Bahareh Kiamanesh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bahareh Kiamanesh has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Ali Behravan
Department of Electrical Engineering and Computer Science, University of Siegen, 57076 Siegen, Germany
3 shared publications - Roman Obermaisser
Department of Electrical Engineering and Computer Science, University of Siegen, 57076 Siegen, Germany
3 shared publications
Latest Publications
- Open Access
Fault Injection with Multiple Fault Patterns for Experimental Evaluation of Demand-Controlled Ventilation and Heating Systems
Heating, ventilation, and air-conditioning (HVAC) systems are large-scale distributed systems that can be subject to multiple faults affecting the electronics, sensors, and actuators, potentially causing high energy consumption, occupant discomfort, degraded indoor air quality and risk to critical infrastructure. Fault injection (FI) is an effective experimental method for the validation and dependability evaluation of such HVAC systems. Today’s FI frameworks for HVAC systems are still based on a single fault hypothesis and do not provide insights into dependability in the case of multiple faults. Therefore, this paper presents modeling patterns of numerous faults in HVAC systems based on data from field failure rates and maintenance records. The extended FI framework supports the injection of multiple faults with exact control of the timing, locality, and values in fault-injection vectors. A multi-dimensional fault model is defined, including the probability of the occurrence of different sensor and actuator faults. Comprehensive experimental results provide insights into the system’s behavior for concrete example scenarios using patterns of multiple faults. The experimental results serve as a quantitative evaluation of key performance indicators (KPI) such as energy efficiency, air quality, and thermal comfort. For example, combining a CO2 sensor fault with a heater actuator fault increased energy consumption by more than 70%.
Open AccessFault Injection with Multiple Fault Patterns for Experimental Evaluation of Demand-Controlled Ventilation and Heating Systems
Heating, ventilation, and air-conditioning (HVAC) systems are large-scale distributed systems that can be subject to multiple faults affecting the electronics, sensors, and actuators, potentially causing high energy consumption, occupant discomfort, degraded indoor air quality and risk to critical infrastructure. Fault injection (FI) is an effective experimental method for the validation and dependability evaluation of such HVAC systems. Today’s FI frameworks for HVAC systems are still based on a single fault hypothesis and do not provide insights into dependability in the case of multiple faults. Therefore, this paper presents modeling patterns of numerous faults in HVAC systems based on data from field failure rates and maintenance records. The extended FI framework supports the injection of multiple faults with exact control of the timing, locality, and values in fault-injection vectors. A multi-dimensional fault model is defined, including the probability of the occurrence of different sensor and actuator faults. Comprehensive experimental results provide insights into the system’s behavior for concrete example scenarios using patterns of multiple faults. The experimental results serve as a quantitative evaluation of key performance indicators (KPI) such as energy efficiency, air quality, and thermal comfort. For example, combining a CO2 sensor fault with a heater actuator fault increased energy consumption by more than 70%.
- Open Access
Realistic Simulation of Sensor/Actuator Faults for a Dependability Evaluation of Demand-Controlled Ventilation and Heating Systems
In the development of fault-tolerant systems, simulation is a common technique used to obtain insights into performance and dependability because it saves time and avoids the risks of testing the behavior of real-world systems in the presence of faults. Fault injection in a simulation offers a high controllability and observability, and thus is ideal for an early dependability analysis and fault-tolerance evaluation. Heating, ventilation, and air conditioning (HVAC) systems in critical infrastructures, such as airports and hospitals, are safety-relevant systems, which not only determine energy consumption, system efficiency, and occupancy comfort but also play an essential role in emergency scenarios (e.g., fires, biological hazards). Hence, fault injection serves as a practical and essential solution to assess dependability in different fault scenarios of HVAC systems. Hence, in this paper, we present a simulation-based fault injection framework with a combination of two techniques, simulator command and simulation code modification, which are applied to fault injector blocks as saboteurs and an automated fault injector algorithm to automatically activate fault cases with certain fault attributes. The proposed fault injection framework supports a comprehensive range of faults and various fault attributes, including fault persistence, fault type, fault location, fault duration, and fault interarrival time. This framework considers noise in a demand-controlled ventilation (DCV) and heating system as a type of HVAC system since it has been demonstrated that any fault injection scenario is accompanied by some impacts on energy consumption, occupancy comfort, and a fire risk. It also supports the reproducibility for a set of specific fault scenarios or random fault injection scenarios. The system model was implemented and simulated in Matlab/Simulink, and fault injector blocks were developed by Stateflow diagrams. An experimental evaluation serves as the assessment of the presented fault injection framework with a defined example of fault scenarios. The results of the evaluation show the correctness, system behavior, accuracy, and other parameters of the system, such as the heater energy consumption and heater duty cycle of the fault injection framework in the presence of different fault cases. In conclusion, the present paper provides a novel simulation-based fault injection framework, which combines simulator command techniques and simulation code modifications for a realistic and automatic fault injection with comprehensive coverage of various fault types and a consideration of noise and uncertainty, allowing for reproducibility of the results. The outputs achieved from the fault injection framework can be applied to fault-tolerant studies in other application domains.
