Jan-Hendrik Arndt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan-Hendrik Arndt has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Tibor Macko
6 shared publications- Robert Brüll
Division Plastics, Department Material Analytics and Characterization, Fraunhofer Institute for Structural Durability and System Reliability (LBF), Darmstadt, Germany
5 shared publications - Subrajeet Deshmukh
Fraunhofer Institute for Structural Durability and System Reliability, Division Plastics, Group Material Analysis, Schlossgartenstrasse 6, 64289, Darmstadt, Germany
5 shared publications Robert Brüll
Fraunhofer Institute for Structural Durability and System Reliability, Division Plastics, Group Material Analysis , Schlossgartenstrasse 6
4 shared publicationsRaffaele Bernardo
3 shared publications- Guru Geertz
Division Plastics, Fraunhofer Institute for Structural Durability and System Reliability LBF, Schlossgartenstr. 6, 64289 Darmstadt, Germany
2 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Wiley in Nano Select
- Vol. 7 (11) , e70198
Influencing Factors on the Degradation of PLA‐SPION Markers for Medical Devices in Magnetic Imaging Modalities—An In Vitro Study
Polylactic acid (PLA), with its degradable characteristics, is a versatile polymer used for various application scenarios. Coating medical instruments with a composite of PLA and superparamagnetic iron‐oxide nanoparticles (SPIONs) allows for their visualization in Magnetic Particle Imaging and Magnetic Resonance Imaging, which could enable functional diagnostics in medicine. This study investigates the influencing factors on the degradation of PLA‐SPION markers. The influence of the SPION mass fraction, surrounding medium/pH, carrier material, and initial coating mass on the hydrolytic degradation is monitored at 37°C for up to 4 weeks. It is shown that the addition of SPIONs generally decreases the degradation rate compared to neat PLA. However, within the composites, a higher SPION mass fraction increases the degradation rate. The markers degrade relatively quickly at a physiological pH of 7.4, while a more acidic environment reduces the degradation rate. A lighter initial coating mass also facilitates degradation, while the carrier material seems to have a marginal effect on the degradation rate. These results allow for a better understanding of the influencing factors on the degradation of PLA‐SPION markers and support the feasibility of functional imaging with these markers.
- 30 October 2026
- Published by Wiley in Nano Select
- Vol. 7 (11) , e70198
Open AccessInfluencing Factors on the Degradation of PLA‐SPION Markers for Medical Devices in Magnetic Imaging Modalities—An In Vitro Study
Polylactic acid (PLA), with its degradable characteristics, is a versatile polymer used for various application scenarios. Coating medical instruments with a composite of PLA and superparamagnetic iron‐oxide nanoparticles (SPIONs) allows for their visualization in Magnetic Particle Imaging and Magnetic Resonance Imaging, which could enable functional diagnostics in medicine. This study investigates the influencing factors on the degradation of PLA‐SPION markers. The influence of the SPION mass fraction, surrounding medium/pH, carrier material, and initial coating mass on the hydrolytic degradation is monitored at 37°C for up to 4 weeks. It is shown that the addition of SPIONs generally decreases the degradation rate compared to neat PLA. However, within the composites, a higher SPION mass fraction increases the degradation rate. The markers degrade relatively quickly at a physiological pH of 7.4, while a more acidic environment reduces the degradation rate. A lighter initial coating mass also facilitates degradation, while the carrier material seems to have a marginal effect on the degradation rate. These results allow for a better understanding of the influencing factors on the degradation of PLA‐SPION markers and support the feasibility of functional imaging with these markers.
- 11 August 2026
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 59 (17) , 9584-9594
Photocatalytic Functionalization of iPP under UV and Mild Conditions: From Direct Surface Activation to Blend Compatibilization
Post-polymerization C(sp3)–H functionalization of isotactic polypropylene (iPP) represents a key strategy to overcome its inherently nonpolar nature and enhance interfacial compatibility, yet conventional methods remain limited in material quality. Here, we report an alternative approach to functionalize both solid iPP surfaces and molecular iPP chains using a UV-driven photocatalytic method under mild conditions. We demonstrate that this strategy, performed at 25 °C and under aerobic conditions in the presence of maleic anhydride (MAH), transforms iPP surfaces into polar analogues, with the polar component of the surface energy reaching up to 20 mN/m and exhibiting excellent shelf-life stability over several months. Complementary, the modified synthetic protocol applied to iPP gels at 50 °C under inert conditions enables the synthesis of high-molecular-weight iPP-graft-MAH at functionalization levels of approximately 1 MAH per chain with only marginal chain scission. This process is regioselective to tertiary carbons and favors the functionalization of longer chains, providing conceptual advantages over industrial references. We demonstrate the processability of the resulting products and the mechanical property enhancements when used as phase compatibilizers in blends with polycaprolactone and natural wood.
