M. Vishnukumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
M. Vishnukumar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Arasappan Rajesh Kannan
Department of Mechanical Engineering, Incheon National University, Incheon 22012, Republic of Korea
1 shared publication - Channabasavanna Gurupadappa
Department of Mechanical Engineering, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru 570006, Karnataka, India
1 shared publication - Jonghun Yoon
Department of Mechanical Engineering, Hanyang University, Ansan-si, Republic of Korea
1 shared publication - Nallathambi Siva Shanmugam
National Institute of Technology
1 shared publication - Than Trong Khanh Dat
Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City 700000, Vietnam
1 shared publication - V. Rajkumar
Department of Mechanical Engineering, Coimbatore Institute of Engineering and Technology, Coimbatore 641109, Tamil Nadu, India
1 shared publication
Latest Publications
- Open Access
Microstructure, Mechanical Properties and Corrosion Performance of Laser-Welded NiTi Shape Memory Alloy in Simulated Body Fluid
Laser-welding is a promising technique for welding NiTi shape memory alloys with acceptable tensile strength and comparable corrosion performance for biomedical applications. The microstructural characteristics and localized corrosion behavior of NiTi alloys in a simulated body fluid (SBF) environment are evaluated. A microstructural examination indicated the presence of fine and equiaxed grains with a B2 austenite phase in the base metal (BM), while the weld metal (WM) had a coarse dendritic microstructure with intermetallic precipitates including Ti2Ni and Ni4Ti3. The hardness decreased from the BM to the WM, and the average hardness for the BM was 352 ± 5 HV, while it ranged between 275 and 307 HV and 265 and 287 HV for the HAZ and WM, respectively. Uni-axial tensile tests revealed a substantial decrease in the tensile strength of NiTi WM (481 ± 19 MPa), with a reduced joint efficiency of 34%. The localized corrosion performance of NiTi BM was superior to the WM, with electrochemical test responses indicating a pitting potential and low corrosion rate in SBF environments. The corrosion rate of the NiTi BM and WM was 0.048 ± 0.0018 mils per year (mpy) and 0.41 ± 0.019 mpy, respectively. During welding, NiTi’s strength and biocompatibility properties changed due to the alteration in microstructure and formation of intermetallic phases as a result of Ti enrichment. The performance and safety of welded medical devices may be impacted during welding, and it is essential to preserve the biocompatibility of NiTi components for biomedical applications.
Open AccessMicrostructure, Mechanical Properties and Corrosion Performance of Laser-Welded NiTi Shape Memory Alloy in Simulated Body Fluid
Laser-welding is a promising technique for welding NiTi shape memory alloys with acceptable tensile strength and comparable corrosion performance for biomedical applications. The microstructural characteristics and localized corrosion behavior of NiTi alloys in a simulated body fluid (SBF) environment are evaluated. A microstructural examination indicated the presence of fine and equiaxed grains with a B2 austenite phase in the base metal (BM), while the weld metal (WM) had a coarse dendritic microstructure with intermetallic precipitates including Ti2Ni and Ni4Ti3. The hardness decreased from the BM to the WM, and the average hardness for the BM was 352 ± 5 HV, while it ranged between 275 and 307 HV and 265 and 287 HV for the HAZ and WM, respectively. Uni-axial tensile tests revealed a substantial decrease in the tensile strength of NiTi WM (481 ± 19 MPa), with a reduced joint efficiency of 34%. The localized corrosion performance of NiTi BM was superior to the WM, with electrochemical test responses indicating a pitting potential and low corrosion rate in SBF environments. The corrosion rate of the NiTi BM and WM was 0.048 ± 0.0018 mils per year (mpy) and 0.41 ± 0.019 mpy, respectively. During welding, NiTi’s strength and biocompatibility properties changed due to the alteration in microstructure and formation of intermetallic phases as a result of Ti enrichment. The performance and safety of welded medical devices may be impacted during welding, and it is essential to preserve the biocompatibility of NiTi components for biomedical applications.