Pablo Santafé-Gabarda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pablo Santafé-Gabarda has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Ferrero
Consejo Superior de Investigaciones Científicas
8 shared publications - Joaquín Campos
Instituto de Óptica “Daza de Valdés” (IO) CSIC
6 shared publications - Alfred Schirmacher
Physikalisch-Technische Bundesanstalt (PTB) Braunschweig und Berlin Bundesallee 100 38116 Braunschweig Germany
3 shared publications - Lou Gevaux
Laboratoire Commun de Métrologie LNE-Cnam (EA 2367), Conservatoire National des Arts et Métiers, 93210 Saint Denis, France
3 shared publications - Ellie Molloy
Measurement Standards Laboratory of New Zealand, 69 Gracefield Rd, Lower Hutt 5010, New Zealand
2 shared publications - Gaël Obein
Conservatoire National des Arts et Métiers, France
2 shared publications
Latest Publications
- Open Access
- 29 January 2026
- Published by Elsevier in Building and Environment
- Vol. 292
Evaluation of angular dependence of spectral reflectance and transmittance of glazing systems for improving energy efficiency in buildings
- 29 January 2026
- Published by Elsevier in Building and Environment
- Vol. 292
Open AccessEvaluation of angular dependence of spectral reflectance and transmittance of glazing systems for improving energy efficiency in buildings
- Open Access
- 22 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 044001
Accurate characterisation of optical diffuse transmission—primary facility and extension to translucent samples
To perform accurate, high-quality and traceable measurement of optical diffuse transmission, which is quantified using the bidirectional transmittance distribution function (BTDF), a new primary facility has been developed at the Physikalisch–Technische Bundesanstalt (PTB), the German metrology institute. This newly developed reference facility will complement the available calibration services and research facilities at PTB for regular reflectance and transmittance and diffuse reflectance. The performance of the new BTDF setup has been investigated in an internal comparison, where consistency of the results was achieved. A thorough uncertainty analysis results in a minimum combined standard (k = 1) uncertainty of about 0.8 %. Research on the accurate characterisation of the BTDF of samples with non-negligible lateral scattering is being carried out on this new setup. Some first results have shown that the measured BTDF value depends on the applied irradiation area size. An empirical model has been found to describe the diffuse transmission of such translucent samples with different scattering parameters.
- 22 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 044001
Open AccessAccurate characterisation of optical diffuse transmission—primary facility and extension to translucent samples
To perform accurate, high-quality and traceable measurement of optical diffuse transmission, which is quantified using the bidirectional transmittance distribution function (BTDF), a new primary facility has been developed at the Physikalisch–Technische Bundesanstalt (PTB), the German metrology institute. This newly developed reference facility will complement the available calibration services and research facilities at PTB for regular reflectance and transmittance and diffuse reflectance. The performance of the new BTDF setup has been investigated in an internal comparison, where consistency of the results was achieved. A thorough uncertainty analysis results in a minimum combined standard (k = 1) uncertainty of about 0.8 %. Research on the accurate characterisation of the BTDF of samples with non-negligible lateral scattering is being carried out on this new setup. Some first results have shown that the measured BTDF value depends on the applied irradiation area size. An empirical model has been found to describe the diffuse transmission of such translucent samples with different scattering parameters.
- 22 May 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (16) , 4317-4331
Digitizing translucent object appearance by validating computed optical properties
The optical properties available for an object are most often fragmented and insufficient for photorealistic rendering of the object. We propose a procedure for digitizing a translucent object with sufficient information for predictive rendering of its appearance. Based on object material descriptions, we compute optical properties and validate or adjust this object appearance model based on comparison of simulation with spectrophotometric measurements of the bidirectional scattering-surface reflectance distribution function (BSSRDF). To ease this type of comparison, we provide an efficient simulation tool that computes the BSSRDF for a particular light-view configuration. Even with just a few configurations, the localized lighting in BSSRDF measurements is useful for assessing the appropriateness of computed or otherwise acquired optical properties. To validate an object appearance model in a more common lighting environment, we render the appearance of the obtained digital twin and assess the photorealism of our renderings through pixel-by-pixel comparison with photographs of the physical object.
- 22 May 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (16) , 4317-4331
Digitizing translucent object appearance by validating computed optical properties
The optical properties available for an object are most often fragmented and insufficient for photorealistic rendering of the object. We propose a procedure for digitizing a translucent object with sufficient information for predictive rendering of its appearance. Based on object material descriptions, we compute optical properties and validate or adjust this object appearance model based on comparison of simulation with spectrophotometric measurements of the bidirectional scattering-surface reflectance distribution function (BSSRDF). To ease this type of comparison, we provide an efficient simulation tool that computes the BSSRDF for a particular light-view configuration. Even with just a few configurations, the localized lighting in BSSRDF measurements is useful for assessing the appropriateness of computed or otherwise acquired optical properties. To validate an object appearance model in a more common lighting environment, we render the appearance of the obtained digital twin and assess the photorealism of our renderings through pixel-by-pixel comparison with photographs of the physical object.
