Pengfei Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pengfei Sun has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Meng Huang
Wuhan University
7 shared publications - Xiaoming Zha
Wuhan University
7 shared publications - Zhen Tian
Wuhan University
7 shared publications - Xilin Li
Wuhan University
5 shared publications Yufei Hu
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
2 shared publicationsBoyan Hao
Beijing Jiaotong University
1 shared publication
Latest Publications
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 626-636
Power Supporting Control of Grid-Forming Converters Under Grid Voltage Sags for Transient Stability Enhancement and Overcurrent Limitation
There is an increasing demand for grid-forming controlled voltage source converters (GFM-VSC). However, to maintain its voltage source characteristics, the GFM-VSC under grid voltage sags may face the conflicts between transient stability enhancement and overcurrent limitation. In this paper, the power supporting control method is proposed for GFM-VSC to solve this conflict by tuning the active power and voltage magnitude reference. The active power reference is introduced as an extra variable, therefore, the power angle during grid fault and the voltage magnitude can be tuned in the same time to increase the design of freedom. Firstly, the feasible region for power angle and voltage magnitude is shaped considering the constraints in transient stability and current limiting. Under the constraint of feasible region, three optimal control modes are designed to determine the power and voltage reference, concluding the maximum active power, maximum reactive power control and optimal transient control modes. Finally, the performance of the proposed control method is verified by experimental results. Compared with existing fault ride-through methods, the proposed method could achieve higher power supporting capability while maintaining the voltage source characteristics, since which makes full utilization of power angle and voltage boundaries.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 626-636
Power Supporting Control of Grid-Forming Converters Under Grid Voltage Sags for Transient Stability Enhancement and Overcurrent Limitation
There is an increasing demand for grid-forming controlled voltage source converters (GFM-VSC). However, to maintain its voltage source characteristics, the GFM-VSC under grid voltage sags may face the conflicts between transient stability enhancement and overcurrent limitation. In this paper, the power supporting control method is proposed for GFM-VSC to solve this conflict by tuning the active power and voltage magnitude reference. The active power reference is introduced as an extra variable, therefore, the power angle during grid fault and the voltage magnitude can be tuned in the same time to increase the design of freedom. Firstly, the feasible region for power angle and voltage magnitude is shaped considering the constraints in transient stability and current limiting. Under the constraint of feasible region, three optimal control modes are designed to determine the power and voltage reference, concluding the maximum active power, maximum reactive power control and optimal transient control modes. Finally, the performance of the proposed control method is verified by experimental results. Compared with existing fault ride-through methods, the proposed method could achieve higher power supporting capability while maintaining the voltage source characteristics, since which makes full utilization of power angle and voltage boundaries.
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 2780-2796
Hybrid Power Synchronization Based Transient Stability Enhanced Control for Grid-Forming Inverters Under Symmetrical Grid Fault
The current limiter can effectively limit the overcurrent for grid forming (GFM) inverter, but it also makes the inverter easier to lose the stable equilibrium point (SEP) during grid fault. The untimely fault clearing, inaccurate fault depth detection and grid impedance measurement result may lead to overoptimistic deceleration effect evaluation and transient instability problem. In this article, the hybrid power synchronization method is proposed to increase the robustness in transient stability of the GFM inverter against parameters variation. The reactive power that internally related to fault depth is introduced as the dynamic active power reference. It can make sure that the SEP exist during grid fault without the need of fault depth detection. In the same time, the dynamic power compensation related to fault depth is also achieved. The reactive power feedback gain optimization and equivalent power reference limitation method are further given to increase the robustness against large impedance measurement error. Based on equal area criterion, it is demonstrated that with the proposed hybrid power synchronization method, the transient stability of GFM voltage source converter always can be guaranteed once the SEP exists. The impact of line-to-ground fault on transient stability is analyzed and the robust enhanced method is also given. Finally, the effectiveness of the proposed method is verified on a 5 kW experimental platform.
