Bohdan Sokol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bohdan Sokol has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Valentine Kolobrodov
Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського
5 shared publications - Volodymyr Mykytenko
National Technical Univ. of Ukraine (Ukraine)
2 shared publications Amir Imiev
Server Tıbbi Cihazlar San. Tic. Ltd. Şti., Istanbul
1 shared publication- Bogdan Y. Pinchuk
Казенне підприємство «Конструкторське бюро спеціального приладобудування ''Арсенал''
1 shared publication - Grigoriy Tymchik
Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication - Inna Vasylkovska1 shared publication
Latest Publications
- Open Access
- 10 January 2026
- Published by SE Ukrmetrteststandart in Measurements infrastructure
- No. 11
Improvement of the Secondary measurement standard of the focal length unit in eyeglass lenses measurement
Actions for improvement of the Secondary measurement standard of the focal length unit were provided to ensure measurement accuracy and traceability in ophthalmology. Condition, structure, and metrological characteristics of the Secondary measurement standard of the focal length unit in eyeglass lenses, along with related values, and uncertainties budgets of the standard’s components are given. Ways to improve the existing measurement standard are shown, as well as the results that can be obtained by upgrading the installation. The obtained results will form the basis for the updated secondary standard.
- 10 January 2026
- Published by SE Ukrmetrteststandart in Measurements infrastructure
- No. 11
Open AccessImprovement of the Secondary measurement standard of the focal length unit in eyeglass lenses measurement
Actions for improvement of the Secondary measurement standard of the focal length unit were provided to ensure measurement accuracy and traceability in ophthalmology. Condition, structure, and metrological characteristics of the Secondary measurement standard of the focal length unit in eyeglass lenses, along with related values, and uncertainties budgets of the standard’s components are given. Ways to improve the existing measurement standard are shown, as well as the results that can be obtained by upgrading the installation. The obtained results will form the basis for the updated secondary standard.
- Open Access
- 9 January 2024
- Published by SE Ukrmetrteststandart in Measurements infrastructure
- No. 7
Development of a polarimetric thermal imager calibration method
Measurement of thermal imager characteristics is important for the reliable and efficient operation of the device in various fields, including science, medicine, and industry. Incorrect measurements can lead to errors, which can be critical, especially for military-grade thermal imagers. This article is dedicated to developing a method for monitoring the output parameters of polarimetric thermal imagers based on calibration. During calibration, the following operations are proposed: visual inspection, functionality check, measurement of polarimetric thermal imager parameters, and evaluation of measurement uncertainties. In this article, the controlled parameters of the polarimetric thermal imager are the measured for device temperature and NETD, Noise Equivalent Temperature Difference. For these parameters, a measurement model, a measurement function, and an uncertainty budget have been developed. The uncertainty budget includes only the main and most influential uncertainty components. This methodology can only be used for one type of polarimetric thermal imager, where the determination of the radiation polarization state is achieved by rotating a phase plate.
- 9 January 2024
- Published by SE Ukrmetrteststandart in Measurements infrastructure
- No. 7
Open AccessDevelopment of a polarimetric thermal imager calibration method
Measurement of thermal imager characteristics is important for the reliable and efficient operation of the device in various fields, including science, medicine, and industry. Incorrect measurements can lead to errors, which can be critical, especially for military-grade thermal imagers. This article is dedicated to developing a method for monitoring the output parameters of polarimetric thermal imagers based on calibration. During calibration, the following operations are proposed: visual inspection, functionality check, measurement of polarimetric thermal imager parameters, and evaluation of measurement uncertainties. In this article, the controlled parameters of the polarimetric thermal imager are the measured for device temperature and NETD, Noise Equivalent Temperature Difference. For these parameters, a measurement model, a measurement function, and an uncertainty budget have been developed. The uncertainty budget includes only the main and most influential uncertainty components. This methodology can only be used for one type of polarimetric thermal imager, where the determination of the radiation polarization state is achieved by rotating a phase plate.
