Omar Hammad Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Omar Hammad Ali has a total of 209 co-authors. Here are the top co-authors by number of shared publications:
- Maurizio Boscardin
Fondazione Bruno Kessler (FBK), Via Sommarive 18, I-38123 Trento, Italy
9 shared publications - Matteo Centis Vignali
Fondazione Bruno Kessler, Trento, Italy
7 shared publications - Francesco Ficorella
Fondazione Bruno Kessler, via Sommarive 18, Povo, 38123 Trento, Italy
5 shared publications - Giuseppe Maruccio
Omnics Research Group, Department of Mathematics and Physics, University of Salento, CNR-Institute of Nanotechnology, INFN Sezione di Lecce, Via per Monteroni, 73100 Lecce, Italy
5 shared publications - Leonello Servoli
INFN Sezione di Perugia, Perugia, Italy
5 shared publications - Michele Crivellari
Centro per Materiali e i Microsistemi Fondazione Bruno Kessler (FBK), Via Sommarive 18, Povo di Trento, 38123 Trento, Italy
5 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07049
Development and characterization of large area LGADs for space applications
Low Gain Avalanche Diodes (LGADs) are silicon detectors that use the impact ionization process to achieve gain values of about O(10) and timing resolution of O(30 ps) to detect Minimum Ionizing Particles. In High Energy Physics, the state-of-the-art LGADs foreseen for timing layers feature an active thickness of 50 µm and a channel size in the order of O(1 mm^2). Space-based experiments could benefit from a Time-of-Flight system composed by these sensors to distinguish between primary and secondary charged particles hits in the tracker. Scaling up the technology to match the typical channel area of the micro-strip sensors used in spaceborne experiments deteriorates the timing capabilities of the LGADs due, in first approximation, to the increased capacitance. In this study, pad sensors with thickness 50, 100, and 150 µm are investigated, featuring different gain layer profiles, designed to address variation in capacitance. Various layouts are also compared to see their impact on the time resolution. Characterization of leakage current and capacitance as a function of the bias voltage, along with Transient Current Technique, and radioactive source measurements are used to evaluate the performances of these devices. By evaluating gain, noise, and jitter, this work demonstrates the feasibility of designing 1 cm^2 LGADs with a jitter as low as 80 ps. Additionally, the study examines signal propagation and uniformity, as the channel size significantly influence there characteristics and their relevance to timing resolution.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07049
Open AccessDevelopment and characterization of large area LGADs for space applications
Low Gain Avalanche Diodes (LGADs) are silicon detectors that use the impact ionization process to achieve gain values of about O(10) and timing resolution of O(30 ps) to detect Minimum Ionizing Particles. In High Energy Physics, the state-of-the-art LGADs foreseen for timing layers feature an active thickness of 50 µm and a channel size in the order of O(1 mm^2). Space-based experiments could benefit from a Time-of-Flight system composed by these sensors to distinguish between primary and secondary charged particles hits in the tracker. Scaling up the technology to match the typical channel area of the micro-strip sensors used in spaceborne experiments deteriorates the timing capabilities of the LGADs due, in first approximation, to the increased capacitance. In this study, pad sensors with thickness 50, 100, and 150 µm are investigated, featuring different gain layer profiles, designed to address variation in capacitance. Various layouts are also compared to see their impact on the time resolution. Characterization of leakage current and capacitance as a function of the bias voltage, along with Transient Current Technique, and radioactive source measurements are used to evaluate the performances of these devices. By evaluating gain, noise, and jitter, this work demonstrates the feasibility of designing 1 cm^2 LGADs with a jitter as low as 80 ps. Additionally, the study examines signal propagation and uniformity, as the channel size significantly influence there characteristics and their relevance to timing resolution.