- 14 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 2780-2796
Hybrid Power Synchronization Based Transient Stability Enhanced Control for Grid-Forming Inverters Under Symmetrical Grid Fault
The current limiter can effectively limit the overcurrent for grid forming (GFM) inverter, but it also makes the inverter easier to lose the stable equilibrium point (SEP) during grid fault. The untimely fault clearing, inaccurate fault depth detection and grid impedance measurement result may lead to overoptimistic deceleration effect evaluation and transient instability problem. In this article, the hybrid power synchronization method is proposed to increase the robustness in transient stability of the GFM inverter against parameters variation. The reactive power that internally related to fault depth is introduced as the dynamic active power reference. It can make sure that the SEP exist during grid fault without the need of fault depth detection. In the same time, the dynamic power compensation related to fault depth is also achieved. The reactive power feedback gain optimization and equivalent power reference limitation method are further given to increase the robustness against large impedance measurement error. Based on equal area criterion, it is demonstrated that with the proposed hybrid power synchronization method, the transient stability of GFM voltage source converter always can be guaranteed once the SEP exists. The impact of line-to-ground fault on transient stability is analyzed and the robust enhanced method is also given. Finally, the effectiveness of the proposed method is verified on a 5 kW experimental platform.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8007-8023
Additional Kinetic Energy Injection and Piecewise Damping Based Postfault Antiwindup and Transient Stability Enhanced Control for Grid-Forming Inverter
The transient instability mechanism and enhanced control for Grid-Forming controlled voltage source converter (GFM-VSC) during voltage sags has been widely investigated. However, the postfault performance are overlooked in the previous studies. In this paper, the postfault transient instability and windup problem of GFM-VSC with virtual inertia is first revealed based on established piecewise nonlinear model and power angle curve. Second, the impact of key parameters on postfault transient stability and windup phenomenon and the impact mechanism is analyzed, revealing that the conventional deceleration effect enhancement method increase the postfault transient stability, but increase the risk of windup problem. Third, the torque error and q -axis voltage feedforward based hybrid synchronization method is adopted to achieve transient stability enhancement and anti-windup. Different from the conventional global deceleration effect enhancement, the adopted control method can inject extra kinetic energy during first current saturation mode and extra damping during current unsaturation state, therefore, the global deceleration effect can be enhanced and the local deceleration effect in the first current saturation period can be deteriorated. Then, the anti-windup and transient stability enhancement is achieved. Finally, the analysis and effectiveness of the designed control strategy has been verified on a 500W experimental prototype.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (7) , 8007-8023
Additional Kinetic Energy Injection and Piecewise Damping Based Postfault Antiwindup and Transient Stability Enhanced Control for Grid-Forming Inverter
The transient instability mechanism and enhanced control for Grid-Forming controlled voltage source converter (GFM-VSC) during voltage sags has been widely investigated. However, the postfault performance are overlooked in the previous studies. In this paper, the postfault transient instability and windup problem of GFM-VSC with virtual inertia is first revealed based on established piecewise nonlinear model and power angle curve. Second, the impact of key parameters on postfault transient stability and windup phenomenon and the impact mechanism is analyzed, revealing that the conventional deceleration effect enhancement method increase the postfault transient stability, but increase the risk of windup problem. Third, the torque error and q -axis voltage feedforward based hybrid synchronization method is adopted to achieve transient stability enhancement and anti-windup. Different from the conventional global deceleration effect enhancement, the adopted control method can inject extra kinetic energy during first current saturation mode and extra damping during current unsaturation state, therefore, the global deceleration effect can be enhanced and the local deceleration effect in the first current saturation period can be deteriorated. Then, the anti-windup and transient stability enhancement is achieved. Finally, the analysis and effectiveness of the designed control strategy has been verified on a 500W experimental prototype.
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (2) , 1110-1123
A Conservatism Improved Transient Stability Analysis of Grid-Following Converters Based on the Proposed Elliptic-Equal Area Criterion
The power electronics’ penetration in modern grids is rapidly increasing due to the growing proportion of renewable energy generation. As the important energy conversion interface, the stable operation of grid-tied converters is vital to the overall safe of the double-high power system. The prior arts have mainly focused on the varying negative damping in the phase-locked loop (PLL). Negative damping imposes energy into the system and is detrimental to system's transient stability and should not be neglected as the constant positive damping in synchronous generators. The deficiencies of the previous studies lie in the large conservatism of the criteria once considering the influence of negative damping. In this article, an elliptic-equal area criterion (EAC) is proposed to assess the damping impacts on the stable domain of the converter systems, which improves conservatism compared to previous transient stability criteria. In addition, a transient stability improved PLL is proposed by eliminating the negative damping term.