- Open Access
- 30 June 2022
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of Kyiv Polytechnic Institute. Series Instrument Making
- No. 63(1),p. 51-57
ERRORS IN THERMAL IMAGERS TEMPERATURE RESOLUTION DETERMINING
Thermal imaging methods of environmental observation are often accompanied by the need to quantify the temperature distribution on the object’s surfaces. In such cases, the accuracy of modeling the information conversion processes that occur in thermal imaging systems is essential. All questions concerning the determination of thermal imagers temperature resolution are important. Experimental methods for determining temperature resolution in this sense are quite unambiguous and well-established in practice. And calculation methods are still being refined and are of interest to the scientific community. The article is devoted to the development of practical methods for calculating the thermal imagers temperature resolution. Such methods must be on the hand one accurate enough, and on the other hand - simple enough to be used in design organizations. The definition of the calculations error is also considered. The calculation model is based on the concept of equivalent noise temperature difference NETD as the most general characteristic of energy transformations in thermal imaging observations. The definition of NETD is based on the use of the thermal imager signal transmission function. A simplified version of the calculation method and an example of determining the temperature resolution for a thermal imager with a microbolometric matrix detector are presented. Such thermal imagers currently occupy a significant part of the market and the calculation of the characteristics of the device with a standard specification may be of interest to specialists. The influence of some elements of the mathematical information transformations model on the temperature resolution is shown. For example, as the background temperature increases, the temperature resolution decreases. The analysis of the proposed calculation model allowed us to outline ways to improve (reduce) temperature resolution. A feature of the developed methods is the possibility of their use for different thermal imaging systems, for example, for polarizing thermal imagers.
- 30 June 2022
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of Kyiv Polytechnic Institute. Series Instrument Making
- No. 63(1),p. 51-57
Open AccessERRORS IN THERMAL IMAGERS TEMPERATURE RESOLUTION DETERMINING
Thermal imaging methods of environmental observation are often accompanied by the need to quantify the temperature distribution on the object’s surfaces. In such cases, the accuracy of modeling the information conversion processes that occur in thermal imaging systems is essential. All questions concerning the determination of thermal imagers temperature resolution are important. Experimental methods for determining temperature resolution in this sense are quite unambiguous and well-established in practice. And calculation methods are still being refined and are of interest to the scientific community. The article is devoted to the development of practical methods for calculating the thermal imagers temperature resolution. Such methods must be on the hand one accurate enough, and on the other hand - simple enough to be used in design organizations. The definition of the calculations error is also considered. The calculation model is based on the concept of equivalent noise temperature difference NETD as the most general characteristic of energy transformations in thermal imaging observations. The definition of NETD is based on the use of the thermal imager signal transmission function. A simplified version of the calculation method and an example of determining the temperature resolution for a thermal imager with a microbolometric matrix detector are presented. Such thermal imagers currently occupy a significant part of the market and the calculation of the characteristics of the device with a standard specification may be of interest to specialists. The influence of some elements of the mathematical information transformations model on the temperature resolution is shown. For example, as the background temperature increases, the temperature resolution decreases. The analysis of the proposed calculation model allowed us to outline ways to improve (reduce) temperature resolution. A feature of the developed methods is the possibility of their use for different thermal imaging systems, for example, for polarizing thermal imagers.
- Open Access
- 30 June 2021
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia
- No. 85,p. 21-26
Computer-Integrated Method of Object Detection by Thermal Polarimetric Imager
Introduction. A simplified mathematical model of infrared radiation transformation and analysis in thermal imagers for different degrees of polarization target environment has been studied. Theoretic results. Monochromatic radiation, which contains natural and linearly polarized components, is considered. The polarized optical signal model is additive. The state of radiation polarization is described by Stokes vectors. The principles of polarization image formation and their analysis using a rotating polarizer and a phase plate are considered. A matrix radiation detector is installed at the output of the optical system. It converts two-dimensional distribution of radiation intensity into an electrical video signal. This combination of polarimetric and video channels forms a polarimetric thermal imager, which has formed a new promising niche of technical means for remote sensing. An algorithm for signal processing in polarimetric thermal imagers is proposed. It is suposed, that linearly polarized component is more pronounced in the target radiation than in the background radiation. At the stage of analysis of the polarization of the total signal coming from the target environment, the direction of the predominant polarization of the whole image is determined. In the case of observing small targets, this direction coincides with the direction of background polarization. Due to the optical means of cutting the specified polarization component of the signal from the total mixture, most of the background image is eliminated, and the fully polarized component of the target radiation remains largely preserved.Conclusions. The contrast of the final image of the target on the background increases significantly, the probability of correct detection of the target increases.
- 30 June 2021
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia
- No. 85,p. 21-26
Open AccessComputer-Integrated Method of Object Detection by Thermal Polarimetric Imager
Introduction. A simplified mathematical model of infrared radiation transformation and analysis in thermal imagers for different degrees of polarization target environment has been studied. Theoretic results. Monochromatic radiation, which contains natural and linearly polarized components, is considered. The polarized optical signal model is additive. The state of radiation polarization is described by Stokes vectors. The principles of polarization image formation and their analysis using a rotating polarizer and a phase plate are considered. A matrix radiation detector is installed at the output of the optical system. It converts two-dimensional distribution of radiation intensity into an electrical video signal. This combination of polarimetric and video channels forms a polarimetric thermal imager, which has formed a new promising niche of technical means for remote sensing. An algorithm for signal processing in polarimetric thermal imagers is proposed. It is suposed, that linearly polarized component is more pronounced in the target radiation than in the background radiation. At the stage of analysis of the polarization of the total signal coming from the target environment, the direction of the predominant polarization of the whole image is determined. In the case of observing small targets, this direction coincides with the direction of background polarization. Due to the optical means of cutting the specified polarization component of the signal from the total mixture, most of the background image is eliminated, and the fully polarized component of the target radiation remains largely preserved.Conclusions. The contrast of the final image of the target on the background increases significantly, the probability of correct detection of the target increases.
