Mohammad Alqudah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Alqudah has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Zoran Obradovic
Temple University
5 shared publications - Mladen Kezunovic
Texas A&M University
4 shared publications - Martin Pavlovski
Temple University
3 shared publications - Ameen Abdel Hai
Temple University
2 shared publications - Tatjana Dokic
Texas A&M University, College Station, TX, USA
2 shared publications Daniel Saranovic
Temple University, Philadelphia, PA 19122 USA
1 shared publication
Latest Publications
- Open Access
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 94840-94851
Enhancing Weather-Related Outage Prediction and Precursor Discovery Through Attention-Based Multi-Level Modeling
Electric grid continually monitors spatiotemporal data from sparse service areas. As power systems grow and get more complex, and with the deployment of more sensors and data collection capabilities, monitoring and analyzing data streams for outage prediction will get more complicated. In addition, the burden on human operators to analyze such data is getting challenging. Furthermore, climate change introduces new challenges to power grid reliability and makes the human grid operators’ task more critical. To address some of these challenges, this research proposes a novel model to jointly predict power grid outages and discover precursors from spatiotemporal data using multi-level data. The new method utilizes multi-task learning (MTL) and multi-instance learning (MIL) to jointly predict outages and learn event precursors. This is achieved by introducing distance-aware self-attention to capture relationships between locations and improve event detection and precursor discovery while utilizing multi-level data (local weather data, global demand, and forecast data) in a sparse setting. Experiments are conducted using five years of data collected in the U.S. Pacific Northwest. The proposed methodology achieves an Area Under the Precision-Recall Curve (AU-PRC) of 0.97 using 12 hours of data before the event. Experiments showed that the proposed model could predict events several hours ahead with high accuracy, where such early predictions allow grid operators to deploy outage mitigation plans. In addition, the new framework effectively discovers spatiotemporal precursors for power outages. Grid operators can use such event precursors to help mitigate outages and improve grid reliability.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 94840-94851
Open AccessEnhancing Weather-Related Outage Prediction and Precursor Discovery Through Attention-Based Multi-Level Modeling
Electric grid continually monitors spatiotemporal data from sparse service areas. As power systems grow and get more complex, and with the deployment of more sensors and data collection capabilities, monitoring and analyzing data streams for outage prediction will get more complicated. In addition, the burden on human operators to analyze such data is getting challenging. Furthermore, climate change introduces new challenges to power grid reliability and makes the human grid operators’ task more critical. To address some of these challenges, this research proposes a novel model to jointly predict power grid outages and discover precursors from spatiotemporal data using multi-level data. The new method utilizes multi-task learning (MTL) and multi-instance learning (MIL) to jointly predict outages and learn event precursors. This is achieved by introducing distance-aware self-attention to capture relationships between locations and improve event detection and precursor discovery while utilizing multi-level data (local weather data, global demand, and forecast data) in a sparse setting. Experiments are conducted using five years of data collected in the U.S. Pacific Northwest. The proposed methodology achieves an Area Under the Precision-Recall Curve (AU-PRC) of 0.97 using 12 hours of data before the event. Experiments showed that the proposed model could predict events several hours ahead with high accuracy, where such early predictions allow grid operators to deploy outage mitigation plans. In addition, the new framework effectively discovers spatiotemporal precursors for power outages. Grid operators can use such event precursors to help mitigate outages and improve grid reliability.
- Open Access
- 29 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 7283-7296
Automated Power System Fault Prediction and Precursor Discovery Using Multi-Modal Data
Electric power system operators monitor large multi-modal data streams from wide service areas. The current data setups stand to get more complex as utilities add more smart-grid sensors to collect additional data from power system substations and other in-situ locations. We propose a methodology to utilize multi-modal data for automated power system fault prediction, and precursor discovery that takes advantage of not only the utility owned measurements but also an abundance of data from other related databases such as weather observation systems. The process is automated to help operators analyze multi-modal data that may be impossible to process manually due to the size and variety. We automatically preprocess multi-source data and learn a joint latent representation from collocated streamed, sparse, and high-dimensional data collected from Phasor Measurement Units and external weather data. Then we utilize multi-instance learning to predict events and discover precursors simultaneously without relying on post-mortem studies of fault signatures. We apply the proposed methodology to provide early predictions of faults in the U.S. Western Interconnection. AU-ROC of 0.94 is achieved in predicting events by utilizing information 5 hours before event time using season-specific models. We show how precursors can be extracted from multi-modal data and interpreted for predicted events.
- 29 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 7283-7296
Open AccessAutomated Power System Fault Prediction and Precursor Discovery Using Multi-Modal Data
Electric power system operators monitor large multi-modal data streams from wide service areas. The current data setups stand to get more complex as utilities add more smart-grid sensors to collect additional data from power system substations and other in-situ locations. We propose a methodology to utilize multi-modal data for automated power system fault prediction, and precursor discovery that takes advantage of not only the utility owned measurements but also an abundance of data from other related databases such as weather observation systems. The process is automated to help operators analyze multi-modal data that may be impossible to process manually due to the size and variety. We automatically preprocess multi-source data and learn a joint latent representation from collocated streamed, sparse, and high-dimensional data collected from Phasor Measurement Units and external weather data. Then we utilize multi-instance learning to predict events and discover precursors simultaneously without relying on post-mortem studies of fault signatures. We apply the proposed methodology to provide early predictions of faults in the U.S. Western Interconnection. AU-ROC of 0.94 is achieved in predicting events by utilizing information 5 hours before event time using season-specific models. We show how precursors can be extracted from multi-modal data and interpreted for predicted events.