- 3 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (2) , 1110-1123
A Conservatism Improved Transient Stability Analysis of Grid-Following Converters Based on the Proposed Elliptic-Equal Area Criterion
The power electronics’ penetration in modern grids is rapidly increasing due to the growing proportion of renewable energy generation. As the important energy conversion interface, the stable operation of grid-tied converters is vital to the overall safe of the double-high power system. The prior arts have mainly focused on the varying negative damping in the phase-locked loop (PLL). Negative damping imposes energy into the system and is detrimental to system's transient stability and should not be neglected as the constant positive damping in synchronous generators. The deficiencies of the previous studies lie in the large conservatism of the criteria once considering the influence of negative damping. In this article, an elliptic-equal area criterion (EAC) is proposed to assess the damping impacts on the stable domain of the converter systems, which improves conservatism compared to previous transient stability criteria. In addition, a transient stability improved PLL is proposed by eliminating the negative damping term.
- Top Cited Papers
- 28 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (4) , 4463-4476
Transient Synchronization Stability of an Islanded AC Microgrid Considering Interactions Between Grid-Forming and Grid-Following Converters
Microgrid has been rapidly developed for the integration of distributed renewable energy, owing to its superiority of flexible operation and high reliability. Without frequency support from the main grid, the microgrid under islanded operating mode is more likely to lose stability in the presence of large-signal disturbances. However, previous studies mainly focus on weak grid conditions and ignore the interaction effects between different-type converters. Therefore, this paper investigates the transient synchronization stability of an islanded AC microgrid considering dynamic interactions between grid-forming and grid-following converters. Firstly, a simplified nonlinear model of the islanded microgrid is established, which reveals the nonlinear interaction and damping impact on system stability. Based on the passivity principle and LaSalle’s theorem, an explicit stability criterion is formulated to reveal the instability mechanism. With the proposed stability criterion, the impacts of different system parameters are analyzed, which points out the direction of parameters optimization to enhance stability. To validate the effectiveness of the proposed method, simulations and experiments are carried out.
- 28 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (4) , 4463-4476
Top Cited PapersTransient Synchronization Stability of an Islanded AC Microgrid Considering Interactions Between Grid-Forming and Grid-Following Converters
Microgrid has been rapidly developed for the integration of distributed renewable energy, owing to its superiority of flexible operation and high reliability. Without frequency support from the main grid, the microgrid under islanded operating mode is more likely to lose stability in the presence of large-signal disturbances. However, previous studies mainly focus on weak grid conditions and ignore the interaction effects between different-type converters. Therefore, this paper investigates the transient synchronization stability of an islanded AC microgrid considering dynamic interactions between grid-forming and grid-following converters. Firstly, a simplified nonlinear model of the islanded microgrid is established, which reveals the nonlinear interaction and damping impact on system stability. Based on the passivity principle and LaSalle’s theorem, an explicit stability criterion is formulated to reveal the instability mechanism. With the proposed stability criterion, the impacts of different system parameters are analyzed, which points out the direction of parameters optimization to enhance stability. To validate the effectiveness of the proposed method, simulations and experiments are carried out.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (6) , 7746-7759
Nonlinear Modeling and Stability Analysis of Grid-Tied Paralleled-Converters Systems Based on the Proposed Dual-Iterative Equal Area Criterion
With the rapid development of distributed renewable energy generation and integration, stability issues of power converters systems have been widely studied in recent years. Many previous studies focus on the transient stability of a single converter connected to the weak grid. However, the nonlinear dynamics and stability mechanism of multiple converters systems remain unclear. In this article, a unified nonlinear model of the paralleled-converters system is established, which reveals the interactive power and interactive damping among multiple converters and the weak grid. To analyze the impacts of the interactive power and damping terms on system stability, a dual-iterative equal area criterion (DITEAC) is proposed with a dual-layer iterative calculation of the accelerating area and decelerating area. Compared with the previous studies, the proposed DITEAC method could deal with the nonlinear interactive damping and reduce the conservatism caused by the inequality scaling, which greatly improves the calculation accuracy of stability boundaries. The expansion feasibility of the proposed unified nonlinear model and DITEAC method to the N -converters system is fully discussed. Eventually, simulation and hardware-in-loop experiment results are presented to verify the effectiveness of the proposed method.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (6) , 7746-7759