- Open Access
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06027
New developments in 3D-trench electrode sensors
Future high-luminosity hadron collider experiments feature unprecedented levels of event pile-up and extreme radiation environments, calling for sensors capable of 4D tracking, even after significant radiation damage. To this purpose, 3D sensors represent a viable solution, since they provide excellent radiation tolerance and very good temporal resolution. In particular, owing to the uniform electric field and weighting field distributions, 3D-trench electrode sensors from the INFN TIMESPOT project have shown a temporal resolution of ∼10 ps after irradiation fluences up to 1×1017 1-Mev neq/cm2. In spite of the excellent performance of these sensors, 3D-trench pixel technology is not yet fully established and the fabrication yield is not yet adequate for the production of large size pixel sensors. To improve the potential of the 3D-trench concept for large-area sensors, a new batch of sensors was designed at the University of Trento and fabricated at FBK, as part of the AIDAinnova project. Besides introducing some process improvements, this batch includes two different sensor variants: the standard one with continuous ohmic trenches, and a modified one with dashed ohmic trenches. On-wafer electrical test results show that most of the sensors have low leakage current and high breakdown voltage. Moreover, the fabrication yield for the new design variant is higher than that of the standard design.
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , C06027
Open AccessNew developments in 3D-trench electrode sensors
Future high-luminosity hadron collider experiments feature unprecedented levels of event pile-up and extreme radiation environments, calling for sensors capable of 4D tracking, even after significant radiation damage. To this purpose, 3D sensors represent a viable solution, since they provide excellent radiation tolerance and very good temporal resolution. In particular, owing to the uniform electric field and weighting field distributions, 3D-trench electrode sensors from the INFN TIMESPOT project have shown a temporal resolution of ∼10 ps after irradiation fluences up to 1×1017 1-Mev neq/cm2. In spite of the excellent performance of these sensors, 3D-trench pixel technology is not yet fully established and the fabrication yield is not yet adequate for the production of large size pixel sensors. To improve the potential of the 3D-trench concept for large-area sensors, a new batch of sensors was designed at the University of Trento and fabricated at FBK, as part of the AIDAinnova project. Besides introducing some process improvements, this batch includes two different sensor variants: the standard one with continuous ohmic trenches, and a modified one with dashed ohmic trenches. On-wafer electrical test results show that most of the sensors have low leakage current and high breakdown voltage. Moreover, the fabrication yield for the new design variant is higher than that of the standard design.
- Open Access
- 25 September 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (19) , 1551
Mobility Gaps of Hydrogenated Amorphous Silicon Related to Hydrogen Concentration and Its Influence on Electrical Performance
This paper presents a comprehensive study of hydrogenated amorphous silicon (a-Si)-based detectors, utilizing electrical characterization, Raman spectroscopy, photoemission, and inverse photoemission techniques. The unique properties of a-Si have sparked interest in its application for radiation detection in both physics and medicine. Although amorphous silicon (a-Si) is inherently a highly defective material, hydrogenation significantly reduces defect density, enabling its use in radiation detector devices. Spectroscopic measurements provide insights into the intricate relationship between the structure and electronic properties of a-Si, enhancing our understanding of how specific configurations, such as the choice of substrate, can markedly influence detector performance. In this study, we compare the performance of a-Si detectors deposited on two different substrates: crystalline silicon (c-Si) and flexible Kapton. Our findings suggest that detectors deposited on Kapton exhibit reduced sensitivity, despite having comparable noise and leakage current levels to those on crystalline silicon. We hypothesize that this discrepancy may be attributed to the substrate material, differences in film morphology, and/or the alignment of energy levels. Further measurements are planned to substantiate these hypotheses.
- 25 September 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (19) , 1551
Open AccessMobility Gaps of Hydrogenated Amorphous Silicon Related to Hydrogen Concentration and Its Influence on Electrical Performance
This paper presents a comprehensive study of hydrogenated amorphous silicon (a-Si)-based detectors, utilizing electrical characterization, Raman spectroscopy, photoemission, and inverse photoemission techniques. The unique properties of a-Si have sparked interest in its application for radiation detection in both physics and medicine. Although amorphous silicon (a-Si) is inherently a highly defective material, hydrogenation significantly reduces defect density, enabling its use in radiation detector devices. Spectroscopic measurements provide insights into the intricate relationship between the structure and electronic properties of a-Si, enhancing our understanding of how specific configurations, such as the choice of substrate, can markedly influence detector performance. In this study, we compare the performance of a-Si detectors deposited on two different substrates: crystalline silicon (c-Si) and flexible Kapton. Our findings suggest that detectors deposited on Kapton exhibit reduced sensitivity, despite having comparable noise and leakage current levels to those on crystalline silicon. We hypothesize that this discrepancy may be attributed to the substrate material, differences in film morphology, and/or the alignment of energy levels. Further measurements are planned to substantiate these hypotheses.
