Kyle A. Kainec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kyle A. Kainec has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Rebecca M. C. Spencer
University of Massachusetts Amherst
5 shared publications - Ahren B. Fitzroy
University of Massachusetts, Amherst, USA
2 shared publications - Daniel M. Merfeld
The Ohio State University Wexner Medical Center
2 shared publications - Abdul Wasay Paracha
Office of Medical Education, Penn State University College of Medicine, Hershey, PA
1 shared publication Allison Ludwig
Leidos, Health Solutions, Reston, VA, USA
1 shared publication- Annika Berlin
Institute for Applied Life Sciences, Life Science Laboratories, University of Massachusetts Amherst, 240 Thatcher Road, Amherst, MA 01003, USA
1 shared publication
Latest Publications
- 29 August 2026
- Published by SAGE Publications in Journal of Vestibular Research
Hypoxia increases vertical translation thresholds in patients with unilateral vestibular hypofunction
Hypoxia when breathing air with the percentage of inspired oxygen (% O 2 ) reduced has been shown to diminish sensory, motor, and cognitive function. We recently showed that hypoxia experienced while inspiring air with 15.4% O 2 decreased sensitivity to upward and downward motions (Z-Translations). Here, we follow-up with similar Z-Translation perceptual threshold testing in 5 patients with unilateral vestibular hypofunction. All testing was completed at an altitude of 820 ft (249 m). Each patient completed Z-Translation vestibular threshold testing with inspired % O 2 set to 20.9%, 17.9%, 16.6%, and 15.4% to mimic the effects of altitudes of 820 ft, 4000 ft, 6000 ft, or 8000 ft (249 m, 1219 m, 1828 m, or 2438 m), respectively. Z-Translation thresholds significantly increased in the hypoxic conditions (F (3,88) = 8.29, p = 6.48 × 10 −5 ). Further, greater reductions in peripheral oxygen saturation (SpO 2 ) significantly predicted higher Z-Translation thresholds (estimated slope = 0.67 cm/s/%, t (73.37) = −2.83, p = 0.006). These results provide evidence that sensing whole-body motion is susceptible to hypoxia. Extra precautions and countermeasures may be warranted for people experiencing mild reductions in blood oxygenation – especially patients with vestibular hypofunction – while performing tasks that require balance and/or accurate and precise spatial orientation.
- 29 August 2026
- Published by SAGE Publications in Journal of Vestibular Research
Hypoxia increases vertical translation thresholds in patients with unilateral vestibular hypofunction
Hypoxia when breathing air with the percentage of inspired oxygen (% O 2 ) reduced has been shown to diminish sensory, motor, and cognitive function. We recently showed that hypoxia experienced while inspiring air with 15.4% O 2 decreased sensitivity to upward and downward motions (Z-Translations). Here, we follow-up with similar Z-Translation perceptual threshold testing in 5 patients with unilateral vestibular hypofunction. All testing was completed at an altitude of 820 ft (249 m). Each patient completed Z-Translation vestibular threshold testing with inspired % O 2 set to 20.9%, 17.9%, 16.6%, and 15.4% to mimic the effects of altitudes of 820 ft, 4000 ft, 6000 ft, or 8000 ft (249 m, 1219 m, 1828 m, or 2438 m), respectively. Z-Translation thresholds significantly increased in the hypoxic conditions (F (3,88) = 8.29, p = 6.48 × 10 −5 ). Further, greater reductions in peripheral oxygen saturation (SpO 2 ) significantly predicted higher Z-Translation thresholds (estimated slope = 0.67 cm/s/%, t (73.37) = −2.83, p = 0.006). These results provide evidence that sensing whole-body motion is susceptible to hypoxia. Extra precautions and countermeasures may be warranted for people experiencing mild reductions in blood oxygenation – especially patients with vestibular hypofunction – while performing tasks that require balance and/or accurate and precise spatial orientation.