Nonlinear Modeling and Stability Analysis of Grid-Tied Paralleled-Converters Systems Based on the Proposed Dual-Iterative Equal Area Criterion
With the rapid development of distributed renewable energy generation and integration, stability issues of power converters systems have been widely studied in recent years. Many previous studies focus on the transient stability of a single converter connected to the weak grid. However, the nonlinear dynamics and stability mechanism of multiple converters systems remain unclear. In this article, a unified nonlinear model of the paralleled-converters system is established, which reveals the interactive power and interactive damping among multiple converters and the weak grid. To analyze the impacts of the interactive power and damping terms on system stability, a dual-iterative equal area criterion (DITEAC) is proposed with a dual-layer iterative calculation of the accelerating area and decelerating area. Compared with the previous studies, the proposed DITEAC method could deal with the nonlinear interactive damping and reduce the conservatism caused by the inequality scaling, which greatly improves the calculation accuracy of stability boundaries. The expansion feasibility of the proposed unified nonlinear model and DITEAC method to the N -converters system is fully discussed. Eventually, simulation and hardware-in-loop experiment results are presented to verify the effectiveness of the proposed method.
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 1771-1784
An Iterative Equal Area Criterion for Transient Stability Analysis of Grid-Tied Converter Systems With Varying Damping
With the increasing penetration of renewable energy generators, the stability issues of grid-tied converter systems become much more important. However, due to the high nonlinearity and varying damping of converter systems, conventional transient stability analysis methods are not applicable, which may bring to conservativeness or misjudgment on stability assessment. In this paper, the transient stability of grid-tied converter systems with varying damping is investigated to provide stability boundary estimation. Firstly, considering the frequency mutation of the phase-locked loop (PLL) caused by various perturbations, a modified swing equation model of grid-tied converter systems is built, which greatly improves the mathematical model accuracy under transient disturbances. To evaluate the impacts of varying damping and frequency mutation, an iterative equal area criterion (ITEAC) method is proposed with the iterative calculation of the accelerating and decelerating area, which renders stability boundaries with high accuracy. Moreover, the impacts of controller and system parameters on stability boundaries are quantitatively analyzed. Eventually, simulation and hardware-in-loop experiments are performed to verify the effectiveness and superiority of the proposed ITEAC.
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 1771-1784
An Iterative Equal Area Criterion for Transient Stability Analysis of Grid-Tied Converter Systems With Varying Damping
With the increasing penetration of renewable energy generators, the stability issues of grid-tied converter systems become much more important. However, due to the high nonlinearity and varying damping of converter systems, conventional transient stability analysis methods are not applicable, which may bring to conservativeness or misjudgment on stability assessment. In this paper, the transient stability of grid-tied converter systems with varying damping is investigated to provide stability boundary estimation. Firstly, considering the frequency mutation of the phase-locked loop (PLL) caused by various perturbations, a modified swing equation model of grid-tied converter systems is built, which greatly improves the mathematical model accuracy under transient disturbances. To evaluate the impacts of varying damping and frequency mutation, an iterative equal area criterion (ITEAC) method is proposed with the iterative calculation of the accelerating and decelerating area, which renders stability boundaries with high accuracy. Moreover, the impacts of controller and system parameters on stability boundaries are quantitatively analyzed. Eventually, simulation and hardware-in-loop experiments are performed to verify the effectiveness and superiority of the proposed ITEAC.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (3) , 3650-3667
