Alexander Saunders
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Saunders has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Blüml
Department of Radiology, Children’s Hospital Los Angeles, Los Angeles, USA
3 shared publications - Kevin S. King
Department of Neuroradiology, Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ 85013, USA
2 shared publications - Matthew Borzage
Division of Neonatology, Fetal and Neonatal Institute, Children’s Hospital Los Angeles, Keck School of Medicine
2 shared publications - Benita Tamrazi
Department of Radiology, Children’s Hospital Los Angeles , Los Angeles, California
1 shared publication - J. Gordon McComb
Children’s Hospital Los Angeles
1 shared publication - Jeremy Hughes
Barrow Neurological Institute, Department of Neuroradiology, 350 W Thomas Road, Phoenix, AZ 85013
1 shared publication
Latest Publications
- Open Access
- 14 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1462
Proton MR Spectroscopy of Pediatric Brain Disorders
In vivo MR spectroscopy is a non -invasive methodology that provides information about the biochemistry of tissues. It is available as a “push-button” application on state-of-the-art clinical MR scanners. MR spectroscopy has been used to study various brain diseases including tumors, stroke, trauma, degenerative disorders, epilepsy/seizures, inborn errors, neuropsychiatric disorders, and others. The purpose of this review is to provide an overview of MR spectroscopy findings in the pediatric population and its clinical use.
- 14 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1462
Open AccessProton MR Spectroscopy of Pediatric Brain Disorders
In vivo MR spectroscopy is a non -invasive methodology that provides information about the biochemistry of tissues. It is available as a “push-button” application on state-of-the-art clinical MR scanners. MR spectroscopy has been used to study various brain diseases including tumors, stroke, trauma, degenerative disorders, epilepsy/seizures, inborn errors, neuropsychiatric disorders, and others. The purpose of this review is to provide an overview of MR spectroscopy findings in the pediatric population and its clinical use.
- 7 October 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (11) , 1942-1948
The First Examination of Diagnostic Performance of Automated Measurement of the Callosal Angle in 1856 Elderly Patients and Volunteers Indicates That 12.4% of Exams Met the Criteria for Possible Normal Pressure Hydrocephalus
BACKGROUND AND PURPOSE: Many patients with dementia may have comorbid or misdiagnosed normal pressure hydrocephalus, a treatable neurologic disorder. The callosal angle is a validated biomarker for normal pressure hydrocephalus with 93% diagnostic accuracy. Our purpose was to develop and evaluate an algorithm for automatically computing callosal angles from MR images of the brain. MATERIALS AND METHODS: This article reports the results of analyzing callosal angles from 1856 subjects with 5264 MR images from the Open Access Series of Imaging Studies and the Alzheimer’s Disease Neuroimaging Initiative databases. Measurement variability was examined between 2 neuroradiologists (n = 50) and between manual and automatic measurements (n = 281); from differences in simulated head orientation; and from real-world changes in patients with multiple examinations (n = 906). We evaluated the effectiveness of the automatic callosal angle to differentiate normal pressure hydrocephalus from Alzheimer disease in a simulated cohort. RESULTS: The algorithm identified that 12.4% of subjects from these carefully screened cohorts had callosal angles of <90°, a published threshold for possible normal pressure hydrocephalus. The intraclass correlation coefficient was 0.97 for agreement between neuroradiologists and 0.90 for agreement between manual and automatic measurement. The method was robust to different head orientations. The median coefficient of variation for repeat examinations was 4.2% (Q1 = 3.1%, Q3 = 5.8%). The simulated classification of normal pressure hydrocephalus versus Alzheimer using the automatic callosal angle had an accuracy, sensitivity, and specificity of 0.87 each. CONCLUSIONS: In even the most pristine research databases, analyses of the callosal angle indicate that some patients may have normal pressure hydrocephalus. The automatic callosal angle measurement can rapidly and objectively screen for normal pressure hydrocephalus in patients who would otherwise be misdiagnosed.
- 7 October 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (11) , 1942-1948
The First Examination of Diagnostic Performance of Automated Measurement of the Callosal Angle in 1856 Elderly Patients and Volunteers Indicates That 12.4% of Exams Met the Criteria for Possible Normal Pressure Hydrocephalus
BACKGROUND AND PURPOSE: Many patients with dementia may have comorbid or misdiagnosed normal pressure hydrocephalus, a treatable neurologic disorder. The callosal angle is a validated biomarker for normal pressure hydrocephalus with 93% diagnostic accuracy. Our purpose was to develop and evaluate an algorithm for automatically computing callosal angles from MR images of the brain. MATERIALS AND METHODS: This article reports the results of analyzing callosal angles from 1856 subjects with 5264 MR images from the Open Access Series of Imaging Studies and the Alzheimer’s Disease Neuroimaging Initiative databases. Measurement variability was examined between 2 neuroradiologists (n = 50) and between manual and automatic measurements (n = 281); from differences in simulated head orientation; and from real-world changes in patients with multiple examinations (n = 906). We evaluated the effectiveness of the automatic callosal angle to differentiate normal pressure hydrocephalus from Alzheimer disease in a simulated cohort. RESULTS: The algorithm identified that 12.4% of subjects from these carefully screened cohorts had callosal angles of <90°, a published threshold for possible normal pressure hydrocephalus. The intraclass correlation coefficient was 0.97 for agreement between neuroradiologists and 0.90 for agreement between manual and automatic measurement. The method was robust to different head orientations. The median coefficient of variation for repeat examinations was 4.2% (Q1 = 3.1%, Q3 = 5.8%). The simulated classification of normal pressure hydrocephalus versus Alzheimer using the automatic callosal angle had an accuracy, sensitivity, and specificity of 0.87 each. CONCLUSIONS: In even the most pristine research databases, analyses of the callosal angle indicate that some patients may have normal pressure hydrocephalus. The automatic callosal angle measurement can rapidly and objectively screen for normal pressure hydrocephalus in patients who would otherwise be misdiagnosed.
