Vu Van Quang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vu Van Quang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Vu Toan Thang
School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi 100000, Vietnam
4 shared publications - Bui Hai Dang
Precision Engineering & Smart Measurement Lab, School of Mechanical Engineering, Hanoi University of Science and Technology, Hanoi 100000, Vietnam
2 shared publications - Cong Tuan Truong
School of Mechanical Engineering, Hanoi University of Science and Technology, 1st Dai Co Viet Road, Hai Ba Trung District, Hanoi 100000, Vietnam
1 shared publication Doan Van Phuc
Military Institute of Science and Technology of Vietnam
1 shared publication- Duc-Toan Nguyen
Hanoi University of Science and Technology
1 shared publication - Ngoc-Tam Bui
Innovative Global Program, Shibaura Institute of Technology, Saitama, Japan
1 shared publication
Latest Publications
- Open Access
Physics-Informed Identification of Spatial and Dynamic Responses of Dual-Element Pyroelectric Infrared Sensors Using Variable Circular-Aperture Excitation
This paper proposes a physics-informed identification framework for the spatial and dynamic responses of dual-element pyroelectric infrared (PIR) sensors using variable circular-aperture excitation. The dynamic half is carried through to experimental identification, while the spatial half is carried only to the reference-pose location, so the joint estimation is proposed rather than demonstrated. The spatial response is modeled as a bipolar differential kernel composed of a pose-dependent optical mapping, an optical envelope with a spatial scale factor, two smoothed rectangular sensing-element footprints, and a small antisymmetric residual correction. Sinusoidal modulation of the aperture radius leads to a complex first-harmonic frequency-domain model relating the measured response to aperture radius, modulation amplitude, pose setting, and excitation frequency. Rather than being assumed, the dynamic structure is identified from a 40-point frequency sweep spanning 0.0999 to 4.0453 Hz. A compact two-time-constant differentiating model leaves a root-mean-square log-magnitude error of 15.1%, with a maximum log-magnitude deviation of 48.4% (62% in relative amplitude). A structure with two zeros at the origin and four poles reproduces the same measurement to 0.71% root-mean-square. Its poles are an underdamped complex pair at 0.2126 Hz with damping ratio 0.899 and real poles at 0.5023 Hz and 2.9672 Hz. The additional zero and pole are tentatively attributed to the AC-coupled conditioning stage. Evaluated at this identified operating point, the scaled Jacobian of the dynamic block is full column rank with cond(Js) = 75.8, and Cramér–Rao bounds agree with residual-bootstrap intervals to within ten per cent on every parameter. A greedy D-optimal selection retains 61.6% of the information of the full sweep from ten frequencies, whereas the originally proposed excitation grid attains only 13.8% because it does not sample the band containing the identified pole pair. Restoring the excitation phase reference increases the Fisher determinant by a factor of 130. A structured estimation procedure is also formulated, in which the residual coefficients are updated through a regularized linear least-squares subproblem within a staged optimization exploiting the disparate conditioning of the spatial and dynamic blocks. It has not yet been executed on a joint aperture–pose–frequency data set.
