Anca Popa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anca Popa has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Neagu
Department of Functional Sciences, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania
2 shared publications - Monica Miclos-Balica
Victor Babeş University of Medicine and Pharmacy, Second Department of Internal Medicine- Cardiology Clinic, Timisoara, Romania, Romania
2 shared publications - Monica Neagu
Department of Functional Sciences, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania
2 shared publications - Falk Schick
Department of Functional Sciences, ”Victor Babeș” University of Medicine and Pharmacy of Timișoara, 300041 Timisoara, Romania
1 shared publication - Oana Munteanu
Department of Functional Sciences, “Victor Babeș” University of Medicine and Pharmacy of Timișoara, E. Murgu Square, No. 2, 300041 Timișoara, Romania
1 shared publication - Paul Muntean
Department of Functional Sciences, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania
1 shared publication
Latest Publications
- Open Access
Learning Effects in Air Displacement Plethysmography
Air displacement plethysmography (ADP) is a widespread technique for assessing global obesity in both health and disease. The reliability of ADP has been demonstrated by studies focused on duplicate trials. The present study was purported to evaluate learning effects on the reliability of body composition assessment using the BOD POD system, the sole commercially available ADP instrument. To this end, quadruplicate trials were performed on a group of 105 subjects (51 women and 54 men). We estimated measurement error from pairs of consecutive trials—(1,2), (2,3), and (3,4)—to test the hypothesis that early measurements are subject to larger errors. Indeed, statistical analysis revealed that measures of reliability inferred from the first two trials were inferior to those computed for the other pairs of contiguous trials: for percent body fat (%BF), the standard error of measurement (SEM) was 1.04% for pair (1,2), 0.71% for pair (2,3), and 0.66% for pair (3,4); the two-way random effects model intraclass correlation coefficient (ICC) was 0.991 for pair (1,2), and 0.996 for pairs (2,3) and (3,4). Our findings suggest that, at least for novice subjects, the first ADP test should be regarded as a practice trial. When the remaining trials were pooled together, the reliability indices of single ADP tests were the following: ICC = 0.996, SEM = 0.70%, and minimum detectable change (MDC) = 1.93% for %BF, and ICC = 0.999, SEM = 0.49 kg, and MDC = 1.35 kg for fat-free mass (FFM). Thus, the present study pleads for eliminating learning effects to further increase the reliability of ADP.
Open AccessLearning Effects in Air Displacement Plethysmography
Air displacement plethysmography (ADP) is a widespread technique for assessing global obesity in both health and disease. The reliability of ADP has been demonstrated by studies focused on duplicate trials. The present study was purported to evaluate learning effects on the reliability of body composition assessment using the BOD POD system, the sole commercially available ADP instrument. To this end, quadruplicate trials were performed on a group of 105 subjects (51 women and 54 men). We estimated measurement error from pairs of consecutive trials—(1,2), (2,3), and (3,4)—to test the hypothesis that early measurements are subject to larger errors. Indeed, statistical analysis revealed that measures of reliability inferred from the first two trials were inferior to those computed for the other pairs of contiguous trials: for percent body fat (%BF), the standard error of measurement (SEM) was 1.04% for pair (1,2), 0.71% for pair (2,3), and 0.66% for pair (3,4); the two-way random effects model intraclass correlation coefficient (ICC) was 0.991 for pair (1,2), and 0.996 for pairs (2,3) and (3,4). Our findings suggest that, at least for novice subjects, the first ADP test should be regarded as a practice trial. When the remaining trials were pooled together, the reliability indices of single ADP tests were the following: ICC = 0.996, SEM = 0.70%, and minimum detectable change (MDC) = 1.93% for %BF, and ICC = 0.999, SEM = 0.49 kg, and MDC = 1.35 kg for fat-free mass (FFM). Thus, the present study pleads for eliminating learning effects to further increase the reliability of ADP.
- Open Access
- 12 October 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (20) , 10693
Reliability of Repeated Trials Protocols for Body Composition Assessment by Air Displacement Plethysmography
Air displacement plethysmography (ADP) is fast, accurate, and reliable. Nevertheless, in about 3% of the cases, standard ADP tests provide rogue results. To spot these outliers and improve precision, repeated trials protocols have been devised, but few works have addressed their reliability. This study was conducted to evaluate the test–retest reliabilities of two known protocols and a new one, proposed here. Ninety-two healthy adults (46 men and 46 women) completed six consecutive ADP tests. To evaluate the reliability of single measurements, we used the results of the first two tests; for multiple measures protocols, we computed the test result from trials 1–3 and the retest result from trials 4–6. Bland–Altman analysis revealed that the bias and the width of the 95% interval of agreement were smaller for multiple trials than for single ones. For percent body fat (%BF)/fat-free mass, the technical error of measurement was 1% BF/0.68 kg for single trials and 0.62% BF/0.46 kg for the new protocol of multiple trials, which proved to be the most reliable. The minimal detectable change (MDC) was 2.77% BF/1.87 kg for single trials and 1.72% BF/1.26 kg for the new protocol.
- 12 October 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (20) , 10693
Open AccessReliability of Repeated Trials Protocols for Body Composition Assessment by Air Displacement Plethysmography
Air displacement plethysmography (ADP) is fast, accurate, and reliable. Nevertheless, in about 3% of the cases, standard ADP tests provide rogue results. To spot these outliers and improve precision, repeated trials protocols have been devised, but few works have addressed their reliability. This study was conducted to evaluate the test–retest reliabilities of two known protocols and a new one, proposed here. Ninety-two healthy adults (46 men and 46 women) completed six consecutive ADP tests. To evaluate the reliability of single measurements, we used the results of the first two tests; for multiple measures protocols, we computed the test result from trials 1–3 and the retest result from trials 4–6. Bland–Altman analysis revealed that the bias and the width of the 95% interval of agreement were smaller for multiple trials than for single ones. For percent body fat (%BF)/fat-free mass, the technical error of measurement was 1% BF/0.68 kg for single trials and 0.62% BF/0.46 kg for the new protocol of multiple trials, which proved to be the most reliable. The minimal detectable change (MDC) was 2.77% BF/1.87 kg for single trials and 1.72% BF/1.26 kg for the new protocol.