- Open Access
- 1 May 2026
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 18, 1-19
Earth Vertical Motions Disrupt Sleep and Next Day Performance
Purpose: Overcoming travel-related sleep disturbances due to motions sensed by our vestibular system could help improve cognitive performance and sleep quality in many contexts. However, there is a lack of research that administers controlled motions to understand how motion negatively impacts sleep and cognitive performance. Patients and Methods: In this experiment, nine participants (21– 39 years, M = 30.3, SD = 6.76; 3 females) completed a 7-day protocol. During nights 1– 3, participants wore an Actiwatch and completed sleep diaries at home. On nights 4– 7, participants slept in the lab with polysomnographic recording equipment on a bed attached to a movement platform and completed a psychomotor vigilance test at 07:00AM, 1:00PM, 3:00PM, and 5:00PM. On nights 4 and 5, the bed did not move overnight. On nights 6 and 7, the bed was moved upward and downward at 1Hz up to 120 times overnight at levels between 0– 100% and 0– 600% of each participant’s awake perceptual vertical motion threshold, respectively. Results: Vertical motions significantly increased arousals from sleep (p =0.014) and worsened morning and midday psychomotor vigilance (p < 0.001). Arousals caused by vertical motions occurred less than natural arousals (p < 0.001) and had different spectral power (p =0.002). Larger motions strongly and significantly predicted a higher chance of causing arousals (β =0.0016, p < 0.001). Conclusion: These results provide evidence that overnight vertical motions disrupt sleep, lead to arousals that are distinct from natural arousals, and result in decreased cognitive performance. Strategies to reduce motion could help mitigate travel-related sleep disturbances. Plain Language Summary: Travel related sleep disturbances are prevalent but poorly understood. The results of this study provide evidence that vertical motions disrupt sleep, lead to arousals that are distinct from natural arousals, and result in decreased cognitive performance. Strategies to reduce the number and size of vertical motions may help overcome travel-related sleep disturbances. However, whether and how motion size, frequency, and direction impact brain processes, sleep, and cognitive performance remain critical knowledge gaps. Future studies examining stronger motions administered more frequently to a larger number of participants are needed. Further, the topographic and time-frequency EEG profiles of natural and motion related arousals need to be further examined to better understand how the brain processes motion during sleep. Earth-vertical motions during sleep: 1) Decreased next day cognitive performance. Bar graph with legend: Acclimation, Baseline, 0-100 percent, 0-600 percent. X-axis: Condition (unit not shown) with 1, 2, 3, 4. Y-axis: Lapses (Average Count) (unit not shown), range 0 to 7.5 with ticks 0, 2.5, 5.0, 7.5. Bar heights: condition 1 about 2; condition 2 about 3; condition 3 about 4.2; condition 4 about 6.5. 2) Increased how many arousals occurred overnight. Bar graph with same legend. X-axis: Condition (unit not shown) with 1, 2, 3, 4. Y-axis: Arousals (Average Count) (unit not shown), range 0 to 100 with ticks 0, 25, 50, 75, 100. Bar heights: condition 1 about 85; condition 2 about 60; condition 3 about 90; condition 4 about 98. 3) Caused arousals that were different than natural arousals. Line graph with legend: Motion-Related and Natural. X-axis: Frequency (unit not shown), range 0 to 32 with ticks 0, 8, 16, 24, 32. Y-axis: Spectral Power (microvolt superscript 2 over hertz), range negative 10 to 40 with ticks negative 10, 0, 10, 20, 30, 40. Both curves decrease from about 25 to 30 at frequency 0 toward about negative 10 near frequency 32, with the Motion-Related and Natural curves closely tracking each other across the frequency range. 4) Caused a greater proportion of arousals as motion magnitude increased. Scatter plot with a fitted line and band. X-axis: Percent of Threshold (percent), range 0 to 600 with ticks 0, 200, 400, 600. Y-axis: Proportion of Arousals (unit not shown), range 0 to 1.0 with ticks 0, 0.25, 0.50, 0.75, 1.0. Points span x about 0 to 600 and y 0 to 1.0 and the fitted line increases from lower y values at low percent of threshold to higher y values at higher percent of threshold. Text: beta equals .0016; standard error equals 0.0001; p less than .001. Across the four graphs, Condition-based comparisons of lapses and arousals are paired with frequency-domain spectral power curves and a percent-of-threshold relationship for arousal proportion.Four graphs showing sleep motion effects on lapses, arousals, spectral power and arousal proportion.