- Open Access
- 7 May 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035006
Survey of bidirectional transmittance distribution function measurement facilities by multilateral scale comparisons
In recent years, a growing demand for the capability of performing accurate measurements of the bidirectional transmittance distribution function (BTDF) has been observed in industry, research and development, and aerospace applications. However, there exists no calibration and measurement capabilities-entry for BTDF in the database of the Bureau International des Poids et Mesures and to date no BTDF comparison has been conducted between different national metrology institutes (NMIs) or designated institutes (DIs). As a first step to a possible future key comparison and to test the existing capabilities of determining this measurand, two interlaboratory comparisons were performed. In comparison one, five samples of three different types of optical transmissive diffusers were measured by five NMIs and one DI. By specific sample choice, the focus for this study lay more on orientation-dependent scatter properties. In comparison two, where one NMI, one DI, one university, and three industrial partners investigated their measurement capabilities, the dependence on the orientation was not assessed, but two additional samples of the same material and different thickness were measured. Results of the two comparisons are presented, giving a good overview of existing experimental solutions, and showing specific sample-related problems to be solved for improved future BTDF measurements.
- 7 May 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (3) , 035006
Open AccessSurvey of bidirectional transmittance distribution function measurement facilities by multilateral scale comparisons
In recent years, a growing demand for the capability of performing accurate measurements of the bidirectional transmittance distribution function (BTDF) has been observed in industry, research and development, and aerospace applications. However, there exists no calibration and measurement capabilities-entry for BTDF in the database of the Bureau International des Poids et Mesures and to date no BTDF comparison has been conducted between different national metrology institutes (NMIs) or designated institutes (DIs). As a first step to a possible future key comparison and to test the existing capabilities of determining this measurand, two interlaboratory comparisons were performed. In comparison one, five samples of three different types of optical transmissive diffusers were measured by five NMIs and one DI. By specific sample choice, the focus for this study lay more on orientation-dependent scatter properties. In comparison two, where one NMI, one DI, one university, and three industrial partners investigated their measurement capabilities, the dependence on the orientation was not assessed, but two additional samples of the same material and different thickness were measured. Results of the two comparisons are presented, giving a good overview of existing experimental solutions, and showing specific sample-related problems to be solved for improved future BTDF measurements.
- Open Access
- 2 February 2024
- Published by IOP Publishing in Journal of Optics
- Vol. 26 (3) , 035601
Development and comparison of primary facilities for traceable BSSRDF measurements
The bidirectional scattering-surface reflectance distribution function (BSSRDF) describes the radiance originated by the volume scattering and the surface reflectance of any position on the surface of a sample, when it is directionally irradiated at any other position. The present state of the technology for appearance rendering requires a more detailed physical description of translucent objects by traceable measurements of the BSSRDF. This work presents two primary facilities developed for traceable BSSRDF measurements by different measuring approaches. Their results on the same translucent samples have been compared and the achieved BSSRDF scale has been transferred to a commercial measuring system. This study highlights the problems of the different measuring instrument designs and provides the scientific community with more knowledge on the measurement of the BSSRDF, which will be crucial for future works on material appearance.
- 2 February 2024
- Published by IOP Publishing in Journal of Optics
- Vol. 26 (3) , 035601
Open AccessDevelopment and comparison of primary facilities for traceable BSSRDF measurements
The bidirectional scattering-surface reflectance distribution function (BSSRDF) describes the radiance originated by the volume scattering and the surface reflectance of any position on the surface of a sample, when it is directionally irradiated at any other position. The present state of the technology for appearance rendering requires a more detailed physical description of translucent objects by traceable measurements of the BSSRDF. This work presents two primary facilities developed for traceable BSSRDF measurements by different measuring approaches. Their results on the same translucent samples have been compared and the achieved BSSRDF scale has been transferred to a commercial measuring system. This study highlights the problems of the different measuring instrument designs and provides the scientific community with more knowledge on the measurement of the BSSRDF, which will be crucial for future works on material appearance.
- 11 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (26) , 43686-43689
Primary facility for traceable measurement of BSSRDF: erratum
An erratum is presented to correct the measurement equation used for the calculation of the BSSRDF in our manuscript [ Opt. Express 29 (21), 34175 (2021)10.1364/OE.439108 ]. This correction affects slightly the results showed in Figs. 7 and 8 of the primary manuscript, so they are replaced by Fig. S1 and Fig. S2, respectively, of the current erratum. The discussion on the results of Fig. 7 of the primary manuscript is completely valid also for the new results, but a slightly different discussion is given on the new results showed in Fig. S2. Nevertheless, the conclusions of the original manuscript are not affected at all.