- Open Access
- 14 December 2020
- Published by Igor Sikorsky Kyiv Polytechnic Institute in KPI Science News
- No. 4
METHODOLOGY OF DETECTION OF THERMAL REFLECTIONS IN THE INFRARED RANGE
Background. Thermal reflections are a common source of problems in the interpretation of infrared (IR) thermal images. In particular, wet or polished surfaces, such as glass, metals, as well as brick and concrete, can easily reflect infrared radiation but are often overlooked. If left unchecked, these thermal reflections can lead to incorrect detection and recognition of the object or misinterpretation of its actual temperature. Objective. The purpose of a theoretical analysis between the thermal radiation of an object and its reflection is to develop methods for the possibility of attenuation or at least identification of such prints using optical methods. Methods. Light becomes polarized when it interacts with an object or matter through various mechanisms, such as scattering, reflection, or transmission. One of the possibilities of implementing such methods is the use of IR polarizers in combination with thermal imaging surveillance system. Results. Article describes the physical and mathematical model of fingerprint detection and the possibilities of their elimination. The reflected light is partially polarized, so the main approach to its identification is to find the Stokes parameters. The authors considered three main methods for analyzing the state of polarization: the use of a rotating polarizer in front of the observation system, a special matrix with polarizers located on top of each pixel at certain angles, and a method based on dividing the amplitude in the polarimeter. full Stokes vector. Conclusions. The advantages and disadvantages of the considered methods were revealed. The main features of structures and the cost of their implementation, which are necessary for each method, were determined, with the further purpose of their use in the development of a polarizing thermal imaging camera for unmanned aerial vehicles.
- 14 December 2020
- Published by Igor Sikorsky Kyiv Polytechnic Institute in KPI Science News
- No. 4
Open AccessMETHODOLOGY OF DETECTION OF THERMAL REFLECTIONS IN THE INFRARED RANGE
Background. Thermal reflections are a common source of problems in the interpretation of infrared (IR) thermal images. In particular, wet or polished surfaces, such as glass, metals, as well as brick and concrete, can easily reflect infrared radiation but are often overlooked. If left unchecked, these thermal reflections can lead to incorrect detection and recognition of the object or misinterpretation of its actual temperature. Objective. The purpose of a theoretical analysis between the thermal radiation of an object and its reflection is to develop methods for the possibility of attenuation or at least identification of such prints using optical methods. Methods. Light becomes polarized when it interacts with an object or matter through various mechanisms, such as scattering, reflection, or transmission. One of the possibilities of implementing such methods is the use of IR polarizers in combination with thermal imaging surveillance system. Results. Article describes the physical and mathematical model of fingerprint detection and the possibilities of their elimination. The reflected light is partially polarized, so the main approach to its identification is to find the Stokes parameters. The authors considered three main methods for analyzing the state of polarization: the use of a rotating polarizer in front of the observation system, a special matrix with polarizers located on top of each pixel at certain angles, and a method based on dividing the amplitude in the polarimeter. full Stokes vector. Conclusions. The advantages and disadvantages of the considered methods were revealed. The main features of structures and the cost of their implementation, which are necessary for each method, were determined, with the further purpose of their use in the development of a polarizing thermal imaging camera for unmanned aerial vehicles.
- Open Access
- 24 December 2019
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of Kyiv Polytechnic Institute. Series Instrument Making
- No. 58(2),p. 9-15
FEATURES OF USE OF THERMAL IMAGER ON UNMANNED AERIAL VEHICLES
ОСОБЛИВОСТІ ВИКОРИСТАННЯ ТЕПЛОВІЗОРІВ НА БЕЗПІЛОТНИКАХ
- 24 December 2019
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of Kyiv Polytechnic Institute. Series Instrument Making
- No. 58(2),p. 9-15
Open AccessFEATURES OF USE OF THERMAL IMAGER ON UNMANNED AERIAL VEHICLES
ОСОБЛИВОСТІ ВИКОРИСТАННЯ ТЕПЛОВІЗОРІВ НА БЕЗПІЛОТНИКАХ