- 1 May 2026
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 18, 1-19
Open AccessEarth Vertical Motions Disrupt Sleep and Next Day Performance
Purpose: Overcoming travel-related sleep disturbances due to motions sensed by our vestibular system could help improve cognitive performance and sleep quality in many contexts. However, there is a lack of research that administers controlled motions to understand how motion negatively impacts sleep and cognitive performance. Patients and Methods: In this experiment, nine participants (21– 39 years, M = 30.3, SD = 6.76; 3 females) completed a 7-day protocol. During nights 1– 3, participants wore an Actiwatch and completed sleep diaries at home. On nights 4– 7, participants slept in the lab with polysomnographic recording equipment on a bed attached to a movement platform and completed a psychomotor vigilance test at 07:00AM, 1:00PM, 3:00PM, and 5:00PM. On nights 4 and 5, the bed did not move overnight. On nights 6 and 7, the bed was moved upward and downward at 1Hz up to 120 times overnight at levels between 0– 100% and 0– 600% of each participant’s awake perceptual vertical motion threshold, respectively. Results: Vertical motions significantly increased arousals from sleep (p =0.014) and worsened morning and midday psychomotor vigilance (p < 0.001). Arousals caused by vertical motions occurred less than natural arousals (p < 0.001) and had different spectral power (p =0.002). Larger motions strongly and significantly predicted a higher chance of causing arousals (β =0.0016, p < 0.001). Conclusion: These results provide evidence that overnight vertical motions disrupt sleep, lead to arousals that are distinct from natural arousals, and result in decreased cognitive performance. Strategies to reduce motion could help mitigate travel-related sleep disturbances. Plain Language Summary: Travel related sleep disturbances are prevalent but poorly understood. The results of this study provide evidence that vertical motions disrupt sleep, lead to arousals that are distinct from natural arousals, and result in decreased cognitive performance. Strategies to reduce the number and size of vertical motions may help overcome travel-related sleep disturbances. However, whether and how motion size, frequency, and direction impact brain processes, sleep, and cognitive performance remain critical knowledge gaps. Future studies examining stronger motions administered more frequently to a larger number of participants are needed. Further, the topographic and time-frequency EEG profiles of natural and motion related arousals need to be further examined to better understand how the brain processes motion during sleep. Earth-vertical motions during sleep: 1) Decreased next day cognitive performance. Bar graph with legend: Acclimation, Baseline, 0-100 percent, 0-600 percent. X-axis: Condition (unit not shown) with 1, 2, 3, 4. Y-axis: Lapses (Average Count) (unit not shown), range 0 to 7.5 with ticks 0, 2.5, 5.0, 7.5. Bar heights: condition 1 about 2; condition 2 about 3; condition 3 about 4.2; condition 4 about 6.5. 2) Increased how many arousals occurred overnight. Bar graph with same legend. X-axis: Condition (unit not shown) with 1, 2, 3, 4. Y-axis: Arousals (Average Count) (unit not shown), range 0 to 100 with ticks 0, 25, 50, 75, 100. Bar heights: condition 1 about 85; condition 2 about 60; condition 3 about 90; condition 4 about 98. 3) Caused arousals that were different than natural arousals. Line graph with legend: Motion-Related and Natural. X-axis: Frequency (unit not shown), range 0 to 32 with ticks 0, 8, 16, 24, 32. Y-axis: Spectral Power (microvolt superscript 2 over hertz), range negative 10 to 40 with ticks negative 10, 0, 10, 20, 30, 40. Both curves decrease from about 25 to 30 at frequency 0 toward about negative 10 near frequency 32, with the Motion-Related and Natural curves closely tracking each other across the frequency range. 4) Caused a greater proportion of arousals as motion magnitude increased. Scatter plot with a fitted line and band. X-axis: Percent of Threshold (percent), range 0 to 600 with ticks 0, 200, 400, 600. Y-axis: Proportion of Arousals (unit not shown), range 0 to 1.0 with ticks 0, 0.25, 0.50, 0.75, 1.0. Points span x about 0 to 600 and y 0 to 1.0 and the fitted line increases from lower y values at low percent of threshold to higher y values at higher percent of threshold. Text: beta equals .0016; standard error equals 0.0001; p less than .001. Across the four graphs, Condition-based comparisons of lapses and arousals are paired with frequency-domain spectral power curves and a percent-of-threshold relationship for arousal proportion.Four graphs showing sleep motion effects on lapses, arousals, spectral power and arousal proportion.