- 11 August 2026
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 59 (17) , 9584-9594
Photocatalytic Functionalization of iPP under UV and Mild Conditions: From Direct Surface Activation to Blend Compatibilization
Post-polymerization C(sp3)–H functionalization of isotactic polypropylene (iPP) represents a key strategy to overcome its inherently nonpolar nature and enhance interfacial compatibility, yet conventional methods remain limited in material quality. Here, we report an alternative approach to functionalize both solid iPP surfaces and molecular iPP chains using a UV-driven photocatalytic method under mild conditions. We demonstrate that this strategy, performed at 25 °C and under aerobic conditions in the presence of maleic anhydride (MAH), transforms iPP surfaces into polar analogues, with the polar component of the surface energy reaching up to 20 mN/m and exhibiting excellent shelf-life stability over several months. Complementary, the modified synthetic protocol applied to iPP gels at 50 °C under inert conditions enables the synthesis of high-molecular-weight iPP-graft-MAH at functionalization levels of approximately 1 MAH per chain with only marginal chain scission. This process is regioselective to tertiary carbons and favors the functionalization of longer chains, providing conceptual advantages over industrial references. We demonstrate the processability of the resulting products and the mechanical property enhancements when used as phase compatibilizers in blends with polycaprolactone and natural wood.
- Open Access
- 22 July 2026
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 37 (7) , e70689
How the Interplay of Accelerated Aging and Sterilization by γ ‐Irradiation Influences the Recyclability of Medical Polypropylene Copolymer
Recycling of medical‐grade plastics remains challenging due to stringent quality and safety requirements. We investigated the combined effects of two injection molding/ γ ‐irradiation (25 kGy) cycles and accelerated aging simulating 1 year of service life on two compounds consisting of isotactic polypropylene copolymer containing less than 10 mol‐% ethylene (PP‐C) and different stabilizer compositions. One composition comprised the primary antioxidant Irganox 1010 (I1010), the secondary antioxidant Irgafos 168 (I168), the radiation stabilizer Tinuvin 622 (T622), and calcium stearate (CaSt) as acid scavenger, while the second composition was lacking I1010. For comparison, both compounds were subjected to the same treatments without γ ‐irradiation. We analyzed additive consumption, radiolysis product formation, molar mass evolution, rheological behavior, and crystallinity. High‐performance liquid chromatography (HPLC) and gas chromatography combined with mass spectrometry (GC–MS) revealed pronounced degradation of I1010 and I168, particularly after γ ‐irradiation. The presence of I1010 mitigated the depletion of I168, indicating synergistic stabilization. The radiolysis product 1,3‐di‐tert‐butylbenzene (DTBB) formed upon γ ‐irradiation, confirming additive decomposition. Gel permeation chromatography (GPC) and oscillatory rheometry showed a reduction in PP‐C molar mass and zero‐shear viscosity reflecting chain scission. The slope of the relation of the PP‐C radius of gyration and its molar mass M indicated that γ ‐irradiation primarily induced long chain branching in the absence of I1010. In contrast, X‐ray diffraction (XRD) revealed only minor changes in crystallinity, suggesting that the crystalline phase remained largely unaffected by the irradiation and injection molding history. Overall, irradiation effects exceeded those of reprocessing and accelerated aging, indicating that sterilization crucially impacts recyclability of PP‐C in medical products.
- 22 July 2026
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 37 (7) , e70689
Open AccessHow the Interplay of Accelerated Aging and Sterilization by γ ‐Irradiation Influences the Recyclability of Medical Polypropylene Copolymer
Recycling of medical‐grade plastics remains challenging due to stringent quality and safety requirements. We investigated the combined effects of two injection molding/ γ ‐irradiation (25 kGy) cycles and accelerated aging simulating 1 year of service life on two compounds consisting of isotactic polypropylene copolymer containing less than 10 mol‐% ethylene (PP‐C) and different stabilizer compositions. One composition comprised the primary antioxidant Irganox 1010 (I1010), the secondary antioxidant Irgafos 168 (I168), the radiation stabilizer Tinuvin 622 (T622), and calcium stearate (CaSt) as acid scavenger, while the second composition was lacking I1010. For comparison, both compounds were subjected to the same treatments without γ ‐irradiation. We analyzed additive consumption, radiolysis product formation, molar mass evolution, rheological behavior, and crystallinity. High‐performance liquid chromatography (HPLC) and gas chromatography combined with mass spectrometry (GC–MS) revealed pronounced degradation of I1010 and I168, particularly after γ ‐irradiation. The presence of I1010 mitigated the depletion of I168, indicating synergistic stabilization. The radiolysis product 1,3‐di‐tert‐butylbenzene (DTBB) formed upon γ ‐irradiation, confirming additive decomposition. Gel permeation chromatography (GPC) and oscillatory rheometry showed a reduction in PP‐C molar mass and zero‐shear viscosity reflecting chain scission. The slope of the relation of the PP‐C radius of gyration and its molar mass M indicated that γ ‐irradiation primarily induced long chain branching in the absence of I1010. In contrast, X‐ray diffraction (XRD) revealed only minor changes in crystallinity, suggesting that the crystalline phase remained largely unaffected by the irradiation and injection molding history. Overall, irradiation effects exceeded those of reprocessing and accelerated aging, indicating that sterilization crucially impacts recyclability of PP‐C in medical products.