- 14 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (5) , 3434-3442
Fault Detection Utilizing Convolution Neural Network on Timeseries Synchrophasor Data From Phasor Measurement Units
An end-to-end supervised learning method is proposed for fault detection in the electric grid using Big Data from multiple Phasor Measurement Units (PMUs). The approach consists of preprocessing steps aimed at reducing data noise and dimensionality, followed by utilization of six classification models considered for detecting faults. Three of the models were variants of Convolutional Neural Network (CNN) architectures that consider a single type of measurement (voltage, current or frequency) at all PMUs or all types together also at all PMUs. CNN based models were compared to traditional methods of Logistic Regression (LR), Multi-layer Perceptron (MLP) and Support Vector Machine (SVM). Evaluation was conducted on two-year data measured by PMUs at 37 locations in a large electric grid. The response variable for classification were extracted from the grid-wide outage event log. Experiments show that CNN-based models outperformed traditional methods on one year out-of-sample outage detection over the entire grid.
- 14 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (5) , 3434-3442
Fault Detection Utilizing Convolution Neural Network on Timeseries Synchrophasor Data From Phasor Measurement Units
An end-to-end supervised learning method is proposed for fault detection in the electric grid using Big Data from multiple Phasor Measurement Units (PMUs). The approach consists of preprocessing steps aimed at reducing data noise and dimensionality, followed by utilization of six classification models considered for detecting faults. Three of the models were variants of Convolutional Neural Network (CNN) architectures that consider a single type of measurement (voltage, current or frequency) at all PMUs or all types together also at all PMUs. CNN based models were compared to traditional methods of Logistic Regression (LR), Multi-layer Perceptron (MLP) and Support Vector Machine (SVM). Evaluation was conducted on two-year data measured by PMUs at 37 locations in a large electric grid. The response variable for classification were extracted from the grid-wide outage event log. Experiments show that CNN-based models outperformed traditional methods on one year out-of-sample outage detection over the entire grid.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-13
Hierarchical Convolutional Neural Networks for Event Classification on PMU Measurements
Event classification is one of the central components of automated disturbance analysis based on phasor measurement unit (PMU) measurements. Obtaining high-quality event labels remains a challenge for supervised learning-based classification of local and system-wide events in power grids due to its labor-intensive requirement. We present a sensitivity study considering rapidly refined, partially, and fully inspected event labels that leads to evidence that hierarchical convolutional neural networks (HCNNs) outperform traditional classification models regardless of the quality of the available event labels. It is demonstrated that performance similar to the one obtained using entirely domain-driven labeling can be achieved as long as the involved expert does not mislabel more than ~5% of the event data captured by PMU measurements.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-13
Hierarchical Convolutional Neural Networks for Event Classification on PMU Measurements
Event classification is one of the central components of automated disturbance analysis based on phasor measurement unit (PMU) measurements. Obtaining high-quality event labels remains a challenge for supervised learning-based classification of local and system-wide events in power grids due to its labor-intensive requirement. We present a sensitivity study considering rapidly refined, partially, and fully inspected event labels that leads to evidence that hierarchical convolutional neural networks (HCNNs) outperform traditional classification models regardless of the quality of the available event labels. It is demonstrated that performance similar to the one obtained using entirely domain-driven labeling can be achieved as long as the involved expert does not mislabel more than ~5% of the event data captured by PMU measurements.
- Open Access
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 127420-127432
Transfer Learning for Event Detection From PMU Measurements With Scarce Labels
Event detection in electrical grids is a challenging problem for machine learning methods due to spatiotemporally nonstationary systems and the inability to automate event labeling in high-volume data such as PMU measurements. As a result, the existing historical event logs created manually do not correlate well with the corresponding PMU measurements due to scarce and temporally imprecise labels. Trying to overcome this problem by extending event logs to a complete set of labeled events is very costly and often infeasible. We focused on utilizing a transfer learning model to reduce the need for additional data labeling by leveraging some labeled data instances available from a small number of well-defined event detection task. To demonstrate the feasibility, we tested our approach on a large dataset collected by 38 PMUs from the Western Interconnection of the U.S.A. over two years. The model evaluation performed based on varying percentages of labeled source data corresponding to ~20-700 characteristic events on different sizes of time windows ranging from 2-seconds to 1-minute demonstrates that the developed method can significantly improve automated event detection based on PMU measurements when extensive labeling is costly or impossible to obtain. When compared to the state-of-the-art machine learning algorithms (unsupervised, semi-supervised, and supervised), the results show that the transfer learning method has significantly better performances when detecting events by learning from as low as 20 representative labeled data instances.
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 127420-127432
Open AccessTransfer Learning for Event Detection From PMU Measurements With Scarce Labels
Event detection in electrical grids is a challenging problem for machine learning methods due to spatiotemporally nonstationary systems and the inability to automate event labeling in high-volume data such as PMU measurements. As a result, the existing historical event logs created manually do not correlate well with the corresponding PMU measurements due to scarce and temporally imprecise labels. Trying to overcome this problem by extending event logs to a complete set of labeled events is very costly and often infeasible. We focused on utilizing a transfer learning model to reduce the need for additional data labeling by leveraging some labeled data instances available from a small number of well-defined event detection task. To demonstrate the feasibility, we tested our approach on a large dataset collected by 38 PMUs from the Western Interconnection of the U.S.A. over two years. The model evaluation performed based on varying percentages of labeled source data corresponding to ~20-700 characteristic events on different sizes of time windows ranging from 2-seconds to 1-minute demonstrates that the developed method can significantly improve automated event detection based on PMU measurements when extensive labeling is costly or impossible to obtain. When compared to the state-of-the-art machine learning algorithms (unsupervised, semi-supervised, and supervised), the results show that the transfer learning method has significantly better performances when detecting events by learning from as low as 20 representative labeled data instances.