- Top Cited PapersOpen Access
Evaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography
The development of consumer sleep-tracking technologies has outpaced the scientific evaluation of their accuracy. In this study, five consumer sleep-tracking devices, research-grade actigraphy, and polysomnography were used simultaneously to monitor the overnight sleep of fifty-three young adults in the lab for one night. Biases and limits of agreement were assessed to determine how sleep stage estimates for each device and research-grade actigraphy differed from polysomnography-derived measures. Every device, except the Garmin Vivosmart, was able to estimate total sleep time comparably to research-grade actigraphy. All devices overestimated nights with shorter wake times and underestimated nights with longer wake times. For light sleep, absolute bias was low for the Fitbit Inspire and Fitbit Versa. The Withings Mat and Garmin Vivosmart overestimated shorter light sleep and underestimated longer light sleep. The Oura Ring underestimated light sleep of any duration. For deep sleep, bias was low for the Withings Mat and Garmin Vivosmart while other devices overestimated shorter and underestimated longer times. For REM sleep, bias was low for all devices. Taken together, these results suggest that proportional bias patterns in consumer sleep-tracking technologies are prevalent and could have important implications for their overall accuracy.
Top Cited PapersOpen AccessEvaluating Accuracy in Five Commercial Sleep-Tracking Devices Compared to Research-Grade Actigraphy and Polysomnography
The development of consumer sleep-tracking technologies has outpaced the scientific evaluation of their accuracy. In this study, five consumer sleep-tracking devices, research-grade actigraphy, and polysomnography were used simultaneously to monitor the overnight sleep of fifty-three young adults in the lab for one night. Biases and limits of agreement were assessed to determine how sleep stage estimates for each device and research-grade actigraphy differed from polysomnography-derived measures. Every device, except the Garmin Vivosmart, was able to estimate total sleep time comparably to research-grade actigraphy. All devices overestimated nights with shorter wake times and underestimated nights with longer wake times. For light sleep, absolute bias was low for the Fitbit Inspire and Fitbit Versa. The Withings Mat and Garmin Vivosmart overestimated shorter light sleep and underestimated longer light sleep. The Oura Ring underestimated light sleep of any duration. For deep sleep, bias was low for the Withings Mat and Garmin Vivosmart while other devices overestimated shorter and underestimated longer times. For REM sleep, bias was low for all devices. Taken together, these results suggest that proportional bias patterns in consumer sleep-tracking technologies are prevalent and could have important implications for their overall accuracy.
