Lichan Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lichan Chen has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
Guonan Chen
MOE Key Laboratory of Analysis and Detection Technology for Food Safety, and College of Chemistry, Fuzhou University, Fuzhou, China
12 shared publicationsYuwu Chi
Key Laboratory for Analytical Science of Food Safety and Biology, Ministry of Education, College of Chemistry Fuzhou University Fuzhou Fujian 350108 P. R China
11 shared publications- Yuwu Chi
MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian 350108, China
9 shared publications Libing Tian
College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
7 shared publications- Dezhong Joshua Liao
Center for Clinical Laboratories, The Affiliated Hospital of Guizhou Medical University, 4 Beijing Rd, Guiyang, 550004, Guizhou Province, China
6 shared publications - Ningzhi Xu
Laboratory of Cell and Molecular Biology & State Key Laboratory of Molecular Oncology, Cancer Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, PR China
6 shared publications
Latest Publications
- 18 June 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (7) , 1-9
Target-responsive vesicular nanoprobe for fluorescent detection of lipase
A novel fluorescent vesicular nanoprobe (RhB@HMCNx-PCL-PEG) is presented for lipase activity monitoring, leveraging the synergetic integration of nitrogen-deficient hollow mesoporous carbon nitride nanoparticles (HMCNx) and lipase-responsive amphiphilic block copolymers. The HMCNx, engineered via KSCN-assisted hydrothermal treatment, exhibits enhanced water dispersibility while remaining its hollow mesoporous structure, enabling efficient encapsulation of rhodamine B (RhB). Subsequent covalent conjugation of carboxyl-terminated poly(ε-caprolactone)-poly(ethylene glycol) (COOH-PCL-PEG) and self-assembly-driven vesicle formation establish a “signal-on” detection mechanism. Lipase-triggered hydrolysis of the PCL layer releases RhB, with fluorescence intensity quantitatively correlating to lipase activity. The nanoprobe achieves a low detection limit of 0.5 mU mL⁻1 (3σ) and a broad linear range (0.5 to 5 U mL⁻1). Remarkable selectivity against interferents (e.g., trypsin, α-amylase) and robust performance in real samples (milk, skin toner) underscore its practicality. This work not only advances carbon nitride–based nanomaterials for biosensing but also provides a platform for enzyme-responsive detection systems. Graphical Abstract
- 18 June 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (7) , 1-9
Target-responsive vesicular nanoprobe for fluorescent detection of lipase
A novel fluorescent vesicular nanoprobe (RhB@HMCNx-PCL-PEG) is presented for lipase activity monitoring, leveraging the synergetic integration of nitrogen-deficient hollow mesoporous carbon nitride nanoparticles (HMCNx) and lipase-responsive amphiphilic block copolymers. The HMCNx, engineered via KSCN-assisted hydrothermal treatment, exhibits enhanced water dispersibility while remaining its hollow mesoporous structure, enabling efficient encapsulation of rhodamine B (RhB). Subsequent covalent conjugation of carboxyl-terminated poly(ε-caprolactone)-poly(ethylene glycol) (COOH-PCL-PEG) and self-assembly-driven vesicle formation establish a “signal-on” detection mechanism. Lipase-triggered hydrolysis of the PCL layer releases RhB, with fluorescence intensity quantitatively correlating to lipase activity. The nanoprobe achieves a low detection limit of 0.5 mU mL⁻1 (3σ) and a broad linear range (0.5 to 5 U mL⁻1). Remarkable selectivity against interferents (e.g., trypsin, α-amylase) and robust performance in real samples (milk, skin toner) underscore its practicality. This work not only advances carbon nitride–based nanomaterials for biosensing but also provides a platform for enzyme-responsive detection systems. Graphical Abstract
- 4 June 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (14) , 3170-3176
Film-permeability-triggered afterglow electrochemiluminescence for lipase detection
Turning on the afterglow electrochemiluminescence of CNxNS by lipase hydrolysis-induced permeability improvement.
- 4 June 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (14) , 3170-3176
Film-permeability-triggered afterglow electrochemiluminescence for lipase detection
Turning on the afterglow electrochemiluminescence of CNxNS by lipase hydrolysis-induced permeability improvement.
- 9 September 2023
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 947
Strategies to improve the electrochemiluminescence performance of graphitic carbon nitride nanomaterials
- 9 September 2023
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 947
Strategies to improve the electrochemiluminescence performance of graphitic carbon nitride nanomaterials
- 4 September 2023
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (37) , 17220-17223
Modulation of afterglow electrochemiluminescence from nitrogen-deficient graphitic carbon nitride by pH
Enhancing afterglow electrochemiluminescence (ECL) is significant to promote its further application. Here we find that the afterglow ECL of nitrogen-deficient graphitic carbon nitride (g-C3N4−x) nanosheets is modulable by environmental pH, and reaches the maximum at pH 9.0. The modulation mechanism is investigated by coupling the electrochemical and optical methods.
