Jonathan Sabaté del Río
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jonathan Sabaté del Río has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Yoon-Kyoung Cho
Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, South Korea
4 shared publications - Juhee Park
Center for Algorithmic and Robotized Synthesis, Institute for Basic Science (IBS), Ulsan, Republic of Korea
3 shared publications - Tae-Eun Park
Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea
2 shared publications - Vijaya Sunkara
Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
2 shared publications - Bartosz Andrzej Grzybowski
Center for Algorithmic and Robotized Synthesis, Institute for Basic Science (IBS), Ulsan, Republic of Korea
1 shared publication Chi-Ju Kim
Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
1 shared publication
Latest Publications
- 6 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
Reassessing AC/DC Selectivity and Efficiency in Sequential Electroreductions
This paper reassesses the selectivity, efficiency, and mechanism of sequential electroreductions of carbonyl compounds under alternating current (AC) versus direct current (DC) conditions. It reflects the constructive dialogue─through multiple rounds of revisions of the present work─between the Baran group (authors of the original report) and the Grzybowski group (who sought to reproduce the reported phenomena and develop theoretical models). Ultimately, consensus was reached that under the originally described conditions, AC offers no systematic yield or selectivity advantage over DC; side reactions are outcompeted by mass action rather than kinetically suppressed by AC waveforms, while DC is faster and more energy efficient (less F mol–1). Higher AC yields and selectivities can be reached when a small amount of base is added to the sacrificial pivalic acid reductant. This improvement, documented in Baran’s Corrigendum, was confirmed in our own reproductions. However, the addition of base fundamentally alters the originally proposed mechanism: the observed behavior can no longer be attributed to frequency or waveform effects imparted by AC forcing, but is instead explained by mass-action considerations and pH conditions at the electrodes. Moreover, with base present, AC yields and selectivities can still be matched or even surpassed under appropriately optimized DC conditions. These findings (i) clarify the mechanistic origins of the reported phenomena, (ii) establish a transparent framework for choosing between AC and DC electrolysis in future synthetic applications, and (iii) showcase the value of using Machine Learning techniques (here reaction selection aided by Bayesian Optimization) in optimizing electrochemical processes.
- 6 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
Reassessing AC/DC Selectivity and Efficiency in Sequential Electroreductions
This paper reassesses the selectivity, efficiency, and mechanism of sequential electroreductions of carbonyl compounds under alternating current (AC) versus direct current (DC) conditions. It reflects the constructive dialogue─through multiple rounds of revisions of the present work─between the Baran group (authors of the original report) and the Grzybowski group (who sought to reproduce the reported phenomena and develop theoretical models). Ultimately, consensus was reached that under the originally described conditions, AC offers no systematic yield or selectivity advantage over DC; side reactions are outcompeted by mass action rather than kinetically suppressed by AC waveforms, while DC is faster and more energy efficient (less F mol–1). Higher AC yields and selectivities can be reached when a small amount of base is added to the sacrificial pivalic acid reductant. This improvement, documented in Baran’s Corrigendum, was confirmed in our own reproductions. However, the addition of base fundamentally alters the originally proposed mechanism: the observed behavior can no longer be attributed to frequency or waveform effects imparted by AC forcing, but is instead explained by mass-action considerations and pH conditions at the electrodes. Moreover, with base present, AC yields and selectivities can still be matched or even surpassed under appropriately optimized DC conditions. These findings (i) clarify the mechanistic origins of the reported phenomena, (ii) establish a transparent framework for choosing between AC and DC electrolysis in future synthetic applications, and (iii) showcase the value of using Machine Learning techniques (here reaction selection aided by Bayesian Optimization) in optimizing electrochemical processes.
- 29 November 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (49) , 25772-25784
Microfluidic Dielectrophoretic Purification of Extracellular Vesicles from Plasma Lipoproteins
Extracellular vesicles (EVs) are small lipid vesicles shed by cells, carrying proteins, nucleic acids, and other molecular fingerprints. EVs have emerged as crucial mediators of cell-to-cell communication and hold great promise as biomarkers for liquid biopsies, enabling disease screening, diagnosis, prognosis, and monitoring. However, conventional EV separation methods are hampered by the presence of lipoproteins (LPs) in plasma samples, which have comparable characteristics and significantly outnumber EVs. These LPs contaminants complicate downstream analysis, compromising the accuracy of EV-based liquid biopsies. In this study, we present a lab-on-a-chip device that utilizes dielectrophoretic (DEP) separation principles to achieve efficient separation of EVs from LPs. Our method starts with a lab-on-a-disc filtration of human blood plasma gathering similar-sized EVs and LPs, followed by on-disc buffer exchange and subsequent injection into a microfluidic chip containing slanted interdigitated microelectrodes. The DEP force is negative for all EV sizes and positive for all LP sizes at 104 Hz and thus EVs are pushed away and collected at the collection outlet, whereas LPs are flowed down to the waste outlet. This two-step EVs isolation method, size-based filtration followed by DEP-based purification, offers a promising solution for enhancing the quality and accuracy of EV-based liquid biopsies.
