AAA.I. Altuchov

A.I. Altuchov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A.I. Altuchov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modeling the illumination of the Earth's surface to select the operating modes of the radiation source

    by A.I. Altuchov, D.S. Korshunov

    An approach to obtain light-signal characteristics in graphoanalytical form is proposed to substantiate the operating modes of the emitting equipment of active optoelectronic complexes of remote sensing of the Earth. These complexes are used for shooting in conditions of insufficient natural illumination of the terrain due to the difficult terrain, geographical location of the area or the low position of the Sun above the plane of the local horizon. Using the presented model, calculations of the energy illumination of the Earth’s surface were carried out, dependencies were constructed that take into account the influence of the position of the Sun above the local horizon plane for specific dates and daily time on the distribution of the spectral density of the electromagnetic radiation flux. Light-signal characteristics have been obtained, which can be used to justify the operating modes of the emitting equipment of active optoelectronic complexes. Based on these characteristics, it is concluded that it is necessary to artificially enhance the spectral density of the radiation flux in a given range of the spectrum in order to achieve the required illumination of the photographed area of the Earth’s surface for a specific date and time. The amplification of the spectral density of the radiation flux makes it possible to create the exposure required for the formation of images with high visual properties. The simulation results are used in the problem of predicting the quality of images obtained using artificial sources of optical illumination. The proposed approach makes it possible to obtain images characterized by the high value of linear resolution on the ground, without resorting to increasing the charge accumulation time by the photodetector of the recording equipment. The application of this approach is particularly relevant in the conditions of conducting aerospace surveys.

  • Open Access

    The concept of aerial photography using a two-element active optoelectronic complex

    by A.I. Altuchov, D.S. Korshunov

    The article proposes the concept of obtaining images on the basis of which it is possible to create three-dimensional models of objects. In particular, images contain the data necessary to recreate the three-dimensional form of an object. Such data include: the length, width of the modeled object as well as the lengthening of the shadow cast on the base surface. In accordance with the proposed concept, an important condition for obtaining images suitable for interpretation is the use of spatially separated equipment generating and recording optical radiation. The orientation parameters of the illumination source and the camera are selected, taking into account the requirements for the photogrammetric quality of images. A characteristic of geometric distortions that occur when changing the shooting mode from plan to perspective is presented, which demonstrates the change in the aspect ratio of the image depending on the angle of the camera. A characteristic of the shadow elongation depending on the spatial position of the optical radiation source is presented, which shows the influence of the orientation parameters of the optical illumination means on the length of the shadow cast on the base surface. On the basis of these characteristics, the choice of parameters of relative orientation in space of the source of optical illumination and the equipment that detects optical radiation is substantiated. Predicting the value of geometric distortions of images at the stage of choosing the parameters of relative orientation of the equipment of a two-element active optoelectronic complex allows you to save the photogrammetric quality of images and, as a result, measure the length and width of an object. Predicting the magnitude of the shadow elongation under conditions of artificial optical illumination provides the possibility of transferring features in the image for calculating the applicate and, as a result, recreating the three-dimensional shape of the object. The proposed concept of image registration finds application in topographic and geodetic and engineering work in conditions of insufficient natural light. For example, the use of a two-element active optical-electronic complex makes it possible to obtain three-dimensional photo plans of the terrain of geographic regions with a short daylight hours.

  • Open Access

    Study and evaluation antioxidant activity of dietary supplements with green tea extract

    by O. Yu. Maslov, S. V. Kolisnyk, M. A. Komisarenko, A. A. Altukhov, K. V. Dynnyk, V. I. Stepanenko, О. О. Алтухов, Е. В. Динник

    The aim of the work is to determine and evaluate the antioxidant activity of dietary supplements with green tea extract, as well as to introduce conditional terms of the level of AOA. Materials and methods. The object of the study was dietary supplements of different manufactures: “Green Tea Extract” of Natural Sources, USA (DS1), “Extract of green tea” of Elit-Pharm, Ukraine (DS2) and “Green tea” of Pharmakom, Ukraine (DS3). Potentiometric measurements were conducted by pH meter Hanna 2550 (Germany) with a combined platinum electrode EZDO 5010. Epigallocatechin-3-O-gallate ˃98.0 % (Sigma Aldrich), K3[Fe(CN)6], K4[Fe(CN)6], NaHPO4, KH2PO4 were analytical grade. Results. It was established that a value of the antioxidant activity of DS1 was 36.51 mmol/tab, DS2 – 29.78 mmol/tab, and DS3 – 16.67 mmol/tab. DS1 had the highest value of the antioxidant activity, which correlated with the content of catechins (r2 = 0.9314). According to the proposed conditional terms of antioxidant activity dietary supplements, DS1 and DS2 possessed a low level of antioxidant activity, whereas DS3 corresponded to very low level of antioxidant activity. Conclusions. It was found that the studied dietary supplements with green tea extract have antioxidant activity, which correlates with the content of catechins.