Simultaneous Wireless Power and Data Transfer: A Comprehensive Review
Simultaneous wireless power and data transfer (SWPDT) is widely investigated because of the increasing requirement for real-time communication between the primary and secondary sides in wireless power transfer systems. This article classifies SWPDT systems into four categories according to the type and number of data channels and data carrier generation method. They are power carrier-based SWPDT system, high-frequency data carrier-based SWPDT system, multiple inductive channels SWPDT system, and inductive–capacitive hybrid channels SWPDT system, respectively. Four key issues, including cross-talk minimization, improvement of signal-to-noise ratio, modulation method for high data rate and low bit error rate, and special design to achieve full-duplex communication and improve misalignment tolerance, are discussed. The advantages, disadvantages, and applications of the four types of SWPDT systems are summarized. Finally, conclusions and outlook of the SWPDT system are given.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (3) , 3650-3667
Simultaneous Wireless Power and Data Transfer: A Comprehensive Review
Simultaneous wireless power and data transfer (SWPDT) is widely investigated because of the increasing requirement for real-time communication between the primary and secondary sides in wireless power transfer systems. This article classifies SWPDT systems into four categories according to the type and number of data channels and data carrier generation method. They are power carrier-based SWPDT system, high-frequency data carrier-based SWPDT system, multiple inductive channels SWPDT system, and inductive–capacitive hybrid channels SWPDT system, respectively. Four key issues, including cross-talk minimization, improvement of signal-to-noise ratio, modulation method for high data rate and low bit error rate, and special design to achieve full-duplex communication and improve misalignment tolerance, are discussed. The advantages, disadvantages, and applications of the four types of SWPDT systems are summarized. Finally, conclusions and outlook of the SWPDT system are given.
- 4 April 2020
- Published by Springer Nature
- p. 273-281
K-Step Fault Propagation Method for High-Speed Train System
- 4 April 2020
- Published by Springer Nature
- p. 273-281
K-Step Fault Propagation Method for High-Speed Train System
- 21 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Wireless Communications
- Vol. 9 (12) , 3613-3619
Carrier Frequency Offset Tracking in the IEEE 802.16e OFDMA Uplink
The IEEE 802.16e standard for nomadic wireless metropolitan area networks adopts orthogonal frequency-division multiple-access (OFDMA) as an air interface. In these systems, residual carrier frequency offsets (CFOs) between the uplink signals and the base station local oscillator give rise to interchannel interference (ICI) as well as multiple access interference (MAI). Accurate CFO estimation and compensation is thus necessary to avoid a serious degradation of the error-rate performance. In this work, we address the problem of CFO tracking in the IEEE 802.16e uplink and present a closed-loop solution based on the least-squares (LS) principle. In doing so, we exploit a set of pilot tones that are available in each user's subchannel. The resulting scheme can be implemented with affordable complexity and is able to reliably track the CFOs of all active users. When used in conjunction with a frequency offset compensator, it can effectively mitigate ICI and MAI, thereby allowing channel equalization and data detection to follow directly. Numerical simulations are used to demonstrate the effectiveness of the proposed solution in the presence of residual time-varying frequency offsets.
- 21 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Wireless Communications
- Vol. 9 (12) , 3613-3619
Carrier Frequency Offset Tracking in the IEEE 802.16e OFDMA Uplink
The IEEE 802.16e standard for nomadic wireless metropolitan area networks adopts orthogonal frequency-division multiple-access (OFDMA) as an air interface. In these systems, residual carrier frequency offsets (CFOs) between the uplink signals and the base station local oscillator give rise to interchannel interference (ICI) as well as multiple access interference (MAI). Accurate CFO estimation and compensation is thus necessary to avoid a serious degradation of the error-rate performance. In this work, we address the problem of CFO tracking in the IEEE 802.16e uplink and present a closed-loop solution based on the least-squares (LS) principle. In doing so, we exploit a set of pilot tones that are available in each user's subchannel. The resulting scheme can be implemented with affordable complexity and is able to reliably track the CFOs of all active users. When used in conjunction with a frequency offset compensator, it can effectively mitigate ICI and MAI, thereby allowing channel equalization and data detection to follow directly. Numerical simulations are used to demonstrate the effectiveness of the proposed solution in the presence of residual time-varying frequency offsets.