APAleksandra A. Pirkova

Aleksandra A. Pirkova

*This is an algorithmically generated author record based on publicly available information.

Aleksandra A. Pirkova has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SAFETY OF DIFFERENT BIOPROSTHESIS TYPES IN TRANSCATHETER IMPLANTATION IN PATIENTS WITH BICUSPID AORTIC VALVE

    by Gaik V. Mardanyan, Marina V. Karuk, Roman S. Polyakov, Mikhail V. Puretskiy, Yurii M. Saakyan, Aleksandra A. Pirkova, Kiazim A. Kur-Ipa, Shota G. Chargaziya, Sergey O. Popov, Sergey A. Abugov, et al.

    Highlights The use of balloon-expandable and self-expanding bioprostheses in bicuspid anatomy is characterized by a comparable safety profile. Hemodynamic advantages of self-expanding systems are negated in the presence of massive calcification of the left ventricular outflow tract. The use of balloon-expandable prostheses in favorable anatomy is associated with a significantly lower risk of conduction disturbances and pacemaker implantation.   Aim . To conduct a comparative analysis of the immediate safety and efficacy outcomes of balloon-expandable and self-expanding bioprostheses in patients with bicuspid aortic valve stenosis, including those with severe calcification of the left ventricular outflow tract (LVOT). Methods. This single-center study included 102 patients with severe bicuspid aortic valve stenosis. Based on the device type and anatomy, patients were divided into three groups: Group 1 (n = 32) received a balloon-expandable valve (BEV, Myval); Group 2 (n = 41) received a self-expanding valve (SEV, Evolut PRO/PRO+); Group 3 (SEV-2, n = 29) included patients with massive LVOT calcification who underwent SEV implantation. Patients with severe LVOT calcification were excluded from the BEV group to prevent annular rupture. Endpoints were evaluated according to VARC-3 criteria. Results. No statistically significant differences were found between the groups regarding primary safety and efficacy endpoints at 30 days. The SEV group demonstrated superior hemodynamic parameters (mean gradient 8.9 ± 3.1 mm Hg) compared to the BEV group (11.6 ± 4.2 mm Hg, p = 0.003). However, in the SEV-2 group, the presence of calcification negated this advantage (mean gradient 12.3 ± 2.8 mm Hg) and was associated with a trend towards a higher incidence of paravalvular regurgitation ≥ grade 2 (13.8%). The permanent pacemaker implantation rate was lower in the BEV group (6.3%) compared to the SEV (12.2%) and SEV-2 (17.2%) groups. The incidence of new left bundle branch block was statistically significantly higher in the SEV-2 group compared to the BEV group (31.0% vs. 9.4%, p = 0.050). Analysis of neurological complications showed that the majority of stroke cases were non-disabling with full regression of symptoms. Conclusion . The use of balloon-expandable and self-expanding bioprostheses in bicuspid aortic valve stenosis is characterized by a comparable safety profile. Device selection requires a differentiated approach: self-expanding systems are the method of choice for massive LVOT calcification, whereas balloon-expandable prostheses are preferred to minimize the risk of conduction disturbances in patients with favorable anatomy.

  • Endovascular treatment of patients with large abdominal aortic aneurysms

    by R.S. Polyakov, G.S. Vlasko, Sh.G. Chargaziya, K.A. Kur-Ipa, M.V. Karuk, M.V. Puretskiy, G.V. Mardanyan, A.A. Pirkova, S.A. Abugov

    Objective. To assess the efficacy and safety of endovascular treatment for infrarenal abdominal aortic aneurysms depending on their size. Material and methods. This retrospective study included 214 patients who underwent endovascular repair of infrarenal aortic aneurysms between 2017 and 2023. Patients were divided into two groups depending on maximum aneurysm diameter: group 1 (n=147) — < 70 mm; group 2 (n=67) — ≥70 mm. We analyzed intraoperative, hospital, and long-term outcomes. Results. Intraoperative and in-hospital outcomes were comparable, except for longer procedure and fluoroscopy times in patients with large aneurysms. In long-term period, patients with aneurysms ≥70 mm had significantly higher incidence of type IB endoleaks (p=0.04), branch stent graft thrombosis (p=0.04), and aneurysm sac growth (p<0.001). Conclusion. Endovascular repair of infrarenal abdominal aortic aneurysms is a highly effective and safe method regardless of aneurysm size. However, patients with aneurysms ≥70 mm exhibit higher rate of long-term complications. Optimization of stent graft fixation techniques and development of long-term follow-up protocols will minimize the risk of adverse outcomes.

