Simon Templier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Simon Templier has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Baptiste Battelier
LP2N, Laboratoire Photonique Numérique et Nanosciences, Université de Bordeaux, IOGS and CNRS, Talence, France
3 shared publications - Baptiste Gouraud
Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris, France
2 shared publications - Brynle Barrett
University of New Brunswick
2 shared publications Fabien Napolitano
Xblue, 34 Rue de la Croix de Fer, 78105 Saint-Germain-en-Laye, France
2 shared publicationsHenri Porte
Xblue, 34 Rue de la Croix de Fer, 78105 Saint-Germain-en-Laye, France
2 shared publications- Pierrick Cheiney
Xblue, 34 Rue de la Croix de Fer, 78105 Saint-Germain-en-Laye, France
2 shared publications
Latest Publications
- 11 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (45) , eadd3854
Tracking the vector acceleration with a hybrid quantum accelerometer triad
Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold atom–based quantum inertial sensors can potentially provide these high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the full acceleration vector by combining three orthogonal atom interferometer measurements with a classical navigation-grade accelerometer triad. Its ultralow bias permits tracking the acceleration vector over long time scales, yielding a 50-fold improvement in stability (6 × 10 −8 g ) over our classical accelerometers. We record the acceleration vector at a high data rate (1 kHz), with absolute magnitude accuracy below 10 μ g , and pointing accuracy of 4 μrad. This paves the way toward future strapdown applications with quantum sensors and highlights their potential as future inertial navigation units.
- 11 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (45) , eadd3854
Tracking the vector acceleration with a hybrid quantum accelerometer triad
Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold atom–based quantum inertial sensors can potentially provide these high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the full acceleration vector by combining three orthogonal atom interferometer measurements with a classical navigation-grade accelerometer triad. Its ultralow bias permits tracking the acceleration vector over long time scales, yielding a 50-fold improvement in stability (6 × 10 −8 g ) over our classical accelerometers. We record the acceleration vector at a high data rate (1 kHz), with absolute magnitude accuracy below 10 μ g , and pointing accuracy of 4 μrad. This paves the way toward future strapdown applications with quantum sensors and highlights their potential as future inertial navigation units.
- Open Access
Tracking the Vector Acceleration with a Hybrid Quantum Accelerometer Triad
Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold-atom-based quantum inertial sensors can potentially provide such high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the full acceleration vector by combining three orthogonal atom interferometer measurements with a classical navigation-grade accelerometer triad. Its ultra-low bias permits tracking the acceleration vector over long timescales -- yielding a 50-fold improvement in stability ($6 \times 10^{-8}~g$) over our classical accelerometers. We record the acceleration vector at a high data rate (1 kHz), with absolute magnitude accuracy below 10 $\mu g$, and pointing accuracy of 4 $\mu$rad. This paves the way toward future strapdown applications with quantum sensors and highlights their potential as future inertial navigation units.Open AccessTracking the Vector Acceleration with a Hybrid Quantum Accelerometer Triad
Robust and accurate acceleration tracking remains a challenge in many fields. For geophysics and economic geology, precise gravity mapping requires onboard sensors combined with accurate positioning and navigation systems. Cold-atom-based quantum inertial sensors can potentially provide such high-precision instruments. However, current scalar instruments require precise alignment with vector quantities. Here, we present the first hybrid three-axis accelerometer exploiting the quantum advantage to measure the full acceleration vector by combining three orthogonal atom interferometer measurements with a classical navigation-grade accelerometer triad. Its ultra-low bias permits tracking the acceleration vector over long timescales -- yielding a 50-fold improvement in stability ($6 \times 10^{-8}~g$) over our classical accelerometers. We record the acceleration vector at a high data rate (1 kHz), with absolute magnitude accuracy below 10 $\mu g$, and pointing accuracy of 4 $\mu$rad. This paves the way toward future strapdown applications with quantum sensors and highlights their potential as future inertial navigation units. - 12 October 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (4) , 044018
Carrier-Suppressed Multiple-Single-Sideband Laser Source for Atom Cooling and Interferometry
We present an electro-optic modulation technique that enables a single laser diode to realize a cold-atom source and a quantum inertial sensor based on matter-wave interferometry. Using carrier-suppressed dual-single-sideband modulation, an in-phase and quadrature modulator generates two optical sidebands from separate radio-frequency (rf) signals. These sidebands are controlled independently in frequency, phase, and power using standard rf components. Our laser source exhibits improved rejection of parasitic sidebands compared to those based on phase modulators, which generate large systematic shifts in atom interferometers. We measure the influence of residual laser lines on an atom-interferometric gravimeter and show agreement with a theoretical model. We estimate a reduction of the systematic shift by 2 orders of magnitude compared to previous architectures and reach a long-term sensitivity of on the gravitational acceleration with an interrogation time of only . Finally, we characterize the performance of our integrated laser system and show that it is suitable for mobile sensing applications, including gravity surveys and inertial navigation.- 12 October 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (4) , 044018
Carrier-Suppressed Multiple-Single-Sideband Laser Source for Atom Cooling and Interferometry
We present an electro-optic modulation technique that enables a single laser diode to realize a cold-atom source and a quantum inertial sensor based on matter-wave interferometry. Using carrier-suppressed dual-single-sideband modulation, an in-phase and quadrature modulator generates two optical sidebands from separate radio-frequency (rf) signals. These sidebands are controlled independently in frequency, phase, and power using standard rf components. Our laser source exhibits improved rejection of parasitic sidebands compared to those based on phase modulators, which generate large systematic shifts in atom interferometers. We measure the influence of residual laser lines on an atom-interferometric gravimeter and show agreement with a theoretical model. We estimate a reduction of the systematic shift by 2 orders of magnitude compared to previous architectures and reach a long-term sensitivity of on the gravitational acceleration with an interrogation time of only . Finally, we characterize the performance of our integrated laser system and show that it is suitable for mobile sensing applications, including gravity surveys and inertial navigation.