- 4 September 2023
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (37) , 17220-17223
Modulation of afterglow electrochemiluminescence from nitrogen-deficient graphitic carbon nitride by pH
Enhancing afterglow electrochemiluminescence (ECL) is significant to promote its further application. Here we find that the afterglow ECL of nitrogen-deficient graphitic carbon nitride (g-C3N4−x) nanosheets is modulable by environmental pH, and reaches the maximum at pH 9.0. The modulation mechanism is investigated by coupling the electrochemical and optical methods.
- 27 January 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (5) , 2917-2924
Afterglow Electrochemiluminescence from Nitrogen-Deficient Graphitic Carbon Nitride
Almost all current electrochemiluminescent reagents require real-time electrochemical stimulation to emit light. Here, we report a novel electrochemiluminescent reagent, nitrogen-deficient graphitic carbon nitride (CNx), that can emit afterglow electrochemiluminescence (ECL) after cessation of electric excitation. CNx obtained by post-thermal treatment of graphitic carbon nitride (CN) with KSCN has a cyanamide group and a nitrogen vacancy, which created defects to trap electrically injected electrons. The trapped electrons can slowly release and react with coreactants to emit light with longevity. The cathodic afterglow ECL lasts for 70 s after pulsing the CNx nanosheet (CNxNS-1.6)-modified glassy carbon electrode at -1.0 V for 20 s in 2.0 M PBS containing 1 mM K2S2O8. The afterglow ECL mechanism is revealed by investigation of its influencing factors and ECL wavelength. The discovery of afterglow ECL may open a new doorway for new significant applications of the ECL technique and provide a deeper understanding of the structure-property relationships of CN.
- 27 January 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (5) , 2917-2924
Afterglow Electrochemiluminescence from Nitrogen-Deficient Graphitic Carbon Nitride
Almost all current electrochemiluminescent reagents require real-time electrochemical stimulation to emit light. Here, we report a novel electrochemiluminescent reagent, nitrogen-deficient graphitic carbon nitride (CNx), that can emit afterglow electrochemiluminescence (ECL) after cessation of electric excitation. CNx obtained by post-thermal treatment of graphitic carbon nitride (CN) with KSCN has a cyanamide group and a nitrogen vacancy, which created defects to trap electrically injected electrons. The trapped electrons can slowly release and react with coreactants to emit light with longevity. The cathodic afterglow ECL lasts for 70 s after pulsing the CNx nanosheet (CNxNS-1.6)-modified glassy carbon electrode at -1.0 V for 20 s in 2.0 M PBS containing 1 mM K2S2O8. The afterglow ECL mechanism is revealed by investigation of its influencing factors and ECL wavelength. The discovery of afterglow ECL may open a new doorway for new significant applications of the ECL technique and provide a deeper understanding of the structure-property relationships of CN.
- 25 November 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (2) , 628-634
Carbon-based dot-capped gold nanoparticles hybridized with manganese dioxide for enhanced photodynamic cancer therapy
Composite material nanohybrids (FA/MnO2/CDs@AuNPs/CDs) have been synthesized and proven to be excellent photosensitizers for photodynamic therapy applications.
- 25 November 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (2) , 628-634
Carbon-based dot-capped gold nanoparticles hybridized with manganese dioxide for enhanced photodynamic cancer therapy
Composite material nanohybrids (FA/MnO2/CDs@AuNPs/CDs) have been synthesized and proven to be excellent photosensitizers for photodynamic therapy applications.
- 1 November 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (11) , 117507
Functionalized Graphitic Carbon Nitride Nanomaterials for Electrochemiluminescent Detection of Cancer Cells
Biosensors capable of detecting cancer cell quantity is significant for cancer pathological investigation and prognosis. Herein, a facile electrochemiluminescent (ECL) biosensor is developed for cancer cell detection by comprehensively utilizing the features of functionalized graphitic carbon nitride (g-CN) nanomaterials like well film-forming capability and functionalization level tunability. The solid-state ECL biosensor is fabricated via a simple dropping-drying method by subsequent deposition of g-CN nanosheets/graphene oxide nanocomposites (CNNS/GO) as ECL emitter, folate functionalized g-CN quantum dots (FA-CNQDs) as cancer cell capture agent, and bull serum albumin (BSA) as blocker to prevent nonspecific binding on glassy carbon electrodes (GCEs). The strong and stable ECL emission of CNNS/GO along with the tunability of FA content in FA-CNQDs endow the ECL biosensor with competitive sensitivity, which is able to detect folate receptor-positive cancer cells (HepG2) in the concentration range of 10 2 − 10 4 cells ml −1 under optimal condition. Additionally, the proposed ECL biosensor shows high specificity, reproducibility and long-term stability as well as good reliability towards serum sample detection.