- 15 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (17) , 10824-10841
Combining the Incompatible: Melt State Grafting between High-Density Polyethylene and Isotactic Polypropylene without a Coupling Agent
- 15 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (17) , 10824-10841
Combining the Incompatible: Melt State Grafting between High-Density Polyethylene and Isotactic Polypropylene without a Coupling Agent
- Open Access
- 2 December 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1714, 464557
Characterizing graft distribution in maleic anhydride grafted polyethylene – GPC with IR and UV-detection
- 2 December 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1714, 464557
Open AccessCharacterizing graft distribution in maleic anhydride grafted polyethylene – GPC with IR and UV-detection
- Open Access
- 6 July 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (36)
Separation of amorphous and semicrystalline parts of LLDPE with high‐temperature interactive liquid chromatography
Linear low‐density polyethylene (LLDPE) materials may contain components, which are soluble at room temperature. These may influence physical properties or raise concerns for end‐users and regulatory bodies because LLDPE is widely used for food packaging. Due to the nonpolar and amorphous nature of the room temperature soluble part of LLDPE, its molecular characterization with common methods for polyolefin analysis, such as Temperature Rising Elution Fractionation (TREF), Crystallization Fractionation (CRYSTAF), or Differential Scanning Calorimetry (DSC), has proven to be very challenging. Separation of the amorphous part of LLDPE, as well as its semicrystalline part, is, however, realizable with high‐temperature liquid chromatography (HT‐LC), which is demonstrated for the first time in this work. This technique enables to evaluate the chemical composition distribution of the room‐temperature solubles and non‐solubles in LLDPE samples. It was found that LLDPE synthesized with metallocene catalysts contained only a very small amount of amorphous material. In contrast, LLDPE prepared with Ziegler‐Natta catalysts contained up to 14 wt.% of the amorphous copolymer. The latter was soluble at room temperature, had a weight‐average molar mass ranging from 60 to 200 kg/mol, and contained about 10 mol% more 1‐olefin than the non‐soluble part of LLDPE.
- 6 July 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (36)
Open AccessSeparation of amorphous and semicrystalline parts of LLDPE with high‐temperature interactive liquid chromatography
Linear low‐density polyethylene (LLDPE) materials may contain components, which are soluble at room temperature. These may influence physical properties or raise concerns for end‐users and regulatory bodies because LLDPE is widely used for food packaging. Due to the nonpolar and amorphous nature of the room temperature soluble part of LLDPE, its molecular characterization with common methods for polyolefin analysis, such as Temperature Rising Elution Fractionation (TREF), Crystallization Fractionation (CRYSTAF), or Differential Scanning Calorimetry (DSC), has proven to be very challenging. Separation of the amorphous part of LLDPE, as well as its semicrystalline part, is, however, realizable with high‐temperature liquid chromatography (HT‐LC), which is demonstrated for the first time in this work. This technique enables to evaluate the chemical composition distribution of the room‐temperature solubles and non‐solubles in LLDPE samples. It was found that LLDPE synthesized with metallocene catalysts contained only a very small amount of amorphous material. In contrast, LLDPE prepared with Ziegler‐Natta catalysts contained up to 14 wt.% of the amorphous copolymer. The latter was soluble at room temperature, had a weight‐average molar mass ranging from 60 to 200 kg/mol, and contained about 10 mol% more 1‐olefin than the non‐soluble part of LLDPE.
- 4 July 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1705, 464197
Unraveling the comonomer distribution in ethylene – vinyl ester terpolymers through liquid chromatography with infrared detection
- 4 July 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1705, 464197
Unraveling the comonomer distribution in ethylene – vinyl ester terpolymers through liquid chromatography with infrared detection
- 13 April 2022
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 61 (16) , 5672-5683
Solvent Selection for Liquid Adsorption Chromatography of Ethylene–Propylene–Diene Terpolymers by Combining Structure–Retention Relationships and Hansen Solubility Parameters
- 13 April 2022
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 61 (16) , 5672-5683
Solvent Selection for Liquid Adsorption Chromatography of Ethylene–Propylene–Diene Terpolymers by Combining Structure–Retention Relationships and Hansen Solubility Parameters