  • Technologies for maintaining blood flow through the left subclavian artery during thoracic aortic replacement in the Z-2 zone

    by R.S. Polyakov, Sh.G. Chargaziia, K.A. Kur-Ipa, M.V. Puretskiy, Yu.M. Saakyan, G.V. Mardanyan, A.A. Pirkova, V.M. Safonova, M.V. Karuk, S.A. Abugov, et al.

  • Pre-emptive embolization of inferior mesenteric and lumbar arteries in endovascular abdominal aortic aneurysm repair

    by R.S. Polyakov, K.A. Kur-Ipa, Sh.G. Chargaziya, M.V. Puretskiy, Yu.M. Saakyan, G.V. Mardanyan, A.A. Pirkova, V.M. Safonova, M.V. Karuk, S.A. Abugov

    Objective. To evaluate the impact of pre-emptive embolization of inferior mesenteric and lumbar arteries on the incidence of type II endoleak and aneurysm sac dimensions after EVAR. Material and methods. A retrospective single-center cohort study included 145 patients who underwent EVAR between 2023 and 2025. Patients were divided into two groups: with pre-emptive embolization (n=32) and without this procedure (n=113). Follow-up CT angiography was performed after 12 months. Primary endpoint was the incidence of type II endoleak; secondary endpoints included changes in maximal aneurysm diameter and infrarenal aortic volume. Results. After 12 months, type II endoleak was observed in 3.1% and 17.7% of cases, respectively (p=0.045). Aneurysm sac growth occurred in 6.3% and 15.9% of patients, respectively (p=0.246). Embolization procedures were associated with longer surgery time, increased fluoroscopy duration and greater contrast volume. Conclusion. Pre-emptive embolization of inferior mesenteric and lumbar arteries in EVAR reduces the incidence of type II endoleak and shows a trend towards less aneurysm sac growth despite higher technical complexity and contrast volume.

  • Results of complex endovascular aortic repair with preservation of visceral brunch perfusion

    by R.S. Polyakov, K.A. Kur-Ipa, Sh.G. Chargazia, M.V. Puretsky, Yu.M. Saakyan, G.V. Mardanyan, A.A. Pirkova, V.M. Safonova, M.V. Karuk, S.A. Abugov

    Background. Complex and thoracoabdominal aortic aneurysms are one of the most difficult clinical problems of vascular surgery due to high perioperative mortality in open surgeries and limited possibilities of standard endovascular aortic repair. The development of fenestrated and branched endografts has allowed to significantly expand the indications for endovascular treatment by preserving the visceral brunch perfusion under anatomically adverse conditions. Objective. To evaluate the efficacy and safety of endovascular repair of complex and thoracoabdominal aortic aneurysms using fenestrated and branched endografts. Material and methods. A retrospective single-center cohort study included 95 patients who underwent endovascular repair of the abdominal or thoracoabdominal aortic aneurysms using fenestrated and/or branched endografts between January 2022 and June 2025. Individually manufactured devices (custom-made), universal factory branched components and «on the table» endograft modification were used; the number of fenestrations varied from 1 to 4. Technical success (patency of all target vessels, absence of type I/III endoleaks, no conversion) was the main intraoperative endpoint. Clinical success (absence of contrast-induced nephropathy, mesenteric and spinal ischemia, myocardial infarction and stroke) was evaluated in the hospital period. Survival (aortic-related and overall), secondary interventions and endoleaks were analyzed in the long-term period. Control multispiral computed tomography was performed after 30 days and 12 months. Results. Technical success was achieved in 92 (96.8%) patients. Conversion to open surgery was required in one (1.1%) case. Mean duration of intervention was 165 [120; 205] minutes, volume of contrast media — 240 [160; 300] ml. Clinical success amounted to 95.8%; complications included contrast-induced nephropathy in 3 (3.2%) patients and myocardial infarction in one (1.1%). In-hospital deaths were not recorded. In the long-term period, type IA and type IB endoleaks were revealed in 2 (2.1%) patients, type II endoleaks — in 6 (6.3%); 3 (3.2%) secondary interventions were performed. One long-term fatal outcome (1.1%) not related to aortic pathology was recorded. Conclusion. Endovascular repair of complex and thoracoabdominal aortic aneurysms using fenestrated and branched endografts has demonstrated a high frequency of technical and clinical success with low levels of in-hospital and long-term mortality. Precise preoperative planning, individualization of device selection and use of combined techniques ensure the safety and efficacy of the indicated tactics in patients with adverse anatomy and high comorbidity.