- 29 November 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (49) , 25772-25784
Microfluidic Dielectrophoretic Purification of Extracellular Vesicles from Plasma Lipoproteins
Extracellular vesicles (EVs) are small lipid vesicles shed by cells, carrying proteins, nucleic acids, and other molecular fingerprints. EVs have emerged as crucial mediators of cell-to-cell communication and hold great promise as biomarkers for liquid biopsies, enabling disease screening, diagnosis, prognosis, and monitoring. However, conventional EV separation methods are hampered by the presence of lipoproteins (LPs) in plasma samples, which have comparable characteristics and significantly outnumber EVs. These LPs contaminants complicate downstream analysis, compromising the accuracy of EV-based liquid biopsies. In this study, we present a lab-on-a-chip device that utilizes dielectrophoretic (DEP) separation principles to achieve efficient separation of EVs from LPs. Our method starts with a lab-on-a-disc filtration of human blood plasma gathering similar-sized EVs and LPs, followed by on-disc buffer exchange and subsequent injection into a microfluidic chip containing slanted interdigitated microelectrodes. The DEP force is negative for all EV sizes and positive for all LP sizes at 104 Hz and thus EVs are pushed away and collected at the collection outlet, whereas LPs are flowed down to the waste outlet. This two-step EVs isolation method, size-based filtration followed by DEP-based purification, offers a promising solution for enhancing the quality and accuracy of EV-based liquid biopsies.
- Open Access
- 23 January 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (5) , 1351-1366
Recent advances in micro-physiological systems for investigating tumor metastasis and organotropism
MPS technology holds great potential for studying complex metastasis organotropism. It effectively simulates the dynamic interactions between distinct organ environments and the tumor cells, capturing both their inter- and intra-tumor heterogeneity.
- 23 January 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (5) , 1351-1366
Open AccessRecent advances in micro-physiological systems for investigating tumor metastasis and organotropism
MPS technology holds great potential for studying complex metastasis organotropism. It effectively simulates the dynamic interactions between distinct organ environments and the tumor cells, capturing both their inter- and intra-tumor heterogeneity.
- Open Access
- 28 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56807-56819
Exosome Precipitation by Ionic Strength Modulation: ExoPRISM
Extracellular vesicles (EVs) are emerging as crucial materials for precision theragnostic applications. However, current separation methods are time-consuming, costly, and not scalable and deliver limited yields or purity. Here, we present EV precipitation by ionic strength modulation (ExoPRISM), a simple, low-cost, user-friendly, and readily adaptable approach for separating EVs in high yields without compromising their biological functions. Adding an electrolyte solution to blood plasma in small increments generates the sequential precipitation of proteins and EVs, allowing for fractional separation of EVs using low-speed centrifugation. The coprecipitated electrolytes are easily washed away, and the entire EV separation and washing process takes less than an hour. This approach successfully separates EVs from a broad range of volumes and types of biological fluids, including culture medium, urine, plasma, and serum, showing promise as a robust tool for next-generation liquid biopsies and regenerative medicine.
- 28 November 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56807-56819
Open AccessExosome Precipitation by Ionic Strength Modulation: ExoPRISM
Extracellular vesicles (EVs) are emerging as crucial materials for precision theragnostic applications. However, current separation methods are time-consuming, costly, and not scalable and deliver limited yields or purity. Here, we present EV precipitation by ionic strength modulation (ExoPRISM), a simple, low-cost, user-friendly, and readily adaptable approach for separating EVs in high yields without compromising their biological functions. Adding an electrolyte solution to blood plasma in small increments generates the sequential precipitation of proteins and EVs, allowing for fractional separation of EVs using low-speed centrifugation. The coprecipitated electrolytes are easily washed away, and the entire EV separation and washing process takes less than an hour. This approach successfully separates EVs from a broad range of volumes and types of biological fluids, including culture medium, urine, plasma, and serum, showing promise as a robust tool for next-generation liquid biopsies and regenerative medicine.
- Open Access
- 31 July 2023
- Published by Wiley in Advanced Science
- Vol. 10 (27) , e2300164
Organoid‐Based Human Stomach Micro‐Physiological System to Recapitulate the Dynamic Mucosal Defense Mechanism
Several stomach diseases are attributed to the dysregulation of physiological function of gastric mucosal barrier by pathogens. Gastric organoids are a promising tool to develop treatment strategies for gastric infections. However, their functional features of in vivo gastric mucosal barrier and host–microbe interactions are limited due to the lack of physiological stimuli. Herein, a human stomach micro‐physiological system (hsMPS) with physiologically relevant gastric mucosal defense system is described based on the combination of organoid and MPS technology. A fluid flow enhanced epithelial‐mesenchymal interaction in the hsMPS enables functional maturation of gastric epithelial cells, which allows for the recreation of mesh‐like mucus layer containing high level of mucus protective peptides and well‐developed epithelial junctional complexes. Furthermore, gastroprotection mechanisms against Helicobacter pylori (H. pylori) are successfully demonstrated in this system. Therefore, hsMPS represents a new in vitro tool for research where gastric mucosal defense mechanism is pivotal for developing therapeutic strategies.
