Ahmed Elsherif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed Elsherif has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Sohail Q. Khan
6 shared publicationsFarhan Shahid
4 shared publicationsPouya Ebrahimi
Department of Cardiology Queen Elizabeth Hospital, University Hospitals Birmingham NHS Foundation Trust Birmingham UK
3 shared publicationsSophia Khattak
3 shared publicationsAnwar Hussain
2 shared publicationsSudhakar George
Department of Cardiology Queen Elizabeth Hospital, University Hospitals Birmingham NHS Foundation Trust Birmingham UK
2 shared publications
Latest Publications
- Open Access
- 14 November 2026
- Published by Elsevier in JACC: Case Reports
Single-Access Retrieval of an Entrapped Rotational Atherectomy Burr Using Parallel-Wire STAR Technique
- 14 November 2026
- Published by Elsevier in JACC: Case Reports
Open AccessSingle-Access Retrieval of an Entrapped Rotational Atherectomy Burr Using Parallel-Wire STAR Technique
- Open Access
- 22 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (8)
Subintimal excimer laser coronary atherectomy (S-ELCA) as a bail-out for device-uncrossable chronic total occlusion: case report
Background: Chronic total occlusion (CTO) that cannot be crossed with balloons or microcatheters despite successful guidewire passage represent one of the most challenging scenarios in percutaneous coronary intervention (PCI). Excimer laser coronary angioplasty (ELCA) is an established adjunct for device-uncrossable lesions; however, the safety of its application within the subintimal space remains limited. Case summary: A 67-year-old male with a complex cardiac history, including prior recurrent interventions and coronary artery bypass grafting, was referred for staged PCI of a right coronary artery CTO because of refractory angina (Canadian Cardiovascular Society class III). Following successful antegrade subintimal wire tracking and re-entry using a Stingray balloon, multiple ultra-low-profile balloons and dedicated microcatheters failed to traverse the subintimal-to-true-lumen transition. A 0.9-mm ELCA catheter at 80 mJ/mm2 and 80 Hz was used in the subintimal space without saline flush, successfully creating a traversable channel. Complete revascularization was achieved using six overlapping drug-eluting stents, optimized with intravascular ultrasound guidance. At two-year follow-up, repeat intravascular ultrasound demonstrated vascular healing at the subintimal-re-entry interface. Discussion: This case demonstrates the potential safety and feasibility of subintimal ELCA (SELCA) as a bail-out for device-uncrossable lesions during antegrade dissection re-entry of CTO-PCI, with the first reported evidence of vascular healing at the subintimal laser site at two-year follow-up.
- 22 July 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (8)
Open AccessSubintimal excimer laser coronary atherectomy (S-ELCA) as a bail-out for device-uncrossable chronic total occlusion: case report
Background: Chronic total occlusion (CTO) that cannot be crossed with balloons or microcatheters despite successful guidewire passage represent one of the most challenging scenarios in percutaneous coronary intervention (PCI). Excimer laser coronary angioplasty (ELCA) is an established adjunct for device-uncrossable lesions; however, the safety of its application within the subintimal space remains limited. Case summary: A 67-year-old male with a complex cardiac history, including prior recurrent interventions and coronary artery bypass grafting, was referred for staged PCI of a right coronary artery CTO because of refractory angina (Canadian Cardiovascular Society class III). Following successful antegrade subintimal wire tracking and re-entry using a Stingray balloon, multiple ultra-low-profile balloons and dedicated microcatheters failed to traverse the subintimal-to-true-lumen transition. A 0.9-mm ELCA catheter at 80 mJ/mm2 and 80 Hz was used in the subintimal space without saline flush, successfully creating a traversable channel. Complete revascularization was achieved using six overlapping drug-eluting stents, optimized with intravascular ultrasound guidance. At two-year follow-up, repeat intravascular ultrasound demonstrated vascular healing at the subintimal-re-entry interface. Discussion: This case demonstrates the potential safety and feasibility of subintimal ELCA (SELCA) as a bail-out for device-uncrossable lesions during antegrade dissection re-entry of CTO-PCI, with the first reported evidence of vascular healing at the subintimal laser site at two-year follow-up.