- 1 November 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (11) , 117507
Functionalized Graphitic Carbon Nitride Nanomaterials for Electrochemiluminescent Detection of Cancer Cells
Biosensors capable of detecting cancer cell quantity is significant for cancer pathological investigation and prognosis. Herein, a facile electrochemiluminescent (ECL) biosensor is developed for cancer cell detection by comprehensively utilizing the features of functionalized graphitic carbon nitride (g-CN) nanomaterials like well film-forming capability and functionalization level tunability. The solid-state ECL biosensor is fabricated via a simple dropping-drying method by subsequent deposition of g-CN nanosheets/graphene oxide nanocomposites (CNNS/GO) as ECL emitter, folate functionalized g-CN quantum dots (FA-CNQDs) as cancer cell capture agent, and bull serum albumin (BSA) as blocker to prevent nonspecific binding on glassy carbon electrodes (GCEs). The strong and stable ECL emission of CNNS/GO along with the tunability of FA content in FA-CNQDs endow the ECL biosensor with competitive sensitivity, which is able to detect folate receptor-positive cancer cells (HepG2) in the concentration range of 10 2 − 10 4 cells ml −1 under optimal condition. Additionally, the proposed ECL biosensor shows high specificity, reproducibility and long-term stability as well as good reliability towards serum sample detection.
- Open Access
- 15 August 2022
- Published by Ivyspring International Publisher in Theranostics
- Vol. 12 (14) , 6069-6087
DDX56 transcriptionally activates MIST1 to facilitate tumorigenesis of HCC through PTEN-AKT signaling
Rationale: Hepatocellular carcinoma (HCC) is a primary malignancy of the liver that is the leading cause of cancer-related mortality worldwide. However, genetic alterations and mechanisms underlying HCC development remain unclear.
- 15 August 2022
- Published by Ivyspring International Publisher in Theranostics
- Vol. 12 (14) , 6069-6087
Open AccessDDX56 transcriptionally activates MIST1 to facilitate tumorigenesis of HCC through PTEN-AKT signaling
Rationale: Hepatocellular carcinoma (HCC) is a primary malignancy of the liver that is the leading cause of cancer-related mortality worldwide. However, genetic alterations and mechanisms underlying HCC development remain unclear.
- 25 July 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 46 (33) , 16114-16120
Modulating the anodic electrochemiluminescence of graphitic carbon nitride by thiophene doping
As an attractive electrochemiluminescence (ECL) emitter, graphitic carbon nitride (g-CN) still suffers from weak anodic ECL signals. In this work, a simple molecular engineering strategy is employed to modulate the anodic ECL of g-CN by thiophene doping. Thiophene doped g-CN (CNA) nanosheets show ca. a 6-fold enhanced and red-shift ECL emissions compared to pristine g-CN nanosheets. The optical and ECL property studies reveal that thiophene doping can not only evaluate g-CN electric conductivity by intramolecular electron transfer but also narrow the bandgap, leading to the enhancement and bathochromic shift of ECL emissions. The effects of various factors including the thiophene doping amount, solution pH, coreactant concentration and adopted potential range on the anodic ECL of CNA nanosheets are further investigated for understanding the mechanism of ECL enhancement and obtaining a strong and stable anodic ECL emission. On this basis, the CNA nanosheets modified electrode is used as a signal probe for Cu2+ detection, and the probe shows a linear response to Cu2+ in the concentration range of 5 nM to 50 μM and high selectivity towards other possible interfering metal ions. Our work may provide a promising pathway for the modulation of g-CN ECL by molecular engineering, and the improved anodic ECL may promote its sensing application.
- 25 July 2022
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 46 (33) , 16114-16120
Modulating the anodic electrochemiluminescence of graphitic carbon nitride by thiophene doping
As an attractive electrochemiluminescence (ECL) emitter, graphitic carbon nitride (g-CN) still suffers from weak anodic ECL signals. In this work, a simple molecular engineering strategy is employed to modulate the anodic ECL of g-CN by thiophene doping. Thiophene doped g-CN (CNA) nanosheets show ca. a 6-fold enhanced and red-shift ECL emissions compared to pristine g-CN nanosheets. The optical and ECL property studies reveal that thiophene doping can not only evaluate g-CN electric conductivity by intramolecular electron transfer but also narrow the bandgap, leading to the enhancement and bathochromic shift of ECL emissions. The effects of various factors including the thiophene doping amount, solution pH, coreactant concentration and adopted potential range on the anodic ECL of CNA nanosheets are further investigated for understanding the mechanism of ECL enhancement and obtaining a strong and stable anodic ECL emission. On this basis, the CNA nanosheets modified electrode is used as a signal probe for Cu2+ detection, and the probe shows a linear response to Cu2+ in the concentration range of 5 nM to 50 μM and high selectivity towards other possible interfering metal ions. Our work may provide a promising pathway for the modulation of g-CN ECL by molecular engineering, and the improved anodic ECL may promote its sensing application.