Open AccessPhysics-Informed Identification of Spatial and Dynamic Responses of Dual-Element Pyroelectric Infrared Sensors Using Variable Circular-Aperture Excitation
This paper proposes a physics-informed identification framework for the spatial and dynamic responses of dual-element pyroelectric infrared (PIR) sensors using variable circular-aperture excitation. The dynamic half is carried through to experimental identification, while the spatial half is carried only to the reference-pose location, so the joint estimation is proposed rather than demonstrated. The spatial response is modeled as a bipolar differential kernel composed of a pose-dependent optical mapping, an optical envelope with a spatial scale factor, two smoothed rectangular sensing-element footprints, and a small antisymmetric residual correction. Sinusoidal modulation of the aperture radius leads to a complex first-harmonic frequency-domain model relating the measured response to aperture radius, modulation amplitude, pose setting, and excitation frequency. Rather than being assumed, the dynamic structure is identified from a 40-point frequency sweep spanning 0.0999 to 4.0453 Hz. A compact two-time-constant differentiating model leaves a root-mean-square log-magnitude error of 15.1%, with a maximum log-magnitude deviation of 48.4% (62% in relative amplitude). A structure with two zeros at the origin and four poles reproduces the same measurement to 0.71% root-mean-square. Its poles are an underdamped complex pair at 0.2126 Hz with damping ratio 0.899 and real poles at 0.5023 Hz and 2.9672 Hz. The additional zero and pole are tentatively attributed to the AC-coupled conditioning stage. Evaluated at this identified operating point, the scaled Jacobian of the dynamic block is full column rank with cond(Js) = 75.8, and Cramér–Rao bounds agree with residual-bootstrap intervals to within ten per cent on every parameter. A greedy D-optimal selection retains 61.6% of the information of the full sweep from ten frequencies, whereas the originally proposed excitation grid attains only 13.8% because it does not sample the band containing the identified pole pair. Restoring the excitation phase reference increases the Fisher determinant by a factor of 130. A structured estimation procedure is also formulated, in which the residual coefficients are updated through a regularized linear least-squares subproblem within a staged optimization exploiting the disparate conditioning of the spatial and dynamic blocks. It has not yet been executed on a joint aperture–pose–frequency data set.
- Open Access
- 2 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (11) , 6255
Evaluation of Correlation-Based Methods for Time Period Estimation in Vehicle Speed Measurement Using Pyroelectric Infrared Sensors
Accurate time period estimation (TPE) between sensor signals is essential for vehicle speed measurement in intelligent transportation systems (ITSs). In this context, we focus on time period estimation using signals acquired from a dual pyroelectric infrared (PIR) sensor setup. To estimate the time period between these signals, this paper analyzes and compares two correlation-based methods—conventional cross-correlation (CCF) and Hilbert transform-enhanced cross-correlation (CCFHT). An analytical framework is developed to quantify the bias and variance of each method under practical conditions, including sensor mismatch and noise. The PIR sensor signals are modeled based on their dynamic response characteristics, enabling theoretical analysis supported by simulations and field experiments. Results show that although both methods yield negligible bias under ideal conditions, CCFHT significantly reduces estimation variance in noisy or mismatched scenarios. These findings confirm the advantages of CCFHT for achieving robust and precise vehicle speed estimation using low-cost PIR sensor systems, and provide insights into practical deployment within ITSs.
- 2 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (11) , 6255
Open AccessEvaluation of Correlation-Based Methods for Time Period Estimation in Vehicle Speed Measurement Using Pyroelectric Infrared Sensors
Accurate time period estimation (TPE) between sensor signals is essential for vehicle speed measurement in intelligent transportation systems (ITSs). In this context, we focus on time period estimation using signals acquired from a dual pyroelectric infrared (PIR) sensor setup. To estimate the time period between these signals, this paper analyzes and compares two correlation-based methods—conventional cross-correlation (CCF) and Hilbert transform-enhanced cross-correlation (CCFHT). An analytical framework is developed to quantify the bias and variance of each method under practical conditions, including sensor mismatch and noise. The PIR sensor signals are modeled based on their dynamic response characteristics, enabling theoretical analysis supported by simulations and field experiments. Results show that although both methods yield negligible bias under ideal conditions, CCFHT significantly reduces estimation variance in noisy or mismatched scenarios. These findings confirm the advantages of CCFHT for achieving robust and precise vehicle speed estimation using low-cost PIR sensor systems, and provide insights into practical deployment within ITSs.