- Open Access
- 29 March 2024
- Published by MDPI AG in Instruments
- Vol. 8 (2) , 27
Jitter Measurements of 1 cm2 LGADs for Space Experiments
This work explores the possibility of using Low Gain Avalanche Diodes (LGADs) for tracker-based experiments studying Charged Cosmic Rays (CCRs) in space. While conventional silicon microstrip sensors provide only spatial information about the charged particle passing through the tracker, LGADs have the potential to provide additional timing information with a resolution in the order of tens of picoseconds. For the first time, it has been demonstrated that an LGAD with an active area of approximately 1 cm2 can achieve a jitter of less than 40 ps. A comparison of design and gain layers is carried out to understand which provides the best time resolution. For this purpose, laboratory measurements of sensors’ electrical properties and gain using LED and an Infrared laser, as well as their jitter, were performed.
- 29 March 2024
- Published by MDPI AG in Instruments
- Vol. 8 (2) , 27
Open AccessJitter Measurements of 1 cm2 LGADs for Space Experiments
This work explores the possibility of using Low Gain Avalanche Diodes (LGADs) for tracker-based experiments studying Charged Cosmic Rays (CCRs) in space. While conventional silicon microstrip sensors provide only spatial information about the charged particle passing through the tracker, LGADs have the potential to provide additional timing information with a resolution in the order of tens of picoseconds. For the first time, it has been demonstrated that an LGAD with an active area of approximately 1 cm2 can achieve a jitter of less than 40 ps. A comparison of design and gain layers is carried out to understand which provides the best time resolution. For this purpose, laboratory measurements of sensors’ electrical properties and gain using LED and an Infrared laser, as well as their jitter, were performed.
- Open Access
Quantum Efficiency Measurement and Modeling of Silicon Sensors Optimized for Soft X-ray Detection
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.Open AccessQuantum Efficiency Measurement and Modeling of Silicon Sensors Optimized for Soft X-ray Detection
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement. - Open Access
- 29 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235009
Performance of LGAD strip detectors for particle counting of therapeutic proton beams
Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.
- 29 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235009
Open AccessPerformance of LGAD strip detectors for particle counting of therapeutic proton beams
Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.
- Open Access
- 4 October 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (19) , 3466
High-Resolution Photoemission Study of Neutron-Induced Defects in Amorphous Hydrogenated Silicon Devices
In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.
- 4 October 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (19) , 3466
Open AccessHigh-Resolution Photoemission Study of Neutron-Induced Defects in Amorphous Hydrogenated Silicon Devices
In this paper, by means of high-resolution photoemission, soft X-ray absorption and atomic force microscopy, we investigate, for the first time, the mechanisms of damaging, induced by neutron source, and recovering (after annealing) of p-i-n detector devices based on hydrogenated amorphous silicon (a-Si:H). This investigation will be performed by mean of high-resolution photoemission, soft X-Ray absorption and atomic force microscopy. Due to dangling bonds, the amorphous silicon is a highly defective material. However, by hydrogenation it is possible to reduce the density of the defect by several orders of magnitude, using hydrogenation and this will allow its usage in radiation detector devices. The investigation of the damage induced by exposure to high energy irradiation and its microscopic origin is fundamental since the amount of defects determine the electronic properties of the a-Si:H. The comparison of the spectroscopic results on bare and irradiated samples shows an increased degree of disorder and a strong reduction of the Si-H bonds after irradiation. After annealing we observe a partial recovering of the Si-H bonds, reducing the disorder in the Si (possibly due to the lowering of the radiation-induced dangling bonds). Moreover, effects in the uppermost coating are also observed by spectroscopies.