial passive emptying than those with primary volume overload. None of the RA and left atrial emptying parameters was predictive for recovery of peak oxygen uptake or RV ejection fraction. Conclusions: In patients with right ventricular outflow tract dysfunction, impaired RA emptying assessed by cardiac magnetic resonance imaging was associated with increased RV filling pressures and lower exercise capacity. PPVI leads to a reduction in RA size and improved passive RA emptying function. However, RA function was not associated with improved exercise performance and RV pump function.