- 30 August 2023
- Published by Springer Nature
- p. 37-44
Research and Fabrication of Metal Powder Dispersing Equipment for 3D Printing Technology
- 30 August 2023
- Published by Springer Nature
- p. 37-44
Research and Fabrication of Metal Powder Dispersing Equipment for 3D Printing Technology
- Open Access
- 4 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7845
Enhancing Fire Detection Technology: A UV-Based System Utilizing Fourier Spectrum Analysis for Reliable and Accurate Fire Detection
This study proposes a low-cost and reliable smart fire alarm system that utilizes ultraviolet (UV) detection technology with an aspherical lens to detect fires emitting photons in the 185–260 nm range. The system integrates the aspherical lens with an accelerator and a digital compass to determine the fire source’s direction, allowing for safe evacuation and effective firefighting. Artificial intelligence is employed to reduce false alarms and achieve a low false alarm rate. The system’s wide detection range and direction verification make it an effective fire detection solution. Upon detecting a fire, the system sends a warning signal via Wi-Fi or smartphone to the user. The proposed system’s advantages include early warning, a low false alarm rate, and detection of a wide range of fires. Experimental results validate the system’s design and demonstrate high accuracy, reliability, and practicality, making it a valuable addition to fire management and prevention. The proposed system utilizes a parabolic mirror to collect UV radiation into the detector and a simple classification model that uses Fourier transform algorithm to reduce false alarms. The results showed accuracies of approximately 95.45% and 93.65% for the flame and UVB lamp, respectively. The system demonstrated its effectiveness in detecting flames in the range of up to 50 m, making it suitable for various applications, including small and medium-sized buildings, homes, and vehicles.
- 4 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (13) , 7845
Open AccessEnhancing Fire Detection Technology: A UV-Based System Utilizing Fourier Spectrum Analysis for Reliable and Accurate Fire Detection
This study proposes a low-cost and reliable smart fire alarm system that utilizes ultraviolet (UV) detection technology with an aspherical lens to detect fires emitting photons in the 185–260 nm range. The system integrates the aspherical lens with an accelerator and a digital compass to determine the fire source’s direction, allowing for safe evacuation and effective firefighting. Artificial intelligence is employed to reduce false alarms and achieve a low false alarm rate. The system’s wide detection range and direction verification make it an effective fire detection solution. Upon detecting a fire, the system sends a warning signal via Wi-Fi or smartphone to the user. The proposed system’s advantages include early warning, a low false alarm rate, and detection of a wide range of fires. Experimental results validate the system’s design and demonstrate high accuracy, reliability, and practicality, making it a valuable addition to fire management and prevention. The proposed system utilizes a parabolic mirror to collect UV radiation into the detector and a simple classification model that uses Fourier transform algorithm to reduce false alarms. The results showed accuracies of approximately 95.45% and 93.65% for the flame and UVB lamp, respectively. The system demonstrated its effectiveness in detecting flames in the range of up to 50 m, making it suitable for various applications, including small and medium-sized buildings, homes, and vehicles.
- Open Access
A Setup for Measuring the Centering Error of a Dual-Element Pyroelectric Infrared Sensor Module
This paper presents an experimental setup to measure the horizontal centering error of a pre-built pyroelectric infrared (PIR) sensor module, in which a dual-element PIR sensor is aligned at the focal point of a single-zone Fresnel Lens. In the setup, the sensor module was placed facing a modulated infrared radiating source and turned over a range of horizontal angles. The position of the optical axis of the sensor module was determined based on the analysis of the output response of the sensor at turned angles. Thus, the horizontal centering error of the module is defined as the difference between the mechanical axis of the housing and the found optical axis. For the prebuilt sensor module, with the specific available equipment, the measurement of the centering error of the module achieved a resolution of 0.02 degrees.
Open AccessA Setup for Measuring the Centering Error of a Dual-Element Pyroelectric Infrared Sensor Module
This paper presents an experimental setup to measure the horizontal centering error of a pre-built pyroelectric infrared (PIR) sensor module, in which a dual-element PIR sensor is aligned at the focal point of a single-zone Fresnel Lens. In the setup, the sensor module was placed facing a modulated infrared radiating source and turned over a range of horizontal angles. The position of the optical axis of the sensor module was determined based on the analysis of the output response of the sensor at turned angles. Thus, the horizontal centering error of the module is defined as the difference between the mechanical axis of the housing and the found optical axis. For the prebuilt sensor module, with the specific available equipment, the measurement of the centering error of the module achieved a resolution of 0.02 degrees.