- Open Access
- 1 May 2023
- Published by Elsevier in Human Factors in Healthcare
- Vol. 3, 100043
Maintaining sleep while improving overnight mobility and comfort with a novel lower limb external mechanical compression system
- 1 May 2023
- Published by Elsevier in Human Factors in Healthcare
- Vol. 3, 100043
Open AccessMaintaining sleep while improving overnight mobility and comfort with a novel lower limb external mechanical compression system
- Open Access
- 23 December 2021
- Published by Elsevier in Acta Psychologica
- Vol. 222, 103478
Age-related changes in sleep-dependent novel word consolidation
- 23 December 2021
- Published by Elsevier in Acta Psychologica
- Vol. 222, 103478
Open AccessAge-related changes in sleep-dependent novel word consolidation
- Open Access
- 19 September 2021
- Published by Wiley in European Journal of Neuroscience
- Vol. 54 (9) , 7332-7354
Ageing‐related changes in nap neuroscillatory activity are mediated and moderated by grey matter volume
Ageing‐related changes in grey matter result in changes in the intensity and topography of sleep neural activity. However, it is unclear whether these findings can be explained by ageing‐related differences in sleep pressure or circadian influence. The current study used high‐density electroencephalography to assess how grey matter volume differences between young and older adults mediate and moderate neuroscillatory activity differences during a midday nap following a motor sequencing task. Delta, theta, and sigma amplitude were reduced in older relative to young adults, especially over frontocentral scalp, leading to increases in relative delta frontality and relative sigma lateral centroposteriority. Delta reductions in older adults were mediated by grey matter loss in frontal medial cortex, primary motor cortex, thalamus, caudate, putamen, and pallidum, and were moderated by putamen grey matter volume. Theta reductions were mediated by grey matter loss in primary motor cortex, thalamus, and caudate, and were moderated by putamen and pallidum grey matter volume. Sigma changes were moderated by putamen and pallidum grey matter volume. Moderation results suggested that across frequencies, young adults with more grey matter had increased activity, whereas older adults with more grey matter had unchanged or decreased activity. These results provide a critical extension of previous findings from overnight sleep in a midday nap, indicating that they are not driven by sleep pressure or circadian confounds. Moreover, these results suggest brain regions associated with motor sequence learning contribute to sleep neural activity following a motor sequencing task.
- 19 September 2021
- Published by Wiley in European Journal of Neuroscience
- Vol. 54 (9) , 7332-7354
Open AccessAgeing‐related changes in nap neuroscillatory activity are mediated and moderated by grey matter volume
Ageing‐related changes in grey matter result in changes in the intensity and topography of sleep neural activity. However, it is unclear whether these findings can be explained by ageing‐related differences in sleep pressure or circadian influence. The current study used high‐density electroencephalography to assess how grey matter volume differences between young and older adults mediate and moderate neuroscillatory activity differences during a midday nap following a motor sequencing task. Delta, theta, and sigma amplitude were reduced in older relative to young adults, especially over frontocentral scalp, leading to increases in relative delta frontality and relative sigma lateral centroposteriority. Delta reductions in older adults were mediated by grey matter loss in frontal medial cortex, primary motor cortex, thalamus, caudate, putamen, and pallidum, and were moderated by putamen grey matter volume. Theta reductions were mediated by grey matter loss in primary motor cortex, thalamus, and caudate, and were moderated by putamen and pallidum grey matter volume. Sigma changes were moderated by putamen and pallidum grey matter volume. Moderation results suggested that across frequencies, young adults with more grey matter had increased activity, whereas older adults with more grey matter had unchanged or decreased activity. These results provide a critical extension of previous findings from overnight sleep in a midday nap, indicating that they are not driven by sleep pressure or circadian confounds. Moreover, these results suggest brain regions associated with motor sequence learning contribute to sleep neural activity following a motor sequencing task.
- 25 August 2021
- Published by Elsevier in Neurobiology of Learning and Memory
- Vol. 185, 107508
Encoding and consolidation of motor sequence learning in young and older adults
- 25 August 2021
- Published by Elsevier in Neurobiology of Learning and Memory
- Vol. 185, 107508
Encoding and consolidation of motor sequence learning in young and older adults