  • Predictors of aneurysmal sac growth after endovascular aortic repair

    by R.S. Polyakov, K.A. Kur-Ipa, Sh.G. Chargaziia, M.V. Puretskiy, Yu.M. Saakyan, G.V. Mardanyan, A.A. Pirkova, V.M. Safonova, M.V. Karuk, S.A. Abugov

    Предикторы роста аневризматического мешка после эндопротезирования инфраренального отдела аорты

  • Short-term results of endovascular thoracoabdominal aortic repair with multi-branched stent-graft: a systematic review and meta-analysis over the last 5 years

    by R.S. Polyakov, G.S. Vlasko, Sh.G. Chargazia, K.A. Kur-Ipa, M.V. Karuk, M.V. Puretsky, G.V. Mardanyan, A.A. Pirkova, S.A. Abugov

    Endovascular repair with multi-branched stent-graft is a common method for thoracoabdominal aortic aneurysms. Objective. To perform a systematic review and meta-analysis of short-term results (30 days) after endovascular treatment of thoracoabdominal aortic aneurysms withmulti-branched stent-graft device in the studies published in the last 5 years. Material and methods. Baseline searching in the PubMed (Medline) database identified 79 studies. Seven articles were included in systematic review. Results. Technical success rate for multi-branched stent-graft was 95.7% (95% CI 93.9—97.5, I2=46%, p=0.085). Incidence of access-related complications was 15.9% (95% CI 13.3—18.5). Type 1 endoleak occurred in 2.6% (95% CI 1.2—3.9), type 3 endoleak — 4% of cases (95% CI 2.4—5.7). Spinal cord ischemia was observed in 13.7% (95% CI 10.7—16.8), paraplegia — in 5.2% (95% CI 3.8—6.5). Post-intervention hemodialysis was necessary in 5.9% of cases (95% CI 4.6—7.3). Repeated interventions were performed in 15.7% of cases (95% CI 8.5—22.9). Mortality rate was 9.9% (95% CI 4.8—14.9) with high heterogeneity (I2=88%, p<0.001). Conclusion. We found high technical success rate, acceptable complication rate and low mortality in early period. It is necessary to study the long-term results.

  • Open Access

    Optimal Angiographic View for Implantation of Self-Expanding Transcatheter Aortic Valves

    by G.V. Mardanyan, Shota G. Chargazia, K.A. Kur-Ipa, R.S. Polyakov, M.V. Puretskiy, A.A. Pirkova, G.S. Vlasko, S.O. Popov, Abugov Sa