- 31 July 2023
- Published by Wiley in Advanced Science
- Vol. 10 (27) , e2300164
Open AccessOrganoid‐Based Human Stomach Micro‐Physiological System to Recapitulate the Dynamic Mucosal Defense Mechanism
Several stomach diseases are attributed to the dysregulation of physiological function of gastric mucosal barrier by pathogens. Gastric organoids are a promising tool to develop treatment strategies for gastric infections. However, their functional features of in vivo gastric mucosal barrier and host–microbe interactions are limited due to the lack of physiological stimuli. Herein, a human stomach micro‐physiological system (hsMPS) with physiologically relevant gastric mucosal defense system is described based on the combination of organoid and MPS technology. A fluid flow enhanced epithelial‐mesenchymal interaction in the hsMPS enables functional maturation of gastric epithelial cells, which allows for the recreation of mesh‐like mucus layer containing high level of mucus protective peptides and well‐developed epithelial junctional complexes. Furthermore, gastroprotection mechanisms against Helicobacter pylori (H. pylori) are successfully demonstrated in this system. Therefore, hsMPS represents a new in vitro tool for research where gastric mucosal defense mechanism is pivotal for developing therapeutic strategies.
- 27 October 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (23) , 4707-4715
Fully automated light transmission aggregometry on a disc for platelet function tests
Platelet function tests, a group of assays that measure the ability of platelets to aggregate and promote clotting in a sample of blood, are performed in various medical fields to assess inherited platelet function disorders and monitor antiplatelet therapies. Light transmission aggregometry (LTA) is considered the gold standard for platelet function assessment. However, the lack of a standardized protocol is a major drawback when applied at the point of care. Moreover, it is a time-consuming and labor-intensive assay that requires a large volume of blood. Here, we describe the design, fabrication, and operation of a centrifugal microfluidic disc that can perform a fully automated LTA assay from a small volume of a whole blood sample (via the distinctive structure of the microfluidic chamber, and quick analysis that minimizes the adverse effects of platelet instability.
- 27 October 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (23) , 4707-4715
Fully automated light transmission aggregometry on a disc for platelet function tests
Platelet function tests, a group of assays that measure the ability of platelets to aggregate and promote clotting in a sample of blood, are performed in various medical fields to assess inherited platelet function disorders and monitor antiplatelet therapies. Light transmission aggregometry (LTA) is considered the gold standard for platelet function assessment. However, the lack of a standardized protocol is a major drawback when applied at the point of care. Moreover, it is a time-consuming and labor-intensive assay that requires a large volume of blood. Here, we describe the design, fabrication, and operation of a centrifugal microfluidic disc that can perform a fully automated LTA assay from a small volume of a whole blood sample (via the distinctive structure of the microfluidic chamber, and quick analysis that minimizes the adverse effects of platelet instability.
- Open Access
- 8 October 2021
- Published by Springer Nature in Research Square
SEEDING to enable sensitive electrochemical detection of biomarkers in undiluted biological samples
The interface between an electrode and a liquid plays a critical role in the overall performance of electrochemical biosensors. Surface morphology and roughness affect key parameters, such as the active area, diffusion profiles, and apparent electron transfer kinetics, whereas porosity may hinder the diffusion of fouling proteins. However, there is no simple and rapid method compatible with photolithographic electrodes to generate both nanostructured and porous surfaces. Herein, we demonstrate the interplay between the preferential etching of chloride and surfactant-assisted anisotropic gold reduction to create homogeneous, nanostructured, and nanoporous substrates on photolithographic gold electrodes within a minute and without using templates. We coined this process, SEEDING, that is, Surfactant-based Electrochemical Etch-Deposit Interplay for Nanostructure/Nanopore Growth. SEEDING on electrodes enhanced the sensitivity and anti-biofouling capabilities, enabling direct analysis of small molecules, proteins, and cancer-derived extracellular vesicles in complex biological fluids such as undiluted plasma and urine samples.
- 8 October 2021
- Published by Springer Nature in Research Square
Open AccessSEEDING to enable sensitive electrochemical detection of biomarkers in undiluted biological samples
The interface between an electrode and a liquid plays a critical role in the overall performance of electrochemical biosensors. Surface morphology and roughness affect key parameters, such as the active area, diffusion profiles, and apparent electron transfer kinetics, whereas porosity may hinder the diffusion of fouling proteins. However, there is no simple and rapid method compatible with photolithographic electrodes to generate both nanostructured and porous surfaces. Herein, we demonstrate the interplay between the preferential etching of chloride and surfactant-assisted anisotropic gold reduction to create homogeneous, nanostructured, and nanoporous substrates on photolithographic gold electrodes within a minute and without using templates. We coined this process, SEEDING, that is, Surfactant-based Electrochemical Etch-Deposit Interplay for Nanostructure/Nanopore Growth. SEEDING on electrodes enhanced the sensitivity and anti-biofouling capabilities, enabling direct analysis of small molecules, proteins, and cancer-derived extracellular vesicles in complex biological fluids such as undiluted plasma and urine samples.