- 11 December 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (26) , 43686-43689
Primary facility for traceable measurement of BSSRDF: erratum
An erratum is presented to correct the measurement equation used for the calculation of the BSSRDF in our manuscript [ Opt. Express 29 (21), 34175 (2021)10.1364/OE.439108 ]. This correction affects slightly the results showed in Figs. 7 and 8 of the primary manuscript, so they are replaced by Fig. S1 and Fig. S2, respectively, of the current erratum. The discussion on the results of Fig. 7 of the primary manuscript is completely valid also for the new results, but a slightly different discussion is given on the new results showed in Fig. S2. Nevertheless, the conclusions of the original manuscript are not affected at all.
- 21 April 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (13) , 3320-3329
Intercomparison of bidirectional reflectance distribution function measurements at in- and out-of-plane geometries
In recent years, there has been a growing interest in the measurements of the bidirectional reflectance distribution function (BRDF) in industry and research and development. However, there is currently no dedicated key comparison to demonstrate the scale conformity. To date, scale conformity has been proved only for classical in-plane geometries, in comparisons between different national metrology institutes (NMIs) and designated institutes (DIs). This study aims at expanding that with nonclassical geometries, including, for the first time, to the best of our knowledge, two out-of-plane geometries. A total of four NMIs and two DIs participated in a scale comparison of the BRDF measurements of three achromatic samples at 550 nm in five measurement geometries. The realization of the scale of BRDF is a well-understood procedure, as explained in this paper, but the comparison of the measured values presents slight inconsistencies in some geometries, most likely due to the underestimation of measurement uncertainties. This underestimation was revealed and indirectly quantified using the Mandel–Paule method, which provides the interlaboratory uncertainty. The results from the presented comparison allow the present state of the BRDF scale realization to be evaluated, not only for classical in-plane geometries, but also for out-of-plane geometries.
- 21 April 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (13) , 3320-3329
Intercomparison of bidirectional reflectance distribution function measurements at in- and out-of-plane geometries
In recent years, there has been a growing interest in the measurements of the bidirectional reflectance distribution function (BRDF) in industry and research and development. However, there is currently no dedicated key comparison to demonstrate the scale conformity. To date, scale conformity has been proved only for classical in-plane geometries, in comparisons between different national metrology institutes (NMIs) and designated institutes (DIs). This study aims at expanding that with nonclassical geometries, including, for the first time, to the best of our knowledge, two out-of-plane geometries. A total of four NMIs and two DIs participated in a scale comparison of the BRDF measurements of three achromatic samples at 550 nm in five measurement geometries. The realization of the scale of BRDF is a well-understood procedure, as explained in this paper, but the comparison of the measured values presents slight inconsistencies in some geometries, most likely due to the underestimation of measurement uncertainties. This underestimation was revealed and indirectly quantified using the Mandel–Paule method, which provides the interlaboratory uncertainty. The results from the presented comparison allow the present state of the BRDF scale realization to be evaluated, not only for classical in-plane geometries, but also for out-of-plane geometries.
- 5 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (21) , 34175-34188
Primary facility for traceable measurement of the BSSRDF
The bidirectional scattering-surface reflectance distribution function (BSSRDF) is the function that describes the variation of the radiance of the elementary areas of a surface with respect to the directionally incident radiant flux on that surface. Measurements of the BSSRDF are important for characterizing the translucency of objects and for obtaining those optical parameters affecting volume scattering. However, to date, no traceable measurements of this function are available, since, likely due to its technical complexity, no standard measurement procedure has been established. We have developed a primary facility for measuring the BSSRDF based on a gonio-spectrophotometer with spatial resolution in the collection, spectral resolution in the irradiation, and angular resolution both for irradiation and collection directions. The BSSRDF of twelve homogeneous and translucent samples (with controlled values for the mean diameter of the scattering particles and their concentration) have been measured with relative uncertainties below 3% inside the irradiated area. Some results are shown and commented. This primary facility will allow the BSSRDF scale to be transferred to other instruments.
- 5 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (21) , 34175-34188
Primary facility for traceable measurement of the BSSRDF
The bidirectional scattering-surface reflectance distribution function (BSSRDF) is the function that describes the variation of the radiance of the elementary areas of a surface with respect to the directionally incident radiant flux on that surface. Measurements of the BSSRDF are important for characterizing the translucency of objects and for obtaining those optical parameters affecting volume scattering. However, to date, no traceable measurements of this function are available, since, likely due to its technical complexity, no standard measurement procedure has been established. We have developed a primary facility for measuring the BSSRDF based on a gonio-spectrophotometer with spatial resolution in the collection, spectral resolution in the irradiation, and angular resolution both for irradiation and collection directions. The BSSRDF of twelve homogeneous and translucent samples (with controlled values for the mean diameter of the scattering particles and their concentration) have been measured with relative uncertainties below 3% inside the irradiated area. Some results are shown and commented. This primary facility will allow the BSSRDF scale to be transferred to other instruments.