- 28 April 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (02) , 024005-23
Algorithms for segmenting cerebral time-of-flight magnetic resonance angiograms from volunteers and anemic patients
Purpose: To evaluate six cerebral arterial segmentation algorithms in a set of patients with a wide range of hemodynamic characteristics to determine real-world performance. Approach: Time-of-flight magnetic resonance angiograms were acquired from 33 subjects: normal controls (N = 11), sickle cell disease (N = 11), and non-sickle anemia (N = 11) using a 3 Tesla Philips Achieva scanner. Six segmentation algorithms were tested: (1) Otsu’s method, (2) K-means, (3) region growing, (4) active contours, (5) minimum cost path, and (6) U-net machine learning. Segmentation algorithms were tested with two region-selection methods: global, which selects the entire volume; and local, which iteratively tracks the arteries. Five slices were manually segmented from each patient by two readers. Agreement between manual and automatic segmentation was measured using Matthew’s correlation coefficient (MCC). Results: Median algorithm segmentation times ranged from 0.1 to 172.9 s for a single angiogram versus 10 h for manual segmentation. Algorithms had inferior performance to inter-observer vessel-based (p < 0.0001, MCC = 0.65) and voxel-based (p < 0.0001, MCC = 0.73) measurements. There were significant differences between algorithms (p < 0.0001) and between patients (p < 0.0042). Post-hoc analyses indicated (1) local minimum cost path performed best with vessel-based (p = 0.0261, MCC = 0.50) and voxel-based (p = 0.0131, MCC = 0.66) analyses; and (2) higher vessel-based performance in non-sickle anemia (p = 0.0002) and lower voxel-based performance in sickle cell (p = 0.0422) compared with normal controls. All reported MCCs are medians. Conclusions: The best-performing algorithm (local minimum cost path, voxel-based) had 9.59% worse performance than inter-observer agreement but was 3 orders of magnitude faster. Automatic segmentation was non-inferior in patients with sickle cell disease and superior in non-sickle anemia.
- 28 April 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (02) , 024005-23
Algorithms for segmenting cerebral time-of-flight magnetic resonance angiograms from volunteers and anemic patients
Purpose: To evaluate six cerebral arterial segmentation algorithms in a set of patients with a wide range of hemodynamic characteristics to determine real-world performance. Approach: Time-of-flight magnetic resonance angiograms were acquired from 33 subjects: normal controls (N = 11), sickle cell disease (N = 11), and non-sickle anemia (N = 11) using a 3 Tesla Philips Achieva scanner. Six segmentation algorithms were tested: (1) Otsu’s method, (2) K-means, (3) region growing, (4) active contours, (5) minimum cost path, and (6) U-net machine learning. Segmentation algorithms were tested with two region-selection methods: global, which selects the entire volume; and local, which iteratively tracks the arteries. Five slices were manually segmented from each patient by two readers. Agreement between manual and automatic segmentation was measured using Matthew’s correlation coefficient (MCC). Results: Median algorithm segmentation times ranged from 0.1 to 172.9 s for a single angiogram versus 10 h for manual segmentation. Algorithms had inferior performance to inter-observer vessel-based (p < 0.0001, MCC = 0.65) and voxel-based (p < 0.0001, MCC = 0.73) measurements. There were significant differences between algorithms (p < 0.0001) and between patients (p < 0.0042). Post-hoc analyses indicated (1) local minimum cost path performed best with vessel-based (p = 0.0261, MCC = 0.50) and voxel-based (p = 0.0131, MCC = 0.66) analyses; and (2) higher vessel-based performance in non-sickle anemia (p = 0.0002) and lower voxel-based performance in sickle cell (p = 0.0422) compared with normal controls. All reported MCCs are medians. Conclusions: The best-performing algorithm (local minimum cost path, voxel-based) had 9.59% worse performance than inter-observer agreement but was 3 orders of magnitude faster. Automatic segmentation was non-inferior in patients with sickle cell disease and superior in non-sickle anemia.