- 6 July 2026
- Published by Springer Nature in Journal of Human Hypertension
- Vol. 40 (9) , 687-688
Previous COVID-19 infection: An overlooked cardiovascular risk factor
- 6 July 2026
- Published by Springer Nature in Journal of Human Hypertension
- Vol. 40 (9) , 687-688
Previous COVID-19 infection: An overlooked cardiovascular risk factor
- Open Access
- 2 July 2026
- Published by Elsevier in JACC: Case Reports
- p. 109126
Real-Time Intravascular Ultrasound-Guided Percutaneous Coronary Intervention for Spontaneous Coronary Artery Dissection
- 2 July 2026
- Published by Elsevier in JACC: Case Reports
- p. 109126
Open AccessReal-Time Intravascular Ultrasound-Guided Percutaneous Coronary Intervention for Spontaneous Coronary Artery Dissection
- Open Access
- 5 April 2026
- Published by Wiley in Clinical Case Reports
- Vol. 14 (4)
Percutaneous Coronary Intervention to Spontaneous Coronary Artery Dissection With Coexistent Takotsubo Cardiomyopathy: A Case Report
Spontaneous coronary artery dissection (SCAD) is an uncommon cause of non‐atherosclerotic acute coronary syndrome (ACS) resulting in myocardial ischemia and ventricular wall motion abnormalities (WMA). SCAD and Takotsubo Cardiomyopathy (TC) share a common risk factor profile and clinical characteristics. We report a 55‐year‐old female patient who presented with chest pain and elevated troponin level. Coronary angiography (CA) showed tortuosity in the first diagonal (D1) artery suspicious of SCAD. Left ventriculogram showed typical apical ballooning of TC. Because of ongoing chest pain during the procedure, we proceeded to percutaneous coronary intervention (PCI) to D1. Intracoronary optical frequency domain imaging (OFDI) of D1 showed intramural hematoma extending to proximal LAD and treated with a 2.25 × 12 mm Promus Element drug‐eluting stent (DES). Transthoracic Echocardiography (TTE) showed mid anterolateral, inferolateral, and all apical hypokinesia of LV with preserved basal segments and mildly impaired systolic function. TTE after 3 months showed fully recovered LV systolic function with resolution of WMA. Repeat CA 6 months later demonstrated healing of SCAD and OFDI showed resolution of the intramural hematoma, and cardiac MRI showed normal LV systolic and full‐thickness delayed enhancement in only the lateral wall.
- 5 April 2026
- Published by Wiley in Clinical Case Reports
- Vol. 14 (4)
Open AccessPercutaneous Coronary Intervention to Spontaneous Coronary Artery Dissection With Coexistent Takotsubo Cardiomyopathy: A Case Report
Spontaneous coronary artery dissection (SCAD) is an uncommon cause of non‐atherosclerotic acute coronary syndrome (ACS) resulting in myocardial ischemia and ventricular wall motion abnormalities (WMA). SCAD and Takotsubo Cardiomyopathy (TC) share a common risk factor profile and clinical characteristics. We report a 55‐year‐old female patient who presented with chest pain and elevated troponin level. Coronary angiography (CA) showed tortuosity in the first diagonal (D1) artery suspicious of SCAD. Left ventriculogram showed typical apical ballooning of TC. Because of ongoing chest pain during the procedure, we proceeded to percutaneous coronary intervention (PCI) to D1. Intracoronary optical frequency domain imaging (OFDI) of D1 showed intramural hematoma extending to proximal LAD and treated with a 2.25 × 12 mm Promus Element drug‐eluting stent (DES). Transthoracic Echocardiography (TTE) showed mid anterolateral, inferolateral, and all apical hypokinesia of LV with preserved basal segments and mildly impaired systolic function. TTE after 3 months showed fully recovered LV systolic function with resolution of WMA. Repeat CA 6 months later demonstrated healing of SCAD and OFDI showed resolution of the intramural hematoma, and cardiac MRI showed normal LV systolic and full‐thickness delayed enhancement in only the lateral wall.
- Open Access
- 20 February 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (13) , 107019
Management of Coronary Artery Perforations
- 20 February 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (13) , 107019
Open AccessManagement of Coronary Artery Perforations
- Open Access
- 26 December 2025
- Published by Wiley
Percutaneous Coronary Intervention to Spontaneous Coronary Artery Dissection with Coexistent Takotsubo Cardiomyopathy: a case report
- 26 December 2025
- Published by Wiley
Open AccessPercutaneous Coronary Intervention to Spontaneous Coronary Artery Dissection with Coexistent Takotsubo Cardiomyopathy: a case report
- Open Access
- 5 April 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (7) , 103393
Intravascular Lithotripsy-Assisted Percutaneous Coronary Intervention of Vein Graft In-Stent Calcified Restenosis
- 5 April 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (7) , 103393
Open AccessIntravascular Lithotripsy-Assisted Percutaneous Coronary Intervention of Vein Graft In-Stent Calcified Restenosis
- Open Access
- 6 October 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3 (13) , 1494-1498
Retrieval of Entrapped Catheter-Mounted Axial Flow Pump From Mitral Subvalvular Apparatus Using a Snare Catheter
- 6 October 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3 (13) , 1494-1498
Open AccessRetrieval of Entrapped Catheter-Mounted Axial Flow Pump From Mitral Subvalvular Apparatus Using a Snare Catheter