    Background. Transcatheter aortic valve implantation is safe and effective alternative to surgical treatment of severe aortic valve stenosis among patients of all risk groups. Optimal implantation depth is key for successful hemodynamic and clinical Results. Despite the improvement of prostheses design and increasing experience of operators cardiac conduction abnormalities and paravalvular leak continue to be a significant complication of this procedure, directly affecting the long-term prognosis. Self-expanding valves require special approaches for optimal angiographic projection to assess the implantation depth of the prosthesis. Aims in this study we compared coplanar view and cusp overlap technique during self-expanding aortic valves implantation. Methods. We performed a retrospective analysis of 81 TAVI performed in Russian Research Center of Surgery. The patients were divided into two groups depending on the implantation projection: coplanar view (CV) and cusp overlap technique (COT). The incidence of cardiac conduction abnormalities (cumulative incidence of third degree AV block and left bundle branch block) depending on the implantation projection was analyzed. The procedural characteristics in the form of contrast agent volume, fluoroscopic time and operator comfort were also evaluated. Results. After TAVI 16 (51.6%) and 13 (26.0%) patients had cardiac conduction disturbances (cumulative incidence of third degree AV block and left bundle branch block) in the CV and COT respectively (p = 0.019). In the CV group, 2 (6.5%) patients, and in the COT group, 3 (6%) patients had third degree AV block (p = 0.935) and 14 (45.2%) и 10 (20%) left bundle branch block (p = 0,016). In the COT group, there was a significant decrease contrast media (181 66.4 mL vs. 158.9 50.8 mL, p = 0.032). Fluoroscopic time also decreased (23.2 7.7 min vs. 21.3 6.8 min), but without a significant difference (p = 0.678). According to the results of the operator survey, the COT projection was more comfortable. Conclusions. Optimal implantation depth is an important condition for achieving hemodynamic efficiency of the prosthesis and reducing the risk of conduction abnormalities. Operator comfort, better assessment of the implantation depth, safety and efficiency of the cusp overlap technique allow its use as the main implantation view for TAVI.

  • Open Access

    Endovascular aneurysm repair using fenestrated endoprostheses made to order from the manufacturer: Case report

    by Sergey A. Abugov, Gordey S. Vlasko, Roman S. Polyakov, Mikhail V. Puretskiy, Gayk V. Mardanyan, Aleksandra A. Pirkova, Dzhul’eTta A. Karamyan, Shota G. Chargaziya, Kiazim A. Kur-Ipa, Пурецкий Михаил Владимирович, et al.

    This article presents two clinical cases of endovascular aneurysm repair using fenestrated endografts manufactured by the manufacturer in patients with juxta and pararenal aortic aneurysm. The variants of endovascular approaches to the treatment of pathology were analyzed. Clinical examples show the specifics of the choice and justification for the use of endovascular treatment. The conclusion is made about the effectiveness of the method.


  • Endovascular aortic repair for unfavorable anatomy of proximal neck of infrarenal aortic aneurysm: a systematic review and meta-analysis

    by G.S. Vlasko, K.A. Kur-Ipa, Sh.G. Chargaziia, R.S. Polyakov, M.V. Puretsky, G.V. Mardanyan, A.A. Pirkova, S.A. Abugov

    ЦЕЛЬ ИССЛЕДОВАНИЯ Провести анализ результатов эндоваскулярного лечения пациентов при неблагоприятной анатомии проксимальной зоны фиксации эндографта, опубликованных в период с 2013 по 2023 г. МАТЕРИАЛ И МЕТОДЫ При первичном отборе было найдено 187 публикаций в базе данных PubMed. Из первоначально идентифицированных результатов поиска проведен анализ 12 работ. РЕЗУЛЬТАТЫ Несмотря на больший риск проксимальных эндоподтеканий в интраоперационном периоде [отношение рисков (ОР) 2,05, 95% доверительный интервал (ДИ) 1,71—2,46; pp=0,85). Также выявлены сопоставимые результаты в группах с благоприятной и неблагоприятной анатомией проксимальной шейки в течение 5-летнего срока наблюдения по частоте всех повторных вмешательств, связанных с первоначальной процедурой (ОШ 1,24, 95% ДИ 0,90—1,71; p=0,20), и частоте летальных исходов от всех причин (ОШ 1,31, 95% ДИ 0,94—1,80; p=0,11). ЗАКЛЮЧЕНИЕ Наблюдается тенденция к улучшению отдаленных результатов эндоваскулярного лечения пациентов при неблагоприятной анатомии проксимальной шейки инфраренальной аневризмы аорты.