LLLinfeng Li

Linfeng Li

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Linfeng Li has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Bo-Wen Liu

    Collaborative Innovation Center for Eco-Friendly and Fire-Safety Polymeric Materials (MoE), State Key Laboratory of Polymer Materials Engineering, National Engineering Laboratory for Eco-Friendly Polymer Materials (Sichuan), College of Chemistry, Sichuan University, Chengdu 610064, P.R. China

    1 shared publication
  • Cun Zhang

    School of Electrical and Information Engineering, Tianjin University, Tianjin, China

    1 shared publication
  • Fei Yuan

    Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON, Canada

    1 shared publication
  • Guoyun Zhou

    University of Electronic Science and Technology of China,School of Materials and Energy,Chengdu,China

    1 shared publication
  • Honghai Wang

    School of Chemical Engineering and Technology, National‐Local Joint Engineering Laboratory for Energy Conservation in Chemical Process Integration and Resources Utilization Hebei University of Technology Tianjin China

    1 shared publication
  • Huixia Sun

    Yuncheng University,Department of Physics and Electronic Engineering,Yuncheng,China

    1 shared publication

Latest Publications

  • Chemically Integrated Ni-P Film Resistors with Controllable Resistance Values on Printed Circuit Board

    by Yuefeng Wang, Guoyun Zhou, Linxian Ji, Ziwei Ma, Qichang Jiang, Mingli Jia, Linfeng Li, Cun Zhang, Huixia Sun

    Integrated process instead of surface mounted technology can reduce high-frequency parasitic effect of common components and improve the reliability of printed circuit board. In this work, a real-time monitoring technology was developed to test the resistance values of integrated resistors. Ni-P film resistors monitored under the real-time monitoring technology were integrated on epoxy resin surface by electroless plating method. The surface morphology of Ni-P film resistor deposited at different temperature were characterized by SEM. The influence of Ni-P film resistor shapes on resistance error was analyzed. The results show that the integrated Ni-P film resistor has the minimum resistance error of 3.2 % when the electroless plating bath temperature is at 80 °C. The resistance error of arbitrary shapes is controlled within 5 %. The Laminate process, thermal shock and thermal recycling experiments confirm that integrated Ni-P film resistors possess excellent thermal and mechanical stability. These interesting features indicate that integrated Ni-P film resistors monitored under the real-time monitoring technology have tremendous potential in manufacture of PCB with high reliability and high precision resistors.


  • A Facile Approach to Fabricating Antibacterial Textile with High Efficiency and Compact Process

    by Linfeng Li, Pengju Yu, Yuanyuan Li, Xi Wu, Wenbin Li, Xiaomin Cheng

    The urgent need of healthcare promotes the research and development of antibacterial textiles. However, conventional antibacterial textile is based on the solution method to form bacteriostatic granules on the textile matrix, and this form of textile has lurking perils to environment and low durability. Herein, a distinctive self‐limiting surface chemical reaction, atomic layer deposition (ALD), is proposed that deposit zinc oxide (ZnO) on cotton fabrics pretreated with polydopamine (PDA) to prepare nanocomposite textiles in an exceedingly short time by meticulously regulating the parameters. The results show that the cotton @ PDA treated for only 10 min has more than 95% antibacterial rate against both S. aureus and E. coli, which is better than that treated by ALD or PDA alone. Besides, the significance of reactive oxygen species in the antibacterial activity of PDA and ZnO composite coating is confirmed by introducing vitamin E for the first time. Thanks to PDA pre coating and the unique interface combination mode of ALD, the antibacterial textiles introduced in this study have excellent durability. The strategy proposed in this paper can provide a theoretical basis for the antibacterial modification of medical devices.


  • Research and Implementation of Super High-Speed Fiber Bragg Grating Demodulator

    by Yarong Hou, Yiming Wang, Honghai Wang, Quan Liu, Linfeng Li, Zhengying Li

    A super high-speed fiber grating demodulator capable of simultaneously demodulating four grating channels is designed. The demodulator uses Fourier domain mode locked laser which consists of a fiber Fabry-Perot tunable filter and a semiconductor optical amplifier. By introducing a non-linear calibration based on optical beat frequency and a reference channel composed of a single-peak filter, the nonlinear effect of the F-P filter and the scanning wavelength drift problem are eliminated, and the demodulation precision and linearity are improved. In addition, combined with hardware circuit and FPGA processing, a high-precision highspeed real-time hardware peak finding method is proposed, which simplifies the demodulation complexity, reduces the design cost, and achieves the ultimate goal of real-time and super high-speed demodulation. The experimental results show that the linearity is 0.9994, the stability is 6pm, the resolution is 2pm, and frequency of the demodulation system is 40kHz within the 20nm demodulation range.


  • Investigation on optimal detection position of DC electromagnetic NDT in crack characterization for high-speed rail track

    by Fei Yuan, Yating Yu, Bowen Liu, Linfeng Li

    Due to the long-term harsh working environment and cyclic loadings, Rolling Contact Fatigue (RCF) crack will occur on the tread of the rail. Therefore, a fast quantitative detection of cracks periodically is essential to guarantee the operation safety of the high-speed rail track. Electromagnetic Nondestructive testing (NDT) technique is one of the effective methods for quantitative crack characterization in conduction metals. For high-speed Electromagnetic NDT, because of the relative motion between the rail and detection device, motion induced eddy current (MIEC) is generated in the surface of the rail, which causes the magnetic field distribution inside the rail more complicated due to the dragging effect, and the literatures focus on the investigation on the optimal detection position is rare. Hence, to obtain the optimal detection sensitivity and strength, it is essential to investigate the optimal detection position in electromagnetic NDT for crack characterization in high speed. This paper perform a deep investigation on the optimal detection position in direct current (DC) electromagnetic NDT by numerical simulation, and the influence of detecting position on the detecting signal at different speeds is investigated. The results show that the DC Electromagnetic NDT can be used for quantitative crack depth characterization, and the optimal detection position with strongest detection signal and high sensitivity for crack depth characterization is located near the inner edge of the excitation coil on the opposite side of the direction of the probe motion. According to the findings in this paper, the high-speed DC electromagnetic NDT method can be applied to other moving metal components crack characterization, such as rotating metal components and pipelines.