Open AccessRealistic Simulation of Sensor/Actuator Faults for a Dependability Evaluation of Demand-Controlled Ventilation and Heating Systems
In the development of fault-tolerant systems, simulation is a common technique used to obtain insights into performance and dependability because it saves time and avoids the risks of testing the behavior of real-world systems in the presence of faults. Fault injection in a simulation offers a high controllability and observability, and thus is ideal for an early dependability analysis and fault-tolerance evaluation. Heating, ventilation, and air conditioning (HVAC) systems in critical infrastructures, such as airports and hospitals, are safety-relevant systems, which not only determine energy consumption, system efficiency, and occupancy comfort but also play an essential role in emergency scenarios (e.g., fires, biological hazards). Hence, fault injection serves as a practical and essential solution to assess dependability in different fault scenarios of HVAC systems. Hence, in this paper, we present a simulation-based fault injection framework with a combination of two techniques, simulator command and simulation code modification, which are applied to fault injector blocks as saboteurs and an automated fault injector algorithm to automatically activate fault cases with certain fault attributes. The proposed fault injection framework supports a comprehensive range of faults and various fault attributes, including fault persistence, fault type, fault location, fault duration, and fault interarrival time. This framework considers noise in a demand-controlled ventilation (DCV) and heating system as a type of HVAC system since it has been demonstrated that any fault injection scenario is accompanied by some impacts on energy consumption, occupancy comfort, and a fire risk. It also supports the reproducibility for a set of specific fault scenarios or random fault injection scenarios. The system model was implemented and simulated in Matlab/Simulink, and fault injector blocks were developed by Stateflow diagrams. An experimental evaluation serves as the assessment of the presented fault injection framework with a defined example of fault scenarios. The results of the evaluation show the correctness, system behavior, accuracy, and other parameters of the system, such as the heater energy consumption and heater duty cycle of the fault injection framework in the presence of different fault cases. In conclusion, the present paper provides a novel simulation-based fault injection framework, which combines simulator command techniques and simulation code modifications for a realistic and automatic fault injection with comprehensive coverage of various fault types and a consideration of noise and uncertainty, allowing for reproducibility of the results. The outputs achieved from the fault injection framework can be applied to fault-tolerant studies in other application domains.
- Open Access
Fault Diagnosis of DCV and Heating Systems Based on Causal Relation in Fuzzy Bayesian Belief Networks Using Relation Direction Probabilities
The state-of-the-art provides data-driven and knowledge-driven diagnostic methods. Each category has its strengths and shortcomings. The knowledge-driven methods rely mainly on expert knowledge and resemble the diagnostic thinking of domain experts with a high capacity in the reasoning of uncertainties, diagnostics of different fault severities, and understandability. However, these methods involve higher and more time-consuming effort; they require a deep understanding of the causal relationships between faults and symptoms; and there is still a lack of automatic approaches to improving the efficiency. The data-driven methods rely on similarities and patterns, and they are very sensitive to changes of patterns and have more accuracy than the knowledge-driven methods, but they require massive data for training, cannot inform about the reason behind the result, and represent black boxes with low understandability. The research problem is thus the combination of knowledge-driven and data-driven diagnosis in DCV and heating systems, to benefit from both categories. The diagnostic method presented in this paper involves less effort for experts without requiring deep understanding of the causal relationships between faults and symptoms compared to existing knowledge-driven methods, while offering high understandability and high accuracy. The fault diagnosis uses a data-driven classifier in combination with knowledge-driven inference with both fuzzy logic and a Bayesian Belief Network (BBN). In offline mode, for each fault class, a Relation-Direction Probability (RDP) table is computed and stored in a fault library. In online mode, we determine the similarities between the actual RDP and the offline precomputed RDPs. The combination of BBN and fuzzy logic in our introduced method analyzes the dependencies of the signals using Mutual Information (MI) theory. The results show the performance of the combined classifier is comparable to the data-driven method while maintaining the strengths of the knowledge-driven methods.
Open AccessFault Diagnosis of DCV and Heating Systems Based on Causal Relation in Fuzzy Bayesian Belief Networks Using Relation Direction Probabilities
The state-of-the-art provides data-driven and knowledge-driven diagnostic methods. Each category has its strengths and shortcomings. The knowledge-driven methods rely mainly on expert knowledge and resemble the diagnostic thinking of domain experts with a high capacity in the reasoning of uncertainties, diagnostics of different fault severities, and understandability. However, these methods involve higher and more time-consuming effort; they require a deep understanding of the causal relationships between faults and symptoms; and there is still a lack of automatic approaches to improving the efficiency. The data-driven methods rely on similarities and patterns, and they are very sensitive to changes of patterns and have more accuracy than the knowledge-driven methods, but they require massive data for training, cannot inform about the reason behind the result, and represent black boxes with low understandability. The research problem is thus the combination of knowledge-driven and data-driven diagnosis in DCV and heating systems, to benefit from both categories. The diagnostic method presented in this paper involves less effort for experts without requiring deep understanding of the causal relationships between faults and symptoms compared to existing knowledge-driven methods, while offering high understandability and high accuracy. The fault diagnosis uses a data-driven classifier in combination with knowledge-driven inference with both fuzzy logic and a Bayesian Belief Network (BBN). In offline mode, for each fault class, a Relation-Direction Probability (RDP) table is computed and stored in a fault library. In online mode, we determine the similarities between the actual RDP and the offline precomputed RDPs. The combination of BBN and fuzzy logic in our introduced method analyzes the dependencies of the signals using Mutual Information (MI) theory. The results show the performance of the combined classifier is comparable to the data-driven method while maintaining the strengths of the knowledge-driven methods.